Page 151

Serial Communications

B-9

Table B.4 Parameter Grouping/User Settings (continued)

Faults

Output Config

Feature Select

Group Parameter Name Run On Power Up Reset/Run Tries Reset/Run Time S Curve Enable S Curve Time Language Cable Length Rated Slip Slip Comp Adder IR Comp % Output 1 Config Output 2 Config Analog Out Sel Above Freq Val Above Curr Val Fault Buffer 0 Fault Buffer 1 Fault Buffer 2 Fault Buffer 3 Clear Fault Cur Lim Trip En Line Loss Fault Flt Clear Mode

Parameter Number

Display Units

Drive Units Scale Factor ➁

14 85 15 57 56 47 143 146 148 147 90 91 25 77 142 86 87 88 89 51 82 40 39

Text ➀ Numeric Seconds Text ➀ Seconds Text ➀ Text ➀ Hz Hz % Text ➀ Text ➀ Text ➀ Hz % Numeric Numeric Numeric Numeric Text ➀ Text ➀ Text ➀ Text ➀

1 1 100 1 10 1 1 10 100 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Minimum –– 0 0.5 –– 0.0 –– –– 0.0 0.00 0% –– –– –– 0 0 –– –– –– –– –– –– –– ––

➀ Refer to Table B.1 on pages B-13, B-14 and B-15 for the numerical equivalent of the text descriptions. ➁ Refer to page B-2.

Maximum –– 9 30.0 ––– 300.0 –– –– 5.0 5.00 150% –– –– –– 400 150% of Drive Rated Current (DRC) –– –– –– –– –– –– –– ––

Factory Setting Disabled 0 1.0 Disabled 0.0 Appropriate Lang. Short 2.0 –– Drive Size Depend. Faulted Running Frequency 0 0 –– –– –– –– Ready Default Run F03 Enable Enabled

User’s Setting

Page 152

B-10

Serial Communications

Table B.4 Parameter Grouping/User Settings (continued)

Masks

Diagnostics

Group Parameter Name Drive Command Drive Status Drive Alarm Input Status Freq Source Freq Command Drive Direction Motor Mode Power Mode Drive Type Firmware Ver. Output Pulses Drive Temp Set Defaults Logic Mask Direction Mask Start Mask Jog Mask Reference Mask Accel Mask Decel Mask Fault Mask MOP Mask Local Mask

Parameter Number

Display Units

Drive Units Scale Factor ➁

58 59 60 55 62 65 69 43 44 61 71 67 70 64 92 94 95 96 97 98 99 100 101 93

Byte Text ➀ Byte Byte Text ➀ Hz Text ➀ Text ➀ Text ➀ Numeric Numeric Cycles Degrees C Text ➀ Byte Byte Byte Byte Byte Byte Byte Byte Byte Byte

–– –– –– –– 1 100 1 1 1 1 1 256 = 1 rev 1 1 –– –– –– –– –– –– –– –– –– ––

Minimum –– –– –– –– –– 0.00 –– –– –– –– –– 0 0 –– –– –– –– –– –– –– –– –– –– ––

➀ Refer to Table B.1 on pages B-13, B-14 and B-15 for the numerical equivalent of the text descriptions. ➁ Refer to page B-2.

Maximum –– –– –– –– –– 400.00 –– –– –– –– –– 65535 100 –– –– –– –– –– –– –– –– –– –– ––

Factory Setting –– –– –– –– –– 0.00 Forward –– –– –– –– –– Ready 01111111 01111111 01111111 01111111 01111111 01111111 01111111 01111111 01111111 01111111

User’s Setting

Page 153

Serial Communications

B-11

Table B.4 Parameter Grouping/User Settings (continued)

Adapter I/O

Owners

Group Parameter Name Stop Owner Direction Owner Start Owner Jog Owner Reference Owner Accel Owner Decel Owner Fault Owner MOP Owner Local Owner Data In A1 Data In A2 Data In B1 Data In B2 Data In C1 Data In C2 Data In D1 Data In D2 Data Out A1 Data Out A2 Data Out B1 Data Out B2 Data Out C1 Data Out C2 Data Out D1 Data Out D2 ➀ Refer to page B-2.

Parameter No. 102 103 104 105 106 107 108 109 110 137 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126

Display Units Byte Byte Byte Byte Byte Byte Byte Byte Byte Byte Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric Numeric

DU Scale Factor ➀ –– –– –– –– –– –– –– –– –– –– 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Minimum –– –– –– –– –– –– –– –– –– –– 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

Maximum –– –– –– –– –– –– –– –– –– –– 149 149 149 149 149 149 149 149 149 149 149 149 149 149 149 149

Factory Setting –– –– –– –– –– –– –– –– –– –– 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

Setting

Page 154

B-12

Serial Communications

Table B.4 Parameter Grouping/User Settings (continued)

Process Display

Group Parameter Name Process Par

Parameter Number

Display Units

Drive Units Scale Factor ➁

127

Numeric

1

Minimum 1

Process Scale

128

Numeric

100

–327.68

+327.67

+1.00

Process Text 1

129

ASCII Text

––

––

––

?

Process Text 2

130

ASCII Text

––

––

––

––

Process Text 3

131

ASCII Text

––

––

––

––

Process Text 4

132

ASCII Text

––

––

––

––

Process Text 5

133

ASCII Text

––

––

––

––

Process Text 6

134

ASCII Text

––

––

––

––

Process Text 7

135

ASCII Text

––

––

––

––

Process Text 8

136

ASCII Text

––

––

––

––

➀ Refer to Table B.1 on pages B-13, B-14 and B-15 for the numerical equivalent of the text descriptions. ➁ Refer to page B-2.

Maximum 149

Factory Setting 1

User‘s Setting

Page 155

Serial Communications

B-13

Table B.1 “Display Unit” Equivalent to Parameter Text Descriptions Parameter Number

Parameter Name

Text

Display Unit

Parameter No.

Parameter Name

Text

Display Unit

5

Freq Select 1

“Remote Pot”

1

9

DC Boost Select

“Fan Sel #1”

0

6

Freq Select 2

“0-10 Volt”

2

“Fan Sel #2”

1

62

Freq Source

“4-20 mA”

3

“No Boost”

2

“MOP”

4

“6 volts”

3

“Adapter 1”

5

“12 volts”

4

“Adapter 2 ”

6

“18 volts”

5

“Adapter 3”

7

“24 volts”

6

“Adapter 4”

8

“30 volts”

7

“Adapter 5”

9

“36 volts”

8

“Adapter 6”

10

“42 volts”

9

“Preset 1”

11

“48 volts”

10

“Preset 2”

12

“Break Point”

11

“Preset 3”

13

“Run Boost”

12

“Preset 4”

14

“Coast”

“Preset 5”

15

“DC Brake”

“Preset 6”

16

“Ramp”

“Preset 7”

17

“S-Curve”

0 1 2 3

“Jog Sel ”➀

18

10

Stop Select

➀ Valid for parameter (62) [Freq Source] only.

Page 156

B-14

Serial Communications

Table B.1 “Display Unit” Equivalent to Parameter Text Descriptions (continued) ParameterNumber

Parameter Name

Text

11

DB Enabled

“Disabled”

14

Run On Power Up

21

25

Input Mode

Analog Out Sel

Display Unit

Parameter No.

Parameter Name

Text

40

Line Loss Fault

“F03 Enable”

“Enabled”

0 1

Disabled

0

41

Motor Type

Enabled

1

“Three Wire” “Run Fwd/Rev”

0 1

“3 W/2nd Acc”

“Sync PM”

0 1 0 1

‘‘Invalid”

0

‘‘Zero Mode”

1

2

‘‘Accel Mode”

2

“Run F/R 2nd A”

3

‘‘At Hz Mode”

3

“3 Wire/MOP”

4

‘‘Decel Mode”

4

“Run F/R MOP”

5

‘‘Coast Mode”

5

0 1 2 3

‘‘Braking Mode”

6

‘‘Faulted Mode”

7

‘‘Invalid”

0

‘‘First Mode”

1

4

‘‘Charge Mode”

2

0

‘‘Wait Mode”

3

‘‘Test Mode”

4

‘‘Line Loss Mode”

5

‘‘Idle Mode”

6

‘‘Active Mode”

7

‘‘Braking Mode”

8

‘‘Faulted Mode”

9

“Frequency” “Current” “BusVolts” “Power” “Output Volts”

26

Preset/2nd Accel

“Preset” “2nd Accel”

37

Overload Mode

“No Derating” “Min Derate” “Max Derate”

39

Fault Clear Mode

Display Unit

1 0 1 2

Disabled

0

Enabled

1

“Uvolt Run”

43

44

Motor Mode

Power Mode

“Induc/Reluc”

Page 157

Serial Communications

B-15

Table B.1 “Display Unit” Equivalent to Parameter Text Descriptions (continued) Parameter No.

Parameter Name

Text

47

Language

“English”

51

Clear Fault

64

Text

82

Curr Lim Trip En

“Default Run“

84

Analog Invert

Display Unit

“Comp.” S-Curve Enable

Disabled

0

“Running”

Enabled

1

“Faulted”

Set Defaults

“Ready”

“Alarm” ‘‘Above Curr”

5

“Short“

0

“Long”

1

0%

“Reverse”

0 1 2 3 0 1

Disabled

0

50%

Enabled

1

75%

0 1 2 3

“Min/Alarm”

0 1 2 3 4

100%

4

Disabled

0

Enabled

1

Compensation

“No Comp.”

“Store to EE” “Recll frm EE” “Default Init” 69

Parameter Name

0 1 2 3 4

“Ready” “Clear Fault”

57

Parameter No.

0 1 0 1 0 1

“Alternate Language”

52

Display Unit

Drive Direction

72

Upper Presets

81

4-20mA Loss Sel

“Forward”

“Stop/Fault” “Hold/Alarm” “Max/Alarm” “Pre1/Alarm”

“Trip @ I Lmt”

0 1

Disabled

0

Enabled

1

90

Output Config 1

“At Speed”

91

Output Config 2

“Above Freq”

143 144

Cable Length Analog Filter

25%

149

Adaptive I Lim

Page 158

B-16

Serial Communications

This Page Intentionally Left Blank.