Page 1 read from a scan by OCR; it may hold reading errors

TaYail li ace lll 4 rr WW ria nAS

Lighting Control System Catalog

Class 1210

D SQUARE D GROUPE SCHNEIDER

Page 2

Table of Contents Lighting Control System Introduction ...................................................................... Page 4 POWERLINK AS Systems Overview ......................................................................... Page 5 Soft Split System ............................................................. Page 6 LV Switching System ....................................................... Page 6 Time Clock System .......................................................... Page 6 System Components (exploded & applied views) ........... Page 8 Electronic Components QO(B)-AS and EHB-AS Circuit Breakers ........................ Page 9 Control Bus Strips ........................................................... Page 15 Power Interface Module .................................................. Page 17 Class 2 Barrier Kit ........................................................... Page 19 Control Modules .............................................................. Page 20 Panelboards General Information ......................................................... Page 27 Series Ratings ................................................................. Page 28 Dimensions ...................................................................... Page 29 Accessories Desktop Power Supply .................................................... Page 35 Input Expansion Cabinet ................................................. Page 36 Network Options General Information ......................................................... Page 38 LonWorks Gateway ......................................................... Page 39 Software Overview ......................................................................... Page 40 Features (PLK/CMS) ....................................................... Page 41 Power Management Services ............................................... Page 42 Compliance Certification Codes and Standards ...................................................... Page 43 Year 2000 Compliance .................................................... Page 44 Suggested Specifications ...................................................... Page 45

SQUARE D

9/98

3

Page 3

Lighting Control System Introduction POWERLINK AS systems provide the easiest means possible of adding automatic control of electrical power - for lighting control and other applications - to new or existing buildings. Controlling electrical loads - turning them off during unoccupied periods - conserves energy, saves money, and helps the environment. This is not only cost effective, but is often required by federal and state laws in new or renovated buildings. POWERLINK AS systems use innovative circuit breaker technology, and fit into conventional panelboard enclosures. Because no additional enclosures are needed and existing conduits remain undisturbed, POWERLINK AS systems are easily retrofitted into existing facilities and typically have a lower installed cost than conventional contactor or relaybased solutions.

4

The POWERLINK AS lighting control system combines remote switching capabilities and thermal-magnetic overcurrent protection in standard Square D NQOD and NEHB panelboards. The POWERLINK AS system offers the capability to control lighting and other loads to preset time schedules or from external control devices such as wall switches, occupancy sensors, or building management systems. POWERLINK panelboards can also be networked together, set up, and monitored from a remote location. Standard components of the POWERLINK AS system include remotely operated circuit breakers, control bus strips, a power interface module, and Class 2 barrier kit. Optional network and display components include a control module with an POWERLINK AS Panelboard internal time clock, Windows®based software for remote setup and monitoring, and various components for remote communications. The POWERLINK AS system features modular “plug and play” component construction that simplifies design, specifications, and installation. It minimizes wiring and wiring errors, thereby reducing installation time and costs, while enhancing reliability and offering expanded functionality. The modular design also eliminates the need for separate interface cabinets, interposing relays, external control voltage circuits, external time clocks, or contactor devices typically associated with lighting control systems. This is made possible by the integration of remote power switching capability, thermal-magnetic circuit breakers, an internal power supply, communications, an optional internal time clock, and control functions in a single panelboard. The POWERLINK AS system can be configured to meet specific needs for remote power switching and branch circuit overcurrent protection. This makes it ideal for a variety of energy and load management applications. It allows building owners, operators, and plant managers to efficiently manage lighting, as well as many other types of electrical loads, including: • Displays

• Electric strip heaters

• Interior/exterior signage

• Exhaust fans

• Water heaters

• Power drops

• Water coolers

• Appliances

• HVAC units

• Audio/video equipment

Square D has the right lighting control solution, from simple to the sophisticated lighting control applications. Where flexibility and maximum energy savings are important, the POWERLINK AS system is the answer. SQUARE D

9/98

Page 4

POWERLINK AS Systems Overview Saving Time and Money POWERLINK AS systems are substantially less expensive to design and install compared to traditional relay or contactor technology. Design and layout of the POWERLINK AS system are as simple as those of any other panelboard. The POWERLINK AS system can do many things that contactors cannot do, even with elaborate control wiring and auxiliary components. POWERLINK AS capabilities include: • Independent branch circuit control is easy to set and change through software settings. • 42-channel time clock with seven-day repeating schedule and 365-day calendar, including 32 holiday periods, daylight savings adjustment, and astronomical sunrise/sunset capabilities. In short, a full-featured time clock at a very low price.

The modular components of the POWERLINK AS system simply plug into Square D panelboards for ease of installation and operation. There are no wiring harnesses or pigtails. Branch circuit conductors do not have to be routed through other enclosures.

• Automatic time off sweeps - very effective for saving energy. • Central monitoring and control provided by the communications network, which can be industry standard RS-485 or LONWORKS®, or both. • Blink notice - lets you know when lights are about to turn off. • Low voltage Class 2 wiring used for switch inputs - usually does not require conduit and is easy to move. • Easy to change inputs and timed event schedules - a plus for retailers and commercial facilities that frequently change their facility layouts. Reconfiguration is done in minutes, rather than by time-consuming rewiring. • Set up either at the front panel or remotely over the RS-485 network. • Advanced system features, such as telephone override and master switch override and configured input timers. Features like these are difficult and expensive to hard-wire with contactors. • Downloadable firmware for new features.

SQUARE D

9/98

5

Page 5

POWERLINK AS Systems Overview Soft-Split System (no control module) ❏ Factory pre-configured - No field setup is required ❏ External devices control up to three pre-configured zones and 42 circuits

2-Wire Maintained

❏ All breakers in the zone will be controlled by the pre-mapped input

3-Wire Momentary

Zone 1

Zone 2

Zone 3

Master All Switched Circuits

1 +Input - C #157

2 Input + - C #258

3 Input + - C #359

4 Input + - C #460

5 Input + - C #561

6 Input + - C #662

7 Input + - C #763

8 Input + - C #864

❏ Master input controls all switched circuits

EXP

RS-485 (COMMS)

Wiring

2-wire switch + •

❏ External control wiring connects in power interface module

C

•

Zone 2 Circuits 13–30 (Input 2 or 6)

LED

TX RX SH IN- IN+ OUT- OUT+ SH

❏ Functionality of a split bus panelboard or contactor system - but “soft” splits can be changed with a control module

Zone 1 Circuits 1–12 (Input 1 or 5)

•

Zone 3 Circuits 31–42 (Input 3 or 7)

3-wire switch + • • C • –

❏ Standard circuit breakers can be intermixed with remotely operated breakers Figure 1 - Soft-Split System

Low Voltage Matrix Switching System (simple-input based control) ❏ All POWERLINK AS systems can perform low voltage matrix switching ❏ Each system supports up to 16 low voltage inputs, expandable to 64 inputs ❏ Mapping of inputs to switch specific branch circuits is performed using a control module ❏ Any circuit can be logically connected (mapped) to any input

Table 1 Sample Control Map External Inputs 1 2 3 4 5

1 On

2 On

3

Control Circuits 4 5 On

10...18 On

19...42 On On On

Off

Off

On Off

Off

Off

Off

On Off

❏ Easy setup with graphic control module - reconfiguring to accommodate facility changes is easy and involves no rewiring ❏ After programming, the control module can be removed, and the POWERLINK AS systems will continue to switch circuits from input connections

Time Clock System using control module ❏ Same features as low voltage matrix switching ❏ Individual schedules for each circuit or zone

AS42C-T

❏ 7-day repeating schedules ❏ Special holiday schedules ❏ 365-day calendar ❏ Configure up to 256 events ❏ Sunrise/sunset astronomical clock eliminates the need for photocells ❏ Blink notice

AS42CM-T

❏ Daylight savings time ❏ Access codes for security ❏ Breaker status shown on graphic display 6

Standard control module (top) and graphic display control module

SQUARE D

9/98

Page 6

POWERLINK AS Systems Overview POWERLINK AS systems support a wide variety of network options to allow remote communications with the POWERLINK panel either via a workstation or from a third-party building automation system.

Network Topology and Compatibility Network options for the POWERLINK AS system are as follows: RS-485 • An optional RS-485 network communications port for integration into a power monitoring and control system. • Up to 32 panelboards can be connected on a multi-drop network directly to a personal computer via an RS-232/485 port. • To optimize system performance with multi-drop networks, the POWERLINK AS system can communicate over the Square D SY/NET network. This network supports communications speeds up to 500K Baud, distances up to 15,000 feet, and practically limitless device connections. LonWorks • Takes advantage of the latest industry standard technology to provide high-speed, peer-to-peer communications. • Allows the POWERLINK AS system to operate on the same network as other devices supporting the LonWorks protocol. • POWERLINK AS panelboards are fully LonMark compliant. • Adds capabilities to the POWERLINK AS system, such as the ability to create global zones or shared inputs. • Provides vast flexibility in configuring unique control solutions. Examples include the following:

Table 2 POWERLINK AS Systems, Components Components

–A time-of-day control module in one panel can control circuit breakers in many panels. –Third party I/O and software can interface directly with POWERLINK AS inputs and breakers.

POWERLINK System Types

Control Bus Strips

Power Interface Module

Class 2 Barrier Kit

Ethernet

Soft-Split System

X

X

X

LV Matrix Switching System

X

X

X

X*

Time Clock System

X

X

X

X

• Allows the POWERLINK AS system to communicate on new or existing networks • Provides high speed, high bandwidth communication

Powerful Software Solutions Square D offers a full line of simple to advanced, system-wide WINDOWS®-based software packages. POWERLINK AS application software automatically integrates real-time panelboard and system information into organized and usable formats.

Application Engineering Services The Square D Power Management Operation Engineering Services Group provides a complete range of commercial and industrial facility design and engineering services.

SQUARE D

9/98

Graphical Control Module with Clock

–An input switch in one panel can control circuit breakers in any panel on the network.

* Only one graphical control module is required to program all panelboards on the job site.

7

Page 7

POWERLINK AS Systems Overview Exploded View

Power Interface Module (standard and network versions)

The diagram to the right shows an Control Module exploded view of the (local display optional) POWERLINK AS system. The system Control Bus Strips components feature several advantages (furnished in pairs) over components of conventional systems:

Class 2 Barrier Kit NQOD/NEHB Panel (225 A max. interior)

• Modular design • Simple and quick installation • All components snap into place (plug and play) QO(B)-AS or EHB-AS Remotely Operated Circuit Breakers

• No wiring harnesses or pigtails

Figure 2 - POWERLINK AS System (Exploded View of Components)

Complete System The photo to the right shows a complete NQOD panelboard system. POWERLINK AS systems use standard NQOD and NEHB panelboards as foundations. All enclosures, interiors, deadfronts, and accessories are standard off-the-shelf items. The POWERLINK AS system components are discussed in detail in the following sections.

Class 2 Barrier Kit

Control Module with Local Display

Low Voltage External Control Device Input Compartment

Power Interface Module

1-, 2-, and 3-Pole Remote Control Circuit Breakers

Standard Circuit Breakers

Control Bus Strips (Furnished in Pairs) Main Lug Compartment (225 A Max.)

Figure 3 - POWERLINK AS Components in Assembled NQOD Panelboard

8

SQUARE D

9/98

Page 8

Electronic Components Remotely Operated Circuit Breakers Features • Overcurrent protection. POWERLINK AS circuit breakers provide the same overload and short circuit protection as standard QO(B) and EHB circuit breakers. • High interrupting. Series connected ratings up to 200,000 rms symmetrical amperes with integral or remote mounted main breakers. • Multi-pole switching. Single-, two-, and three-pole circuits can be switched. • Position indication. An integral on/off/trip status flag indicates the actual state of breaker contacts. • Up to 30 amperes. 15, 20, and 30 ampere ratings are available. • Rugged contacts. POWERLINK AS circuit breakers can handle the high loads found in buildings today. They are rated for full life with inductive loads (0.8 power factor). They are also rated for HACR (heating, air conditioning, and refrigeration) service, as well as HID (high intensity discharge) lighting loads. • Switch duty rated. 15 A and 20 A circuit breakers are SWD (switch duty) rated for use with 120 V fluorescent lighting loads. • Long life. At 200,000 electrical load operations, they last up to six times longer than other common power switching devices. • Manual override. Each circuit breaker has a mechanical override that has priority over remote operation. The circuit can be turned off or on in a crisis. • Plug and play control connector. Wiring mistakes are eliminated by modular connectors. There is no exposed wiring.

Principles of Operation The core of a POWERLINK AS circuit breaker is the highly effective Square D trip mechanism. A 24 Vdc motor, along with a drive train and linkage, provides remote operation capability. This motor is located in the left pole of the 2-pole circuit breaker and the center pole of the 3-pole circuit breaker. When the circuit breaker handle is in the on position, the motor and drive train can open and close the contacts. When the handle is in the off position or the circuit breakers is tripped, the contacts cannot be closed remotely.

EHB-AS Circuit Breakers

POWERLINK AS circuit breakers are an integral part of the POWERLINK lighting control system. These compact devices perform both overcurrent protection and remote switching functions. Circuit breakers feature rugged

The auto/manual switching mode selector on the front of the circuit breaker provides mechanical override capability. In manual mode, the motor drive train is disconnected from the contacts. The circuit breaker handle then operates the contacts like a conventional circuit breaker. A sensing device determines the presence or absence of voltage on the loadside terminal, and reports circuit breaker contact position back to the control system. Thus, a true-positive-closed-loop feedback of actual contact status is achieved.

contacts rated for 200,000 load operations and can be series rated for use with systems capable of providing 200,000 rms symmetrical fault current.

SQUARE D

9/98

9

Page 9

Electronic Components Remotely Operated Circuit Breakers

VISI-TRIP indicator Switching mode selector

General POWERLINK AS remotely operated, thermal-magnetic circuit breakers (hereafter referred to as POWERLINK AS circuit breakers) are designed to provide remote switching and overcurrent protection on ac voltage systems. They are available in 1-, 2-, and 3-pole construction. The 2- and 3-pole circuit breakers are common trip. An overcurrent condition on any given pole of the circuit breaker will cause all poles of the circuit breaker to open. POWERLINK AS circuit breakers are UL Listed and CSA Certified. They are manufactured and tested according to the following standards: • UL Standard 489 • NEMA Standard AB-1-1986 • Canadian Standards Association (CSA) Standard 22.5 (QO(B) only) • Federal Specification W-C-375B/GEN, Class 11a, 11b; 12a, 12b; and 13a, 13b • NOM 117 (pending final testing)

QO(B)-AS Circuit Breaker

Tripping System POWERLINK AS circuit breakers have a permanent trip unit that contains a factory preset thermal (overload) trip element and a magnetic (short circuit) trip element in each pole. The thermal trip element is true rms sensing and is calibrated to carry the continuous current rating of the breaker at 40°C (140°F) free air ambient temperature. In accordance with the National Electrical Code, POWERLINK AS circuit breakers are intended to be applied at up to 80 percent of their continuous current rating. Operating Mechanism POWERLINK AS circuit breakers have an over-center toggle mechanism that provides quick-make, quick-break operation and Square D’s unique VISI-TRIP® circuit breaker trip indicator. The operating mechanism is tripfree. This means the circuit breaker will trip even though the operating handle may be restricted to the ON position. Without any restrictions, the operating handle moves to a position between ON and OFF when the circuit breaker is tripped. An internal cross-bar provides common tripping of all poles on 2- and 3-pole POWERLINK AS circuit breakers. Circuit Breaker Status Indicator with VISI-TRIP POWERLINK AS circuit breakers are equipped with Square D’s unique VISI-TRIP circuit breaker trip indicator. The indicator window displays one of three colors to show circuit breaker contact status. Indicator Color

Circuit Breaker Contact Status

White

Circuit breaker contacts are closed

Green

Circuit breaker contacts are open

Red

VISI-TRIP indicator, circuit breaker is tripped

Load Terminations All load lugs are UL Listed to accept solid or stranded and copper or aluminum conductors. Lugs are suitable for use with wire rated for 75°C (sized according to the 1993 National Electrical Code 75°C temperature rating) QO(B)-AS circuit breakers are rated for 60°/75°C, and EHB-AS circuit breakers are rated for 75°C.

10

SQUARE D

9/98

Page 10

Electronic Components Remotely Operated Circuit Breakers Ratings for POWERLINK AS Circuit Breakers The following POWERLINK AS circuit breaker ratings must meet or exceed the parameters of the electrical system on which the breakers are used. Continuous Current Ratings POWERLINK AS circuit breakers have continuous current ampere ratings, as established by the 1993 NEC, Paragraph 240-6a, for 15A, 20A, and 30A devices. POWERLINK AS circuit breakers are to be applied in accordance with the NEC for 80 percent continuous current ratings in the intended enclosure. The continuous current ratings is indicated on the operating handle of each circuit breaker. Interrupting Ratings POWERLINK AS circuit breakers have interrupting ratings for each specific type: QO(B) or EHB, as shown in Table 3. The ampere interrupting rating of a circuit breaker is the highest current at rated voltage that the circuit breaker is intended to interrupt under standard test conditions and is expressed in rms symmetical amperes. The interrupting rating is stamped into each POWERLINK AS circuit breaker case for each voltage rating. POWERLINK AS circuit breakers have series connected ratings, like standard QO(B) and EHB breakers. The series connected ratings apply to either an integral main located in the same enclosure, or a remote main located in a separate enclosure. For more information on NQOD and NEHB panelboard series ratings, see page 28.

Table 3 UL Listed Interrupting Ratings for POWERLINK AS Circuit Breakers Table 1 Ratings for POWERLINK AS Circuit Breakers Catalog Number Prefix

Number of Poles

Continuous Voltage Current Rating

Continuous Maximum Current Voltage Rating Rating

Ampere Interrupting Rating

QO(B) QO(B)-AS QO(B) QO(B)-AS QO(B) QO(B)-AS

1 2 3

120/240Vac 120/240Vac 15A, 20A, 30A 240Vac

120/240Vac 15A, 20A, 30A 15A, 20A, 30A 120/240Vac 15A, 20A, 30A 240Vac

10,000A 10,000A 10,000A

EHB EHB-AS

1 1

120Vac 15A, 20A, 30A 277Vac

120Vac 15A, 20A, 30A 277Vac

65,000A 14,000A

EHB EHB-AS

2 2

120/240Vac 15A, 20A 480Y/277Vac

120/240Vac 15A, 20A 480Y/277Vac

65,000A 14,000A

EHB EHB-AS

3 3

240Vac 15A, 20A 480Y/277Vac

240Vac 15A, 20A 480Y/277Vac

65,000A 14,000A

Frequency Rating The rated frequency for POWERLINK AS circuit breakers is 50/60Hz. Applying POWERLINK AS circuit breakers at frequencies above or below the rated frequency may possibly damage the circuit breaker electronic components or system electronics. UL HACR Rating All POWERLINK AS circuit breakers are UL Listed for use with heating, air conditioning, and refrigeration equipment having motor group combinations and marked for use with HACR-type circuit breakers.

SQUARE D

9/98

11