Page 339

Index A accessories, order numbers, F-4 ADC/DAC error, 5-20 analog value representation SIMATIC S7 ET 200B-4/8AI, 8-26, 8-39 ET 200B-4AO, 8-87 ET 200B-4AI, 8-70 analog value representation, SIMATIC S5 ET 200B-4/8AI, 8-26 ET 200B-4AO, 8-85 ET 200B-4AI, 8-65

B bus cable, order number, F-4 bus connector, 3-26, 7-13 bus interface, wiring, 3-26

C CE, certification, 6-3 certification CE, 6-3 FM, 6-3 UL/CSA, 6-3 channel error, 5-19, 5-21 channel information, 5-20 channel type, 5-21 coding plugs, 3-9, 8-23, 8-62, 8-83 coding slide switch, 3-9 COM ET 200 V4.x, D-1 common-mode error, analog output module, 5-21 conductor cross sections, 3-23 configuration grounded, 3-17 ungrounded, 3-20 configuration error, analog output module, 5-21 configuration telegram analog ET 200B, B-3 digital ET 200B, B-2 configuring, 4-1

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c connecting loads, ET 200B-4AO, 8-78 connecting transducers ET 200B-4/8AI, 8-7 ET 200B-4AI, 8-53

D device-related diagnostics analog ET 200B, 5-18 digital ET 200B, 5-14 diagnostics operation with IM 308-C, 5-6 operation with S7/M7 DP masters or other PROFIBUS-DP masters, 5-8 device-related diagnostics, analog, 5-18 device-related diagnostics, digital, 5-14 ID-related diagnostics, analog, 5-16 manufacturer ID, 5-13 master station number, 5-13 operation with IM 308-B, D-4 slave diagnostics, 5-5 station status 1 to 3, 5-11 dismantling, 3-14

E electronics block, 1-3 characteristics, 1-6 definition, 1-6 design, 2-4 installing, 3-12 EPROM error, 5-20 error ADC/DAC, 5-20 EPROM, 5-20 error diagnostics by LEDs, 5-3 slave diagnostics, 5-5 ET 200B, 1-3

Index-1

Page 340

Index

ET 200B-16DI block diagram, 7-16 characteristics, 7-15 pin assignment, 7-18 technical data, 7-19 ET 200B-16DI-AC block diagram, 7-75 characteristics, 7-74 pin assignment, 7-76 technical data, 7-78 ET 200B-16DI/16DO block diagram, 7-63, 7-64 characteristics, 7-62 pin assignment, 7-65 technical data, 7-67 ET 200B-16DO block diagram, 7-27, 7-28 characteristics, 7-26 pin assignment, 7-29 technical data, 7-31 ET 200B-16DO-AC block diagram, 7-80 characteristics, 7-79 pin assignment, 7-81 technical data, 7-83 ET 200B-16DO/2A block diagram, 7-33, 7-34 characteristics, 7-32 pin assignment, 7-35 technical data, 7-37 ET 200B-16RO-AC block diagram, 7-85 characteristics, 7-84 pin assignment, 7-86 technical data, 7-88 ET 200B-24DI/8DO, ET 200B-24DI/8DO 0.2ms block diagram, 7-69, 7-70 characteristics, 7-68 pin assignment, 7-71 technical data, 7-73 ET 200B-32DI, ET 200B-32DI 0.2ms block diagram, 7-21, 7-22 characteristics, 7-20 pin assignment, 7-23 technical data, 7-25 ET 200B-32DO block diagram, 7-39, 7-40 characteristics, 7-38 pin assignment, 7-41 technical data, 7-43

Index-2

ET 200B-4/8AI analog value representation SIMATIC S5, 8-26 analog value representation SIMATIC S7, 8-39 characteristics, 8-5 connecting transducers, 8-7 parameters, 8-24 possible IDs, 8-20 schematic circuit diagram, 8-47 technical data, 8-49 terminal assignment, 8-48 ET 200B-4AI analog value representation SIMATIC S7, 8-70 analog value representation, SIMATIC S5, 8-65 block diagram, 8-72 characteristics, 8-51 connecting transducers, 8-53 parameters, 8-63 possible IDs, 8-61 technical data, 8-74 terminal assignment, 8-73 ET 200B-4AO analog value representation SIMATIC S7, 8-87 analog value representation, SIMATIC S5, 8-85 block diagram, 8-89 characteristics, 8-76 connecting loads, 8-78 parameters, 8-84 possible IDs, 8-82 technical data, 8-91 terminal assignment, 8-90 ET 200B-8DI/8DO block diagram, 7-50, 7-51 characteristics, 7-49 pin assignment, 7-52 technical data, 7-54 ET 200B-8DI/8RO-AC block diagram, 7-90 characteristics, 7-89 pin assignment, 7-91 technical data, 7-93 ET 200B-8RO block diagram, 7-45, 7-46 characteristics, 7-44 pin assignment, 7-47 technical data, 7-48

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

Page 341

Index

ET 200B-8DI/8DO HWA block diagram, 7-56, 7-57 characteristics, 7-55 HW cutoff, 7-59 pin assignment, 7-58 technical data, 7-61 external error, 5-19

F feed-current monitoring, analog output module, 5-21 FM, certification, 6-3 fuse, 3-11 approved, 3-11 changing, 3-11 order numbers, 3-11

G grounded configuration, 3-17 GSD file, A-4

I ID ET 200B-4/8AI, 8-20 ET 200B-4AI, 8-61 ET 200B-4AO, 8-82 ID-related diagnostics, analog ET 200B, 5-16 IDs, configuration telegram, B-2, B-3 IM 308-B, D-1 installing electronics block, 3-12 terminal block, 3-2 internal error, 5-19

L LEDs, 2-4, 5-3 LEDs for diagnostics, 5-3

M M-short-circuit, analog output module, 5-21 manufacturer ID, 5-13 master station number, 5-13 module class, 5-20 module defect, 5-19

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c mounting on a standard section rail, 3-6 with shield connecting element, 3-7, 3-8

O order numbers, F-2

P parameterization error, analog output module, 5-21 parameterization missing, 5-19 parameterization telegram, C-2 analog ET 200B, C-2 digital ET 200B, C-2 parameterizing, 4-1 parameters ET 200B-4AO, 8-84 ET 200B-4/8AI, 8-24 ET 200B-4AI, 8-63 incorrect in module, 5-19 parameterization telegram, C-2 process alarm lost, 5-20 PROFIBUS-DP interface, 3-26 PROFIBUS-DP dropline, order number, F-4

S S7-slave, 1-4 shield connecting element, 3-2, 3-5, 3-25 shielding, 3-25 SINEC L2-DP, 1-2 See also PROFIBUS–DP slave diagnostics, D-3 operation with IM 308-B, D-4 slave diagnostics operation with IM 308-C, 5-6 operation with S7/M7 DP masters or other PROFIBUS-DP masters, 5-8 definition, 5-5 device-related diagnostics, analog, 5-18 device-related diagnostics, digital, 5-14 ID-related diagnostics, analog, 5-16 manufacturer ID, 5-13 master station number, 5-13 requesting, 5-10 station status 1 to 3, 5-11 To Next, 5-5 station number, 1-5, 3-9

Index-3

Page 342

Index station status, structure, 5-11

T technical specifications ET 200B-16DI, 7-19 ET 200B-24DI/8DO, ET 200B-24DI/8DO 0.2ms, 7-73 ET 200B-32DI, ET 200B-32DI 0.2ms, 7-25 ET 200B-32DO, 7-43 ET 200B-4/8AI, 8-49 ET 200B-4AI, 8-74 ET 200B-4AO, 8-91 ET 200B-8DI/8DO, 7-54 ET 200B-16DI/16DO, 7-67 ET 200B-16DI-AC, 7-78 ET 200B-16DO, 7-31 ET 200B-16DO/2A, 7-37 ET 200B-16DO-AC, 7-83 ET 200B-16RO-AC, 7-88 ET 200B-8DI/8DO HWA, 7-61 ET 200B-8DI/8RO-AC, 7-93 ET 200B-8RO, 7-48 general, 6-1 terminal block, 1-3 characteristics, 1-5 definition, 1-5 design, 2-2 installing, 3-2 TB1-4/DC, 7-6 TB1/DC, 7-5 TB2-4/DC, 7-9 TB2/DC, 7-8 TB3/DC, 7-7 TB4/DC, 7-10 TB4M/DC, 7-11 TB6/AC, 7-12 TB8-analog, 8-3 wiring, 3-22

Index-4 type file, A-2 applications, 4-4 designation, 4-4, A-2 old type files, E-1 provision, A-2

U UL/CSA, certification, 6-3 ungrounded configuration, 3-20

W wire break, analog output module, 5-21 wiring bus interface, 3-26 terminal block, 3-22

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

Page 343

Siemens AG AUT E 148 Postfach 1963 D–92209 Amberg Federal Republic of Germany

From: Your Name:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Your Title:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Company Name: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Street:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

City, Zip Code:_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Country:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Phone:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Please check any industry that applies to you:

Automotive

Pharmaceutical

Chemical

Plastic

Electrical Machinery

Pulp and Paper

Food

Textiles

Instrument and Control

Transportation

Nonelectrical Machinery

Other _ _ _ _ _ _ _ _ _ _ _ _ _

Petrochemical

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

1

Page 344

Remarks Form Your comments and recommendations will help us to improve the quality and usefulness of our publications. Please take the first available opportunity to fill out this questionnaire and return it to Siemens.

Please give each of the following questions your own personal mark within the range from 1 (very good) to 5 (poor). 1.

Do the contents meet your requirements?

2.

Is the information you need easy to find?

3.

Is the text easy to understand?

4.

Does the level of technical detail meet your requirements?

5.

Please rate the quality of the graphics/tables:

Additional comments: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c