Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 2 of 3

Slim Line (SL/SLX) Series Industrial Ethernet Switches & Media Converter Installation Guide, pages 11 to 20

Pages 11 to 20 of 30

The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sixnet 8-port SL-8-ES-1

Page 11

SL/SLX-#MS and -#MG models in metal case with metal DIN rail clip:

1

Mounting

2

Recommended DIN rail mounting steps: 1. Hook the top back of the DIN rail clip on the unit over the din rail. 2. Push the bottom of the unit towards the DIN rail until it snaps into place.

C

A

Removal

B

Recommended DIN rail removal steps: A. Push the whole unit down to free the bottom of the DIN rail clip. See blue circle area. B. Pull the bottom of the unit away from the DIN rail. C. Unhook the top of unit and remove it from the DIN rail.

Sixnet Slim Line Switch Installation Guide

Page 11 of 30

Page 12

0.40" (1.02 cm) Typical for SC or ST fiber

Removable Screw Block

1.01" [2.57 cm]

6/8/9 Ports

2/3/5 Ports 3.95" [10.03 cm]

Snaps to standard DIN rail EN50022 (35 mm)

2.90" [7.35 cm]

1.98" [5.02 cm]

Dia. 0.15" (0.38 cm) Use for direct panel mounting to a flat surface

4.20" [10.67 cm]

1.98" [5.02 cm]

1.01" [2.57 cm] 3.26" [8.28 cm]

1.50" [3.81 cm]

1.00" [2.54 cm]

0.06" [0.15 cm]

Mechanical Dimensions for SL-2/3/5/6/8/9ES-1/2/3 in Lexan Packaging

SLX

0.175" [0.44 cm]

2/3/5 Ports 4.50" [11.43 cm]

0.40" (1.02 cm) Typical for SC or ST fiber

6/8/9 Ports

4.00" [10.16 cm]

4.35" [11.05 cm]

0.30" [0.76 cm]

Snaps to standard DIN rail EN50022 (35 mm)

Use for direct panel mounting to a flat surface with up to #8 screw for older units or up to #12 for newer units (see guide to right)

Removable for direct panel mounting 0.55" [1.40 cm] 1.10" [2.79 cm]

1.60" [4.06 cm]

0.80" [2.03 cm]

1.50" [3.81 cm] 3.00" [7.62 cm]

2.25" [5.71 cm]

C

2.25" [5.71 cm]

0.39" [0.99 cm]

Panel mounting ears on newer models accept up to a #12 screw

Removable Screw Block

Direct to panel mounting guide

Mechanical Dimensions for SLX-2/3/5/6/8/9ES-1/2/3 in Metal Packaging

Sixnet Slim Line Switch Installation Guide

Page 12 of 30

Page 13

Metal DIN Clip (newer models) Plastic DIN Clip (older models)

5.05" [12.83 cm]

ST Fiber

Removable DIN clip for direct panel mounting Panel mounting ears accept up to a #6 screw on older models w/ plastic DIN clip (see to the right for newer models) 0.15" [0.38 cm]

Console Port(s)

1.90" [4.83 cm]

1.60" [4.07 cm]

C

0.39" [0.99 cm]

Direct to panel mounting guide for newer models

0.43"

3.82"

For #6 screw: 5.05" [12.83 cm] For #8 screw: 5.10" [12.95 cm] For #10 screw: 5.15" [13.08 cm] For #12 screw: 5.20" [13.21 cm]

SC Fiber

Snaps to standard DIN Rail EN50022 (35 mm)

Panel mounting ears on newer models (w/ metal DIN clip) accept up to a #12 screw

5.20" [13.21 cm]

Removable Screw Block

4.70" [11.94 cm] 1.07" [2.71 cm]

1.92" [4.88 cm]

2.60" [6.60 cm]

Typ. for SC or ST Fiber 0.40" [1.02 cm]

0.51" [1.29 cm]

#12 screw #10 screw #8 screw #6 screw

0.53" [1.36 cm]

2.60" [6.60 cm]

0.80" [2.04 cm]

5 Port 8 Port [9.70 cm] [1.10 cm] Mechanical Dimensions for SL/SLX-5/8MS-1/4/5 with up to 2 Fiber Ports

Removable Screw Block 4.70" [11.93 cm] 5.20" [13.21 cm] 5.05" [12.83 cm]

Removable DIN clip for direct panel mounting Panel mounting ears accept up to a #6 screw on older models (see to the right for newer models) 0.15" [0.38 cm] 1.90" [4.83 cm]

1.00" [2.54 cm] 2.00" [5.08 cm]

Snaps to standard DIN Rail EN50022 (35 mm)

2.60" [6.60 cm]

C

2.60" [6.60 cm]

Console Port(s)

3.82" [9.70 cm]

0.39" [0.99 cm]

For #6 screw: 5.05" [12.83 cm] For #8 screw: 5.10" [12.95 cm] For #10 screw: 5.15" [13.08 cm] For #12 screw: 5.20" [13.21 cm]

1.92" [4.88 cm]

Panel mounting ears on newer models accept up to a #12 screw

#12 screw #10 screw #8 screw #6 screw

Direct to panel mounting guide for newer models

Mechanical Dimensions for SL/SLX-5MS-MDM-1

Sixnet Slim Line Switch Installation Guide

Page 13 of 30

Page 14

1.92" [4.88 cm]

Removable Screw Block

Snaps to standard DIN Rail EN50022 (35 mm)

SC Fiber ST Fiber 5.05" [12.83 cm] for #6 screw

5.20" [13.21 cm]

Removable DIN clip for direct panel mounting Panel mounting ears accept up to a #6 screw on older models (see to the right for newer models) 1.90" [4.83 cm]

0.80" [2.04 cm] 1.60" [4.07 cm]

2.60" [6.60 cm]

Console Port(s)

3.82" [9.70 cm]

2.60" [6.60 cm]

0.39" [0.99 cm]

For #6 screw: 5.05" [12.83 cm] For #8 screw: 5.10" [12.95 cm] For #10 screw: 5.15" [13.08 cm] For #12 screw: 5.20" [13.21 cm]

0.40" [1.02 cm] typical

Panel mounting ears on newer models accept up to a #12 screw

0.15" [0.38 cm]

#12 screw #10 screw #8 screw #6 screw

Direct to panel mounting guide for newer models

Mechanical Dimensions for SL/SLX-8ES-6/7 with 3 Fiber Ports

1.92" [4.88 cm]

Removable Screw Block

Snaps to standard DIN Rail EN50022 (35 mm)

SC Fiber ST Fiber 5.05" [12.83 cm] for #6 screw

5.20" [13.21 cm]

Removable DIN clip for direct panel mounting Panel mounting ears accept up to a #6 screw on older models (see to the right for newer models) 1.90" [4.83 cm]

0.80" [2.04 cm] 1.60" [4.07 cm]

2.60" [6.60 cm]

Console Port(s)

3.82" [9.70 cm]

2.60" [6.60 cm]

0.39" [0.99 cm]

For #6 screw: 5.05" [12.83 cm] For #8 screw: 5.10" [12.95 cm] For #10 screw: 5.15" [13.08 cm] For #12 screw: 5.20" [13.21 cm]

0.40" [1.02 cm] typical

Panel mounting ears on newer models accept up to a #12 screw

0.15" [0.38 cm]

#12 screw #10 screw #8 screw #6 screw

Direct to panel mounting guide for newer models

Mechanical Dimensions for SL/SLX-8MS-8/9 with 4 Fiber Ports

Sixnet Slim Line Switch Installation Guide

Page 14 of 30

Page 15

5.20" [13.21 cm]

2.60" [6.60 cm]

0.35" [0.88 cm]

Typical for SFP Xcvrs 0.50" [1.27 cm]

Removable Snaps to Screw Block standard DIN Rail SFP Fiber EN50022 Ports (35 mm) Removable DIN clip for direct panel mounting

5.05" [12.83 cm]

Console Ports

Panel mounting ears accept up to a #6 screw on earlier models and up to a #12 screw on newer models.

4.70" [11.94 cm]

0.15" [0.38 cm]

1.88" [4.78 cm] 3.80" [9.65 cm]

For #6 screw: 5.05" [12.83 cm] For #8 screw: 5.10" [12.95 cm] For #10 screw: 5.15" [13.08 cm] For #12 screw: 5.20" [13.21 cm]

2.60" [6.60 cm]

1.92" [4.88 cm]

Panel mounting ears on newer models accept up to a #12 screw

0.39" [0.99 cm]

#12 screw #10 screw #8 screw #6 screw

2.75" [6.98 cm] 1.37" [3.49 cm]

Direct to panel mounting guide for newer models

Mechanical Dimensions for SL/SLX-8MG with 8 Gigabit Ports

2.76" [7.01 cm]

5.52" [14.02 cm]

2.76" [7.01 cm]

Typical for SFP Xcvrs 0.50" [1.27 cm]

2.15" [5.46 cm]

Snaps to standard DIN Rail EN50022 (35 mm)

Removable Screw Block

Removable DIN clip for direct panel mounting

Panel mounting ears accept up to a #12 screw

0.39" [0.99 cm]

#12 screw #10 screw #8 screw #6 screw

6.02" [15.29 cm]

Panel mounting ears accept up to a #12 screw

0.35" [0.88 cm]

2.15" [5.46 cm]

1.63" [4.13 cm]

Direct to panel mounting guide

Mechanical Dimensions for SLX-10MG-1

Sixnet Slim Line Switch Installation Guide

Page 15 of 30

Page 16

2.76" [7.01 cm]

5.52" [14.02 cm]

2.76" [7.01 cm]

Typical for SFP Xcvrs 0.50" [1.27 cm]

2.15" [5.46 cm]

Snaps to standard DIN Rail EN50022 (35 mm)

Removable Screw Block

Panel mounting ears accept up to a #12 screw

0.39" [0.99 cm]

#12 screw #10 screw Direct to panel #8 screw mounting guide #6 screw

6.02" [15.29 cm]

Removable DIN clip for direct panel mounting

Panel mounting ears accept up to a #12 screw

0.35" [0.88 cm]

2.13" [5.40 cm]

2.15" [5.46 cm]

Mechanical Dimensions for SLX-16MS-1

2.76" [7.01 cm]

5.52" [14.02 cm]

2.76" [7.01 cm]

0.35" [0.88 cm]

Typical for SFP Xcvrs 0.50" [1.27 cm]

2.15" [5.46 cm]

Snaps to standard DIN Rail EN50022 (35 mm)

Removable Screw Block

Removable DIN clip for direct panel mounting

6.02" [15.29 cm]

Panel mounting ears accept up to a #12 screw 2.15" [5.46 cm]

#12 screw #10 screw #8 screw #6 screw

Panel mounting ears accept up to a #12 screw

0.39" [0.99 cm]

Direct to panel mounting guide

2.88" [7.31 cm]

Mechanical Dimensions for SLX-18MG-1

Sixnet Slim Line Switch Installation Guide

Page 16 of 30

Page 17

The metal packaged models allow you to choose the mounting method that best fits your requirements. (Note: Not all methods are available on all models. Refer to the mechanical diagrams for details.) Vertical snap-on DIN rail mounting for quickest installation and optimal utilization of your rail space.

Vertical screw-topanel mounting for better shock and vibration resistance.

Flat screw-to-panel mounting for low profile orientation in shallow boxes plus best shock and vibration resistance.

Overview of Optional Mounting Methods

Important Notes about Thermal Performance: The Slim Lines switches with metal cases use an innovative technique to remove excess heat from the product and its components. This technique effectively utilizes the heavygauge all-aluminum case as a large heat-sink. Therefore, you may notice the case becoming warm during operation (especially with large loads such as all ports linked and active). This is normal operation. For best performance it is recommended that a DIN rail spacer (such as an end clamp) be used between the switch and adjacent devices. This will leave an air gap for best heat dissipation off the case. Also, do not block the air slots. For best thermal performance when direct panel mounting to a metal surface, you may use a thermal compound or pad between the mounting face and the mounting surface. This will reduce any air gaps and optimize the transfer of heat from the case to the mounting surface.

Notes and Recommendations for Best Heat Dissipation

Sixnet Slim Line Switch Installation Guide

Page 17 of 30

Page 18

Section 4 Overview

Power and Output Wiring These industrial Ethernet switches can be powered from the same DC source that is used to power your other devices. A voltage in the range of 10 to 30 VDC needs to be applied between the P1 (plus) terminal and the Minus terminal as shown in the diagrams on the next page. The chassis screw terminal should be tied to panel or chassis ground. To reduce down time resulting from power loss, these industrial Ethernet switches can optionally be powered redundantly with a second power supply as shown in the diagrams. The managed models also have an “OK” output that can be tied to a PLC input or other device to indicate when there is a power loss. When ON, this output will source the same voltage that is applied to the switches power terminals. See the wiring diagrams on the next page.

Screw Torque

WIRING WARNINGS

When tightening the screws be careful to tighten to a max. torque of 5 in/lb (0.57 Nm).

BEFORE PERFORMING ANY WIRING TO THESE SWITCHES MAKE SURE … • THE AREA IS CURRENTLY NONHAZARDOUS (ESPECIALLY WHEN WORKING IN CLASS I, DIV 2 OR ZONE 2 HAZARDOUS LOCATIONS) • TO TURN OFF THE POWER TO THE SWITCH • TO UNPLUG THE SCREW TERMINAL BLOCK (This is especially important on the units that have a metal case as shown below. Connecting or disconnecting wires to the screw block when it is in place and the power is turned on can allow the screwdriver to short the power to the case.)

TO PREVENT SHORTING THE POWER TO THE CASE ALWAYS UNPLUG THE SCREW TERMINAL BLOCK BEFORE PERFORMING ANY WIRING!

UL Requirements

To meet the requirements for UL you must do one of the following: 1. Install a 3.33 Amp maximum fuse at the input of the switch. OR 2. Use a Class 2 rated power supply to power the switch.

Sixnet Slim Line Switch Installation Guide

Page 18 of 30

Page 19

Dual DC Supplies

Single DC Supply Chassis GND (panel)

+ -

Frontofof Front Switch Switch (connectors) (connectors)

Alarm Output Load (opt.)

Chassis GND (panel)

+ -

Alarm Output Load (opt.)

OK P2 P1

OK P2 P1

Single DC Power

Back of Switch (DIN rail)

Redundant DC Power

Power & Alarm Wiring for SL/SLX-5/8MS Managed Switches -------------------------------------------------------

Dual DC Supplies

Single DC Supply Chassis GND (panel) Front of Front of Switch Switch (connectors) (connectors)

Chassis GND (panel)

P2 P1

P2 P1

Single DC Power

Back of Switch (DIN rail)

Redundant DC Power

Power Wiring for SL/SLX-5/8/9ES Unmanaged Switches and SL-2ES Media Converter

Sixnet Slim Line Switch Installation Guide

Page 19 of 30

Page 20

Single DC Supply Chassis GND (panel)

PLC or Other Device IN

Frontofof Front Switch Switch (connectors) (connectors)

Dual DC Supplies Chassis GND (panel)

PLC or Other Device IN

OUT

OUT

From To P2 PLC PLC +

P1 +

From To P2 PLC PLC +

P1 +

IN OUT IN

IN

IN OUT IN

IN

Single DC Power

Back of Switch (DIN rail)

Redundant DC Power

Power & PLC Wiring for SL/SLX-5MS-MDM Ethernet Modem -------------------------------------------------------

One DC Supply

+ -

(optional)

Back of Switch (DIN rail)

Chassis GND (panel)

(optional)

P1 P2 OK

P1 P2 OK

Single DC Power

Alarm Output Load

+ -

Alarm Output Load

+ -

Chassis GND (panel)

Dual DC Supplies

Front Frontofof Switch Switch (connectors) (connectors)

Redundant DC Power

Power & Alarm Wiring for SL/SLX-8MG Managed Switches

Sixnet Slim Line Switch Installation Guide

Page 20 of 30