Page 21
+ Front of Front of Switch Switch (connectors) (connectors)
P2 P1
Dual DC Supplies Alarm Output Load (opt.) Chassis GND is made through the DIN rail mounting
OK
Alarm Output Load (opt.)
+ -
Single DC Supply
Single DC Power
P2 P1
OK
Back of Switch (DIN rail)
Redundant DC Power
Power and Alarm Wiring For SL/SLX-6ES Unmanaged Switches -------------------------------------------------------
Dual DC Supplies
+ -
Alarm Output Load (opt.)
+ -
Back of Switch (DIN rail)
OK
Chassis GND (panel)
P2 P1
Single DC Power
+ -
Single DC Supply Alarm Output Load (opt.)
OK
P2 P1
Chassis GND (panel) Front of of Front Switch Switch (connectors) (connectors)
Redundant DC Power
Power and Alarm Wiring for SLX-10/16/18-Mx Managed Switches
Sixnet Slim Line Switch Installation Guide
Page 21 of 30
Page 22
Section 5
Communication Ports Wiring
Overview
These industrial Ethernet switches provide connections to standard Ethernet devices such as PLCs, Ethernet I/O, industrial computers and much more. Three types of communication ports may be found on these switches: RJ45 (copper) Ethernet ports, fiber optic Ethernet ports and a serial or USB console port for management (managed models).
RJ45 Ethernet Wiring
Use data-quality (not voice-quality) twisted pair cable rated category 5 (or better) with standard RJ45 connectors. For best performance use shielded cable. Straight through or crossover RJ45 cable can be used regardless of the device the switch is to be connected to as all the ports are capable of auto-mdi/mdix-crossover detection. The RJ45 Ethernet port connector bodies on these products are metallic and are connected to the Chassis GND terminal. Therefore, shielded cables may be used to provide further protection. To prevent ground loops, the cable shield should be tied to the metal connector body at one end of the cable only. Electrical isolation is also provided on the Ethernet ports for increased reliability.
For Reference Only. Either cable wiring will work!
Straight-thru Cable Wiring Pin 1 Pin 1 Pin 2 Pin 2 Pin 3 Pin 3 Pin 6 Pin 6
Cross-over Cable Wiring Pin 1 Pin 3 Pin 2 Pin 6 Pin 3 Pin 1 Pin 6 Pin 2
Ethernet Plug & Connector Pin Positions
RJ45 Cable Distance
The maximum cable length for 10/100/1000BaseT is typically 100 meters (328 ft.).
Ethernet Fiber Wiring Guidelines
Depending on the model these industrial Ethernet switches may have up to four fiber optic ports. All 100 Mbps fiber ports are available with dual SC or ST style connectors. They are also available with multimode, singlemode, long-haul (for connections up to 120+ km) or special-application transceivers. Refer to the technical specifications for details. All 1000 Mbps fiber ports are provided as mini-gbic SFP (small form pluggable). These accept plug in fiber transceivers that typically have an LC style connector. They are available with multimode, singlemode, long-haul (for connections up to 80+ km) or specialapplication transceivers. Refer to the technical specifications for details. For each fiber port there is a transmit (TX) and receive (RX) signal. When making your fiber optic connections, make sure that the transmit (TX) port of the switch connects to the receive (RX) port of the other device, and the receive (RX) port of the switch connects to the transmit (TX) port of the other device. Use standard fiber optic wiring techniques (not covered by this manual) to make your connections. The corresponding ACT/LNK LED will be ON solid or flashing when you have made a proper connection. For more fiber optic guidelines go to: http://www.sixnet.com See images below for typical fiber optic port placement on these switches.
Sixnet Slim Line Switch Installation Guide
Page 22 of 30
Page 23
Typical Fiber Ports on Unmanaged Models
Typical SC style connector on a SL-5ES-2/3SC
Typical ST style connector on a SL-5ES-2/3ST
Typical Fiber Ports on Managed Models
Typical SC style connector on a SLX-8xS-
Typical SC style connector on a SLX-5MS-4/5SC
Typical ST style connector on a SLX-5MS-4/5ST
Typical Fiber Ports on an SL-8MG
SLX-8MG with no transceivers installed
Sixnet Slim Line Switch Installation Guide
SLX-8MG with four transceivers installed
Page 23 of 30
Page 24
Duplex Operation
The RJ45 ports will auto-sense for Full or Half duplex operation, while the fiber ports are configured for full duplex operation. Note: Fiber devices with half duplex settings should still communicate with the switch. If otherwise then please contact Sixnet. On managed models the duplex setting is software configurable.
Verifying Connectivity
After all Ethernet and/or fiber connections are made, check the LED’s corresponding to the ports that each of the devices are connected to. Ensure that for each port that is in use, the LED is on or blinking. If a port LED is off, go back and check for connectivity problems between that port and the network device connected to that particular port. In addition, the color of the LED should indicate the speed for which your device is connected at (see prior section on LEDs).
Telephone Port Wiring
A standard cross-wired telephone patch cable should be used to connect to the phone line provided by the phone company. Tip and Ring are the only two pins used on the Ethernet Land-Line modem.
(MDM models)
Telephone Ports on Modem Models
Sixnet Slim Line Switch Installation Guide
Page 24 of 30
Page 25
Serial Console Port Wiring
An optional way to configure the switch is through the RJ45 console RS232 port. Use a DB9F to RJ45F adapter along with a RJ45 male to RJ45 male straight-thru-wired patch cable to make a connection between a com port on your PC (DB9 male) and the RS232 port of the Managed Switch (RJ45 female). Contact Sixnet or your switch vendor to purchase this adapter as an accessory. A typical DB9F to RJ45F adapter should be wired as follows: RJ45F Pin # 1 2 3 4 5 6 7 8
USB Console Port Wiring
Switch Signal Name RI/DSR in DCD in DTR out GND RXD in TXD out CTS in RTS out
Adapter Signal DB9F Name Pin # DTR out 4 N/C n/c DSR in 6 GND 5 TXD out 3 RXD in 2 RTS out 7 CTS in 8
Newer models of these switches may also have an USB port instead of or in addition to the RS232 port. Use a standard USB cable with a mini-USB plug on one end and an A-typeUSB plug on the other end. The A-type plug goes into a standard USB port on a computer. The mini-USB plug goes into the USB port on the switch. Refer to the software user manual for how to use this USB port.
RS232 RJ45F
RS232 RJ45F Mini-USB Mini-USB
The RS232 and/or USB ports may located on the bottom edge or front face of the switch
Sixnet Slim Line Switch Installation Guide
Page 25 of 30
Page 26
Section 6 Technical Specs
Technical Specifications Here are the hardware technical specifications for the industrial Ethernet switches covered by this manual. For the managed models, refer to the software user manual or datasheet for complete software specifications. Note: These specifications are subject to change. Contact Sixnet for the latest details.
General Specifications: Ethernet switch type Operating mode Devices supported Protocols (managed models only) Industrial protocols supported Standards (depends on model) Management interfaces (managed models only) Open source linux (managed models only)
MAC addresses Memory bandwidth Latency for 10 Mbps Latency for 100/1000 Mbps Ethernet isolation Management serial port (managed models only)
Unmanaged or managed with up to 9 ports Store and forward, wire-speed switching, non-blocking All IEEE 802.3 compliant devices are supported SNMPv1/v2/v3, RMON, DHCP, SNTP, TFTP, STP, RSTP, QoS/CoS/ToS/DS, IGMPv1/v2, VLAN (tag and port based), HTTP, HTTPS (SSL & TSL), Telnet, SSH and more Modbus/TCP, EtherNet/IP, PROFInet, Foundation Fieldbus HSE and others IEEE 802.3, 802.3u, 802.3ab/z, 802.3x, 802.1D/w, 802.1p, 802.1Q and others Web (see online demo), text (Telnet & SSH), CLI (command line interface) and SNMP (see software manual for supported MIBs) The Linux Advantage – Contact Sixnet for more information 1024 on unmanaged (ES) models; 2048 on managed (MS)models; 8192 on Gigabit (MG) models 3.2 Gbps on ES & MS models; 32 Gbps on MG models 16 us + frame time (typical) Varies on load and settings <5 us + frame time (typical) 1500 VRMS 1 minute RS232 (TXD, RXD and GND), 9600, 8, N, 1 fixed and/or mini-USB
Copper RJ45 Ports: (10/100 Mbps or 10/100/1000 Mbps) Copper ports Speed Protocols supported Auto-crossover Auto-sensing operation Auto-negotiating Auto-polarity Flow control Ethernet isolation Plug and play Cable requirements Max. cable distance
Shielded RJ45 10/100 Mbps or 10/100/1000 Mbps (depending on model) All standard IEEE 802.3 Yes, allows you to use straight or cross wired cables Yes, Full and half duplex Yes, 10BaseT and 100BaseT Yes, on the TD and RD pair Automatic 1500 VRMS 1 minute Yes Twisted pair (Cat. 5 or better) (shielded recommended) 100 meters
Sixnet Slim Line Switch Installation Guide
Page 26 of 30
Page 27
SC or ST Fiber Ports: (100BaseF multimode or singlemode) 100BaseF ports Fiber port mode Fiber port connector Optimal fiber cable Center wavelength Multimode
Singlemode
Singlemode long haul
Nominal max. distance (full duplex) (see web for details) Half and full duplex Ethernet compliance Eye safety
Up to 4 Multimode (mm) or Singlemode (sm) Duplex SC or ST 50/125 or 62.5/125 µm for mm; 9/125 µm for sm 1300 nm (other wavelengths available) Links up to 4 km typ.; 1310 nm; use with 50 or 62.5/125 um fiber > Transmitter power (dB): -21 min, -17 typ, -14 max > Receiver sensitivity (dB): -34 typ, -31 max Links up to 20 km typical; 1310 nm; use with 9/125 um fiber > Transmitter power (dB): -15 min, -11 typ, -8 max > Receiver sensitivity (dB): -36 typ, -31 max Links up to 40 km typical; 1310 nm; use with 9/125 um fiber > Transmitter power (dB): -5 min, -3 typ, -0 max > Receiver sensitivity (dB): -36 typ, -34 max 4 km with multimode; 20 km with singlemode; up to 120 km with long haul singlemode Full duplex on unmanaged models; Software configurable on managed models 100BaseF IEC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11
SFP Mini-Gbic SFP (pluggable) Ports: (many types available) Note: On the Gigabit (MG) models these ports are pluggable and accept many different types of pluggable SFP (Mini-Gbic) transceiver modules for Gigabit fiber connections. Gigabit SFP ports Up to 4 Port types supported Gigabit fiber multimode, fiber singlemode, fiber long-haul singlemode, fiber single-strand and more Note: 100 Mbps fiber transceiver modules are also supported on these ports. Fiber port connector LC typically for fiber (depends on module) Optimal fiber cable Typical 50 or 62.5/125 µm for multimode (mm); Typical 8 or 9/125 µm for singlemode (sm) Fiber wavelength (typical) 850 nm for mm; 1310 nm for sm; 1550 for long haul sm TX output power See fiber transceiver datasheet for details. RX input sensitivity Max. distance (full duplex) Up to 80+ km with long haul singlemode modules Half and full duplex Software Configurable Ethernet compliance 1000BaseT and 1000BaseF (SX/LX/LH) Eye safety IEC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11
Note: See SFP fiber optic transceiver datasheet for complete specifications. Also, other fiber transceivers may be available for special requirements such as longer distances, single strand (BiDi) or other special applications. Contact Sixnet for details.
Sixnet Slim Line Switch Installation Guide
Page 27 of 30
Page 28
Industrial Telephone Modem (SL-5MS-MDM Only) Maximum data rates Compatibility Data compression Error correction Ringer Jacks Command sets Country compatibility Telecom ratings
56 Kbps V.90, V.34, V.32, V.32 bis, V.22, V.22 bis, V.21 V.42 bis V.42 MNP or LAP 0.3 2 RJ11 (phone and line) Standard AT and S register World-wide (100+ countries) FCC Part 68; Industry Canada CS03-8; CTR21 (98/482/EC); ACA TS 001 and ACA TS 002
“PLC” Input and Output (SL-5MS-MDM Only) PLC / Alarm output voltage Maximum current output PLC / Trigger input voltage Typically current input
Same as switch input power voltage 0.5 Amp 10-30 VDC 6.5 mA @ 24 VDC
“OK” Alarm Output (managed models only) “OK” Output Voltage Maximum current output
ON if P1 and P2 have power and switch software is running Same as switch input voltage 0.5 Amp
Power Input: Power input Input power (typical with all ports active at 100 Mbps)
Redundant Input Terminals 2.0 W (2-port converter with 1 fiber), 2.0 W (5-port unmanaged w/ 0 fiber), 3.0 W (5-port unmanaged w/ 1 fiber), 5.0 W (6-port unmanaged w/ 2 fiber), 4.0 W (8-port unmanaged w/ 0 fiber), 5.0 W (9-port unmanaged w/ 1 fiber), 8.0 W (8-port unmanaged w/ 3 fiber)
Input voltage (all models) Reverse power protection Transient protection Spike protection
Sixnet Slim Line Switch Installation Guide
3.6 W (5-port managed w/o fiber), 4.8 W (5-port with phone modem), 5.6 W (5-port managed w/ 2 fiber), 4.3 W (8-port managed w/ 0 fiber), 6.3 W (8-port managed w/ 2 fiber), 9.0 W (8-port managed w/ 4 fiber), 12 W (8-port man. gigabit w/ 0 fiber) 15 W (8-port man. gigabit w/ 4 fiber), 5.0 W (10-port man. gigabit w/ 0 fiber), 7.0 W (10-port man. gigabit w/ 2 fiber), 7.0 W (16-port man. gigabit w/ 0 fiber), 8.0 W (18-port man. gigabit w/ 0 fiber), 10 W (18-port man. gigabit w/ 2 fiber)
10-30 VDC (continuous) Yes 15,000 watts peak 5,000 watts (10x for 10 uS)
Page 28 of 30
Page 29
Environmental and Compliances: Operating temperature range
SL-2/5/6/8/9ES models: -10 to +60°C (cold startup at -10°C) SL-5/8MS models: -10 to +60°C (cold startup at -10°C) SL/SLX-5MS-MDM: -40 to +75°C (cold startup at -40°C) SL/SLX-8MG: -40 to +75°C (cold startup at -40°C) SLX-5/6/8/9ES-1/2/3/4/5 models: -40 to +85°C (cold startup at -40°C) SLX-8ES-6/7 models: -40 to 75° C (cold startup at -40°C) SLX-5/8MS models: -40 to +75°C (cold startup at -40°C) SLX-10/18MG-1 model -40 to +75°C (cold startup at -40°C) SLX-16MS-1 model -40 to +75°C (cold startup at -40°C)
Storage temperature range Humidity (non-condensing) Vibration, shock & freefall Electrical safety EMC: emissions and immunity Hazardous Locations Eye safety (fiber models) MTBF RoHS and WEEE ISO9001:2000
Contact Sixnet if wider ranges are needed. -40 to +85 °C 5 to 95% RH Contact Sixnet for optional conformal coating. IEC68-2-6, -27, -32 UL508/CSA C22, EN61010-1, CE FCC part 15, ICES-003; EN55022 and/or IEC61326-1 and/or EN61000-6-2/4 UL1604, CSA C22.2/213 (Class I, Div.2) ; EN50021/EN60079-15 (Zone2), CE (ATEX) IEC60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11 Mean Time Between Failure: >1,000,000 hours typical per MIL-HDBK-217F2 Ground Benign at 35˚C RoHS (Pb free) and WEEE compliant Certified “Total Quality” company
Mechanical: Ingress protection Packaging and protection Dimensions (L x W x H) Weights (typical)
IP30 (all models) UL94V0 Lexan plastic for all plastic cased units. Aluminum w/ protective finish for all metal cased units. See mechanical diagrams for details SL-2ES-2/3 and SL-5ES-1/2/3 in Lexan case – 4 oz (0.11 kg) SLX-5ES-1/2/3 in metal case – 6 oz (0.11 kg) SL/SLX-5MS-1/4/5 in metal case – 8 oz (0.23 kg) SL-5MS-MDM managed – 11 oz (0.31 kg) SL-6/8/9ES-1/2/3/4/5 in Lexan case – 6 oz (0.17 kg) SLX-6/8/9ES-1/2/3/4/5 in metal case – 8 oz (0.23 kg) SL/SLX-8MS-1/4/5 in metal case – 10 oz (0.28 kg) SL/SLX-8xS-6/7/8/9 in metal case – 11 oz (0.31 kg) SL-8MG-1 without fiber transceivers – 16 oz (0.45 kg) SL-8MG with 4 fiber transceivers – 18 oz (0.50 kg) SLX-10MG-1 in metal case – 12 oz (0.34 kg) SLX-16MS-1 in metal case – 16 oz (0.45 kg) SLX-18MG-1 in metal case – 16 oz (0.46 kg)
Sixnet Slim Line Switch Installation Guide
Page 29 of 30
Page 30
Section 7 Service Information
Service Information We sincerely hope that you never experience a problem with any Sixnet product. If you do need service, call Sixnet at (518) 877-5173 and ask for Applications Engineering. A trained specialist will help you to quickly determine the source of the problem. Many problems are easily resolved with a single phone call. If it is necessary to return a unit to us, an RMA (Return Material Authorization) number will be given to you. Sixnet tracks the flow of returned material with our RMA system to ensure speedy service. You must include this RMA number on the outside of the box so that your return can be processed immediately. The applications engineer you are speaking with will fill out an RMA request for you. If the unit has a serial number, we will not need detailed financial information. Otherwise, be sure to have your original purchase order number and date purchased available. We suggest that you give us a repair purchase order number in case the repair is not covered under our warranty. You will not be billed if the repair is covered under warranty. Please supply us with as many details about the problem as you can. The information you supply will be written on the RMA form and supplied to the repair department before your unit arrives. This helps us to provide you with the best service, in the fastest manner. Normally, repairs are completed in two days. Sometimes difficult problems take a little longer to solve. If you need a quicker turnaround, ship the unit to us by air freight. We give priority service to equipment that arrives by overnight delivery. Many repairs received by mid-morning (typical overnight delivery) can be finished the same day and returned immediately. We apologize for any inconvenience that the need for repair may cause you. We hope that our rapid service meets your needs. If you have any suggestions to help us improve our service, please give us a call. We appreciate your ideas and will respond to them. For Your Convenience: Please fill in the following and keep this manual with your Sixnet system for future reference: P.O. #:__________________ Date Purchased: ___________________ Purchased From:______________________________________________
Product Support
To obtain support for Sixnet products: Latest product info: http://www.sixnet.com Phone: +1 (518) 877-5173 Fax: +1 (518) 877-8346 E-mail: mailto: support@sixnet.com Mailing address: Sixnet Technology Park, 331 Ushers Road, Ballston Lake, NY 12019
Sixnet Slim Line Switch Installation Guide
Page 30 of 30