DH-485/RS-232C Interface Module, Catalog Number 1747-KE, User Manual
Manual139 pagesPDF 1.8 MB
User manual for the Allen-Bradley 1747-KE DH-485/RS-232C interface module for SLC 500 controllers, with DF1 and DH-485 setup.
What this file really is
The old site listed this file as a manual for the Allen-Bradley 1747-AIC DH-485. The file is named as a 1747-AIC manual, but it is the user manual for the 1747-KE DH-485/RS-232C interface module, which mentions the 1747-AIC only as the link coupler it connects through.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Allen-Bradley's user manual for the 1747-KE DH-485/RS-232C Interface Module, used with SLC 500 controllers. It describes the module's LEDs and jumpers, modem use and DF1 protocol, typical full-duplex and half-duplex configurations, a quick start, installation and cabling to the CONFIG, DF1 and DH-485 ports (including connection to a 1747-AIC link coupler), RSLinx driver setup, configuration from an ASCII terminal or over the backplane from the SLC processor, and how to read the LED indicators.
Its parts
- Preface
- Overview
- Quick Start
- Communicate with the Interface Module
- Installation and System Configuration
- Module Configuration with a Terminal Overview
- Module Configuration Using the Backplane
- Interpret the LED Indicators
From the manual
Key facts from this manual
Each line names its page in the PDF.
This Allen-Bradley user manual (publication 1747-UM005B-EN-P) covers the 1747-KE DH-485/RS-232C interface module, which sits in an SLC 500 chassis and bridges DH-485 networks to DF1 devices such as modems and computers. The 1747-AIC link coupler appears only as the device that joins the module to a DH-485 network. The manual explains installation, jumpers, cabling, LED indicators, status and fault codes, and battery replacement.
- Device
- 1747-KE DH-485/RS-232C interface module: a bridge between DH-485 networks and DF1 devices, in an SLC 500 chassis p. 13
- Ports
- CONFIG and DF1 (RS-232/423, RS-422 or RS-485) and DH485 (not isolated) p. 14
- Port speeds
- CONFIG and DF1: 300, 600, 1200, 2400, 4800, 9600 and 19200 Kbps (as printed) p. 14
- Link coupler
- A 1747-AIC link coupler is needed to join the DH485 port to a network with multiple SLC 500 processors p. 14
- DH-485 cables
- 1747-C11 or 1747-C13 to a 1747-AIC; 1747-C13 also connects directly to a single SLC processor p. 14
- Backplane power
- 0.150 A at 5V dc and 0.070 A at 24V dc (module only) p. 117
- Link coupler power
- With a 1747-C11 cable the 1747-AIC draws 0.085 A @ 24V dc through the module p. 117
- Battery
- Replaceable lithium battery 1747-BA, about five years of RAM back-up p. 125
- Temperature
- Operating 0...+60 °C (+32...+140 °F); storage -40...+85 °C (-40...+185 °F) p. 117
- Distance
- RS-232: 15 m (50 ft); RS-422 and RS-485: 1230 m (4000 ft) at every listed rate p. 119
- In the box
- 1747-KE module, 1747-C13 cable, installation instructions publication 1747-IN006 p. 24
- Series jumper
- JW4 horizontal: series A functionality (ID=4209); vertical: series B (ID=3509) p. 16
- Retainer clips
- Replacement retainer clips 1746-R15 (2 per package) p. 125
- Certification
- The manual states Class 1, Groups A, B, C, or D, Division 2; CE compliant; C-Tick marked p. 118
What this manual walks you through
- Installing the module and configuring the SLC chassis p. 24
- Setting the JW4 jumper for series A or B function and mode p. 16
- Building CONFIG and DF1 port cables from the pin assignments p. 46, 47, 48
- Connecting the DH-485 port to a 1747-AIC link coupler or an SLC processor p. 49, 50
- Choosing a modem to use with the module p. 17
- Reading LED error conditions and their solutions p. 86
- Interpreting status codes and SLC fault codes p. 87
- Replacing the lithium battery p. 125, 126
Good to know
- Do not use the module with a modem that answers the phone as soon as DTR is asserted. p. 17
- Wait until power dissipates from the SLC 500 power supply, about 10 seconds, before installing or removing the module. p. 24
- The DH-485 port is not isolated. p. 118
- For RS-232 communication, use the RS-423 jumper settings. p. 119
- A capacitor keeps RAM data for 30 minutes while the battery is disconnected. p. 126
Questions this manual answers
Does the 1747-KE need a 1747-AIC link coupler?
Yes, to join a DH-485 network with multiple SLC 500 processors. A 1747-C13 cable can connect it directly to a single SLC processor. p. 14
What battery does the 1747-KE use?
A replaceable 1747-BA lithium battery, which backs up RAM for about five years. p. 125
What does the BA LOW LED on the 1747-KE mean?
The battery that backs up configuration RAM is low and needs replacing. p. 15
What does SLC fault code xx55 mean for the 1747-KE?
A wrong ID code or wrong input and output sizes were entered; xx is the module's slot. p. 87
How far can the 1747-KE communicate over RS-232?
15 m (50 ft) at every listed rate. p. 119
Contents
Chapters and sections
Each line opens the PDF at its page.
- 1747-UM005B-EN-P, DH-485/RS-232C Interface Module User Manual1
- Summary of Changes3
- Preface9
- 1 - Overview13
- 2 - Quick Start23
- 3 - Communicate with the Interface Module27
- 4 - Installation and System Configuration39
- Installation and System Configuration39
- European Union Directives Compliance39
- Choose the Module’s Functionality40
- Set the Module’s Mode42
- Verify CONFIG Port Configuration43
- Verify DF1 Port Configuration44
- Install Your Module in an Open Slot45
- Connect Cable to CONFIG or DF1 Ports46
- Connect Cable to the DH-485 Port49
- Configure Your SLC Chassis51
- Configure the DF1 Driver within RSLinx Software52
- Configure Your Module53
- Complete the Installation of Your Module53
- 5 - Module Configuration with a Terminal Overview55
56 more lines, from page 55 on
- Module Configuration Using an ASCII Terminal55
- 6 - Module Configuration Using the Backplane67
- Module Configuration Using the Backplane67
- Overview67
- Configure the Interface Module from the SLC Processor68
- Place the Module into Software Run Mode from SLC Processor70
- Read the Module’s Configuration from the SLC Processor71
- Examine the SLC Processor’s Status Word72
- Build the DF1 Configuration Packet74
- Build the DH-485 Configuration Packet78
- Build the Modem Init String Configuration Packets79
- Use the Real Time Clock82
- Establish a Data Echo Between the Interface Module and the SLC Processor83
- Reset the Interface Module from the SLC Processor84
- 7 - Interpret the LED Indicators85
- 8 - Application Examples89
- A - Specifications117
- B - PLC-5 to SLC 500 Communications121
- C - Lithium Battery Replacement, Handling, and Disposal125
- D - Interface Module Configuration Worksheets131
- Index135
- Back Cover139
The whole text · 20 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Table of Contents5-8
- Preface9-12
- 1 - Overview13-22
- 2 - Quick Start23-26
- 3 - Communicate with the Interface Module27-38
- 4 - Installation and System Configuration, pages 39 to 4639-46
- 4 - Installation and System Configuration, pages 47 to 5447-54
- 5 - Module Configuration with a Terminal Overview55-66
- 6 - Module Configuration Using the Backplane, pages 67 to 7567-75
- 6 - Module Configuration Using the Backplane, pages 76 to 8476-84
- 7 - Interpret the LED Indicators85-88
- 8 - Application Examples, pages 89 to 9889-98
- 8 - Application Examples, pages 99 to 10899-108
- 8 - Application Examples, pages 109 to 116109-116
- A - Specifications117-120
- B - PLC-5 to SLC 500 Communications121-124
- C - Lithium Battery Replacement, Handling, and Disposal125-130
- D - Interface Module Configuration Worksheets131-134
- Pages 135 to 139135-139