Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 1 of 2

Manual Thyristor-Motor-Controller Classic C2.1 230/180-12 f, galvanic isolated, pages 1 to 9

Pages 1 to 9 of 18

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Unitek C2 230/180-12

Page 1

MANUAL Thyristor- Motor-Controller Classic C2.1 230/180 - 12 f galvanic isolated

Industrie Elektronik

Tel.: 07195/9283-0 Fax 07195/928329 email info@unitek-online.de Htt p:// www.unitek-online.de

Edition 1104-2

Page 2

Classic C2.1 - 230/180 -12f Content: 1

Basic information

Safety advice General information Technical data

3 4 5

2

Mechanical installation Dimensions

6

3

Electrical installation

4

Adjustment

5

2

Page

Connection plans Circuit diagram

7 8

Adjustment functions Command value, actual value Armature voltage regulation Current, speed controller Adjustment without measuring device EMC - Advice

10 11 12 13 14 16

Guarantee

17

Page 3

1 Basic information Electronic devices always involve the risk of failure. This manual has to be read carefully and must be understood

Caution High Voltage AC 230V~, DC 320V= by experts before installing or starting the device. If there are any doubts call your trader or the manufacturer. The C2 series is designed to regulate electrical currents; protection standard IP00. Instructions and rules: the devices and accessory components must be set up and connected according to the local technical regulations. In Germany they are: - EU-machine guide lines 89/392/EWG,84/528/EWG,86/663/EWG,72/23/EWG EN60204, EN50178, EN60439-1, EN60146, EN61800-3 IEC/UL IEC364, IEC664, UL508C, UL840 - VDE-regulation VDE100, VDE110, VDE160 - TÜV-regulations - Regulations of the professional guild VGB4 The user has to assure that: after - a failure of the device - an incorrect handling - a failure of the control unit etc. the drive is brought to a secure operating condition. Machines and installations are to be provided with supervisory and safety equipment, that is independent of the device. Adjustment - only by qualified personnel - adher to safety regulations Installation work - only when disconnected from all power lines. QS The devices are archived by the manufacturer with serial number and their test specifications. CE The EU-guide line 89/336/EWG with the EMC-Regulations EN 61000-2 and EN 61000-4 are observed.

C2.1-230/180 f

3

Page 4

Classic C2.1 - 230/180 -12f Thyristor-control-unit

- for inductive and resistive devices

Main applications

- speed-control of direct-current motors - 1quadrant mode, propel - Power up to 2160 Watt - tachometer regulation - armature voltage regulation with I*R compensation - torque control

Attributes

- cascade-control speed-current - rectangular voltage-current characteristic - on/off-switch logic - direct switchable mains connection

Compact single-circuit-board device

- plug-in screw terminal - galvanic isolation between control and power section - fully isolated power semiconductor - field rectifer

CAUTION: Tachometer regulation Device is

>>> galvanic isolated

Armature voltage regulation Device is

>>> high - resistive conection to the mains

Control-reference (clamp 5) must not be earthed.

4

Page 5

1 Basic information Technical data Limits power connection output voltage rated current input current power (electric) field voltage field current

Characteristic max. max. max. max. max.

230V~ +10%/-15% 180V= 12A= 13.2A~ 2160 W 210 V= 1 A= contol range accuracy

(d.c. tachometer) (excluding feedback error)

1:300 0.1% control range accuracy

(armature voltage)

1:50 3% control range accuracy

(torque regulation)

1:50 3% command value supply input command value actual value enable logic

Internal fuses

Accessories mains choke isolation transformer smothing choke

C2.1-230/180 f max. max. tipsafe

12V= , 10mA 12V= -180V= enabling time 100ms

F1 F2

2.5Aff 16Aff

K78-16 F TE17/3 F EI135A-12

5

Page 6 read from a scan by OCR; it may hold reading errors

Classsic C2.1 - 230/180 -12f

SUOISUSLUIG i \_/ | |

Oo ND) 34567 9 10 11 le 13 14 15, TLE PEE EL, Cee en nn a ee en a ae a ae ee se a se se a SS #eB2¢ CY azPeEwW 000000 & _| oO om m |S2 ler | m | oy} wo | Sl ec 1 3 | om |S3 @ @ So 8 aud

Edtaled x< ae)

vee 5A 2.5AF 116A FF 1 4xg4.2 | | aN & xX 8 9 10 if ie 13 14 15 Q@OOQOOGOOO

Q- Qrn Qu Qa Qu Qa Qn

160 170

190

Page 7

3 Electrical installation

Power supply Direct power supply line neutral mains choke

L N

Clamp - terminal Clamp X2:11 Clamp X2:12 K78-16 F

Supply with isolation transformer secondary voltage transformer type transformer fuse16A ff

Motor connection Motor- armature positive negative

230V~ TE16/3 (F)

clamp terminal clamp X2:9 clamp X2:8

Motor-field positive negative clamp clamp smoothing choke Type

EI135A-12

C2.1-230/180-12f

X2:15 X2:14

7

Page 8 read from a scan by OCR; it may hold reading errors

Classic C2.2 - 230/180 -12f

I

PS/0-f762 3g M * . I 5 || aT LB a p5/8-G-762_ 3G A2 | B B pS/8-5-762 3 3 SEBS | ted UniTek Industrie Elektronik GmbH = obec) Industriestr. 1 wwwunitek-onlinede a 71397 Nellmersbach Tel +49 - 7195- - 92830 4 02.08.2004 Projekt c2-9b Blatt C2 2 Gotu | Merme fir Bat | oa i 6 bs | 5

Connection diagram

Page 9 read from a scan by OCR; it may hold reading errors

3 Electrical installation sjuauodWwod Buipying

(Q6-Z2 =#700Z'B0'Z0 66'L) URI

Z Qe qd 0z4 o & a Ai Od U4 uw oO 6 8 Wi Gi wd G4

EFL B/5C

£9 5 4+ E 2S al oN

Cer)

VZL7ENOLZ Oneee & | | | awl ees dai

J Ay

<"

MS ULY 2) er

Q0/SZHISd = beCHSe\08

N= co S

SLHOTIEWOYLS

Exiuaa-]

E co) Be = SE a eee

HL] Esbaba iz at RRR it, Haig 8 eat

Fag na wi a LEE alle

€ GG sa) Fai Gara oH

“he oF BEBO re ce Ad reall? ‘Th oa! Co) GE) OT Ge) UECe ==

Fdbdided PHEdEd dba aaae ae /* Ms BAT) SOR AA RA eo

+[+aaaadd @

ZI SVU PO WL = 1d

(23) 4eLIun

__ £228 ae

C2.1-230/180-12f