Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual ยท part 39 of 41

SIMATIC ET 200B Distributed I/O Station Manual: F Order Numbers

Pages 325 to 330 of 344, from SIMATIC ET 200B Distributed I/O Station Manual

The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Siemens ET 200B

Page 325

F

Order Numbers

Introduction

If you require additional components for your ET 200B system or want to expand your PROFIBUS-DP, you will find the order numbers of the components you need in this chapter.

In this Chapter

The components are listed in two groups:

ET 200B components Accessories for PROFIBUS-DP; the entries are accompanied by references to the various manuals for the PROFIBUS-DP master and configuration software. Section

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

Describes

Page

F.1

Order numbers for ET 200B components

F-2

F.2

Order numbers for PROFIBUS-DP accessories

F-4

F-1

Page 326

Order Numbers

F.1

Order Numbers for ET 200B Components

Electronic Blocks Table F-1

The following types of electronics block are available:

Order Numbers, Electronics Blocks for ET 200B

Electronics Block

Order Number

Description

ET 200B-16DI

6ES7 131-0BH00-0XB0

Inputs: 16

DC 24 V (3 ms)

ET 200B-32DI

6ES7 131-0BL00-0XB0

Inputs: 32

DC 24 V (3 ms)

ET 200B-32DI 0.2ms

6ES7 131-0BL10-0XB0

Inputs: 32

DC 24 V (0.2 ms)

ET 200B-16DO

6ES7 132-0BH01-0XB0

Outputs: 16

DC 24 V (0.5 A/2 A)

ET 200B-16DO/2A

6ES7 132-0BH11-0XB0

Outputs: 16

DC 24 V (2 A)

ET 200B-32DO

6ES7 132-0BL01-0XB0

Outputs: 32

DC 24 V (0.5 A)

ET 200B-8DI/8DO

6ES7 133-0BH01-0XB0

Inputs: 8 Outputs: 8

DC 24 V (3 ms) DC 24 V (0.5 A)

ET 200B-8DI/8DO HWA

6ES7 133-0BH10-0XB0

Inputs: 8 Outputs: 8 down

DC 24 V (3 ms) DC 24 V (0.5 A)/hardware shut-

ET 200B-16DI/16DO

6ES7 133-0BL00-0XB0

Inputs: 16 Outputs: 16

DC 24 V (3 ms) DC 24 V (0.5 A)

ET 200B-24DI/8DO

6ES7 133-0BN01-0XB0

Inputs: 24 Outputs: 8

DC 24 V (3 ms) DC 24 V (0.5 A)

ET 200B-24DI/8DO 0.2ms

6ES7 133-0BN11-0XB0

Inputs: 24 Outputs: 8

DC 24 V (0.2 ms) DC 24 V (0.5 A)

ET 200B-8RO

6ES7 132-0GF00-0XB0

Outputs: 8

REL. DC 24 ... 60 V

ET 200B-16DI-AC

6ES7 131-0HF00-0XB0

Inputs: 16

AC 120/230 V

ET 200B-16DO-AC

6ES7 132-0HF00-0XB0

Outputs: 16

AC 120/230 V (0.5 A)

ET 200B-16RO-AC

6ES7 132-0HH00-0XB0

Outputs: 16

REL. AC 120 V/DC 24 ... 150 V

ET 200B-8DI/8RO-AC

6ES7 133-0HH00-0XB0

Inputs: 8 Outputs: 8

AC 120/230 V REL. AC 120 V/DC 24 ... 150 V

ET 200B-4/8AI

6ES7 134-0KH01-0XB0

8 analog differential inputs or 4 x Pt 100 (measuring principle: integrating)

ET 200B-4AI

6ES7 134-0HF01-0XB0

4 analog differential inputs (Measuring principle: successive approximation)

ET 200B-4AO

6ES7 135-0HF01-0XB0

4 analog outputs

F F-2

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

Page 327

Order Numbers

Terminal Blocks Table F-2

The following types of terminal block are available:

Order Numbers, Terminal Blocks for ET 200B

Terminal Block

Order Number

Description

TB1/DC

6ES7 193-0CA10-0XA0

16 channels, screw terminals, 3 tiers

TB1-4/DC

6ES7 193-0CA20-0XA0

16 channels, screw terminals, 4 tiers

TB2/DC

6ES7 193-OCB10-0XA0

32 channels, screw terminals, 3 tiers

TB2-4/DC

6ES7 193-0CB20-0XA0

32 channels, screw terminals, 4 tiers

TB3/DC

6ES7 193-0CA30-0XA0

16 channels, spring-latching terminals

TB4/DC

6ES7 193-0CB30-0XA0

32 channels, spring-latching terminals

TB4M/DC

6ES7 193-0CE30-0XA0

32 channels, spring-latching terminals with 4th terminal tier for extra ground connections

TB6/AC

6ES7 193-0CC10-0XA0

16 channels, screw terminals, 3 tiers

TB8-analog

6ES7 193-0CD40-0XA0

4-/8 channels, spring-latching terminals

Labeling Strips

You can order additional sets of labeling strips under the following order numbers: Table F-3

Order Numbers, Labeling Strips Set of

Order Number

16DI, 16DO, 8DI/8DO, 8DI/8DO HWA

10

6ES7 193-0BB00-0XA0

32DI, 32DI 0.2ms 32DO, 16DI/16DO, 24DI/8DO, 24DI/8DO 0.2ms

7

6ES7 193-0BD00-0XA0

8RO

10

6ES7 193-0BA00-0XA0

16DO/2A

7

6ES7 193-0BC00-0XA0

16DI-AC, 16DO-AC, 16RO-AC, 8DI/8RO

7

6ES7 193-0BF00-0XA0

4/8AI, 4AI, 4AO

10

6ES7 193-0BE00-0XA0

Labeling Strips for

F ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

F-3

Page 328

Order Numbers

F.2

Order Numbers for PROFIBUS-DP Accessories

Introduction

This section contains a list of the order numbers for the PROFIBUS-DP accessories you need for ET 200B. It also contains lists of the various manuals that you may need, depending on the PROFIBUS-DP master in use.

Network Components for ET 200

Table F-4 shows all the network components for the ET 200 distributed I/O system that you may need in conjunction with ET 200B. Table F-4

Accessories for the ET 200 Distributed I/O System Accessory

RS 485 repeater, PROFIBUS-DP, IP 20

Order Number 6ES7 972-0AA00-0XA0

Bus connectors without programmer adapter (max. 12 MB) with programmer adapter (max. 12 MB) without programmer adapter, without terminating

6ES7 972-0BA10-0XA0 6ES7 972-0BB10-0XA0 6ES7 972-0BA30-0XA0 resistor (max. 1.5 MB) Bus cables

Normal Drum Underground

6XV1 830-0AH10

Repeater adapters

6GK1 510-1AA00

Optical link modules for fiber-optic waveguides

6GK1 502-3AB00

6XV1 830-3BH10 6XV1 830-3AH10

6GK1 502-4AB00 PROFIBUS-DP dropline

6ES7 901-4BD00-0XA0

F F-4

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

Page 329

Order Numbers

Manuals for ET 200 in SIMATIC S5 Table F-5

In order to program and start up an ET 200B with COM ET 200, you will need one of the manuals listed in Table F-5.

Manuals for ET 200 in SIMATIC S5 Manual

Contents

ET 200 Distributed I/O System (6ES5 988-3ES.1)

Description of the IM 308-B master interface for S5-115U, S5-135U and S5-155U

Use of COM ET 200 V4.x ET 200 Distributed I/O System (6ES5 988-3ES.2)

Description of the IM 308-C master interface for S5-115U, S5-135U and S5-155U

Description of the S5-95U with PROFIBUS-DP master interface Use of COM ET 200 Windows Working with the FB IM308C

Manuals for STEP 7 and SIMATIC S7

Table F-6

In order to program and start up an ET 200B with STEP 7, you require the manuals listed in Table F-6. To order manuals with 6ES7 order numbers: see Catalog ST 70

Manuals for STEP 7 and SIMATIC S7 Manual

Contents

S7-300 Programmable Controller Hardware and Installation

Topics including

M7-300 Programmable Controller Hardware and Installation

Topics including

S7-400, M7-400 Programmable Controllers Module Specification

Topics including

System Software for S7-300 and S7-400 Program Design Programming Manual

Topics including description of addressing and diagnostics in SIMATIC S7

System Software for S7-300 and S7-400 System and Standard Functions Reference Manual

Description of the SFCs in STEP 7

Description of the PROFIBUS-DP interface of the CPU 315-2 DP Structuring the PROFIBUS-DP network Bus connectors and RS 485 repeaters Description of the PROFIBUS-DP interfaces in M7-300 Structuring the PROFIBUS-DP network Bus connectors and RS 485 repeaters Description of the PROFIBUS-DP interfaces in S7-400 and M7-400 Structuring a PROFIBUS-DP network Bus connectors and RS 485 repeaters

F ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c

F-5

Page 330

Order Numbers

F F-6

ET 200B Distributed I/O Station EWA 4NEB 812 6089-02c