This is a one-page specification and ordering sheet for the Signet Model 8550 ProcessPro flow transmitter. It gives dimensions, electrical and output ratings, environmental limits and the part numbers of the field and panel mount versions and their accessories.
- Device type
- ProcessPro flow transmitter for Signet flow sensors with frequency outputs p. 1
- Power
- 12 to 24 VDC ±10%, regulated; -1: 90 mA max., -2: 220 mA max., -3: 100 mA max. p. 1
- Output versions
- -1: one input, 4 to 20 mA and open collector; -2: one input, 4 to 20 mA and 2 relays; -3: two inputs, two 4 to 20 mA outputs and 2 open collectors p. 1
- Mount versions
- No suffix: field mount; P suffix: panel mount with mounting bracket and panel gasket p. 1
- Part numbers
- 3-8550-1, 3-8550-1P, 3-8550-2, 3-8550-2P, 3-8550-3, 3-8550-3P p. 1
- Sensor input
- 0.5 to 1500 Hz; sensor power 5 VDC ± 1% @ 1.5 mA (2-wire) or @ 20 mA (3 or 4 wire) p. 1
- Current output
- 4 to 20 mA, isolated, passive, adjustable and reversible; max. loop 50 Ω @ 12 V, 325 Ω @ 18 V, 600 Ω @ 24 V p. 1
- Relay output
- Mechanical SPDT, 30 VDC @ 5 A or 250 VAC @ 5 A resistive; High, Low, Pulse, Off p. 1
- Open collector
- Optically isolated, 50 mA max. sink, 30 VDC max. pull-up; maximum 400 pulses/min. p. 1
- Display, keypad
- Alphanumeric 2 x 16 LCD; sealed 4-key silicone rubber keypad p. 1
- Accuracy
- ± 0.5% of reading; current output ±0.03 mA p. 1
- Temperature
- Operating -10 °C to 70 °C (14 °F to 158 °F); storage -15 °C to 80 °C p. 1
- Panel cutout
- 92 mm X 92 mm (3.62 in X 3.62 in.) p. 1
- Accessories
- 3-8050 universal mounting kit; 3-8051 flow integral mount NPT; 3-8050.395 splashproof rear cover (panel mount only) p. 1
What this manual walks you through
- Choosing the output and mount version to order p. 1
- Mounting the field version on a Model 515 or 2536 sensor p. 1
- Sizing the panel cutout p. 1
- Mounting brackets and accessories for the panel version p. 1
Good to know
- The sheet gives the NEMA 4X/IP65 enclosure rating for the front only. p. 1
- Relay and open-collector outputs are limited to 400 pulses per minute. p. 1
- The splashproof rear cover is for the panel mount version and is ordered separately. p. 1
Questions this manual answers
What power supply does the Signet 8550 need?
12 to 24 VDC ±10%, regulated; the -2 relay version draws up to 220 mA. p. 1
What is the difference between the 3-8550-1, -2 and -3?
The -1 has one input with 4 to 20 mA and open collector, the -2 one input with 4 to 20 mA and 2 relays, the -3 two inputs with two 4 to 20 mA outputs and 2 open collectors. p. 1
What does the P at the end of a 3-8550 part number mean?
P is the panel mount version, which includes a mounting bracket and panel gasket; without it the unit is the field mount version. p. 1
What size panel cutout does the 8550 need?
92 mm X 92 mm (3.62 in X 3.62 in.). p. 1
What sensors work with the 8550 transmitter?
Signet flow sensors with frequency outputs, with a sensor input range of 0.5 to 1500 Hz. p. 1
The file
Size and text
Every page · 1
Read it here
The words of each page, so a phone can search and copy them. The pages themselves are in the PDF.
Page1of 1
Open in the PDFThe text of page 1, from the PDF itself
CALL 1-800-577-8111 FOR SALES AND SUPPORT CLICK HERE TO RETURN TO WEBSITE
Specifications
Dimensions 3-8550-XP 96 mm (3.8 in.)
96 mm (3.8 in.)
Optional Splashproof Rear Cover
41mm (1.6 in.)
92 mm (3.6 in.)
56 mm (2.2 in.) 97mm (3.8 in.)
Field version with universal mount
82mm (3.23 in.)
42mm (1.7 in.)
64mm (2.5 in.) 106mm (4.2 in.)
Model 8550 Ordering Notes 1) Use the field mount version to directly mount the instrument to the Model 515 or 2536 integral mount sensor. See sensor data sheet for more information. 2) Field mount and sensor can be ordered in a package. See Integral Mount for more information. 3) Panel Cutout should be 92 mm X 92 mm (3.62 in X 3.62 in.). 4) An optional splash proof rear cover for the panel mount version can be ordered separately if needed. Please refer to Wiring, Installation, and Accessories sections for more information.
General Compatibility: Signet Flow Sensors with frequency outputs Accuracy: ± 0.5% of reading Display: Alphanumeric 2 x 16 LCD Update Rate: 1 second Contrast: User selectable, 5 levels Materials
- Enclosure: PBT
- Panel Case Gasket: Neoprene
- Window: Polyurethane coated polycarbonate
- Keypad: Sealed 4-key silicone rubber Electrical Power: 12 to 24 VDC ±10%, regulated (-1) 90 mA max. (-2) 220 mA max. (-3) 100 mA max. Sensor Input Range: 0.5 to 1500 Hz Sensor Power:
- 2-wire: 5 VDC ± 1% @ 1.5 mA
- 3 or 4 wire: 5 VDC ± 1% @ 20 mA Optically isolated from current loop Short circuit protected Current Output
- 4 to 20 mA, isolated, passive, fully adjustable and reversible
- Max. Loop Impedance: 50 Ω max. @ 12 V 325 Ω max. @ 18 V 600 Ω max. @ 24 V
- Update Rate: 100 ms
- Accuracy: ±0.03 mA
Ordering Information
Electrical (continued) Relay Output:
- Mechanical SPDT contacts: High, Low, Pulse, Off
- Maximum Voltage Rating: 30 VDC @ 5 A , 250 VAC @ 5 A resistive load
- Hysteresis: User selectable
- Maximum 400 pulses/min. Open-Collector Output:
- High, Low, Pulse, Off
- Optically isolated, 50 mA max. sink, 30 VDC max. pull-up voltage.
- Hysteresis: User selectable for exiting alarm condition
- Maximum 400 pulses/min. Environmental Operating Temperature: -10 °C to 70 °C (14 °F to 158 °F) Storage Temperature: -15 °C to 80 °C (5 °F to 176 °F) Relative Humidity: 0 to 95%, non-condensing Enclosure: NEMA 4X/IP65 (front) Shipping Weight
0.325 kg
0.8 lb
Standards and Approvals
- CE, UL, CUL
- RoHS compliant
- Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management
Instrument Part Number 3-8550 ProcessPro® Flow Transmitter Sensor Input, Sensor Power, Outputs - Choose One -1 One input, 2 or 4 wire, 4 to 20 mA and open collector for Hi, Lo, Pulse, or Frequency -2 One input, 4 wire, 4 to 20 mA and 2 relays for Hi, Lo, or Pulse -3 Two inputs, 2 or 4 wire, two 4 to 20 mA outputs and 2 open collectors for Hi, Lo, Pulse, or Frequency Field or Panel Mount - Choose One Field mount P Panel mount; includes mounting bracket and panel gasket 3-8550 - 1
Mfr. Part No. 3-8550-1 3-8550-1P 3-8550-2
Example Part Number - Field mount
Code 159 000 047 159 000 048 159 000 049
Mfr. Part No. 3-8550-2P 3-8550-3 3-8550-3P
Code 159 000 050 159 000 051 159 000 052
Accessories and Replacement Parts Mfr. Part No. Code Description Mounting Accessories 3-8050 159 000 184 Universal mounting kit 3-8051 159 000 187 Flow integral mount NPT 3-0000.596 159 000 641 Heavy duty wall mount bracket (panel mount only) 3-5000.598 198 840 225 Surface mount bracket (panel mount only) 3-8050.395 159 000 186 Splashproof rear cover (panel mount only) Liquid Tight Connectors and Other 3-9000.392 159 000 368 Liquid tight connector kit for rear cover 3-9000.392-1 3-9000.392-2 3-8050.396
159 000 839 159 000 841 159 000 617
(includes 3 connectors) Liquid tight connector kit, NPT (1 connector) Liquid tight connector kit, PG 13.5 (1 connector) RC filter kit (for relay use)
CALL 1-800-577-8111 FOR SALES AND SUPPORT CLICK HERE TO RETURN TO WEBSITE