For the Unitek C2 230/180-12

Page 10

Classic C2.1 - 230/180 -12f Trimming potentiometers Nr. P1

Abbreviation IxR

P2 P5 P4 P6 P7 nmax INT nmin Imax XP

Switches

Function speed compensation when using armature voltage regulation fine adjustment maximum speed integration time limit minimum speed current limit amplification

Nr.

Contact

S1 S1

1, 2 3, 4

S2 S2

1, 2 3, 4

S3

1-4

Function Current contoller integral- term proTermal- amplification Sspeed controller integral- term proTermal- amplification Tachometer tachometer coarse balance

S4

2 tachometer smoothing

Default setup Tachometer regulation

Switch on the position ON:

S1-1, S1-4, S2-1, S2-3, S3-1 to S3-4

Armature voltage regulation 180V= Switch on theposition ON :

Torque regulation

Switch on the position ON :

S1-1, S1-4, S2-1,S2-3, S3-1 to S3-4 S1-1, S1-4, S4-1

All other Switches on position OFF !

10

Range 0...40 % 80...120 % 0.08 ... 5 sec. -0.2 ... +2V 0 … 100 % 3…

Page 11

4 Adjustment Command value

Command value voltage Command value potentiometer input resistance input voltage resistance >1k 50k. 0 ... max. +12V=

Using a current source external load resistance

12V / 20mA = 0.6k

(2.5 … 10k)

Caution: command value input is connected to the mains Integrator Setup trimmer INT P5 turn clockwise to increase time - range 0.08 up to 5 sec.

Actual Value Tachometer regulation - DC-tachometer - a.c.- or three-phase current tachometer with rectification - tachometer voltage maximum -180V= - IxR potentiometer P1 anti-clockwise stop !

Caorse adjustment of the tachometer (switches settings) tacho voltage 90 … 180 V 60 … 140 V 20 … 60 V 11 … 20 V

S3-1 ON ON OFF OFF

Speed fine adjustment Setup trimmer nmin P4 trimmer nmax P2 turn clockwise to increase speed

S3-2 ON OFF ON OFF

S3-3 ON ON OFF OFF

S3-4 ON OFF OFF OFF range -0.2 ... 2V com. value 50% of coarse adjustment

Caution: balance first nmin secondly nmax balance.

C2 .1-230/180-12f

11

Page 12

Classic C2.1 - 230/180 -12f Armature voltage regulation Adjustment Switch S3

Armature voltage 90 ...180V 60 ... 140V 20 ... 60V 11 ... 20V

S3-1 ON ON OFF OFF

S3-2 ON OFF ON OFF

S3-3 ON ON OFF OFF

S3-4 ON OFF ON OFF

Speed- fine adjustment Setup potentiometer nmin P4 potentiometer nmax P2 turn clockwise to increase speed

Range - 0.2 ... 2V command value 50 of the coarse adjustment

Caution: balance nmin first, n max second IxR Compensation

- voltage drop caused by the internal resistance of the motor - compensated by current proportional speed slope Setup potentiometer IxR P1 turn clockwise to increase compensation

Range 0 ...40%

- set speed to 10% - increase load up to 100% - increase compensation - load speed >>> idling speed

Torque regulation - speed regulator amplification set to 1. Switch S4-1 closed. - switch S2 all contacts in OFF - jumper S9 closed. XP without function - switch S1-1, S1-4 closed

12

Page 13

4 Adjustment Current Current limit Setup trimmer I max P6 turn clockwise to increase current limit measure current

PI-settings of the current regulator Setup with swith S1 P-values amplification 150K 0.68 60 K 0.27 35 K 0.16 26 K 0.12

Range 0 ... 100% >>> amperemeter in armature circuit

S1-3 OFF OFF

ON

ON

S1-4 OFF ON OFF ON

I-values S1-1 0.22 F OFF 0.8 F ON 1.2 F OFF 1.8 F ON Integral - time constant = I-value x P-Value x 4

S1-2 OFF OFF ON ON

Speed controller PI-setting of the speed regulator Setup with DIP switch S2 P-values amplification 330 k 3.3 165 k 1.65 110 k

I-values 0.22 F 0.69 F 1.20 F 1.69 F Integral - time constant =

S4 OFF OFF ON

S1 OFF ON OFF ON I-value x P-Value x 4

Setting Amplification trimmer XP P7 turn clockwise to decrease amplification

C2 .1-230/180-12f

S3 OFF ON ON

S2 OFF OFF ON ON

Range 3 ..

13

Page 14

Classic C2.1 - 230/180 -12f Device not enabled, command value zero.

Switch on the mains the motor must be at standstill without a torque.

Close enable switch

LED D1 “Freigabe(=Enable)” must glow. Slowly turn up command value potentiometer. The motor must accelerate according to the command value voltage. (if the motor accelerates straight up to top speed, the actual value connection clamp 6-7 must be swapped.)

Speed adjustment actual value-coarse adjustment Using 1V command value with Poti nmax (P2) >>> with Poti nmin (P4) >>> 10V command value with Poti nmax (P2)

switch S3 (see Page 11) setup 10% speed. setup minimum speed. trim 100% speed.

Current adjustment amperemeter in armature circuit turn Poti Imax to anti-clockwise stop. block motor. (disconnect field) with Poti Imax (P6) >>> trim motor current.

Amplification speed regulation default setup : P-Amplification I-term

S2-3= ON, S2-4= OFF S2-1= ON, S2-2= OFF large centrifugal mass

>>> frictional load

>>>

S2-2 = closed S2-3 = open S2-2 and S2-4 = closed S2-1 and S2-2 = open

Fine adjustment turn anti-clockwiswe turn clockwise

>>> >>>

Potentiometer XP (P7) LEDD2 (RVU) flickers LEDD2 shines steady

The brightness of LED D2 shows the current demand of the drive.

14

Page 15

4 Adjustment Adjustment without measuring instruments Connect motor, command value XP switch S2-3 switch S2-4

= 10% = 50% = ON = OFF

Enable controller turn Potentiometer Xp anti-clockwise until the drive swings. LED D1 (RVU) flickers. If there is no oscillation - switch S2-3 in position OFF - adjust oscillation with Potentiometer XP - LED D1 (RVU) flickers - turn Potentiometer Xp clockwise until the oscillation dies down - LEDD1 (RVU) shines steady - turn X P-Poti 2 steps clockwise Adjust S2-1 and S2-2 so, that the drive runs smoothly after about two oscillation when there was a command value jump off 50%. Response of the drive: Amplification too low long-period oscillations 1... 0.1Hz long overshoots

C2 .1-230/180-12f

Amplification too high short-period oscillations 30 ... 200Hz vibrates during acceleration

15

Page 16

Classic C2.1 - 230/180 -12f Advice to EU-Regulation 89/336/EWG the standards EN61000-2 and EN61000-4 will be observed under the following conditions: Tachometer regulation Device, mains choke or transformer and armature choke fixed on a 500x500x2 mounting board. Motor interference-suppressed with collector-capacitor. Mounting board and motor frame connected to earth with 10mm² wires. Clamp 5 connected to earth with a 2.5mm² wire Power supply with mains choke: Mains choke with filter Type K78-16F Line length choke-device 200mm Armature choke Type EI135A-12 Line length choke-device 200mm Power supply with isolation transformer: Transformer with filter Type TE17/3F Line length transformer-device 200mm Armature choke Type EI135A-12 Linelength choke-devive 200mm Control signals: all wires twisted <1.5m no shield.

16

Page 17

5 Guarantee UNITEK products have a warranty against defects in material and workmanship for a period of one year from the date of shipment. All values from the pre- and final quality control checks are archivied with the devices’ serial numbers. UNITEK does not guarantee the suitability of the device for any specific application. During the warranty period, UNITEK will, at its option, either repair or replace products that prove to be defective, this includes guaranteed functional attributes. UNITEK specifically disclaims the implied warranties or merchantability and fitness for a particular purpose. For warranty service or repair, this product must be returned to a service facility designated by UNITEK. For products returned to UNITEK for warranty service, the Buyer shall prepay shipping charges to UNITEK and UNITEK shall pay shipping charges to return the product to the Buyer. However, the Buyer shall pay all shipping charges, duties, and taxes for products returned to UNITEK from another country. The foregoing warranty shall not apply to defects resulting from: * improper or inadequate repairs effected by the Buyer or a third party, * non-observance of the manual which is included in the all consignments, * non-observance of the electrical standards and regulations * improper maintenance * acts of nature All further claims on transformation, diminution and replacement of any kind of damage, especially damage, which does not affect the UNITEK device, cannot be considered. Follow-on damage within the machine or system, which may arise due to malfunction or defect in the device cannot be claimed. This limitation does not affect the product liability laws as applied in the place of manufacture (i. e. Germany). UNITEK reserves the right to change any information included in this MANUAL. All connection circuitry discribed is meant for general information purposes and is not mandatory. The local legal regulations, and those of the Standards Authorities have to be adhered to. UNITEK does not assume any liability, expressively or inherently, for the information contained in this MANUAL, for the functioning of the device or its suitability for any specific application. All rights are reserved. Copying, modifying and translations lie outside UNITEK’s liability and thus are not prohibited. UNITEK’s products are not authorized for use as critical components in the life support devices or systems without express written approval. The onus is on the reader to verifiy that the information here is current.

C2.1-230/180-12f

17

Page 18

Classic C2.1 - 230/180 -12f

18

UniTek Industrie Elektronik GmbH, Hans-Paul-Kaysser-Str.1 D-71397 Leutenbach-Nellm. (b.Stuttgart)