Page 7
30598-376-01B1 Text Page 7 Saturday, July 26, 1997 10:12 AM
Bulletin No. 30598-376-01B1 July 1997
24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625
WARNING INCORRECT WIRING The base must be properly grounded before applying power. Equipment MUST be grounded using the screw provided. Do not use metallic conduit as a ground conductor. Failure to observe these instructions can result in death or serious injury.
Output Control Voltage (24 VDC)
DC (–) : Base Line Voltage (24 VDC) DC (+)
(+) (–)
3
1 2
9
7
5 4
6
11
12
10
8
15
13
17 16
14
21
19 18
20
23
25
22
24
27 26
29
33
31
28
30
32
37 39
35 34
36
38
40
AC or DC source
-SV +SV
NC
3
1 2
I3
11
4
6
8
10
12
N1
C0,1 NC
C2,3
3
I4
13
N1
VB- VB+
1
9
7
5
I2
I1
I0
I5
15
I6
17
I7
O8
21
19
O9
23
25
O10
O11
27
29
33
31
16
18
20
22
24
NC
NC C6,7
NC
C8,9 NC C10,11 NC C12,13 NC C14,15 NC
26
28
30
32
I2
I3
I4
I5
I6
I7
I8
O9
O10
O11
O12
O13 O14
5
7
9
11
13
15
17
19
21
23
25
27
29
31
6
GND
NC
NC
10
2
NC
1-
M
CO
Figure 2:
8
12
14
4
NC
3-
M
CO
35
C4,5
I1
4
NC
37 39
14
NC
2
O14 O15
O12 O13
16
18
6
NC
5-
M
CO
20
22
8
NC
7-
M
CO
24
26
10
NC
9-
M
CO
28
30
-2
NC
11
M
CO
33 32
34
36
O15 O16
34 4
-1
40
40
SY/MAX label (1-16)
NC
37 39
35
36
NC
38
6 NC GND
-1
13
M
CO
38
Telemecanique label (0-15)
15
M
CO
TBX DMS1625 Wiring Connections & Terminal Block Signal Assignments
© 1997 Schneider S.A. All Rights Reserved
7
Page 8
30598-376-01B1 Text Page 8 Saturday, July 26, 1997 10:12 AM
24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625
Bulletin No. 30598-376-01B1 July 1997
WARNING UNINTENTIONAL EQUIPMENT OPERATION Be sure to use the appropriate SY/MAX or Telemecanique terminal strip label when wiring inputs or outputs. Two terminal strip labels are packaged with the base unit. If you are using the base unit with a SY/MAX system, use the terminal strip label with I/O numbered from 1-16; if you have a Telemecanique system, use the terminal strip label with I/O numbered from 0-15. Failure to observe these instructions can result in death, serious injury, or equipment damage.
MOUNTING INSTRUCTIONS The base unit can be mounted horizontally or vertically as shown in Figure 3. ①
Mounting horizontally side-by-side
①
①
Mounting vertically side-by-side (terminal strips must be toward right as shown) ① Spacing: 1 in (25 mm)
Mounting horizontally Figure 3:
8
Base Unit Orientation Examples
© 1997 Schneider S.A. All Rights Reserved
Page 9
30598-376-01B1 Text Page 9 Saturday, July 26, 1997 10:12 AM
Bulletin No. 30598-376-01B1 July 1997
24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625
To mount the base unit on a 35-mm DIN rail: 1. Hook the base unit onto the rail as shown in Figure 4. 2. Press down and toward the DIN rail until the base unit is secure. (There are two spring clips in the top of the groove on the back of the unit.) To remove the base unit from a DIN rail: 1. Press down on the base unit. 2. Swing the unit outward and lift it off the rail at the same time as pressing down. NOTE: If the base unit is to be used in a high-vibration environment, mounting the unit on a panel rather than a DIN rail provides more stability. Use cable ties to secure the communication cable.
2
1
Figure 4: Mounting and Removing the Base Unit
INSTALLATION CONSIDERATIONS NOTE: The base unit is not compatible with the Type CRM270 interface module. • Base Voltage - The TBX DMS1625 base requires a 24 VDC operating voltage to be applied between terminals 3 and 1. • Grounding - The green ground wire must be connected to the ground screw beside the terminal block. • Jumper Wire - A #16 AWG wire must be installed between terminals 2 and 40. • Control Output Power - Output devices can be powered from a supply other than the one used to provide base voltage. Note that all power supplies must share the same common. The control output voltage supply needs to be connected between terminals 5 and 4. In addition, two jumpers must be installed, one from terminal 5 to 39, and one from terminal 4 to 38. • Commons - The TBX DMS1625 base unit has one common terminal for every two outputs. • Fusing - The base and control power lines must be externally fused by the user. • External Wiring - Each terminal accommodates up to two #16 AWG gauge wires. • Freeze State Control - With TBX Distributed I/O, the user may also have the DRIO set the outputs to a pre-defined state. By defining the output fallback states and enabling the Output Fallback function, the DRIO will now set the outputs to the fallback state when communication with the host PLC is lost. When communications are restored, the outputs will return to normal operation. Refer to the Type CRM275 and TSX manuals. © 1997 Schneider S.A. All Rights Reserved
9
Page 10
30598-376-01B1 Text Page 10 Saturday, July 26, 1997 10:12 AM
24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625
Bulletin No. 30598-376-01B1 July 1997
Load 1 O1
Neutral or Return
O1 Control Voltage Supply
Input Logic
COM 1-2
COM 1-2 Load 2
O2
O2
NC
NC
Simplified schematic for relay output
Figure 5:
(Optional: see “Installation Considerations)
Method of connecting loads
Simplified Schematic and Output Connections for DMS1625 Base Unit
REGISTER USAGE WITH THE SY/MAX CLASS 8030 TYPE CRM275 DRIO MODULE The TBX DMS1625 base unit supports the assignment of two registers for I/O, diagnostic and configuration registers. Additional information about base unit register usage is contained in the DRIO instruction bulletin (#30598-380). This base unit supports output fallback state control (Register 4, bits 5-6; Register 6). Refer to Chapter 4 of the DRIO instruction bulletin for more information about register assignments.
WARNING UNINTENTIONAL EQUIPMENT OPERATION Do not use reserved registers and bits in PLC programs. Erratic operation may result. Failure to observe this instruction can result in death, serious injury, or equipment damage.
10
© 1997 Schneider S.A. All Rights Reserved
Page 11
30598-376-01B1 Text Page 11 Saturday, July 26, 1997 10:12 AM
Bulletin No. 30598-376-01B1 July 1997
24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625
© 1997 Schneider S.A. All Rights Reserved
11
Page 12
30598-376-01B1 Text Page 12 Saturday, July 26, 1997 10:12 AM
Merlin Gerin
30598-376-01B1
Square D
July 1997
Telemecanique
Printed in USA
© 1997 Square D All Rights Reserved
DLC