The text of a manual · part 1 of 3
Slim Line (SL/SLX) Series Industrial Ethernet Switches & Media Converter Installation Guide, pages 1 to 10
Pages 1 to 10 of 30
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sixnet 8-port SL-8-ES-1
Page 1
Slim Line (SL/SLX) Series Industrial Ethernet Switches & Media Converter Installation Guide Revision: 31 August 2009 http://www.sixnet.com
Page 2
Table of Contents Section 1
General Information
Page 4
Section 2
LED Indicators
Page 6
Section 3
Installation / Mounting
Page 8
Section 4
Power Wiring
Page 18
Section 5
Communication Wiring
Page 22
Section 6
Technical Specifications
Page 26
Section 7
Service Information
Page 30
This manual applies to the following products: • SL-2ES-# 2-port unmanaged Ethernet media converter • SL/SLX- 5ES-# 5-port unmanaged Ethernet switch with 5 10/100 ports • SL/SLX- 5MS-# 5-port managed Ethernet switch with 5 10/100 ports • SL/SLX-5MS-MDM-1 5-port managed Ethernet land-line modem with 5 10/100 ports • SL/SLX- 6ES-# 6-port unmanaged Ethernet switch • SL/SLX- 8ES/9ES-# 8/9-port unmanaged Ethernet switch with 8 or 9 10/100 ports • SL/SLX- 8MS-# 8-port managed Ethernet switch with 8 10/100 ports • SL/SLX- 8MG-1 8-port managed Ethernet switch with 8 Gigabit ports • SLX-10MG-1 10-port managed Gigabit Ethernet switch with 10 ports • SLX-16MS-1 16-port managed Ethernet switch with 16 10/100 ports • SLX-18MG-1 18-port managed Gigabit Ethernet switch with 18 ports
To obtain support for Sixnet products: Latest product info: http://www.sixnet.com E-mail: mailto: support@sixnet.com Phone: +1 (518) 877-5173 Fax: +1 (518) 877-8346 Mailing address: Sixnet Technology Park, 331 Ushers Road, Ballston Lake, NY 12019
Sixnet Slim Line Switch Installation Guide
Page 2 of 30
Page 3
SIXNET Protected Technology Policy - Sixnet protects your investment in Sixnet systems with longterm planned technology and our unique Protected Technology Policy. We will continue to support the specified capabilities of standard Sixnet products for at least five years (twenty years for Industrial Managed Switches). We plan each product improvement and new feature to be upward compatible with existing designs and installations. Our goals are to make each new software release bring new power to your Sixnet systems and have every existing feature, applications program and data file continue to work. We protect your investment even further with a liberal five-year trade-in policy. Exchange standard products for upgraded versions of the same product to take advantage of new features and improvements at any time for five years. A prorated trade-in allowance will be given for your existing unit. Sixnet protects your longterm productivity with state-of-the-art planned technology and continued support.
Sixnet Statement of Limited Warranty - Sixnet, manufacturer of Sixnet products, warrants to Buyer that products, except software, manufactured by Sixnet will be free from defects in material and workmanship. Sixnet's obligation under this warranty will be limited to repairing or replacing, at Sixnet's option, the defective parts within one year of the date of installation, or within 18 months of the date of shipment from the point of manufacture, whichever is sooner. Products may be returned by Buyer only after permission has been obtained from Sixnet. Buyer will prepay all freight charges to return any products to the repair facility designated by Sixnet. This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation, maintenance, misuse, neglect or any cause other than ordinary commercial or industrial applications. In particular, Sixnet makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose. All such warranties are hereby expressly disclaimed. No oral or written information or advice given by Sixnet or Sixnet’s representative shall create a warranty or in any way increase the scope of this warranty. This limited warranty is in lieu of all other warranties whether oral or written, expressed or implied. Sixnet's liability shall not exceed the price of the individual units, which are the basis of the claim. In no event shall Sixnet be liable for any loss of profits, loss of use of facilities or equipment, or other indirect, incidental or consequential damages.
INSTALLATION WARNINGS - These products should not be used to replace proper safety interlocking. No software-based device (or any other solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, Sixnet disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in any application. All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction. FCC Statement - This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician for help.
Copyright & Trademarks - Copyright ©2008 Sixnet, LLC. All Rights Reserved.
Note: All information in this document is subject to change without notice.
Sixnet Slim Line Switch Installation Guide
Page 3 of 30
Page 4
Section 1 Overview
General Information This manual will help you install and maintain these industrial Ethernet switches. Installation of these switches is very easy and they will begin to operate as soon as they are powered up. For the unmanaged models (denoted by ES in their part number) there are no user settings so they are truly plug and play. The managed models (denoted by MS in their part number) will act as unmanaged switches until they are configured otherwise. Refer to the managed switch software manual for configuration of advanced network functionality. Note: This manual only covers the installation and wiring of these switches. For the managed models refer to the separate Software User Manuals for details on configuring and using any of the management functions such as SNMP, RSTP, IGMP, VLANs, security, port mirroring and much more.
Operation
Unlike an Ethernet hub that broadcasts all messages out all ports, these industrial Ethernet switches will intelligently route Ethernet messages only out the appropriate port. The major benefits of this are increased bandwidth and speed, reduction or elimination of message collisions, and deterministic performance when tied with real-time systems. These industrial Ethernet switches can support 10BaseT (10 Mbps), 100BaseT (100 Mbps) and 1000BaseT (100 Mbps) on their RJ45 ports (depending on the model). Each of these ports will independently auto-sense the speed/duplex, mdi/mdix-crossover and polarity allowing you to use straight, crossed or even mis-wired cables. Some models also have one or more fiber optic ports for making noise immune connections up to 120 km.
Performance Specifications
These general specifications apply to these industrial Ethernet switches. Refer to Section 7 for complete technical specifications. Number of ports Ethernet Switch Type Ethernet Switch Mode Ethernet Protocols RJ45 Ports Speed RJ45 Ports Operation Fiber Optic Port Speed Fiber Optic Type
Safety Standards
2, 5, 6, 8, 9, 10, 16 or 18 Ethernet ports Unmanaged (ES models) or managed (MS models) Store and forward, wire-speed, non-blocking All standard IEEE 802.3 protocols supported 10/100 or 10/100/1000 Mbps Auto-negotiation, auto-mdi/mdix-crossover and auto-polarity 100 Mbps (SC or ST) or 1000 Mbps (SFP/LC) Multimode, singlemode, long-haul or special application
These industrial Ethernet Switches meet the following standards plus others: Note: Some ratings may be pending on newer models. Contact Sixnet for latest info. Sixnet, LLC is an ISO9001:2000 certified company (FM 65232) since 1996. These devices are design, developed and manufactured per an ISO9001 quality management system.
Electrical safety – • CE per Low Voltage Directive and EN61010-1 (IEC1010) • UL recognition per UL508 (UL File # E179490) • CSA per C22.2/14 (cUL File # E179490) See warnings below.
Install the Managed Switches in accordance with local and national electrical codes.
Sixnet Slim Line Switch Installation Guide
Page 4 of 30
Page 5
Lightning Danger: Do not work on equipment during periods of lightning activity. Do not connect a telephone line into one of the Ethernet RJ45 connectors.
EMC (emissions and immunity) – • CE per the EMC directive, EN 55022 or IEC 61326-1 or EN 61000-6-2/4 • FCC part 15 and ICES 003; Class B. See FCC statement on previous page.
Marine, maritime and offshore – These devices, when installed in an appropriately IP rated enclosure, comply with the ABS standards which is similar to DNV No. 2.4 and equivalent Lloyds. See warning below.
For marine and maritime compliance, do not install this product within 5 meters of a standard or a steering magnetic compass.
WEEE compliance – These devices comply with the WEEE directive. Do not throw away these devices in the standard trash. Contact Sixnet regarding proper disposal.
9RoHS
RoHS compliance – These devices comply with the RoHS directive and are consider lead and other hazardous substance free.
Hazardous Locations – • CE per ATEX directive and EN50021/EN60079-15 (Zone 2); EEx nA II T4 X (-40°c ≤ Ta ≤ +85°C) • UL per UL1604 (Class I, Div. 2), Groups A,B,C,D (UL File # E192531) • CSA per C22.2/213 (Class 1, Div. 2), Groups A,B,C,D (cUL File # E192531) See warnings below.
WARNING (EXPLOSION HAZARD)
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2 (ZONE 2).
WARNING (EXPLOSION HAZARD)
WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS.
WARNING (EXPLOSION HAZARD)
DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
WARNING (EXPLOSION HAZARD)
IN HAZARDOUS OR POTENTIALLY HAZARDOUS LOCATIONS, DO NOT SEPARATE ANY PART OF THE UNIT WHEN ENERGIZED. USE THE UNIT FOR INTERNAL CONNECTIONS ONLY.
Sixnet Slim Line Switch Installation Guide
Page 5 of 30
Page 6
Section 2 Overview
LED Indicators All these industrial Ethernet switches have 1 or 2 communication LEDs for each port and a power LED. The managed models also have an “OK” output LED, a status LED and dual power LEDs. Refer to the sample pictures below for the location of these LEDs.
Typical LED Location (varies with model)
Status LED
Managed Models Only: The Status LED indicates the overall health of the switch. It is normally ON solid indicating that no internal CPU or software problems are detected. It will flash when loading firmware and briefly on power up or reset. Otherwise, if it is OFF or flashing for an extended period of time then a problem is detected. In this case, please contact Sixnet for support.
Power LED
On unmanaged models there is typically one power LED that is ON if either power input (P1 or P2) has power applied to it. On the managed models (and some unmanaged models) there are two Power LEDs that indicate if there is power applied to the respective input.
ACT / LNK LED
This is the Yellow LED on models with two LEDs per RJ45 port. Indicates that there is a proper Ethernet connection (Link) between ON (yellow) the port and another Ethernet device, but no communications activity (not flashing) is detected. Indicates that there is a proper Ethernet connection (Link) between ON (yellow) the port and another Ethernet device, and that there is (flashing) communications activity.
OFF
Speed 10/100 LED
Indicates that there is not a proper Ethernet connection (Link) between the port and another Ethernet device. Make sure the cable has been plugged securely into the ports at both ends.
This is the Green LED on models with two LEDs per RJ45 port.
ON (green)
A 100 Mbps (100BaseT) connection is detected.
OFF
A 10 Mbps (10BaseT) connection is detected.
Sixnet Slim Line Switch Installation Guide
Page 6 of 30
Page 7
ACT / LNK / Speed LED
This is a bi-color (green and yellow or orange) LED on models with one LED per RJ45 port. Indicates that there is a proper Ethernet connection (Link) between ON Solid the port and another Ethernet device, but no communications activity (not flashing) is detected. Indicates that there is a proper Ethernet connection (Link) between the port and another Ethernet device, and that there is Flashing communications activity. On 10/100 ports, a 100 Mbps connection is detected. Green On 10/100/1000 ports, a 1000 Mbps connection is detected. Yellow or On 10/100 ports, a 10 Mbps connection is detected. ON 10/100/100 ports, a 10 or 1000 Mbps connection is detected. Orange
OFF
Indicates that there is not a proper Ethernet connection (Link) between the port and another Ethernet device. Make sure the cable has been plugged securely into the ports at both ends.
OK LED
Managed Models Mostly and Some Unmanaged Models: This LED indicates the status of the power inputs. There is an output screw terminal that can be connected as shown in the wiring diagram. The output voltage from the screw terminal marked ‘OK’ will be the same as the applied switch input voltage. The output will be ON when both the PI and P2 terminals have power applied to them. It will be OFF if either input does not have power or the switch software is not running.
From PLC Input LED
5MS-MDM Models Only: This LED indicates status of the Discrete “From PLC” input on the modem. There is an input screw terminal that can be connected as shown in the diagram. When voltage is applied to the From PLC input the LED will be ON. When no voltage is applied the LED will be OFF.
To PLC Output LED
5MS-MDM Models Only: This LED can indicate Power Status or Modem Connection status. There is an output screw terminal. That can be connected as shown in the wiring diagram. . The output voltage from the screw terminal marked ‘OK’ will be the same as the applied switch input voltage. In “OK output” mode the output will be ON when both P1 and P2 terminals have power applied to them. It will be OFF if either input does not have power or the switch software is not running. In “Carrier Detect” mode the output will be ON when the CD LED is ON and will be OFF when the CD LED is OFF.
CD LED
5MS-MDM Models Only: The CD LED indicates when there is a carrier (successful connection) established between the SL-5MS-MDM and another modem. When OFF the connection is not established, and when ON the Carrier is established.
RD LED
5MS-MDM Models Only: The RD LED flashes when the SL-5MS-MDM is receiving data from the phone line port. Flashing on this LED when the CD LED is OFF could indicate a Ring coming in from a calling device. When the CD LED is ON and the RD LED is flashing will indicate communication coming in from the remote device.
TD LED
5MS-MDM Models Only: The TD LED will flash on as the SL-5MS-MDM transmits data out to the modem. The flashing of TD LED while the CD LED is ON will indicate communications between the SL-5MS-MDM and device connected to the other modem.
Sixnet Slim Line Switch Installation Guide
Page 7 of 30
Page 8
Section 3
Installation These industrial Ethernet switches can be snapped onto a standard DIN rail (EN50022) or screwed directly to a flat panel. Refer to the mechanical drawings below to properly mount your switch.
Overview
Note: Make sure to allow enough room to route your Ethernet copper or fiber optic cables.
SL- or SLX-#ES models in Lexan case:
1
Mounting
2
Recommended DIN rail mounting steps: 1. Hook the top back of the unit over the DIN rail. 2. Push the bottom of the unit towards the DIN rail until it snaps into place.
B
Removal
A
Recommended DIN rail removal steps: A. Insert screwdriver into DIN clip and pry until the bottom of the unit releases from the din rail. B. Unhook the top of the unit and remove it from the DIN rail.
Sixnet Slim Line Switch Installation Guide
Page 8 of 30
Page 9
SL- or SLX-#ES models in metal case:
1
Mounting
2
Recommended DIN rail mounting steps: 1. Hook the top back of the DIN rail clip on the unit over the din rail. 2. Push the bottom of the unit towards the DIN rail until it snaps into place.
C
A
Removal
B
Recommended DIN rail removal steps: A. Push the whole unit down to free the bottom of the DIN rail clip. See blue circle area. B. Pull the bottom of the unit away from the DIN rail. C. Unhook the top of unit and remove it from the DIN rail.
Sixnet Slim Line Switch Installation Guide
Page 9 of 30
Page 10
SL- or SLX-#MS models in metal case with plastic DIN rail clip (older models):
1
Mounting
2
Recommended DIN rail mounting steps: 1. Hook the top back of the unit over the DIN rail. 2. Push the bottom of the unit towards the DIN rail until it snaps into place.
Removal B
A
Recommended DIN rail removal steps: A. Insert screwdriver into DIN clip and pry until the bottom of the unit releases from the din rail. B. Unhook the top of the DIN clip and remove the unit from DIN rail.
Sixnet Slim Line Switch Installation Guide
Page 10 of 30