The text of a manual · part 20 of 20
DH-485/RS-232C Interface Module, Catalog Number 1747-KE, User Manual, pages 135 to 139
Pages 135 to 139 of 139: Index; Back Cover
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 1747-AIC DH-485
Page 135
Index Numerics 1746-N2 card slot filler 4-16 1747-AIC link coupler 1-2 1747-C11 cable 4-11 1747-C13 cable 1-2, 4-11 1770-KF2 3-2
A addressing DF1 protocol 5-8, 5-9 DH-485 network 5-7 application examples 8-1 supplementary Data Echo feature 8-11 Real Time Clock 8-9 ASCII terminal configuration of 5-2 use to configure the module 5-1 auto answer, modem 1-5
B backplane communication 6-1 battery back-up C-1 lithium status 1-3, 7-2 baud rate, See "communication rate" 1-2
C cables 4-8 1747-C10 4-11 1747-C11 4-11 1747-C13 1-2, 4-11 DH-485 communication 4-11 RS-232 communication 4-9 RS-422 communication 4-9 RS-423 communication 4-9 card slot filler 4-16 chassis configure 4-13 CMD byte 3-11 communication between module and PLC-5 processor
B-2 between module and SLC 500 processor
B-2 example using the PLC-5 Message instruction B-4 slave-to-slave 1-10, 3-9 use a modem 3-11 communication rate CONFIG port 5-5 DF1 port 5-6, 6-9, 8-2, D-2, D-3 DH-485 port 5-7, 6-13, 8-2, D-2,
D-3 CONFIG port 1-2 parameter options 5-5 setup 4-5 setup menu 5-5 configuration ASCII terminal 5-2 chassis 4-13 interface module 4-15 from the SLC processor 6-2 use an ASCII terminal 5-1 use backplane communication 6-1 mode 1-4, 4-4 packets, building DF1 6-7 DH-485 6-12 modem initialization string 6-13 typical configurations full-duplex 1-6 half-duplex 1-9 worksheets D-1
D data echo 6-17 application example 8-11 Data Highway 3-2 definitions P-2 DF1 definition P-2 DF1 port 1-2 configuration 4-6 parameter options 5-6, 6-9 setup menu 5-5 DF1 protocol 3-1 DF1 protocol menu 5-8 full-duplex parameter options 5-9, 6-9 setup menu 5-8 half-duplex parameter options 5-10, 6-10 setup menu 5-10 DH-485 definition P-2 DH-485 port 1-2 connections 4-11 parameter options 5-7 setup menu 5-6 Publication 1747-UM005B-EN-P - March 2006
Page 136
2
Index diagnostics 7-3 use LED indicators 1-3, 7-2 display parameters menu 5-12
E equipment needed 2-1 error handling 7-3 European directives compliance 4-1 examples supplementary Data Echo feature 8-11 Real Time Clock 8-9 use the PLC-5 message instruction with byte B-4
I initialization string, modem 5-9, 5-11,
6-10, 6-11, D-2, D-3 input image 6-6, 7-2 status word 6-6, 7-2 installation 4-7 final steps 4-15 quick start procedures 2-2
J jumpers JW1 1-4, 4-5 JW2 1-4, 4-6 JW4 1-4, 4-4, 4-15
F fault code 7-3 features of module 1-2 full-duplex definition P-2 LED indicator 1-3 parameter options 5-9, 6-9 setup summary screen 5-12 typical configurations 1-6 functionality, select 4-2
G get started 2-1
L LED indicators 1-3, 7-1, 7-2 link coupler 1-2 connections 4-11 lithium battery disposal C-5 handling C-3 replacement C-1 status 1-3, 7-2 storage C-3 transportation C-3 local mode half-duplex DF1 protocol 3-3 slave-to-slave communication 3-10
H half-duplex definition P-3 function 3-2 LED 1-3 local mode 3-3 multidrop network 3-7 node addresses 3-8 parameter options 5-10 remote mode 3-4 setup summary screen 5-12 typical configurations 1-7, 1-9 hardware handshake 4-9 specifications Real Time Clock/calendar A-1
M manuals related P-2 menus CONFIG port 5-5 DF1 port 5-6 DF1 protocol 5-8, 5-9 DH-485 port 5-7 display parameters 5-12 top level 5-4 modem auto answer 1-5 communication setup 3-11 definition P-3 direct connect 1-5 DTE controlled answer 1-5 initialization string 5-9, 5-11, 6-10,
6-11, D-2, D-3 manual 1-5 Publication 1747-UM005B-EN-P - March 2006
Page 137
Index module configuration ID 1-4, 4-2 functionality 4-2 multidrop network 1-6
N node addressing 5-7 non-token passing devices 3-11
O output status word 6-6 overview of module 1-1
P phone line access 3-11 pin assignments 4-8 PLC command byte 3-11 PLC-5 communications message instruction B-2 with word B-3 polling 3-3 ports isolation 1-2 publications related P-2
Q quick start 2-1
3 definition P-3 selection 4-5, 4-6 RS-423 definition P-3 selection 4-5, 4-6 RS-485 definition P-3 selection 4-5, 4-6 Run mode 1-4, 4-4, 4-15
S series A functionality 4-2 series B functionality 4-2 setup summary full-duplex 5-12 half-duplex 5-12 slave-to-slave communication 1-9, 3-8 SLC processor communications B-1 configure 4-13 definition P-3 input status word 6-6 output status word 6-6 status bits 7-2 specifications Real Time Clock/calendar A-2 SRD message 3-11 status bits 7-2 status codes 6-7, 7-3 status word input 6-6 output 6-6 system configuration 4-13
R RAM definition P-3 Real Time Clock application example 8-9 remote mode half-duplex DF1 protocol 3-4 slave-to-slave communication 3-10 required tools and equipment 2-1 resetting the module from the SLC 6-18 RS-232 definition P-3 selection 4-5, 4-6 RS-422
T terms P-2 token passing 3-4 tools needed 2-1 Top Level Setup menu 5-3, 5-4 troubleshooting 7-1 typical configurations 1-6
W worksheets configuration D-1
Publication 1747-UM005B-EN-P - March 2006
Page 138
Page 139
Rockwell Automation Support
Rockwell Automation provides technical information on the web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com.
Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your module up and running: United States
1.440.646.3223 Monday – Friday, 8am – 5pm EST
Outside United States
Please contact your local Rockwell Automation representative for any technical support issues.
New Product Satisfaction Return Rockwell tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned: United States
Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process.
Outside United States
Please contact your local Rockwell Automation representative for return procedure.
SLC, SLC 500, RSLogix 500, PLC-2, PLC-5, Data Highway Plus, DTAM, Allen-Bradley, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 1747-UM005B-EN-P - March 2006 5 Supersedes Publication 1747-6.12 - January 1997
Copyright © 2006 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.