Page 11
TECHTERM TERMINALS
CHAPTER 1
OVERVIEW
About this Manual Intended for authorized developers with prior knowledge of hand held PC application development, this manual describes the advanced features, operations and interface capabilities of Two Technologies’ TechTerm terminals. It is not for use by end-users. Unless otherwise stated, the operational characteristics described herein correspond to factory default configurations and settings as shipped from Two Technologies with a standard 45-key keypad. Because TechTerm terminals are highly customizable products with several optional configurations and special keypad layouts, this manual only describes standard features and operation. For custom configurations and special options, consult the appropriate supplemental manual or addendum. It is beyond the scope of this manual to provide operating system tutorials or information about commercial or customized TechTerm application programs and connected equipment. This information should be available in the manuals that accompany those products. Wherever used herein, the term “TechTerm” applies to all models (except as noted). NOTICE The information contained in this manual applies only to TechTerm terminals manufactured after May 2001 (Serial Number HH184408 and above). Because newer models contain additional functions not found on previous models, use of these functions on older terminal may cause unexpected results.
Symbols and Conventions Unless otherwise noted, this manual uses the following format conventions to distinguish elements of text: •
New terms used in this manual initially appear in Italics, for example: host.
•
Names of keys as shown on a keypad appear in bold type, for example: CTRL.
•
Names of parameter values appear in uppercase letters, for example: ENABLE.
•
Esc represents the ASCII escape character in Escape commands, for example: Esc [4n.
•
A lowercase “h” appearing after a number denotes a hexadecimal value, for example: 1Bh.
Document 15776(1.0.0.0)
1
Page 12
About Two Technologies Two Technologies has been producing rugged hand held and panel mount terminals and computers for over fifteen years. By implementing state of the art design and manufacturing techniques, we revolutionized hand held terminals and computers inside and out. Today, Two Technologies offers over a dozen cost-effective solutions serving virtually every market.
About the TechTerm Specifically designed for industrial applications, the TechTerm is a rugged and fully functional ASCII terminal with selectable operating parameters and fifteen menuprogrammable function keys. Parameters and function key definitions are stored in nonvolatile memory. Commands issued by the host device can directly control the TechTerm’s cursor movement, cursor style and signal tones from the built-in speaker.
TechTerm Features Two Technologies offers the TechTerm with the following features. You can find additional information regarding specifications in Appendix A.
Power The TechTerm is available as a line-powered or battery-powered unit. Line-powered units use a 7.5-12 VDC linear regulator. A 5 VDC (±5%) transformer and optional 9.5-28 VDC switching regulator are also available, depending on current draw. Battery-powered TechTerms come equipped with a push-button power switch, low-battery indicator and a rechargeable Nickel Metal Hydride (NiMH) battery. Operating time on a full charge is up to 40 hours, depending on use. Battery-powered TechTerms can also operate on six AA alkaline batteries
Display TechTerms come with a standard 80-character monochrome liquid crystal display that features the standard U. S. ASCII character set as dark characters on a light background. A supertwist nematic display is available for applications that require a greater viewing angle. For applications where ambient light is insufficient, backlit supertwist and LED Backlight supertwist displays are available for line-powered units. Other display options for line-powered units include a Vacuum Fluorescent Display (VFD) and an extended temperature VFD.
2
Overview
Page 13
TECHTERM TECHNICAL REFERENCE MANUAL
Keypad Securely framed and clamped into place, the keypad surface provides excellent splash resistance and prevents curling or peeling of the keypad overlay. Keypad layouts include 45, 30, and 20 keys available with standard or custom graphics and 32 and 15 keys available with custom graphics. Keypads can be made from your choice of elastomeric or membrane material.
Switches and Indicators You can program up to fifteen function keys (keyboard dependent) with single characters and save in non-volatile memory. Battery-powered TechTerms have an On/Off switch and a low battery indicator.
Interface Options Interface options for the TechTerm include RS-232, RS-422 or CMOS/TTL protocols. Communication (up to 9600 bps) with a host device is through a modular 6-pin connector.
Durability Like all Two Technologies' products, the TechTerm is remarkably rugged. The case consists of Cycolac ABS, one of the most durable, chemical-resistant materials available on the market today.
Document 15776(1.0.0.0)
3
Page 14
Page 15
TECHTERM TERMINALS
CHAPTER 2
OPERATION
Controls and Indicators Figure 2-1 describes the possible components and indicators found on the front of a TechTerm as shown in Table 2-1. Figure 2-1: TechTerm Controls and Indicators
1
BAT LOW
2
3 + A F / K
( B ! G & L
*
@
P Q = # R S ^ $ T U ' % V . W " X E SC Y B AC KS P Z S
4
PAC
E
) C _ H : M
< D [ I ; N
> E ] J ? O
CTR L ENT ER SHIF T
5 Table 2-1: TechTerm Controls and Indicators Item
Control/Feature
Description
1
Display
4 Rows of 20 (5 x 7 pixel) characters
2
Low Battery Indicator
Battery-powered unit only
3
Power Switch
Battery-powered unit only
4
Keypad
45-key keypad (standard)
5
Modular Interface Connector
Supplies communication and power
Document 15776(1.0.0.0)
5
Page 16
Cable and Power Connections Internal Communication Devices The following table lists the internal interface devices used in the TechTerm. Table 2-2: Interface Devices Interface
Manufacturer
Device
RS-232
Linear Technology
LT1281
RS-422
Linear Technology
LTC490
Signal and Pin Assignments Modular Interface Connector Figure 2-2 depicts the standard six-pin modular interface connector found on the TechTerm. Table 2-3 describes its signal and pin assignments. Warning: Use the six-pin modular receptacle for compatible serial devices only. Despite its physical similarity to modular telephone connectors, it is not compatible with telephone lines or signals. Connecting the terminal to a telephone line will damage it and void the warranty.
Figure 2-2: Modular Interface Connector
123456
Viewed facing
Table 2-3: Modular Interface Connector Signal and Pin Assignments Pin
6
RS-232/CMOS/TTL
RS-422
1
+ Supply to terminal
+ Supply to terminal
2
Handshake-In to terminal
+ Data-In to terminal
3
Handshake-Out from terminal
+ Data-Out from terminal
4
Data-In to terminal
- Data-In to terminal
5
Data-Out from terminal
- Data-Out from terminal
6
Common
Common
Operation
Page 17
TECHTERM TECHNICAL REFERENCE MANUAL
Standard Accessory Cables Standard modular cables (1210-7 and 1210-15) that mate with the terminal’s modular interface connector and Two Technologies’ PCAT wired adapter are available as optional accessories. These cables will reverse the signal output from the terminal (see illustration below). Non-reversing modular cables (1210-7-NR and 1210-15-NR) are also available. Figure 2-3: 1210 Series Modular Cable Red Black White
Green Yellow Blue
Blue Yellow Green White) Red) Black) Green) Yellow) Blue)
White Black Red Blue) Yellow) Green) Black) Red) White)
PCAT Wired Adapter The PCAT modular connector enables connection to a host device as well as supplying a connection for a power supply. Figure 2-4: PCAT Modular Connector Power Socket Pin 6
Pin 1
Pin 9 Pin 6
6 Pin Modular Jack Common 1 Data Out 2 Data In 3 Handshake Out 4 Handshake In 5 +5V Out 6
Note:
Blue Yellow Green Red Black White
Pin 5 Pin 1
Female DE 9 Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9
(Black) Handshake In (Yellow) Data Out (Green) Data In (Black) Handshake In (Blue) Common (Red) Handshake Out (Jumper) (Jumper) RI
Pin descriptions assume connection through a Two Technologies’ 1210 series modular cable to the terminal’s modular connector.
Document 15776(1.0.0.0)
7
Page 18
Connecting the Terminal To connect the terminal to a host device using Two Technologies parts: 1.
Plug one end of a 1210 modular cable into the modular connector on the bottom of the terminal. Plug the other end into the PCAT adaptor.
2.
Plug the PCAT adapter into the host device.
Power Line-Powered Units To supply power to a line-powered TechTerm: 1.
Plug one end of a 1210 modular cable into the modular connector on the bottom of the terminal. Plug the other end into the PCAT adaptor. Figure 2-5: Cable Connections Bottom of Unit Power Supply/ Battery Charger
Modular Cable
PCAT Adapter
8
2.
Using a Two Technologies’ power supply (such as a Two Technologies 1226-1 linear power supply for units with a -2 power supply configuration), plug the power supply connector into the PCAT adapter and then plug the power supply into a 120 VAC 60 Hz power outlet.
3.
The terminal should turn on and a blinking cursor should appear on the display. If the terminal does not turn on, refer to the Troubleshooting section of this manual for help.
Operation
Page 19
TECHTERM TECHNICAL REFERENCE MANUAL
Battery-Powered Units Battery-powered TechTerms come equipped with a rechargeable Nickel Metal Hydride (NiMH) battery that has exceptional charge life without the “charge memory” characteristic of conventional nickel cadmium batteries. Partially discharged batteries or extended periods with the charger left connected will not adversely affect battery life or performance. Operating time on a full charge is up to 40 hours, depending on use. The time required for a full charge depends on the initial state of the battery. With the terminal off, this time should not exceed eight hours. Battery-powered TechTerms can also operate on six AA alkaline batteries. Battery-powered TechTerms also have a low battery indicator, which indicates that there is approximately one hour of operating power remaining. A built-in power saver will turn off battery-powered TechTerms after ten minutes of inactivity. Any key press or character received by the TechTerm will reset the power-saver timer. To turn on battery-powered units, press the On/Off switch. The terminal should turn on and a blinking cursor should appear on the display. If the terminal does not turn on, refer to the Troubleshooting section of this manual for help.
Charging the Unit Because the internal battery charger senses several conditions, including temperature, you should charge the unit away from any known or potential heat sources. Units exposed to temperatures in excess of 90 degrees Fahrenheit during the charge cycle may experience incomplete charging and reduced operating time per charge. To recharge the Nickel Metal Hydride (NiMH) battery pack, plug the Two Technologies’ power supply/battery charger (Part # 13799) into the PCAT adapter and then plug the power supply/battery charger into a 120 VAC 60 Hz power outlet.
Changing Batteries To change batteries: 1.
With the unit face down, pull the battery cover retaining clip up from its recessed slot and turn the clip in a counter clockwise motion.
2.
Lift the cover up and remove the batteries. If the unit contains a battery pack, use the tab on the battery pack to lift up and then out.
Document 15776(1.0.0.0)
9
Page 20
3.
Insert the new batteries or battery pack into the unit using the orientation shown in Figure 2-6. Figure 2-6: Battery Orientation
Retaining Clip
Battery Compartment
TOP
CAUTION: R ISK OF EXPL O SION IF BAT TER Y I S R EPL AC ED BY AN IN C O RR EC T TYPE. D ISPO SE O F U SED BAT T ER IES AC CO R D I N G TO TH E I N ST R U C TI ON S.
NiMH Battery Pack
PLEASE RECYCLE
BOTTOM
Tab
4.
10
Close the battery cover and turn the battery cover retaining clip clockwise to lock the cover.
Operation