UniTek manual for the Classic C2.1 230/180-12f thyristor motor controller, a compact single-board unit for speed control of DC motors with tachometer regulation, armature voltage regulation with IxR compensation, or torque control. It covers safety advice, technical data, dimensions, electrical installation and connection plans, the circuit diagram, the trimming potentiometers and switches, command and actual value setup, controller adjustment, EMC advice and the guarantee.

Its parts

  1. Basic information
  2. Mechanical installation
  3. Electrical installation
  4. Adjustment
  5. Guarantee

From the manual · read page by page

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

This is the manual, edition 1104-2, for the Unitek Classic C2.1 230/180-12 f galvanic isolated thyristor motor controller, a single-board drive for speed control of direct-current motors. It gives the technical data, power and motor connection, trimmer and switch adjustment of speed, current and controller gain, and EMC wiring advice.

What it is
Thyristor control unit for speed control of direct-current motors, 1 quadrant mode p. 4
Power
Up to 2160 Watt p. 4
Regulation modes
Tachometer regulation, armature voltage regulation with I*R compensation, torque control p. 4
Isolation
Galvanic isolation between control and power section; fully isolated power semiconductor p. 4
Supply
230V~ mains, direct with mains choke or through an isolation transformer p. 7
High voltage
AC 230V~, DC 320V= on the device p. 3
Chokes
Mains choke with filter Type K78-16F; armature (smoothing) choke Type EI135A-12 p. 16
Tachometer input
DC tachometer, or AC or three-phase tachometer with rectification; maximum -180V= p. 11
Internal fuses
2.5Aff and 16Aff p. 5
Protection
IP00 p. 3
Construction
Compact single circuit board with plug-in screw terminals and field rectifier p. 4
Default switches
Tachometer regulation: S1-1, S1-4, S2-1, S2-3, S3-1 to S3-4 ON, all other switches OFF p. 10
IxR compensation
Potentiometer IxR P1, range 0 to 40% p. 12
Status LEDs
LED D1 glows when enabled; brightness of LED D2 shows the drive's current demand p. 14

What this manual walks you through

  • Connecting mains, isolation transformer, armature and field p. 7
  • Setting the trimming potentiometers and DIP switches p. 10
  • Coarse and fine speed adjustment for tachometer or armature voltage regulation p. 11, 12
  • Setting the current limit and the PI settings of current and speed controllers p. 13
  • First start-up, speed, current and gain adjustment p. 14
  • Adjusting the controller without measuring instruments p. 15
  • EMC mounting and wiring for EU regulation 89/336/EWG p. 16

Good to know

  • Installation work only when disconnected from all power lines, and adjustment only by qualified personnel. p. 3
  • Machines need supervisory and safety equipment independent of the device. p. 3
  • The command value input is connected to the mains. p. 11
  • Next to its note that armature voltage regulation has a high-resistive mains connection, the manual says clamp 5 must not be earthed. p. 4
  • When balancing speed, set nmin first and nmax second. p. 12

Questions this manual answers

How much power can the Unitek C2 230/180-12 drive?

The manual gives power up to 2160 Watt for the Classic C2.1 230/180-12f. p. 4

Which chokes go with the Unitek C2 230/180-12?

The EMC advice names mains choke with filter Type K78-16F and armature choke Type EI135A-12. p. 16

How do I set the current limit?

With an amperemeter in the armature circuit, turn trimmer I max P6 clockwise to increase the current limit. p. 13

Why does the motor go straight to top speed?

If the motor accelerates straight up to top speed, the actual value connection at clamps 6-7 must be swapped. p. 14

The whole text · 2 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9
  2. Pages 10 to 1810-18

The file

Revision and size

RevisionEdition 1104-2
PublisherUniTek Industrie Elektronik GmbH
Pages18
PDF1.8 MB
TextText from the PDF itself; pages 6, 8 and 9 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 18

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 18
Page 2
Page 2of 18
Page 3
Page 3of 18