Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Industrial Control Relays Type X Class 8501

Manual · Square D

Industrial Control Relays Type X Class 8501

Manual12 pagesPDF 355 KB

Catalog for Square D Class 8501 Type X NEMA industrial control relays, including the XO30 and XO40: ordering, ratings and dimensions.

Download the PDF355 KB

Covers · 4 models

The models it covers

Summary

What is in it

Square D catalog for the Class 8501 Type X family of NEMA industrial control relays. It covers AC control relays such as the XO30 and XO40, AC timing, latching and master relays, DC control, latching, timing and utility relays, accessories (latch and timer attachments, adder decks, contact cartridges, mounting track, enclosure), voltage codes and how to order, application data with contact ratings, contact arrangements and replacement coils, life-load guidance, product data on isolation and construction, and dimensions.

Its parts

  1. General
  2. Accessories
  3. Application Data
  4. Product Data
  5. Dimensions

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Square D catalog 8501CT9601 (December 1996) for the Class 8501 Type X NEMA industrial control relays, covering the AC control relays such as the XO30 and XO40 along with timing, latching, master, DC and utility versions. It explains ordering, accessories, contact ratings and pole arrangements, replacement coils, contact life and dimensions. It also shows how to convert a contact between normally open and normally closed.

Device
Class 8501 Type X NEMA industrial control relay, AC operated, with plug-in convertible contact cartridges p. 2, 3
Contacts
8501-XO30: 3 normally open; 8501-XO40: 4 normally open (first number after XO is N.O., second is N.C.) p. 2, 3
Contact rating
NEMA A600: 600 VAC spacings, 10 A continuous, 60 A make and 6 A break at 120 VAC inductive p. 8
Coil voltage range
AC operation +10/-15%; DC operation +10/-20% p. 6
Operating times
AC relay: 15 ms pick-up, 16 ms drop-out (average) p. 6
Operating temperature
-40°C to +71°C (-40°F to +160°F) p. 6
Ordering
Class, Type, voltage code and any forms, for example 8501 XO40 V02 Y414 p. 2
Expansion
Basic relay holds 4 cartridges; XB20 or XB40 adder deck makes 6 or 8 poles, a second deck 10 or 12 p. 2, 5
Contact cartridges
XC1 standard (black), XC2 overlapping (red), XC4 master 20 A (blue); logic reed (grey) only in XBR adder decks p. 5, 9
Attachments
XL AC latch, XDL DC latch; XTE On Delay and XTD Off Delay pneumatic timers, 0.2-60 or 5-180 seconds; XJ1 timer lockout cover p. 3, 5
Wiring
Self-lifting pressure connectors take up to two #12-18 AWG stranded copper wires; Form Y414 for ring or spade lugs p. 2, 3
Replacement coil
AC coils: prefix 9998-X followed by a suffix number for the voltage p. 7
Contact construction
Single-throw double-break silver-cadmium-oxide contacts, each isolated from the others; DC rating NEMA P600 p. 9
Enclosure
NEMA Type 1 enclosure Class 9991 Type UE7 for a single relay p. 5

What this manual walks you through

  • Converting a contact between normally open and normally closed p. 2
  • Ordering a relay by class, type, voltage code and form p. 2, 3
  • Choosing AC control, timing, latching and master relays p. 3
  • Choosing DC control, timing, latching and utility relays p. 4
  • Ordering accessories: latches, timers, adder decks, cartridges, track and enclosure p. 5
  • Contact ratings and factory pole arrangements p. 6
  • Finding the replacement AC or DC magnet coil p. 7
  • Understanding contact ratings and estimating contact life p. 8
  • Contact cartridge types, construction and uses p. 9, 10
  • Dimensions and shipping weights p. 11

Good to know

  • For automatic sequencing, NEMA ICS 5-1993 recommends loads under 25% of the 60 A make and 6 A break ratings. p. 8
  • At most 8 N.C. contacts are allowed on 9-12 pole relays. p. 3
  • Up to 6 master cartridges fit a 7 or 8 pole AC relay; none may be used on 9-12 pole AC or DC-operated relays. p. 5
  • With ring lugs, UL Listing holds only with AMP Plasti-Grip #32958 insulated-barrel ring-tongue lugs. p. 2
  • Logic reed cartridges are for resistive loads only. p. 10

Questions this manual answers

How many contacts does a Square D 8501 XO40 relay have?

Four normally open contacts, each convertible to normally closed; adder decks can take it to 8 or 12 poles. p. 2, 3

How do I change a Type X contact from normally open to normally closed?

Remove the cover and T-bar actuator, pull the contact cartridge, turn it 180 degrees, plug it back in and refit the actuator and cover. p. 2

What is the contact rating of a Class 8501 Type X relay?

NEMA A600: 600 VAC spacings, 10 A continuous, and 60 A make with 6 A break at 120 VAC for an inductive load. p. 8

What temperature range can a Type X relay work in?

-40°C to +71°C (-40°F to +160°F). p. 6

What replacement coil fits an 8501 Type X AC relay?

An AC magnet coil numbered 9998-X followed by the suffix number for the coil voltage and frequency. p. 7

The whole text · 2 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12

The file

Revision and size

Revision8501CT9601, December 1996
PublisherSquare D
Pages12
PDF355 KB
TextText from the PDF itself.

The first pages · 3 of 12

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 12
Page 2
Page 2of 12
Page 3
Page 3of 12

More documents · 1

For the same models