The text of a manual · part 40 of 41
SIMATIC ET 200B Distributed I/O Station Manual: Glossary
Pages 331 to 338 of 344, from SIMATIC ET 200B Distributed I/O Station Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Siemens ET 200B
Page 331
Glossary
B Baud rate
Data transmission rate; specifies the number of bits transferred per second (baud rate = bit rate). ET 200 supports baud rates from 9.6 kbaud to 12 Mbaud.
Bus
Common transmission path connecting all stations; has two defined ends. In ET 200 the bus is a two-wire cable or a waveguide.
Bus connector
Physical connection between bus station and bus cable. ET 200 has bus connectors with and without adapter for programming device/PC and having IP 20 and IP 65 protection ratings.
Bus segment
³ Segment
Bus station
Device which can send or receive data via the bus or amplify this data, e.g. DP master, DP slave, RS 485 repeater, active star coupler.
C Chassis ground
The entire range of interconnected inactive parts of a device that are not subject to any dangerous touch voltages even in the event of a fault.
Coding plug
You set the input/output circuit of analog modules by means of the coding plugs.
Coding slide switch
The setting of the coding slide switch on the ³ terminal block determines which ³ electronics block can be connected.
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c
Glossary-1
Page 332
Glossary
Configuring
Assigning addresses for the inputs/outputs of a slave station.
Control command
A DP master can send commands simultaneously to a group of slaves to synchronize the slave stations. Event-driven synchronization of slave stations is possible using the control commands ³ FREEZE and ³ SYNC.
CP 5410 S5-DOS/ ST
Programming device interface for connection to SINEC L2 and to SINEC L2-DP. The CP 5410 S5-DOS/ST can be plugged into only the PG 730, 740, 750 and 770 programming devices.
D Device-related diagnostics
The highest level of slave-specific diagnostics. Device-related diagnostics refers to the entire slave.
Diagnostics
The detection, pinpointing, classification and further evaluation of errors, faults, malfunctions and signals. Diagnostics provides monitoring functions which run automatically while the system is in operation. This enhances plant availability by reducing setup times and outages. ET 200 supports a number of diagnostics options ranging from an overview of the DO slaves which have reported diagnostics down to monitoring of individual channels.
Diagnostics alarm
Modules having diagnostics capability report systems to the central CPU by means of diagnostics alarms. In SIMATIC S7/M7: When an error is detected or disappears (e.g. wire break), the module triggers a diagnostics alarm if alarms are enabled. The CPU interrupts processing of the application program or lower priority classes and processes the diagnostics alarm block (OB 82). In SIMATIC S5: The diagnostics alarm is mapped within device-related diagnostics. Errors such as wire break, etc. are detected by regularly querying the diagnostics bits of device-related diagnostics.
Glossary-2
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c
Page 333
Glossary
Distributed I/O station
An input/output device used not in the central device but installed at a considerable distance from the CPU. Distributed I/O stations include:
ET 200M, ET 200B, ET 200C, ET 200U DP/AS-I Link S5-95U with PROFIBUS-DP slave interface Other DP slaves from Siemens or other vendors The distributed I/O stations connect to the DP master via the PROFIBUS-DP bus.
DP master
A ³ master which behaves in accordance with standard EN 50170, Part 3 is known as a DP master.
DP slave
A ³ slave which operates on the PROFIBUS with the PROFIBUS-DP protocol and which behaves in accordance with standard EN 50170, Part 3, is a DP slave.
E Electronics block
Upper section of the ET 200B distributed I/O station. The electronics block contains the logic and plugs into the ³ terminal block.
ET 200
The ET 200 distributed I/O system with the PROFIBUS-DP protocol is a bus for connecting distributed I/O to a CPU or an adequate DP master. ET 200 is characterized by fast reaction times since only small amounts of data (bytes) are transferred on the bus. ET 200 is based on the PROFIBUS standard EN 50170, Part 1, and the PROFIBUS-DP standard, EN 50170, Part 3. ET 200 operates on the master/slave principle. DP masters can be, for example, the IM 308-C master interface module or the CPU 315-2 DP. DP slaves can be the ET 200B, ET 200C, ET 200M, ET 200U distributed I/O stations or Siemens DP slaves or other-vendor devices.
F Floating
The reference potentials of control and load circuits are galvanically isolated in the case of floating I/O modules; this is achieved, for example, by means of optocouplers, relay contacts or line transformers. Input and output circuits may be grouped.
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c
Glossary-3
Page 334
Glossary
Floating-ground measurement
Each signal line has its own signal reference line. Floating-ground measurement is required, if the sensors are connected to different potentials and if different signal sources are physically apart. FREEZE
A ³control command issued by the DP master to a group of DP slaves. When it receives the FREEZE control command, the DP slave freezes the current status of the inputs and transmits this information cyclically to the DP master. Every time it receives a FREEZE control command, the DP slave re-freezes the status of its inputs. The input data is not again cyclically transmitted by the DP slave to the DP master until the DP master sends the UNFREEZE control command.
G Ground-referenced measurement
All signal reference lines are run to a common ³ reference potential.
GSD file
Device master data file; file in which the slave-specific characteristics such as number of inputs or outputs, number of diagnostics bits, SYNC-capability, etc. are defined. There is a GSD file for every Siemens DP standard slave. You need this file only if you want to connect a DP standard slave to a DP master that is not a Siemens product. If you are using a Siemens DP master you do not need a GSD file. The device master data for Siemens DP masters is defined in the ³ type file (COM ET 200-specific format).
I IP 20
Degree of protection to DIN 40050: protection against touch with the fingers and ingress of foreign bodies having a diameter larger than 12mm.
M Master
When in possession of the token, the master can send data to other stations and request data from other stations (= active stations). ³ DP masters include, for example the CPU 315-2 DP and the IM 308-C.
Glossary-4
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c
Page 335
Glossary
Master interface module
Module for distributed configuration. The distributed I/O ”connects” to the PLC via the IM 308-C master interface module.
Master/slave method
Bus access method in which only one station is the ³ DP master and all other stations are ³ DP slaves.
N Non-floating
The reference potentials of control and load circuits are electrically connected in the case of non-floating I/O modules.
P Parameterization master
Each DP slave has one parameterization master. On startup, the parameterization master downloads the parameterization data to the DP slave. The parameterization master has read and write access to the DP slave and can change the configuration of a DP slave.
Process alarm
A process alarm is triggered by S7 modules with interrupt capability in response to certain events in the process. The process alarm is reported to the central CPU. The appropriate organization block is then processed, in accordance with the priority of the interrupt. In SIMATIC S7/M7: An operating range is defined, for example by parameterizing an upper and lower limit value. If the process signal (e.g. temperature) of an analog input module exists this range, the module triggers a process alarm if alarms are enabled. The CPU interrupts processing of the application program or lower priority classes and processes the process alarm block (OB 40). In SIMATIC S5: The process alarm is mapped within device-related diagnostics. Errors such as upper limit-value overshoot, etc. are detected by regularly querying the diagnostics bits of device-related diagnostics.
PROFIBUS
PROcess FIeld BUS, German process and field-bus standard, defined by the PROFIBUS standard (EN 50170). It specifies the functional, electrical and mechanical characteristics for a bit-serial field bus system. PROFIBUS is a bus system which networks PROFIBUS-compatible automation systems and field devices on the cell and field levels. PROFIBUS versions support the protocols DP (= Dezentrale Peripherie, distributed I/O), FMS (= Fieldbus Message Specification) or TF (= Technological Functions).
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c
Glossary-5
Page 336
Glossary
PROFIBUS-DP
PROFIBUS system supporting the DP protocol. DP stands for ”dezentrale Peripherie”, or distributed I/O. The ET 200 distributed I/O system is based on the PROFIBUS-DP standard (EN 50170, Part 3). Siemens also uses the designation ”SINEC L2-DP” for PROFIBUS-DP.
Protective ground conductor
A conductor required as a protective measure against electric shock currents. The symbol for the protective ground conductor is PE.
R Reference potential
Potential in relation to which the voltages of the circuits concerned are considered and/or measured.
Response monitoring time
A slave parameter in COM ET 200. If a slave station is not addressed within the response monitoring time, it automatically goes to the safe state, i.e. all outputs are set to ”0”.
S Segment
The bus cable between two terminating resistors forms a segment. A segment contains 0 ... 32 ³ bus stations. Segments can be linked by ³ repeaters.
Short-circuit
A conductive connection, caused by a fault, between conductors that are live in normal operation if no load resistance is inserted in the faulty circuit.
Station number
Each ET 200 bus station must be assigned a station number. The programming device is addressed at station number ”0”. Masters and slaves are assigned station numbers in the range 3 ... 125. Exception: ET 200B is assigned a station number in the range 3 ... 99.
STEP 7
Programming language for generating application programs for SIMATIC S7 controllers.
SYNC
A ³ control command issued by the master to a slave. Using this control command, the master can freeze the outputs at the instantaneous value. The output data for the subsequent frames is stored, but the statuses of the outputs remain unchanged. The outputs are not updated until the master sends the UNSYNC control command.
Glossary-6
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c
Page 337
Glossary
SYNC
A ³ control command issued by the DP master to a group of DP slaves. Using this control command, the DP master instructs the DP slave to freeze the outputs at the instantaneous value. In subsequent frames the slave stores the output data, but the statues of the outputs remain unchanged. Every time it receives a SYNC control command, the DP slave sets the outputs it had stored as output data. The outputs are not again cyclically updated until the DP master sends the UNSYNC control command.
T Terminal block
The terminal block carries the hard wiring. The ³ electronics block plugs into the terminal block.
Terminating resistor
Resistor for matching the impedance of bus cables; terminating resistors are always required at the ends of cables or segments. In ET 200 the terminating resistors are activated/deactivated in ³ bus connectors.
Type file
File required by COM ET 200 for configuring a slave station. The type file contains the definitions of the slave-specific characteristics, for example number of inputs or outputs, number of diagnostics bytes, SYNC capability, etc. Each ET 200B station type has its own type file, which is generated by Siemens, forms a component part of COM ET 200 (version 4.1 and later) or is supplied with the manual.
W Wire break
A break in the lines to a sensor or a fault in the sensor itself.
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c
Glossary-7
Page 338
Glossary
Glossary-8
ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c