Manual · Unitek
Manual Thyristor-Motor-Controller Classic C2.1 230/180-12 f, galvanic isolated
Manual18 pagesPDF 1.8 MB
Manual for the UniTek Classic C2.1 230/180-12 thyristor motor controller for speed control of direct-current motors.
Covers · 1 model
The models it covers
Summary
What is in it
UniTek manual for the Classic C2.1 230/180-12f thyristor motor controller, a compact single-board unit for speed control of DC motors with tachometer regulation, armature voltage regulation with IxR compensation, or torque control. It covers safety advice, technical data, dimensions, electrical installation and connection plans, the circuit diagram, the trimming potentiometers and switches, command and actual value setup, controller adjustment, EMC advice and the guarantee.
Its parts
- Basic information
- Mechanical installation
- Electrical installation
- Adjustment
- Guarantee
From the manual · read page by page
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
This is the manual, edition 1104-2, for the Unitek Classic C2.1 230/180-12 f galvanic isolated thyristor motor controller, a single-board drive for speed control of direct-current motors. It gives the technical data, power and motor connection, trimmer and switch adjustment of speed, current and controller gain, and EMC wiring advice.
- What it is
- Thyristor control unit for speed control of direct-current motors, 1 quadrant mode p. 4
- Power
- Up to 2160 Watt p. 4
- Regulation modes
- Tachometer regulation, armature voltage regulation with I*R compensation, torque control p. 4
- Isolation
- Galvanic isolation between control and power section; fully isolated power semiconductor p. 4
- Supply
- 230V~ mains, direct with mains choke or through an isolation transformer p. 7
- High voltage
- AC 230V~, DC 320V= on the device p. 3
- Chokes
- Mains choke with filter Type K78-16F; armature (smoothing) choke Type EI135A-12 p. 16
- Tachometer input
- DC tachometer, or AC or three-phase tachometer with rectification; maximum -180V= p. 11
- Internal fuses
- 2.5Aff and 16Aff p. 5
- Protection
- IP00 p. 3
- Construction
- Compact single circuit board with plug-in screw terminals and field rectifier p. 4
- Default switches
- Tachometer regulation: S1-1, S1-4, S2-1, S2-3, S3-1 to S3-4 ON, all other switches OFF p. 10
- IxR compensation
- Potentiometer IxR P1, range 0 to 40% p. 12
- Status LEDs
- LED D1 glows when enabled; brightness of LED D2 shows the drive's current demand p. 14
What this manual walks you through
- Connecting mains, isolation transformer, armature and field p. 7
- Setting the trimming potentiometers and DIP switches p. 10
- Coarse and fine speed adjustment for tachometer or armature voltage regulation p. 11, 12
- Setting the current limit and the PI settings of current and speed controllers p. 13
- First start-up, speed, current and gain adjustment p. 14
- Adjusting the controller without measuring instruments p. 15
- EMC mounting and wiring for EU regulation 89/336/EWG p. 16
Good to know
- Installation work only when disconnected from all power lines, and adjustment only by qualified personnel. p. 3
- Machines need supervisory and safety equipment independent of the device. p. 3
- The command value input is connected to the mains. p. 11
- Next to its note that armature voltage regulation has a high-resistive mains connection, the manual says clamp 5 must not be earthed. p. 4
- When balancing speed, set nmin first and nmax second. p. 12
Questions this manual answers
How much power can the Unitek C2 230/180-12 drive?
The manual gives power up to 2160 Watt for the Classic C2.1 230/180-12f. p. 4
Which chokes go with the Unitek C2 230/180-12?
The EMC advice names mains choke with filter Type K78-16F and armature choke Type EI135A-12. p. 16
How do I set the current limit?
With an amperemeter in the armature circuit, turn trimmer I max P6 clockwise to increase the current limit. p. 13
Why does the motor go straight to top speed?
If the motor accelerates straight up to top speed, the actual value connection at clamps 6-7 must be swapped. p. 14
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file