Page 1 of High-Speed Counter Module (Catalog Number 1746-HSCE) Installation Instructions

Manual · Allen-Bradley

High-Speed Counter Module (Catalog Number 1746-HSCE) Installation Instructions

Manual24 pagesPDF 325 KB

Installation instructions for the Allen-Bradley 1746-HSCE high-speed counter module for SLC 500: switches, wiring and specs.

Download the PDF325 KB

Covers · 1 model

The models it covers

Summary

What is in it

Installation instructions for the Allen-Bradley 1746-HSCE High-Speed Counter Module, an SLC 500 module for quadrature encoders and high-speed switches. It gives a module overview, the DIP switch and jumper settings for input type, output voltage range and limit switch filtering, how to install the module and wire its removable terminal block, wiring considerations, input, output, encoder, discrete device and limit switch wiring, and the specifications.

Its parts

  1. For More Information
  2. Hazardous Location Considerations
  3. High-Speed Counter Module Overview
  4. Dip Switch and Jumper Locations
  5. Install the Module
  6. Remove the Terminal Block
  7. Wire the Removable Terminal Block
  8. Important Wiring Considerations
  9. Input and Output Connections
  10. Outputs
  11. Encoders
  12. Single-Ended Wiring (Discrete Devices)
  13. Limit Switch Wiring
  14. Specifications

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Installation instructions (publication 1746-IN011C-EN-P, April 2005) for the Allen-Bradley 1746-HSCE High-Speed Counter Module for the SLC 500. They cover the dip switch and jumper settings, installing the module, wiring outputs, encoders, sensors and limit switches, and the specifications.

What it is
High-speed counter module with bidirectional counting and x2 and x4 modes for quadrature encoders p. 5
Compatibility
SLC 500 family, SLC 5/02 and above processors; not compatible with the 1747-ASB Remote I/O Adapter Module p. 5
Max input frequency
50k Hz; rate measurement up to 32,767 Hz in Sequencer and Range Modes p. 5
Inputs
A, B and Z, each set to differential or single-ended by SW1, plus an LS limit switch input for 5, 12 or 24V dc p. 8, 9
Outputs
Four open collector sinking outputs, 4.5 to 10V dc or 10 to 30V dc range set by SW2 p. 5, 8
Output current
Max 125 mA at 30V dc, 40 mA at 10V dc, 16 mA at 4.5V dc p. 21
Backplane current
320 mA at +5V dc, 0 mA at +24V dc p. 20
Input ON range
Differential 2.8 to 4.5V dc; single-ended 3.1 to 5.5V dc p. 8
LS input ON range
LS (24V dc) 16.5 to 30V dc; LS (12V dc) 9.4 to 16.5V dc p. 9
LS filter
Jumper JW1 selects 300 µs or 10 ms debounce; default 10 ms p. 6, 7
Cable
Shielded Belden 9503 or equivalent for A, B and Z, up to 305 m (1000 ft) p. 12
Isolation
1500 volts from the backplane p. 20
Operating temperature
0° C to +60° C (+32° F to +140° F); humidity 5 to 95% without condensation p. 20
Terminal block
Removable; two #14 AWG wires per terminal; screw torque 0.7 to 0.9 Nm (6 to 8 in-lbs.) p. 11

What this manual walks you through

  • Setting dip switches SW1 and SW2 and jumper JW1 before installing p. 6, 7, 8, 9
  • Installing the module in the SLC chassis p. 10
  • Removing and wiring the removable terminal block p. 11
  • Planning the system wiring, shielding and grounding p. 12
  • Wiring the four sinking outputs p. 14
  • Wiring differential encoders such as the 845H Series p. 15
  • Wiring single-ended encoders and choosing pull-up resistors p. 16, 17
  • Wiring proximity, photoelectric and solid-state sensors p. 18
  • Wiring 24V, 12V and 5V limit switches p. 19

Good to know

  • All SW2 switches must be either ON or OFF together; a mix may cause permanent damage. p. 8
  • Running 10 to 30V dc outputs with SW2 set for 4.5 to 10V dc damages the module. p. 8
  • Connect only one LS input range at a time, or the module is damaged. p. 9
  • Do not use incandescent lamps as output indicators; use LED indicators within the output ratings. p. 14
  • The Allen-Bradley 845H sourcing encoder is not compatible with this module. p. 17

Questions this manual answers

Which processors work with the 1746-HSCE?

SLC 5/02 and above processors in the SLC 500 family; it is not compatible with the 1747-ASB Remote I/O Adapter Module. p. 5

What is the maximum count frequency of the 1746-HSCE?

Input pulses up to 50k Hz; background rate measurement accepts up to 32,767 Hz in Sequencer and Range Modes. p. 5

How much backplane current does the 1746-HSCE draw?

320 mA at 5V dc. p. 10

How do I set the 1746-HSCE output voltage range?

Set all SW2 switches ON for 4.5 to 10V dc or all OFF for 10 to 30V dc; never mix them. p. 8, 14, 21

What cable should be used for 1746-HSCE encoder inputs?

Shielded Belden 9503 or equivalent, for lengths up to 305 m (1000 ft). p. 12

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. High-Speed Counter Module1
    1. For More Information3
    2. Hazardous Location Considerations4
    3. Environnements dangereux4
    4. High-Speed Counter Module Overview5
    5. Dip Switch and Jumper Locations6
    6. Install the Module10
    7. Remove the Terminal Block11
    8. Wire the Removable Terminal Block11
    9. Important Wiring Considerations12
    10. Input and Output Connections13
    11. Outputs14
    12. Encoders15
    13. Single-Ended Wiring (Discrete Devices)18
    14. Limit Switch Wiring19
    15. Specifications20
  2. Back Cover24

From the PDF’s own bookmarks.

The whole text · 3 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16
  3. Pages 17 to 2417-24

The file

Revision and size

Part no.1746-IN011C-EN-P
RevisionApril 2005
PublisherRockwell Automation
Pages24
PDF325 KB
TextText from the PDF itself.
1746-IN011C-EN-P

The first pages · 3 of 24

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 24
Page 2
Page 2of 24
Page 3
Page 3of 24