For the Square D TBX-DMS1625 and Schneider TBX-DMS1625

Page 7

30598-376-01B1 Text Page 7 Saturday, July 26, 1997 10:12 AM

Bulletin No. 30598-376-01B1 July 1997

24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625

WARNING INCORRECT WIRING The base must be properly grounded before applying power. Equipment MUST be grounded using the screw provided. Do not use metallic conduit as a ground conductor. Failure to observe these instructions can result in death or serious injury.

Output Control Voltage (24 VDC)

DC (–) : Base Line Voltage (24 VDC) DC (+)

(+) (–)

3

1 2

9

7

5 4

6

11

12

10

8

15

13

17 16

14

21

19 18

20

23

25

22

24

27 26

29

33

31

28

30

32

37 39

35 34

36

38

40

AC or DC source

-SV +SV

NC

3

1 2

I3

11

4

6

8

10

12

N1

C0,1 NC

C2,3

3

I4

13

N1

VB- VB+

1

9

7

5

I2

I1

I0

I5

15

I6

17

I7

O8

21

19

O9

23

25

O10

O11

27

29

33

31

16

18

20

22

24

NC

NC C6,7

NC

C8,9 NC C10,11 NC C12,13 NC C14,15 NC

26

28

30

32

I2

I3

I4

I5

I6

I7

I8

O9

O10

O11

O12

O13 O14

5

7

9

11

13

15

17

19

21

23

25

27

29

31

6

GND

NC

NC

10

2

NC

1-

M

CO

Figure 2:

8

12

14

4

NC

3-

M

CO

35

C4,5

I1

4

NC

37 39

14

NC

2

O14 O15

O12 O13

16

18

6

NC

5-

M

CO

20

22

8

NC

7-

M

CO

24

26

10

NC

9-

M

CO

28

30

-2

NC

11

M

CO

33 32

34

36

O15 O16

34 4

-1

40

40

SY/MAX label (1-16)

NC

37 39

35

36

NC

38

6 NC GND

-1

13

M

CO

38

Telemecanique label (0-15)

15

M

CO

TBX DMS1625 Wiring Connections & Terminal Block Signal Assignments

© 1997 Schneider S.A. All Rights Reserved

7

Page 8

30598-376-01B1 Text Page 8 Saturday, July 26, 1997 10:12 AM

24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625

Bulletin No. 30598-376-01B1 July 1997

WARNING UNINTENTIONAL EQUIPMENT OPERATION Be sure to use the appropriate SY/MAX or Telemecanique terminal strip label when wiring inputs or outputs. Two terminal strip labels are packaged with the base unit. If you are using the base unit with a SY/MAX system, use the terminal strip label with I/O numbered from 1-16; if you have a Telemecanique system, use the terminal strip label with I/O numbered from 0-15. Failure to observe these instructions can result in death, serious injury, or equipment damage.

MOUNTING INSTRUCTIONS The base unit can be mounted horizontally or vertically as shown in Figure 3. ①

Mounting horizontally side-by-side

①

①

Mounting vertically side-by-side (terminal strips must be toward right as shown) ① Spacing: 1 in (25 mm)

Mounting horizontally Figure 3:

8

Base Unit Orientation Examples

© 1997 Schneider S.A. All Rights Reserved

Page 9

30598-376-01B1 Text Page 9 Saturday, July 26, 1997 10:12 AM

Bulletin No. 30598-376-01B1 July 1997

24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625

To mount the base unit on a 35-mm DIN rail: 1. Hook the base unit onto the rail as shown in Figure 4. 2. Press down and toward the DIN rail until the base unit is secure. (There are two spring clips in the top of the groove on the back of the unit.) To remove the base unit from a DIN rail: 1. Press down on the base unit. 2. Swing the unit outward and lift it off the rail at the same time as pressing down. NOTE: If the base unit is to be used in a high-vibration environment, mounting the unit on a panel rather than a DIN rail provides more stability. Use cable ties to secure the communication cable.

2

1

Figure 4: Mounting and Removing the Base Unit

INSTALLATION CONSIDERATIONS NOTE: The base unit is not compatible with the Type CRM270 interface module. • Base Voltage - The TBX DMS1625 base requires a 24 VDC operating voltage to be applied between terminals 3 and 1. • Grounding - The green ground wire must be connected to the ground screw beside the terminal block. • Jumper Wire - A #16 AWG wire must be installed between terminals 2 and 40. • Control Output Power - Output devices can be powered from a supply other than the one used to provide base voltage. Note that all power supplies must share the same common. The control output voltage supply needs to be connected between terminals 5 and 4. In addition, two jumpers must be installed, one from terminal 5 to 39, and one from terminal 4 to 38. • Commons - The TBX DMS1625 base unit has one common terminal for every two outputs. • Fusing - The base and control power lines must be externally fused by the user. • External Wiring - Each terminal accommodates up to two #16 AWG gauge wires. • Freeze State Control - With TBX Distributed I/O, the user may also have the DRIO set the outputs to a pre-defined state. By defining the output fallback states and enabling the Output Fallback function, the DRIO will now set the outputs to the fallback state when communication with the host PLC is lost. When communications are restored, the outputs will return to normal operation. Refer to the Type CRM275 and TSX manuals. © 1997 Schneider S.A. All Rights Reserved

9

Page 10

30598-376-01B1 Text Page 10 Saturday, July 26, 1997 10:12 AM

24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625

Bulletin No. 30598-376-01B1 July 1997

Load 1 O1

Neutral or Return

O1 Control Voltage Supply

Input Logic

COM 1-2

COM 1-2 Load 2

O2

O2

NC

NC

Simplified schematic for relay output

Figure 5:

(Optional: see “Installation Considerations)

Method of connecting loads

Simplified Schematic and Output Connections for DMS1625 Base Unit

REGISTER USAGE WITH THE SY/MAX CLASS 8030 TYPE CRM275 DRIO MODULE The TBX DMS1625 base unit supports the assignment of two registers for I/O, diagnostic and configuration registers. Additional information about base unit register usage is contained in the DRIO instruction bulletin (#30598-380). This base unit supports output fallback state control (Register 4, bits 5-6; Register 6). Refer to Chapter 4 of the DRIO instruction bulletin for more information about register assignments.

WARNING UNINTENTIONAL EQUIPMENT OPERATION Do not use reserved registers and bits in PLC programs. Erratic operation may result. Failure to observe this instruction can result in death, serious injury, or equipment damage.

10

© 1997 Schneider S.A. All Rights Reserved

Page 11

30598-376-01B1 Text Page 11 Saturday, July 26, 1997 10:12 AM

Bulletin No. 30598-376-01B1 July 1997

24 VDC 8 Input/8 Output Relay Base Unit TBX DMS1625