Page 1 of Signet 8550-3 Flow Transmitter

Manual · Signet

Signet 8550-3 Flow Transmitter

Manual8 pagesPDF 753 KB

Instruction manual for the Signet 8550-3 dual-channel flow transmitter: specifications, mounting, wiring, menus, troubleshooting.

Download the PDF753 KB

Covers · 1 model

The models it covers

Summary

What is in it

Georg Fischer Signet instructions for the 8550-3 Flow Transmitter, a dual input/output unit for Signet flow sensors with frequency output. It lists specifications (display, power, sensor inputs, 4 to 20 mA loops, open-collector outputs, environment), panel and field mounting, wiring of power, loops, sensor inputs and outputs, the VIEW, CALIBRATE and OPTIONS menus (K-factors, setpoints, pulse and frequency modes, averaging), troubleshooting and ordering information for the 3-8550 models and accessories.

Its parts

  1. 1. Specifications
  2. 2. Installation
  3. 3. Electrical Connections
  4. 4. Menu Functions
  5. 5. Troubleshooting
  6. 6. Ordering Information

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

This is the instruction manual for the Signet 8550-3 flow transmitter, the dual input and output version of the ProcessPro 8550. It covers specifications, panel installation, wiring of power, current loops, sensors and open-collector outputs, the menus, troubleshooting and ordering information.

Channels
Two flow sensor inputs, two 4 to 20 mA current loops and two open-collector outputs p. 2, 3
Power
12 to 24 VDC ±10%, regulated, 100 mA max. p. 1
Terminals
1-2 auxiliary power; 3-6 system power and loop power; 7-10 open-collector outputs; 11-16 flow sensor inputs p. 2
Auxiliary power
Needed for sensors over 1.5 mA: Signet 2000, 2507, 2551, 2552 and all open collector signal inputs p. 3
Current output
4 to 20 mA, isolated, adjustable and reversible; max. loop 50 Ω @ 12 V, 325 Ω @ 18 V, 600 Ω @ 24 V p. 1, 2
Open-collector outputs
50 mA max. sink, 30 VDC max. pull-up; High, Low, volumetric Pulse (max. 300 pulses/min) or Frequency p. 1, 6
Sensor input range
0.5 to 1500 Hz p. 1
Sensor cable length
60 m (200 ft.) for 515/8510-XX, 525 and sinusoidal signals; 305 m (1000 ft) for 2536/8512-XX, 2540/2541 and open-collector signals p. 3
Display
2 x 16 LCD; contrast 1 (lowest) to 5 (highest) p. 1, 7
Keypad
Sealed 4-key silicone rubber p. 1
Totalizers
A resettable and a permanent totalizer for each channel p. 4
Mounting
Panel mount for a 1/4 DIN punch; field mount with the 3-8051 Integral or 3-8050 Universal Mounting Kit p. 1, 2
Weight
Approx. 325 g (12 oz.) p. 1
Rating, altitude
NEMA 4X/IP65 front; maximum altitude 2000 m (6562 ft) p. 1

What this manual walks you through

  • Installing the transmitter in a panel p. 2
  • Wiring and removing wires from the lever terminals p. 2
  • Connecting power and current loops to a PLC or recorder p. 3
  • Wiring flow sensor inputs p. 3
  • Setting the open-collector outputs to Low, High, Frequency or Pulse p. 4
  • Reading flow, delta flow, totals and loop current in the VIEW menu p. 4
  • Editing settings in the CALIBRATE and OPTIONS menus p. 5
  • Setting units, K-Factors, loop range and output setpoints p. 6
  • Averaging, sensitivity, loop adjustment and output tests p. 7
  • Troubleshooting display messages p. 8

Good to know

  • Remove power before wiring input and output connections. p. 1
  • Open the terminal jaws fully before removing a wire, or the instrument may be permanently damaged. p. 2
  • Do not route sensor cable in conduit with AC power wiring. p. 3
  • K-Factors cannot be set to 0. p. 6
  • Sensitivity has no effect when averaging is set to zero. p. 7

Questions this manual answers

Which flow sensors need auxiliary power on the 8550-3?

Sensors that need more than 1.5 mA: the Signet 2000, 2507, 2551, 2552 and all open collector signal inputs, on terminals 1 and 2. p. 2, 3

Where do I find the K-Factor for the 8550?

The K-Factor depends on the sensor model and the pipe size and schedule; the manual points to the sensor manual. Limits are 0.0001 to 99999. p. 6

How long can the sensor cable be on the 8550-3?

60 m (200 ft.) for 515/8510-XX, 525 and sinusoidal signals, and 305 m (1000 ft) for 2536/8512-XX, 2540/2541 and open-collector signals. p. 3

How do I reset the totalizer on the 8550?

In the VIEW menu, show the resettable totalizers and press the ► key; if reset is locked, the key code must be entered first. p. 4

Why is the 8550 open collector output always on?

The manual gives a hysteresis value that is too large or a defective transmitter; change the hysteresis or replace the transmitter. p. 8

The whole text · 1 part

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8

The file

Revision and size

Revision3-8550.090-3 Rev. M 09/12
PublisherGeorg Fischer Signet LLC
Pages8
PDF753 KB
TextText from the PDF itself.

The first pages · 3 of 8

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 8
Page 2
Page 2of 8
Page 3
Page 3of 8

More documents · 2

For the same models