Page 57
Technical specifications 7.6 SCALANCE XB004-1LDG
Technical specifications Optical parameters Cable type
Single mode glass FO cable
Cable cross-section
10/125 μm
Permitted cable length
0 to 10,000 m
Attenuation
≤ 0.5 dB/km at 1300 nm 13 dB max. permitted FO cable attenuation with 2 dB link power margin
Electrical data Power supply
Voltage range
19.2 to 28.8 VDC Safe Extra Low Voltage (SELV)
Rated voltage
24 VDC
Design
3-terminal plug-in block
Current consumption
Typical
650 mA
Power loss at 24 VDC
Typical
15.6 W
Overvoltage protection at input
PTC resettable fuse (1.0 A / 60 V)
Permitted ambient conditions Ambient temperature
During operation
-10 ℃ to +60 ℃
During storage
-40 ℃ to +80 ℃
During transportation
-40 ℃ to +80 ℃
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. 56 ℃ ambient temperature ≤ 3,000 m above sea level at max. 50 ℃ ambient temperature
Design, dimensions and weight Immunity
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP20
MTBF (EN/IEC 61709; 40 °C)
146 years
Housing material
Polycarbonate (plastic)
Weight
210 g
Dimensions (W x H x D)
45 x 100 x 87 mm
Installation options
•
Mounting on a DIN rail
•
Wall mounting
SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04
57
Page 58
Technical specifications 7.6 SCALANCE XB004-1LDG
Technical specifications Switching properties Aging time
300 seconds
Max. number of learnable MAC addresses
8192
Response to LLDP frames
Blocking
Response to spanning tree BPDU frames
Forwarding
QoS priority queues
4
Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB-000 product line, it is delayed by the store and forward function of the switch • with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) • with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the SCALANCE XB-000 product line that the frame passes through, the longer the frame propagation time.
SCALANCE XB-000
58
Operating Instructions, 07/2014, A2B00077300-04
Page 59
Technical specifications 7.7 SCALANCE XB005G
7.7 Table 7- 7
SCALANCE XB005G Technical specifications of the SCALANCE XB005G
Technical specifications Order number SCALANCE XB005G
6GK5 005-0GA00-1AB2
Attachment to Industrial Ethernet Quantity
5
Design
RJ-45 jacks with MDI-X pinning
Properties
Half / full duplex
Transmission rate
10 / 100 / 1000 Mbps
Permitted cable lengths (Industrial Ethernet)
Alternative combinations per length range
0 to 55 m
•
Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2
•
Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ45 + 10 m TP Cord 4x2 via IE FC RJ45 Outlet
•
Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2
•
Max. 75 m IE FC TP Marine/Trailing Cable 4x2 + 10 m TP Cord 4x2 via IE FC RJ45 Outlet
•
Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2
•
Max. 90 m IE FC TP Standard Cable 4x2 + 10 m TP Cord 4x2 via IE FC RJ45 Outlet
0 ... 85 m
0 ... 100 m
Electrical data Power supply
Voltage range
19.2 to 28.8 VDC Safe Extra Low Voltage (SELV)
Rated voltage
24 VDC
Design
3-terminal plug-in block
Current consumption
Typical
550 mA
Power loss at 24 VDC
Typical
13.2 W
Overvoltage protection at input
PTC resettable fuse (1.0 A / 60 V)
SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04
59
Page 60
Technical specifications 7.7 SCALANCE XB005G
Technical specifications Permitted ambient conditions Ambient temperature
During operation
-10 ℃ to +60 ℃
During storage
-40 ℃ to +80 ℃
During transportation
-40 ℃ to +80 ℃
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. 56 ℃ ambient temperature ≤ 3,000 m above sea level at max. 50 ℃ ambient temperature
Design, dimensions and weight Immunity
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP20
MTBF (EN/IEC 61709; 40 °C)
168 years
Housing material
Polycarbonate (plastic)
Weight
220 g
Dimensions (W x H x D)
45 x 100 x 87 mm
Installation options
•
Mounting on a DIN rail
•
Wall mounting
Switching properties Aging time
300 seconds
Max. number of learnable MAC addresses
8192
Response to LLDP frames
Blocking
Response to spanning tree BPDU frames
Forwarding
QoS priority queues
4
Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB-000 product line, it is delayed by the store and forward function of the switch • with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) • with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the SCALANCE XB-000 product line that the frame passes through, the longer the frame propagation time.
SCALANCE XB-000
60
Operating Instructions, 07/2014, A2B00077300-04
Page 61
Technical specifications 7.8 SCALANCE XB008G
7.8 Table 7- 8
SCALANCE XB008G Technical specifications of the XB008G
Technical specifications Order number SCALANCE XB008G
6GK5 008-0GA00-1AB2
Attachment to Industrial Ethernet Quantity
8
Design
RJ-45 jacks with MDI-X pinning
Properties
Half / full duplex
Transmission rate
10 / 100 / 1000 Mbps
Permitted cable lengths (Industrial Ethernet)
Alternative combinations per length range
0 to 55 m
•
Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2
•
Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ45 + 10 m TP Cord 4x2 via IE FC RJ45 Outlet
•
Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2
•
Max. 75 m IE FC TP Marine/Trailing Cable 4x2 + 10 m TP Cord 4x2 via IE FC RJ45 Outlet
•
Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2
•
Max. 90 m IE FC TP Standard Cable 4x2 + 10 m TP Cord 4x2 via IE FC RJ45 Outlet
0 ... 85 m
0 ... 100 m
Electrical data Power supply
Voltage range
19.2 to 28.8 VDC Safe Extra Low Voltage (SELV)
Rated voltage
24 VDC
Design
3-terminal plug-in block
Current consumption
Typical
650 mA
Power loss at 24 VDC
Typical
15.6 W
Overvoltage protection at input
PTC resettable fuse (1.0 A / 60 V)
SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04
61
Page 62
Technical specifications 7.8 SCALANCE XB008G
Technical specifications Permitted ambient conditions Ambient temperature
During operation
-10 ℃ to +60 ℃
During storage
-40 ℃ to +80 ℃
During transportation
-40 ℃ to +80 ℃
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. 56 ℃ ambient temperature ≤ 3,000 m above sea level at max. 50 ℃ ambient temperature
Design, dimensions and weight Immunity
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP20
MTBF (EN/IEC 61709; 40 °C)
138 years
Housing material
Polycarbonate (plastic)
Weight
260 g
Dimensions (W x H x D)
45 x 100 x 87 mm
Installation options
•
Mounting on a DIN rail
•
Wall mounting
Switching properties Aging time
300 seconds
Max. number of learnable MAC addresses
8192
Response to LLDP frames
Blocking
Response to spanning tree BPDU frames
Forwarding
QoS priority queues
4
Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB-000 product line, it is delayed by the store and forward function of the switch • with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) • with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the SCALANCE XB-000 product line that the frame passes through, the longer the frame propagation time.
SCALANCE XB-000
62