Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 1 of 2

TSX 17 micro-PLCs: TSX 17-10/20 micro-PLCs, pages 1 to 6

Pages 1 to 6 of 12

The original document is the PDF (194 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Telemecanique TSX172-3444, Schneider TSX172-3444 and Square D TSX172-3444

Page 1

TSX 17 micro-PLCs TSX 17-10/20 micro-PLCs Characteristics : Pages 41101/7 to 41101/9 References, dimensions : Pages 41101/10 and 41101/11 Connections : Pages 41101/12 to 41101/15

TSX 17-10 selection, description

TSX 17-10 and TSX 17-20 micro-PLCs comprise a compact 20 to 40 I/O base, compact modular extensions to increase the number of I/O to 160, and intelligent analogue, timer and communication modules. These micro-PLCs are suitable for both simple, small scale control systems and more complex systems which use analogue processing and communication.

Selection Discrete I/O Maximum number Discrete I/O Basic number

88

102

100

120

20

34

20

40

No. of extensions (1)

2

2

2

2

Power supply c110/240 V c110/240 V a 24 V a 24 V

Inputs a 24 V isolated a 24 V isolated a 24 V a 24 V

Outputs

Relay

Relay

Transistor 1 and 2 A

Transistor 1 and 2 A

Maximum memory size FIPIO bus/ FIPWAY network

8 Kb

8 Kb

8 Kb

8 Kb

No

No

No

No

UNI-TELWAY link

No

No

No

No

TSX 17-10 micro-PLCs (1) No intelligent modules.

TSX 171 2028E

TSX 171 3428E

TSX 171 2002E

TSX 171 4002E

Description TSX 17-10 micro-PLCs are programmed in PL7-1 Boolean language and have a single task software structure. Each TSX 17-10 micro-PLC base consists of a processor with an 8 K byte internal RAM memory.

The front panel comprises : 1

2 5

4

3

4

S

6

S

1 A c110/240 V, 50/60 Hz or a 24 V power supply 2 An RS 485 port for connection to the programming terminal 3 A slot for EEPROM or EPROM cartridge 4 20, 34 or 40 discrete I/O with screw terminals on removable terminal blocks (a 24 V inputs, relay or 1 and 2 A non-protected transistor outputs) 5 A a 24 V sensor power supply (with the basic c110/ 240 V - 50/60 Hz PLC) 6 A PLC and I/O status display panel 7 An I/O bus extension connector

7

Separate parts S A backup battery for program and data memory 3 An 8 K byte EPROM or EEPROM memory cartridge for program backup

41101/2

Te

Backup system

Backup time for application program

Backup time for data

Internal memory

1 hour

1 hour

Battery

2 years

2 years

EEPROM/EPROM cartridge EEPROM/EPROM cartridge and battery

Permanent

1 hour

Permanent

2 years

Page 2

TSX 17 micro-PLCs TSX 17-10/20 micro-PLCs Characteristics : Pages 41101/7 to 41101/9 References, dimensions : Pages 41101/10 and 41101/11 Connections : Pages 41101/12 to 41101/15

TSX 17-20 selection, description

Selection PL7-1 discrete I/O Maximum number PL7-2 discrete I/O Maximum number Discrete I/O Basic number (1) PL7-1 extensions Maximum number

88

88

102

102

100

120

122

122

136

136

140

160

20

20

34

34

20

40

2

2

2

2

2

2

PL7-2 extensions (2) of which intelligent modules

3

3

3

3

3

3

3

3

3

3

3

3

Power supply c110/240 V c110/240 V c110/240 V c110/240 V a 24 V a 24 V

Isolated inputs a 24 V c 110 V a 24 V c 110 V a 24 V a 24 V

Outputs

Relay

Relay

Relay

Relay

Transistor 0.35 A

Transistor 0.35 A

Maximum memory size FIPIO bus/ FIPWAY network (3)

24 Kb

24 Kb

24 Kb

24 Kb

24 Kb

24 Kb

Yes

Yes

Yes

Yes

Yes

Yes

UNI-TELWAY link (3) Yes Yes Yes Yes Yes TSX 17-20 TSX 172 TSX 172 TSX 172 TSX 172 TSX 172 micro-PLCs 2028E 2044E 3428E 3444E 2012E (1) Not including 2 event-triggered inputs and 1 fast counter. (2) Intelligent modules included, except for UNI-TELWAY bus slave adaptor or FIPIO/FIPWAY module. (3) Only with PL7-2 language.

Yes TSX 172 4012E

Description The TSX 17-20 micro-PLC is programmed in PL7-1 Boolean language (operations on bits). PL7-2 programs can be processed by adding the TSX P17 20 Ei as standard language cartridge (on bits and on 16-bit words). There are two types of language cartridge (with or without real-time clock). Each micro-PLC base consists of a processor with a 24 K byte internal RAM memory. The front panel comprises : 9

2

1

6

4

3

5

8

S

5

7

10

1 A c110/240 V, 50/60 Hz or a 24 V power supply 2 An RS 485 port for connection to programming terminal, UNI-TELWAY multidrop bus or communication peripheral 3 A slot for an EEPROM or EPROM memory cartridge 4 A slot for a PL7-2 language cartridge 5 20, 34 or 40 discrete I/O with screw terminals on removable terminal blocks (a 24 V or c 110 V isolated inputs, relay or 0.35 A protected transistor outputs) 6 A a 24 V sensor power supply (with the basic c110/ 240 V, 50/60 Hz PLC) 7 A PLC and I/O status display panel 8 Two a 24 V event-triggered inputs 9 A 2 kHz, c 5/24 V fast counter 10 An I/O bus extension connector

Separate parts S A backup battery for program and data memory 3 An 8 or 24 K byte EPROM or EEPROM memory cartridge for program backup Backup system

Backup time for application program

Backup time for data

Internal memory

1 hour

1 hour

Battery

2 years

2 years

EEPROM/EPROM cartridge EEPROM/EPROM cartridge and battery

Permanent

1 hour

Permanent

2 years

Te

41101/3

Page 3

TSX 17 micro-PLCs TSX 17-10/20 micro-PLCs Characteristics : Pages 41101/7 to 41101/9 References, dimensions : Pages 41101/10 and 41101/11 Connections : Pages 41101/12 to 41101/15

Functions

Special I/O 4

2

3

1 Input for RUN/STOP control Input I0,00 on the TSX 17-10/20 PLC base can be used for the PLC RUN/STOP control, if it is configured for this. 2 Alarm output Output O0,00 on the TSX 17-10/20 PLC base can be used as an alarm output for external safety circuits, if it is configured for this. 3 Event-triggered inputs The event-triggered inputs available on the TSX 17-20 PLC can be used with either PL7-1 or PL7-2 language. They consist of 2 a 24 V dedicated inputs, I0,24 and I0,25, with short filter times (< 1 ms). The use of these inputs permits the immediate processing of events without waiting for the updating of the I/O associated with the Master task (total response time < 2 ms). A change of state of either of these 2 inputs initiates the execution of the fast task cycle.

1

4 Fast counter/timer The TSX 17-20 PLC has a fast counting function which can be used with either PL7-1 or PL7-2 language. A 10000 point counter receives the pulses from the counting input (at a maximum frequency of 2 kHz). When the preset value is reached, the counter activates the fast task, thus permitting the control of the actions within a short, guaranteed response time. Two inputs are associated with this function : - a counting input which can receive pulses from a sensor (incremental encoder, proximity sensor, etc) - a reset input which resets the counter to zero These a 24 V or a 5 V inputs are available on a 9-way connector on the front panel. They are connected to an incremental encoder or a sensor by a TSX CCB 020 cable or a TSX CAC 04 solder connector.

Real-time clock Real-time clock parameters Nature : second, minute, hour, day, month and year Type : current value and last PLC stop (STOP or power break) Drift : < 4 seconds per day Backup : on a power break, by lithium battery TSX 17 ACC 1 installed in the PLC base

When an application controlled by a TSX 17-20 PLC requires time-related data, the PLC must be equipped with PL7-2 language cartridges : TSX P17 20FB/FD1. In addition to PL7-2 software, these also include a real-time clock which is protected in the event of a power failure (backup time : 1 hour without battery, 2 years with battery). This real-time clock continually provides the following functions : i Timed and dated programming i Event logging i Elapsed time measurement The real-time clock continually provides the following time parameters : second, minute, hour, day, month and year.

Numerical display

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

MD

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

41101/4

Te

The TSX 17 ACC 2 numerical module can be fitted instead of the I/O display for TSX 17-20 PLCs running PL7-2 language. The I/O are displayed on a 4-digit display (height 3.5 mm). This display corresponds to the contents of system word SW16 which can be programmed in BCD by the user program.

Page 4

TSX 17 micro-PLCs TSX 17-10/20 micro-PLCs Characteristics : Pages 41101/7 to 41101/9 References, dimensions : Pages 41101/10 and 41101/11 Connections : Pages 41101/12 to 41101/15

Descriptions

Description of discrete I/O extensions PLC bases and extensions have different types of discrete I/O : i a 24 V isolated or non-isolated inputs, and c 110 V isolated inputs i 0.35 A protected or 1 and 2 A non protected relay, triac, or transistor outputs Exchanges between the processor and the I/O interface are systematically performed on each PLC scan. Operating safety Fault bits and system bits for controlling the I/O are available to the user. Processing these bits in the user program permits downgraded operation and thus contributes to the analysis of first level application maintenance. 1

2

TSX DMF discrete extension blocks comprise : 1 A c 110/240 V, 50/60 Hz or a 24 V power supply 2 34 or 40 discrete I/O with screw terminals on removable terminal blocks ( a 24 V or c 110 V isolated inputs, relay or transistor outputs) 3 A a 24 V sensor power supply (with c110/240 V, 50/60 Hz unit) 4 An I/O status display panel 5 I/O bus extension connecting cable

3

2

4

5

1

2

TSX DEF and TSX DSF discrete extension modules comprise : 1 Eight inputs or six outputs connected to screw terminals (a 24 V or c110 V inputs, relay, triac or 0.35 A protected transistor outputs) 2 An I/O status display panel 3 An I/O bus extension connector

1 3

Description of analogue timer module This module provides, on each of its 4 channels, the latch delay for a TSX 17-10/20 bit variable. Each channel can be adjusted using an internal or external potentiometer in accordance with 4 time ranges. 1 2 3

1

Potentiometer Range 1 0.1 to Internal 1s External 0.1 to (1 M ) 6s

Range 2 0.15 to 1.5 s 0.15 to 9s

Range 3 1 to 10 s 1 to 60 s

Range 4 10 to 100 s 10 to 600 s

The TSX DTF 400 analogue timer module comprises : 1 Two terminals for connecting external potentiometers or jumpers (supplied) if internal potentiometers are used 2 Four internal potentiometers 3 Four status indicator lamps : - blinking : time delay in progress - steady : time delay elapsed and a fault indicator lamp

Te

41101/5

Page 5

TSX 17 micro-PLCs TSX 17-10/20 micro-PLCs Characteristics : pages 41101/7 to 41101/9 References, dimensions : pages 41101/10 and 41101/11 Connections : pages 41101/12 to 41101/15

Compatibility and layout

Compatibility Configurations must conform to the table below : i TSX 17-10 and TSX 17-20 micro-PLCs used with PL7-1 language can be extended by 2 discrete extension blocks or modules (it is possible to mix different blocks and modules). i TSX 17-20 micro-PLCs used with PL7-2 language can be extended by 3 discrete extension or analogue communication extension blocks or modules and 1 UNI-TELWAY adaptor module (it is possible to mix different blocks and modules). The table below has been defined using a discrete I/O load rate of 60 %. PLC base

Language Max no. of extensions (1)

TSX 171 2028 TSX 171 3428

PL7-1

2

TSX 171 2002

PL7-1

2

TSX 171 4002

PL7-1

2

TSX 172 2028 TSX 172 2044

PL7-1

2

PL7-2

3

PL7-1

2

PL7-2

3

TSX 172 2012

TSX 172 3428 TSX 172 3444 TSX 17B 1428 (5)

PL7-1

2

PL7-2

3

TSX 172 4012

PL7-1

2

PL7-2

3

Combination possible Combination not possible

Discrete I/O extension blocks TSX DMF 242A 342A 344A 400

Extension modules

401

TSX DTF 400 TSX DEF TSX DSF 804/812 604/612 635

UNIFIPIO/ TELWAY FIPWAY module module

TSX SCG 11i1 TSX AEG TSX ASG TSX 17 411i 200i ACC5

(2)

(4)

(2)

TSX FPG 10

(3)

(3) (6)

(3)

(3) (6)

(3)

(3) (6) (7)

(3) (3) (6) (7) (1) Excluding TSX 17 ACC5 UNI-TELWAY adaptor module and TSX FPG 10 FIPIO bus/FIPWAY network module. (2) The a 24 V sensor power supply provided by the PLC base or an extension block can only supply one extension module. An external a 24 V power supply must be provided when several extension modules are used. (3) For a language cartridge version < 5.1, one TSX 17 ACC 5 or TSX FPG 10 module is permitted per TSX 17-20 configuration is authorised. (4) The maximum number of TSX DSF 635 modules is limited to 2. (5) The TSX 17B 1428 micro-PLC is used with PL7-2 language. (6) The TSX FPG 10 FIPWAY network module must always be the last extension module. (7) With a maximum of a 34 or 40 I/O block or a TSX SCG 11i1 module and two 6 or 8 I/O modules.

Layout Starting from the PLC base (address 0), discrete or analogue modules and blocks can be added in any order. The last extension block or module must be fitted with a TSX 17 ACC10 end of line adaptor. A block with address n is connected to a block or module with address n-1 using a 0.32, 0.90 or 1.6 m cable depending on location. The total length of the cable should not exceed 2.20 m).

Discrete, analogue and communication extension modules

A block with address n is connected to a block or module with address n-1 using a cable which is incorporated in the module. Module with address n is therefore always located to the right of the block or module whose address is n-1.

TSX 17-20 micro-PLC layout examples (in PL7-2 language)

> 70

Extension blocks

3 1

2

1

0

3

1 2 41101/6

Te

1 4

> 40

> 40

0

TSX CBB 003 connecting cable, length 0.32 m. TSX CBB 009 connecting cable, length 0.90 m.

2

2

3

2

4

3 Cable built into extension module. 4 TSX 17 ACC 10 end of line adaptor.

Page 6

TSX 17 micro-PLCs TSX 17-10/20 micro-PLCs Composition : Pages 41101/2 and 41101/3 References, dimensions : Pages 41101/10 and 41101/11 Connections : Pages 41101/12 to 41101/15

Characteristics

Environment Temperature Altitude Degree of protection

Operating + 5…+ 55 °C, storage - 25…+ 70 °C 0…2000 m IP 20 conforming to IEC 664 and NF C 20040

Power supply characteristics c 110...240 V TSX 171ii/172ii TSX DMF 242A/3iiA a 24 V TSX 171ii TSX DMF 400 a 24 V TSX 172ii TSX DMF 401 c 110…240 V c 90…264 V 50/60 Hz 47…63 Hz 42 VA 31 VA a 24 V/0.25 A 1500 V rms, 50 Hz Yes a 24 V a 19.2…30 V (1) – – 21 W 5W – None Yes a 24 V a 19.2…30 V (1) – – 28 W 3W – 1500 V rms, 50 Hz Yes

PLC bases Extension blocks and modules

Isolated inputs a 24 V TSX 171ii/172ii TSX DMF 242A/342A/401

Non-isolated inputs a 24 V Inputs c 110 V TSX 171ii TSX 172ii TSX DMF 400 TSX DMF 344A/DEF 804

TSX DEF 812

Type of inputs Nominal input values

Isolated a 24 V 7 mA a 19.2…30 V (1)

Non-isolated a 24 V 7 mA a 19.2…30 V (1)

Isolated c 110 V (47…63 Hz) 15 mA c 88…132 V

Isolated a 24 V 15 mA a 19.2…30 V (1)

Positive On PLC To + 24 V of sensor power supply (3) 11 V 2.5 mA for U = 11 V 5V 1.4mA 3.2…3.7 k 4.5…12 ms 4.5…12 ms 0.17 W 500 30 k

Positive On PLC

– On PLC

Positive On PLC

To + 24 V of power supply 11 V 2.5mA for U = 11 V 5V 1.4mA 3.2…3.7 k 4.5…12 ms 4.5…12 ms 0.17 W 500 30 k

–

To + 24 V of power supply 11 V 6 mA 5V 3 mA 1.5…1.7 k 6…18 ms 4…13 ms 0.35 W 500 30 k

10 M at a 500 V Opto-coupler Type 1 Yes

None – Type 1 Yes

PLC bases Extension blocks and modules Supply voltage Frequency

Nominal Limit Nominal Limit Power PLC required Extension Protected sensor power supply Primary/earth isolation Conforms to standard IEC 65A

Input characteristics (2)

Voltage Current Sensor power supply

Logic Display of each input Sensors commoned Input limit values

At state 1 Voltage Current At state 0 Voltage Current Input impedance Response From state 0 to 1 times From state 1 to 0 Power dissipation per point at 1 External Line resistance line Leakage resistance Isolation

Between inputs and bus Type Conforms to standard IEC 1131 Compatible with Telemecanique 2 and 3-wire sensors

74 V 6 mA for U = 74 V 20 V 4mA 5.8…9.5 k 5…33 ms 11…50 ms 0.2 W 1k 30 k Leakage capacity 100 nF 1500 V rms, 50/60 Hz Opto-coupler Type 2 2 wire c 110 V

Isolated inputs a 24 V

10 M at a 500 V Opto-coupler Type 2 Yes

Characteristics of event-triggered and fast counter inputs (2) Inputs

Event-triggered

Fast counter

Voltage a 24 V a 24 V a5V Current 15 mA 15 mA 38 mA At state 1 Voltage 11 V 11 V 2V Current 6 mA for U = 11 V 6 mA for U = 11 V 6 mA for U = 2 V At state 0 Voltage 5V 5V 1V Current 3 mA 3 mA 3 mA Immunity From state 0 to 1 0.15…1 ms Maximum frequency permitted From state 1 to 0 0.3…1 ms 2 kHz Isolation Between inputs and bus 10 M at a 500 V – – Type Opto-coupler – – Conforms to standard IEC 65A Class 2 Class 2 – Compatible with Telemecanique Yes Yes – 2 and 3-wire sensors (1) Ripple included. (2) Input characteristics are given for a load rate of 60 % (number of inputs simultaneously at state 1 in relation to total number of inputs). (3) Except TSX DMF 401 : sensors commoned to + 24 V of power supply. Nominal values Input limit values

Te

41101/7