For the ABL Sursum 3B16UM
Page 61
MSS 2004 AK01
06.03.2004
13:56 Uhr
MSS 2004 AK01
Seite 3
06.03.2004
13:56 Uhr
Seite 3
SWITCHING DEVICES MANUAL MOTOR CONTROLLER MS Technical Data
Motorschutzschalter Motorschutzschalter Technische Daten
Back-up-protection MS UL and CSA Rating
EN and IEC Rating Technische Daten
Back-up fuse (gL, aM) [A] Interrupting Fuse Group Fusing Voltage Type Capacity [A] der Kurzschlussstrom [A] [V] Back-Up-Schutz MS (wenn das Schaltvermögen des MS [kA]übersteigt) 230 V 400 V 500 V Vorsicherung (gL, aM) (A)des MS übersteigt) Back-Up-Schutz MS (wenn der Kurzschlussstrom das Schaltvermögen Einstellwerte 230 V 400 V 500 V 690 V Vorsicherung (gL, aM) (A) MS016 1 100 600 5 No back-up fuse necessary. 0,16 A 230 600 V 500 V 690 V MS025 1 Einstellwerte 100 5 400 V Inherently stable for any selected 0,25 A bei beliebig hohen 0,16 A MS040 1 100 600 5 short circuit currents 0,4 A Kurzschlussströmen keine 0,25 A bei beliebig hohen MS0630,63 A 2 100 600 0,4 A Kurzschlussströmen keine Vorsicherung5 erforderlich MS1 1 A 4 100 600 5 0,63 A Vorsicherung erforderlich 1A MS1.61,6 A 6 100 600 5 1,6 A 25 20 MS2.52,5 A 10 100 600 5 25 2,5 A 25 20 4A 35 25 MS4 15 100 600 5 35 4A 35 25 6,3 A 50 35 MS6.3 25 50 600 5 50 35 6,3 A 50 10 A 80 50 35 10 A 50 MS10 16 A 40 600 80 5 80 80 35 50 35 80 63 16 A 80600 63 MS16 20 A 60 5 80 80 50 63 35 80 80 63 80 20 A 80 80 63 50 80 63 80 MS20 25 A 60 480 80 5 80 50 63 25 A 80 80 63 50 32 A 80 80 63 50 MS25 70 480 5 80 80 63 32 A
80
Back-Up-Schutz BS Back-Up-Schutz BS Einstellbereich Vorsicherung Einstellbereich (A) (A)(A) 0,4 – 0,63 2 FILE E137938 0,4 – 0,63 0,63 – 1 0,63 –4 1 1 – 1,6 6 1 – 1,6 1,6 – 2,5 1,6 – 6 2,5
120
Einstellbereich Vorsicherung (A) (A) 22,5 – 4 44 – 6,3 6,3 – 10 6 610 – 16
80
Vorsicherung Einstellbereich (A) (A) 2,5 – 4 10 4 – 6,3 16 6,3 – 1025 10 – 1635
63
Einstellbereich Vorsicherung (A) (A) 10 16 – 20 16 20 – 25
Vorsicherung Einstellbereich (A) (A) 16 – 20 50 20 – 25 50
20 25 35 35 35 50 50
Vorsicherung (A) 50 50
25 35
1,05-1,2 x In
120
1,05-1,2 x In
40
Minutes
40
Minutes
50
690 V
10 4
10 4
1
1
3-pole tripping
3-pole tripping 10
10
MPCB BS
MPCB BS
4
4
2-pole tripping
2-pole tripping
1
1 0,4
0,4 upper setting short circuit tripping at lower setting
10-1
10-1
Seconds
4x10-2
4x10-2
Seconds upper setting short circuit tripping at lower setting
10-2
10-2 4x10-3
100
4x10-3 10-3 1
10-3 1
2
3
4
5 6
8 10
16 14
20 22
40
100 x Rated currentMotorschutzschalter MS 016 – MS 16 Auslösekennlinie Motorschutzschalter MS 016 – MS 16 Auslösekennlinie
CHARACTERISTIC FOR MS016 – MS16
2
3
4
5 6
8
10 x Rated current
12,5 17,5 14 20
40
Motorschutzschalter MS 20 – MS 32 Auslösekennlinie Motorschutzschalter MS 20 – MS 32 Auslösekennlinie CHARACTERISTIC FOR MS20 – MS25
4/3
4/3
61
Page 62
SWITCHING DEVICES MANUAL MOTOR CONTROLLER MS Dimension Drawings
Motor protective circuit breaker MS 45
35,5
42
45
80
76,5
Mounting dimensions
30
63
71,5 75,5 85,5
Insulated enclosure MS.G55 38 M20
140
Mounting dimensions
M20
90
150
80
140
97,5
M20
90 possible to integrate 1 MPCB and 2 side mounted auxiliary contacts
55
M20 55
70-72
6 max.
85,5
70-72
64
110
116-118
104
130
M4
45°
R4 81
15
Emergency-stop button MS.PT – PS.PS2 95 54 27
MS.PT
62
55,5 28,5
MS.PV
68 37
MS.PS2
33-34
116-118
Insulated flush mounting enclosure MS.F55
Page 63
Horsepower rating and Kilowatt rating Horsepower [hp]
Wire cross section in AWG and mm²
Kilowatt [kW]
AWG No.
Cross section [mm2]
Diameter [mm]
0.167
0.13
21
0.412
0.724
0.25
0.184
20
0.519
0.813
0.5
0.38
19
0.653
0.912
0.75
0.55
18
0.824
1.27
1
0.735
17
1.01
1.151
1.25
0.919
16
1.307
1.29
1.5
1.103
15
1.651
1.45
1.75
1.287
14
2.082
1.628
2
1.471
13
2.627
1.829
2.5
1.839
12
3.307
2.052
3
2.206
11
4.169
2.304
4
2.942
10
5.26
2.588
5
3.677
9
6.633
2.906
6
4.413
8
8.367
3.264
7
5.148
7
10.55
3.665
7.5
5.516
6
13.229
4.115
8
5.884
5
16.767
4.62
9
6.619
4
21.148
5.189
10
7.355
3
26.667
5.827
11
8.09
2
33.624
6.543
12
8.826
1
42.406
7.348
13
9.561
1/0
53.182
8.252
14
10.297
2/0
67.43
9.266
15
11.032
3/0
85.014
10.404
16
11.768
4/0
107.22
11.684
63
Page 64
Page 65
UL 1077 UL 1077 AND CSA-22.2 NO. 235 COMPLIANT SWITCHING DEVICES
Our range of UL 1077 supplementary protectors can be used where additional protection is required in control circuits. Combined with the accessories from our UL 508 UM range it also offers enhanced monitoring and control capabilities.
65
Page 66
SWITCHING DEVICES SUPPLEMENTARY PROTECTOR according to UL 1077 and CSA-22.2 No.235 · UR Product Range, B, C and D Characteristics
RATED CURRENT IN A
CHARACTERISTIC B ITEM NO.
C ITEM NO.
D ITEM NO.
WEIGHT G / EACH
PACKING UNIT
1-pole 0.5
FILE E 137915
1C05UR
1D05UR
150
12
1
1B1UR
1C1UR
1D1UR
150
12
2
1B2UR
1C2UR
1D2UR
150
12
3
1B3UR
1C3UR
1D3UR
150
12
4
1B4UR
1C4UR
1D4UR
150
12
5
1B5UR
1C5UR
1D5UR
150
12
6
1B6UR
1C6UR
1D6UR
150
12
8
1B8UR
1C8UR
1D8UR
150
12
10
1B10UR
1C10UR
1D10UR
150
12
12
1B12UR
1C12UR
1D12UR
150
12
13
1B13UR
1C13UR
1D13UR
150
12
15
1B15UR
1C15UR
1D15UR
150
12
16
1B16UR
1C16UR
1D16UR
150
12
20
1B20UR
1C20UR
1D20UR
150
12
25
1B25UR
1C25UR
1D25UR
150
12
30
1B30UR
1C30UR
1D30UR
150
12
32
1B32UR
1C32UR
1D32UR
150
12
40
1B40UR
1C40UR
1D40UR
150
12
50
1B50UR
1C50UR
1D50UR
150
12
60
1B60UR
1C60UR
1D60UR
150
12
63 *
1B63UR
1C63UR
1D63UR
150
12
2C05UR
2D05UR
300
6
2C1UR
2D1UR
300
6
2C2UR
2D2UR
300
6
* 63 A without UL approval
2-pole 0.5 1
2B1UR
2
FILE E 137915
3
2B3UR
2C3UR
2D3UR
300
6
4
2B4UR
2C4UR
2D4UR
300
6
5
2B5UR
2C5UR
2D5UR
300
6
6
2B6UR
2C6UR
2D6UR
300
6
8
2B8UR
2C8UR
2D8UR
300
6
10
2B10UR
2C10UR
2D10UR
300
6
12
2B12UR
2C12UR
2D12UR
300
6
13
2B13UR
2C13UR
2D13UR
300
6
15
2B15UR
2C15UR
2D15UR
300
6
16
2B16UR
2C16UR
2D16UR
300
6
20
2B20UR
2C20UR
2D20UR
300
6
25
2B25UR
2C25UR
2D25UR
300
6
30
2B30UR
2C30UR
2D30UR
300
6
32
2B32UR
2C32UR
2D32UR
300
6
40
2B40UR
2C40UR
2D40UR
300
6
50
2B50UR
2C50UR
2D50UR
300
6
60
2B60UR
2C60UR
2D60UR
300
6
63 *
2B63UR
2C63UR
2D63UR
300
6
* 63 A without UL approval
66
Page 67
SWITCHING DEVICES SUPPLEMENTARY PROTECTOR according to UL 1077 and CSA-22.2 No.235 · UR Product Range, B, C and D Characteristics
RATED CURRENT IN A
CHARACTERISTIC B ITEM NO.
C ITEM NO.
D ITEM NO.
WEIGHT G / EACH
PACKING UNIT
3-pole 0.5
FILE E 137915
3C05UR
3D05UR
450
4
1
3B1UR
3C1UR
3D1UR
450
4
2
3B2UR
3C2UR
3D2UR
450
4
3
3B3UR
3C3UR
3D3UR
450
4
4
3B4UR
3C4UR
3D4UR
450
4
5
3B5UR
3C5UR
3D5UR
450
4
6
3B6UR
3C6UR
3D6UR
450
4
8
3B8UR
3C8UR
3D8UR
450
4
10
3B10UR
3C10UR
3D10UR
450
4
12
3B12UR
3C12UR
3D12UR
450
4
13
3B13UR
3C13UR
3D13UR
450
4
15
3B15UR
3C15UR
3D15UR
450
4
16
3B16UR
3C16UR
3D16UR
450
4
20
3B20UR
3C20UR
3D20UR
450
4
25
3B25UR
3C25UR
3D25UR
450
4
30
3B30UR
3C30UR
3D30UR
450
4
32
3B32UR
3C32UR
3D32UR
450
4
40
3B40UR
3C40UR
3D40UR
450
4
50
3B50UR
3C50UR
3D50UR
450
4
60
3B60UR
3C60UR
3D60UR
450
4
63 *
3B63UR
3C63UR
3D63UR
450
4
* 63 A without UL approval
RATED CURRENT IN A
RATED VOLTAGE VOLT AC
TEST CURRENTS * ELECTROMAGNETIC NOT TRIPPING I4 A
TRIPPING I5 A
ITEM NO.
WEIGHT G / EACH
PACKING UNIT
N63UM
150
5
Neutral switch – for mounting instructions please consult page 75 0.3 - 63
277/480
400
700
* additional electromagnetic protection
FILE E137938
67
Page 68
ACCESSORIES FOR SWITCHING DEVICES
Manual Motor Controller and Supplementary Protectors according to UL 508 and CSA-22.2 No.14 for Product Ranges UM and UR
Mounting Instructions of Accessories Applies to N...UM and FA...UM: The accessory devices N...UM and FA...UM can be installed on the right or left. The auxiliary contact H...UM can only be installed on the right. Mounting: 1. Flick the blue switches of all devices to the “OFF” position 2. Remove the grey cover from the switching device and attachment 3. Insert the drive plate between the switching device and N...UM or FA...UM 4. Insert the connecting pin into the switch (insertion depth approx. 7 mm) 5. Attach switching device to N...UM or FA...UM 6. Tighten the connecting srews (observe the the correct srew length)
5. 6. 7mm
1.
Mounting screw 34 mm (see accessories page 25)
4. 3.
6.
24 mm
2.
Switching device
Neutral switch/ Shunt trip
Neutral switch/ Shunt trip
Applies to H...UM: The auxiliary contact H...UM can only be installed on the right.
3. 4.
Installation: 1. Flick the blue switches of all devices to the “OFF” position 2. Remove the grey cover from the switching device 3. Attach switching device to H...UM 4. Insert the connecting screws and fasten them by a 90° clockwise turn 5. After installation close and open the switch to check operation Applies to all switching devices ...UM, ...UR, N63UM and FA...UM Design of the terminals · Optical detection of screw position · Increased breaking resistance if the screwdriver becomes jammed · Universal connecting terminals, suitable for connecting all known cable lugs such as ring or forked cable lugs and pin terminals · Ring cable lugs can be connected by opening the flap and removing the connecting screw · Can also be used for applications that require ring cable lugs (e.g. nuclear power stations) · DIN EN 50274, VDE 0660-514 compliant protection against contact with live parts is fully guaranteed 68
Auxiliary contact
90°
1.
2.
Switching device
1
Auxiliary contact
2
1. Box terminal for
·· solid conductors ·· flexible conductors with or without cable lug
3
2. Screw terminal for forked cable lug
3. Screw terminal for ring cable lug (ring tongue)
Page 69
ACCESSORIES FOR SWITCHING DEVICES
Manual Motor Controller and Supplementary Protectors according to UL 508 and CSA-22.2 No.14 for Product Ranges UM and UR
Auxiliary contact FILE E137938
CONTACTS
ITEM NO.
WEIGHT G / EACH
PACKING UNIT
1 auxiliary contact
1NO
H10UM
35
10
2 auxiliary contacts
1NO + 1NC
H11UM
40
10
3 auxiliary contacts
1NO + 2NC
H12UM
45
10
3 auxiliary contacts
2NO + 1NC
H21UM
45
10
MODULE
TYPE OF CONTACT
1/2 1/2 1/2 1/2
14
12
24
H10UM
H11UM
22 12
34
H12UM
11
12
24
H21UM
33
23
13
34
21
33 11
23
11
Standards
Acc. to IEC 60947-5-1, DIN EN 60947-5-1, VDE 0660-200, UL 508
Rated operating currents
10 A /240 V AC 3 A / 110 V DC 1 A / 220 V DC
Minimum contact load
1 mA at 24 V DC
Conductor cross sections Type of conductor *)
min.
max.
Single wire Stranded wire
1.0 mm2 (AWG18) 1.0 mm2 (AWG18)
2.5 mm2 (AWG14) 1.5 mm2 (AWG16)
Stranded wire with ferrule
1.0 mm2 (AWG18)
1.5 mm2 (AWG16)
Torque max. 0.8 Nm (7 lb.in)
*) Stripped length 8 - 9 mm
Shunt trip
MODULE
RATED OPERATING VOLTAGE
MAX. OPERATING CURRENT AT UN (T < 10 MS)
ITEM NO.
WEIGHT G / EACH
PACKING UNIT
5
FILE E137938
1
12 V UC
1.3 A
FA12UM
105
1
24 V UC
0.6 A
FA24UM
105
5
1
48 - 74 V UC
0.2 A
FA48UM
105
5
1
110 - 240 V UC, 415 V AC
0.25 A at 110 V
FA110UM
105
5
ITEM NO.
WEIGHT G / EACH
PACKING UNIT
EASS
2
10
0.5 A at 240 V 0.58 A at 277 V
Activation lock
DIMENSION DRAWING FA..UM, N63UM
69
Page 70
SWITCHING DEVICES SUPPLEMENTARY PROTECTOR according to UL 1077 and CSA-22.2 No.235 · Product Range UR, B, C and D Characteristics · Technical Data
Characteristic
B
C
D
Application
Lighting Control circuits General electronics Wiring protection Business equipment Appliances
Lighting Control circuits Wiring protection Business equipment Appliances
Control transformers Power supplies Reactive loads
Number of poles
1 - 3; 1 + N; 3 + N
Standards
UL 1077 and CSA-22.2 No.235
Interrupting capacity Current limiting class see data sheet for use in the USA and Canada (page 75) 3
3
Max. back-up fuse see data sheet for use in the USA and Canada (page 75)
Rated voltage AC
Test currents
Rated current range
0.5 - 63* A
0.5 - 63* A
Thermal not tripping I1 (A) > 1 h
1.13 x In
1.13 x In
1.13 x In
Thermal tripping I2 (A) < 1 h
1.45 x In
1.45 x In
1.45 x In
Electromagnetic not tripping I4 (A) > 0,1 s
3 x In
5 x In
10 x In
Electromagnetic tripping I5 (A) < 0,1 s
5 x In
10 x In
16 x In
Reference calibration temperature of the thermal tripping threshold
70
30° C + 5° C Influence of the ambient temperature on the thermal release threshold: Decrease of the current values with higher ambient temperature and increase with lower temperatures of approximately 5% per 10°C difference in temperature
Frequency range of the electromagnetic trip
16 2/3 to 60 Hz
Ambient temperature
-25 °C to +55 °C
Storage temperature
-40 °C to +70 °C
Device depth according to DIN 43880
68 mm
Mechanical live
10,000 cycles (ON / OFF)
Protection cover
Finger safe and safe to back of hand according to DIN EN 50274/ VDE0660-514
Insulation group acc. to DIN/VDE 0110
C at 250 V AC B at 400 V AC
Degree of protection acc. to EN/IEC 60529
IP20
Installation position any
Mounting
DIN-rail according to DIN EN 60715 35 mm
Lockability
The handle can be secured against manual switching in the on and off position by a lead seal
Climatic resistance
Humid heat constant according to DIN EN 60068-2-78 Humid heat cycle according to DIN EN 60068-2-30
Vibration resistance
> 15 g according to DIN EN 60068-2-59 during a load with I1
Resistance to mechanical shocks
25g 11ms
* 63 A without UL approval
FILE E137915
277 / 480 V 1 - 63* A