Page 31

TECHTERM TERMINALS

CHAPTER 5

HOST COMMANDS

Introduction The TechTerm will respond to certain command strings issue from a host device to control some of its functionality. These commands can start with either an Escape character or a Control character. For example, sending an Esc E will clear the display and move the cursor to the home position), while sending a Ctrl K will move the cursor down one row. Note:

Do not use spaces between characters in Control or Escape commands. Any spacing shown for Escape commands in this chapter is for clarity only unless otherwise noted.

Escape Commands This section describes the Escape commands that a host devices can issue to control the TechTerm’s functionality. A summary of Escape commands appears at the end of this section. Note:

You cannot buffer sound commands. To produce properly spaced chain sounds, the host must delay a short time between issuing sound commands.

Cursor Up Syntax

Esc A

Notes

Moves the cursor up one row, but not beyond the start or end of a line, nor will it scroll the display

Cursor Down Syntax

Esc B

Notes

Moves the cursor down one row, but not beyond the start or end of a line, nor will it scroll the display

Document 15776(1.0.0.0)

21

Page 32

Cursor Right Syntax

Esc C

Notes

Moves the cursor one position to the right, but not beyond the start or end of a line, nor will it scroll the display

Cursor Left Syntax

Esc D

Notes

Move the cursor one position to the left, but not move the start or end of a line, nor will it scroll the display

Cursor Home & Clear Display Syntax

Esc E

Notes

Includes the character at the cursor location

Enable Underscore Cursor Syntax

Esc F

Disable Underscore Cursor Syntax

Esc G

Cursor Home Syntax

Esc H

Erase Display Syntax

Esc I

Notes

Includes the character at the cursor location, but does not alter the cursor position

Erase Cursor to End of Display Syntax

Esc J

Notes

Includes the character at the cursor location and does not alter the cursor position

Erase Cursor to End of Line

22

Syntax

Esc K

Notes

Includes the character at the cursor location and does not alter the cursor position

Host Commands

Page 33

TECHTERM TECHNICAL REFERENCE MANUAL

Long Bell Syntax

Esc L

Erase Entire Line Syntax

Esc M

Notes

Includes the character at the cursor location and does not alter the cursor position

Click Syntax

Esc P

Alert Syntax

Esc Q

Enable Blinking Cursor Syntax

Esc R

Disable Blinking Cursor Syntax

Esc S

Short Bell Syntax

Esc T

Enable Key Click Syntax

Esc U

Disable Key Click Syntax

Document 15776(1.0.0.0)

Esc V

23

Page 34

Cursor Position Syntax Notes

Examples

Esc Y Pr Pc

Moves the cursor to a specified location where Pr is the ASCII character equivalent of the row numbers and Pc is the ASCII character equivalent of the column numbers shown below. Row (Pr)

ASCII

Column (Pc)

ASCII

Column (Pc)

ASCII

1

SP

1

SP

11

*

2

!

2

!

12

+

3

“

3

“

13

,

4

#

4

#

14

-

5

$

15

.

6

%

16

/

7

&

17

0

8

‘

18

1

9

(

19

2

10

)

20

3

Esc Y !) will send the cursor to Row 2, Column 10 Esc Y #0 will send the cursor to Row 4, Column 17 Esc Y !+ will send the cursor to Row 2, Column 12

Return Terminal Identifier String Syntax

Esc Z

Notes

This commands sends the following identifier string to the host: TT1BCCCCNN Where B indicates a battery unit (if applicable), CCCC is the four-byte hexadecimal checksum of the terminal’s program memory and NN is the keypad type (30 = 30-key keypad or blank = 45-key keypad). When using this command to identify the terminal type, do not include the checksum as it may change.

24

Host Commands

Page 35

TECHTERM TECHNICAL REFERENCE MANUAL

Escape Command Summary The following table is a summary of the available host commands. Table 5-1: Host Command Summary Command Cursor Up

Code/Syntax Esc A

Cursor Down

Esc B

Cursor Right

Esc C

Cursor Left

Esc D

Cursor Home & Clear Display

Esc E

Enable Underscore Cursor

Esc F

Disable Underscore Cursor

Esc G

Cursor Home

Esc H

Erase Display

Esc I

Erase Cursor to End of Display

Esc J

Erase Cursor to End of Line

Esc K

Long Bell

Esc L

Erase Entire Line

Esc M

Click

Esc P

Alert

Esc Q

Enable Blinking Cursor

Esc R

Disable Blinking Cursor

Esc S

Short Bell

Esc T

Enable Key Click

Esc U

Disable Key Click

Esc V

Cursor Position

Esc Y Pr Pc

Return Terminal Identifier String

Esc Z

Control Code Commands The host can control some of TechTerm’s functionality by sending it commands that start with the Control character. For example, sending a Ctrl G will sound the bell on the TechTerm. Table 5-2: Control Codes Command

Code

Send ENQ

Ctrl E

Sounds Bell

Ctrl G

Back Space Cursor

Ctrl H

Line Feed

Ctrl J

Cursor Down

Ctrl K

Cursor Left to Column 1

Ctrl M

Delete Character at Cursor

DEL

Document 15776(1.0.0.0)

25

Page 36

This page is a scan with no text; see it in the PDF.

Page 37

TECHTERM TERMINALS

CHAPTER 6

TROUBLESHOOTING

Cursor does not appear on display Possible Cause:

No power to terminal (host supplied)

Solution:

Verify proper voltage to terminal

Possible Cause:

No power to terminal (adapter supplied)

Solution:

Verify wall plug is functional and wiring of adapter (if wired as kit)

Possible Cause:

Reversed polarity, improper wiring or wrong cable type

Solution:

Check cable and connector wiring

Possible Cause:

Cursor not enabled

Solution:

Re-enable the cursor by sending an Esc [4t (ANSI mode) or Esc F (Private mode) or by changing the CURSOR parameter setting

Terminal resets or locks-up Possible Cause:

Low voltage output

Solution:

Verify proper voltage to terminal

Possible Cause:

Cable resistance too high or wire gauge too small

Solution:

Cable should be 26 AWG or larger

Possible Cause:

Handshaking between host and terminal

Solution:

When using handshaking, verify that the wiring between the host and terminal is correct, that you have the HANDSHAKE parameter enabled and that the handshake line from the host is asserted When not using handshaking, make sure you have the HANDSHAKE parameter disabled

Terminal does not perform self-test Possible Cause:

Self-test parameter disabled

Solution:

Change SELF TEST parameter to ENABLE

Document 15776(1.0.0.0)

27

Page 38

Terminal not receiving or displaying correct characters Possible Cause:

Parity settings incorrect

Solution:

Change PARITY parameter to correct setting

Possible Cause:

Data bits incorrect

Solution:

Change DATA BITS parameter to correct setting

Possible Cause:

Incorrect BAUD rate

Solution:

Change BAUD parameter to correct setting

Possible Cause:

Handshaking between host and terminal

Solution:

When using handshaking, verify that the wiring between the host and terminal is correct, that you have the HANDSHAKE parameter enabled and that the handshake line from the host is asserted When not using handshaking, make sure you have the HANDSHAKE parameter disabled

Possible Cause:

Reversed polarity, improper wiring or wrong cable type

Solution:

Check cable and connector wiring

Terminal displays PE character Possible Cause:

Incorrect parity setting

Solution:

Change the PARITY setting on the terminal to match the host or vice versa

Possible Cause:

Handshaking between host and terminal

Solution:

When using handshaking, verify that the wiring between the host and terminal is correct, that you have the HANDSHAKE parameter enabled and that the handshake line from the host is asserted When not using handshaking, make sure you have the HANDSHAKE parameter disabled

Terminal generates continuous sound while pressing key Possible Cause:

Handshaking between host and terminal

Solution:

When using handshaking, verify that the wiring between the host and terminal is correct, that you have the HANDSHAKE parameter enabled and that the handshake line from the host is asserted When not using handshaking, make sure you have the HANDSHAKE parameter disabled

Terminal displays double characters

28

Possible Cause:

Echo turned on

Solution:

Disable ECHO parameter

Troubleshooting

Page 39

TECHTERM TECHNICAL REFERENCE MANUAL

Cannot access parameter mode or function key programming Possible Cause:

Menu lock-out enabled

Solution:

Remove power, simultaneously hold CTRL, SHIFT and F5, and reapply power

Possible Cause:

Handshaking between host and terminal

Solution:

When using handshaking, verify that the wiring between the host and terminal is correct, that you have the HANDSHAKE parameter enabled and that the handshake line from the host is asserted When not using handshaking, make sure you have the HANDSHAKE parameter disabled

Terminal losing characters Possible Cause:

Handshaking between host and terminal

Solution:

When using handshaking, verify that the wiring between the host and terminal is correct, that you have the HANDSHAKE parameter enabled and that the handshake line from the host is asserted When not using handshaking, make sure you have the HANDSHAKE parameter disabled

Function keys not sending correct values Possible Cause:

Key accidentally reprogrammed

Solution:

Reprogram function key

Possible Cause:

EEPROM corrupted by line disturbance

Solution:

Restore factory defaults and then reprogram parameters and function keys

Possible Cause:

Terminal reset to factory defaults after repair

Solution:

Reprogram function keys