Page 21
TECHTERM TECHNICAL REFERENCE MANUAL
Keypad Operation The standard 30 position and 45 position keypads consist of uppercase letters, digits 0 through 9, punctuation marks, symbols, function keys and keys for Escape (ESC), Space (SPACE), Backspace (BACKSP/BKSP), Control (CTRL), Shift (SHIFT) and Enter (ENTER). You can program the SHIFT key to operate in normal or locked mode. In the locked mode, pressing a modifier key will toggle its respective state. Transmission of control characters will cancel the control state. If both the Shift and Control states are active, lowercase alphabetic characters will replace corresponding uppercase alphabetic characters. For Function keys (F1, F2, etc.), you can re-assign default characters with characters from the key output definition menu (see Appendix C). The standard 20 position keypads consist of the digits 0 through 9, functions keys and keys for Yes (YES), No (NO), Backspace (BKSP), Space (SPACE) and Enter (ENTER). Figure 2-7: Standard Keypads
F1 F2 F4 F3
1 2 3 4 5 6 7 8 9 0 45 Position Keypad
30 Position Keypad
20 Position Keypad
Display Operation The TechTerm screen displays the standard U.S. ASCII 96 character set. Characters appear at the display at the current cursor location.
Cursor Position Typically, the cursor moves from left to right as the terminal displays characters (unless altered by Escape commands). The cursor is host command programmable as a block or underscore, blinking or non-blinking.
Document 15776(1.0.0.0)
11
Page 22
Whenever a character appears in the last position of the top three rows, the cursor will move to the leftmost position on the next row. Whenever a character appears in the last position on the bottom row, the terminal will temporarily hide the cursor. After scrolling the screen up one row, the TechTerm will display the next character in the first position on a new bottom row followed by the cursor.
Operating Modes TechTerms have several operating modes. The default mode is Terminal mode. It allows the terminal to display characters, respond to commands sent by a connecting device, and send characters to the connecting device as keys are pressed. Other modes, described later in this manual, enable you to set operating parameters and program function key definitions.
Host Control The design of TechTerms allows a connecting device (or “host”) to control its functions through the transmission of a string of special characters. Referred to as “Escape commands” (because each character string begins with the ASCII escape character), these character strings enable the host to move the cursor, sound an alert, program the function keys and set any of the operating parameters.
12
Operation
Page 23
TECHTERM TERMINALS
CHAPTER 3
MANUAL CONFIGURATION
Introduction A comprehensive set of user-settable operating parameters and programmable function keys makes the TechTerm suitable for diverse applications. Each settable parameter and programmable function key has a default value. These values are stored in the terminal's permanent memory. This chapter describes each operating parameter in detail, as well as how to set the parameters and load the default values. Chapter 4 covers programmable function keys.
Parameter Menu Settings The following section describes the parameters that you can program in a TechTerm. A summary (Table 3-1) appears at the end of the section.
Baud Rate This parameter sets the number of bits per second transmitted. The data rate can be set to: 300, 600, 1200, 2400, 4800 or 9600 baud. The default value is 9600.
Data Bits This parameter sets the number of data bits transmitted per character, either seven (7) or eight (8). The default value is eight (8).
Parity This parameter enables/disables the host’s ability to perform error checking on incoming characters and ensure accuracy. Allowable settings are EVEN, ODD, MARK, SPACE and IGNORE. The default value is EVEN. When set to EVEN, ODD, MARK or SPACE, the terminal will perform the corresponding check on incoming data. When set to IGNORE will still add a parity check bit to each character, but the value of that bit is indeterminate. Note:
Should the host require a communication setting of 8 data bits with no parity, select 7 data bits and SPACE parity.
Document 15776(1.0.0.0)
13
Page 24
Display PE When using a parity of EVEN, ODD, MARK or SPACE, you can enable this parameter to display a special character (Figure 3-1) when a parity error occurs. With this option disabled, the character displays as received. The default value is ENABLED. Figure 3-1: Parity Error Symbol
Repeat This parameter determines the repeat keypad character rate while the key remains pressed. The allowable values are SLOW (10 characters per second), FAST (18 characters per second) and DISABLED. The default value is FAST. When set to DISABLED, key repeat is inoperative. In all cases, there is a short delay between the initial character and the start of the repeat.
Echo This parameter enables/disables the TechTerm’s ability to display (echo) keypad entries on the screen. When set to DISABLED (the default value), only characters received by the terminal will display.
Handshake This parameter enables/disables use of the two handshake lines (DTR-DSR or RTS-CTS) in models equipped with a RS-232 or TTL/CMOS interface. The Handshake parameter has a default value of ENABLED. When enabled, the terminal will only send characters to the host when it detects the Handshake-In line. If the terminal cannot process the incoming characters, it will drop its Handshake-Out line to the host. Any characters sent in this state will be lost. When disabled, the terminal will assert the Handshake-Out line and ignore the HandshakeIn line.
Self-Test This setting determines if the TechTerm will perform a confidence test at boot-up. The test displays the U.S. ASCII Character Set and checks the internal RAM and ROM. The TechTerm will beep when the test is completed. If an error occurs, the TechTerm will display an error message. The Self-Test parameter has a default value of DISABLED.
14
Manual Configuration
Page 25
TECHTERM TECHNICAL REFERENCE MANUAL
Power Saver The Power Saver parameter is available on battery-powered units only. When enabled, the terminal will turn itself off after ten minutes of inactivity (no key press or characters receive from host). The Power Saver parameter has a default value of ENABLED
Parameter Menu Summary The following table lists the allowable settings and default values available through the Parameter menu. Table 3-1: Parameter Menu Summary Parameter
Options (Default In Bold)
BAUD
300, 600, 1200, 2400, 4800, 9600
DATA BITS
7, 8
PARITY
EVEN, ODD, MARK, SPACE, IGNORE
DISPLAY PE
ENABLED, DISABLED
REPEAT
SLOW, FAST, DISABLED
ECHO
ENABLED, DISABLED
HANDSHAKE
ENABLED, DISABLED
SELF TEST
ENABLED, DISABLED
POWER SAVER 1
ENABLED, DISABLED
1. Only appears on battery-powered units.
Document 15776(1.0.0.0)
15
Page 26
Changing Parameter Settings The following procedure describes how to change parameter settings using a 45 or 30-key TechTerm, other keypad configurations may work differently. To change the parameters settings: 1.
For 45 or 30-key terminals, simultaneously hold CTRL and SHIFT, and press F1. For 20-key terminals, simultaneously hold BKSP and ENTER, and press F1.
Note:
You can also access the Parameter menu, by removing power, simultaneously holding CTRL, SHIFT and F3 (for 20-key terminals, use BKSP, ENTER and F3), and reapplying power.
The Parameter menu appears with the first parameter on the top line.
2.
To change the value of the current parameter, press F1.
3.
To view the next parameter, press F2.
4.
To view the previous parameter, press F3.
5.
To save any changes and exit the menu on 45 or 30-key terminals, press F5. To exit the menu without saving any changes, press F4. To save any changes and exit the menu on 20-key terminals, press F4. If you make any changes, the TechTerm will display the following screen:
16
Manual Configuration
Page 27
TECHTERM TECHNICAL REFERENCE MANUAL
Loading Factory Default Settings The following procedure describes how to load the factory default settings using a 45 or 30key TechTerm, other keypad configurations may work differently. To load the factory default settings: 1.
Remove power or turn off the TechTerm.
2.
For 45 or 30-key terminals, simultaneously hold CTRL, SHIFT and F1, and reapply power. For 20-key terminals, simultaneously hold BKSP, ENTER and F1, and reapply power.
3.
After the terminal sounds an alert and displays the "LOAD DEFAULTS?" message, release the keys.
4.
For 45 or 30-key terminals, press F1 to reload the default values. Press F5 to leave the parameters unchanged. For 20-key terminals, press F1 to reload the default values. Press F4 to leave the parameters unchanged.
Restricting Access The following procedure describes how to prevent access to the Parameter menu and disable function key programming using a 45 or 30-key TechTerm, other keypad configurations may work differently. To restrict access to the Parameter menu and disable function key programming: 1.
Remove power or turn off the TechTerm.
2.
For 45 or 30-key terminals, simultaneously hold CTRL, SHIFT and F5, and reapply power. For 20-key terminals, simultaneously hold BKSP, ENTER and F5, and reapply power. In either case, the terminal will display the following message:
To re-enable access to the Parameter menu and function key programming, simply repeat the procedure above.
Document 15776(1.0.0.0)
17
Page 28
Page 29
TECHTERM TERMINALS
CHAPTER 4
KEY PROGRAMMING
Introduction You can program between 10 and 15 function keys with single ASCII characters, including non-printing characters depending on the keypad type (Figure 2-7). All programmable function key settings are stored in the TechTerm’s nonvolatile memory. Notes: To display the results of key programming on your terminal, you must enable ECHO. The number of programmable function keys may vary with custom keypad configurations.
Table 4-1: Function Key Values Keypad 45 Key
30 Key
20 Key
Document 15776(1.0.0.0)
Key
Value
+ SHIFT
+ CTRL
F1
11h
61h
66h
F2
12h
62h
67h
F3
13h
63h
68h
F4
14h
64h
69h
F5
15h
65h
6Ah
F1
41h
11h
01h
F2
42h
12h
02h
F3
43h
13h
03h
F4
44h
14h
04h
F5
45h
15h
05h
F1
41h
N/A
N/A
F2
42h
N/A
N/A
F3
43h
N/A
N/A
F4
44h
N/A
N/A
19
Page 30
Defining Function Keys The following procedure describes how to define a function key using a 45 or 30-key TechTerm, other keypad configurations may work differently. To define a function key: 1.
On 30-key and 45-key terminals, simultaneously hold CTRL, SHIFT and F2. On 20-key terminals, simultaneously hold BKSP, ENTER and F2. The screen will display:
2.
Select a key to program, by pressing that key (for example, F1). The screen will then show hex code for that key (H11).
3.
Press F1 to change the current value. You can also press F3 to return to the previous screen or press F5 to exit (on 20-key terminals, press F4). When changing the current value, the screen will display:
4.
Enter the new hex code. If needed, press F3 to change your entry.
5.
To save you changes, press F5 (on 20-key terminals, press F4). To quit without saving, press F1.When saving your changes, the screen will display:
Warning! Do not remove power from the terminal while the above message appears on the screen or you will corrupt all stored data. Should you remove power during this time, you will have load default values.
Notes:
You can disable function key programming by simultaneously pressing CTRL, SHIFT and F5. Refer to the Restricting Access procedure for additional information. To display the results of key programming on your terminal, you must enable ECHO.
20
Key Programming