Page 37
Chapter
2
The Menu Tree This chapter guides you through the HHT display menu tree. It is intended as an overview. For a more detailed introduction to ladder programming, refer to The Getting Started Guide for HHT, catalog number 1747–NM009. The abbreviated function and instruction mnemonic keys you encounter in this manual and on the HHT displays are explained at the end of this chapter.
Using the HHT Menu
Before you begin using the HHT to develop a user program or communicate online, you should be familiar with the following:
Progressing through Menu Displays To progress through the HHT menu displays, press the desired function key. When that display appears, press the next appropriate function key, and so on. 1. For example, to clear the HHT memory, start from the Main menu. SLC 500 PROGRAMMING SOFTWARE Rel. 2.03 1747 – PTA1E Allen–Bradley Company Copyright 1990 All Rights Reserved PRESS A FUNCTION KEY SELFTEST TERM PROGMAINT F1
F2
F3
OFL UTILITY F4
F5
2. Press [F3], PROGMAINT. The following menu is displayed: File Name: 101 File Name 0 1 2 101
Prog Name: 1492 Type Size(Instr) System 217 Reserved 0 Ladder 465
OFL CHG_NAM CRT_FIL EDT_FIL DEL_FIL MEM_MAP > F1
F2
F3
F4
F5
2–1
Page 38
Chapter 2 The Menu Tree
The ENTER Key 1. Because the > symbol appears in the lower right hand corner of the display, press [ENTER] to display additional menu functions. File Name: 101 File Name 0 1 2 101
Prog Name: 1492 Type Size(Instr) System 217 Reserved 0 Ladder 465 OFL
EDT_DAT SEL_PRO EDT_I/O CLR_MEM F1
F2
F3
F4
> F5
2. Press [F4], CLR_MEM to clear the HHT memory. You are asked to confirm: File Name: 101 File Name 0 1 2 101
Prog Name: 1492 Type Size(Instr) System 217 Reserved 0 Ladder 465
ARE YOU SURE? YES F1
F2
OFL NO F3
F4
> F5
3. Press [F2], YES. This deletes the current program in the HHT. After you confirm, the display returns to the previous menu. File Name: File Name 0 1 2
Prog Name: Default Type Size(Instr) System Reserved Ladder OFL
EDT_DAT SEL_PRO EDT_I/O CLR_MEM F1
F2
F3
F4
> F5
The ESCAPE Key Use [ESC] to exit a menu and move to the previous one. 1. Press [ESC] to return to the Main menu. SLC 500 PROGRAMMING SOFTWARE Rel. 2.03 1747 – PTA1E Allen–Bradley Company Copyright 1990 All Rights Reserved PRESS A FUNCTION KEY SELFTEST TERM PROGMAINT F1
2–2
F2
F3
OFL UTILITY F4
F5
Page 39
Chapter 2 The Menu Tree
The Main Menu
After going through diagnostic tests at startup/powerup, the HHT displays the Main menu. It consists of the following function keys: • Selftest • Terminal • Program Maintenance • Utility The display appears as follows: SLC 500 PROGRAMMING SOFTWARE Rel. 2.03 1747 – PTA1E Allen–Bradley Company Copyright 1990 All Rights Reserved PRESS A FUNCTION KEY SELFTEST TERM PROGMAINT F1
Main Menu Functions
F2
F3
OFL UTILITY F4
F5
Some of the procedures you may perform from the Main menu are: SELFTEST, [F1] Allows you to test the following components of the HHT: • display • keypad • random access memory • read only memory • internal watchdog timer TERMINAL, [F2] Allows you to: • configure the HHT for IMC 110 mode (when attached to a 1746–HS module) • monitor and debug MML programs PROGRAM MAINTENANCE, [F3] Allows you to: • name programs and program files • create, delete, and edit program files • create and delete data files • edit data files • select processors and configure the I/O • clear HHT memory
2–3
Page 40
Chapter 2 The Menu Tree
UTILITY, [F5] Allows you to: • attach online to a processor – upload and download programs between the processor and HHT – change processor mode – transfer processor memory between RAM and EEPROM – force inputs and outputs • access network diagnostic functions • create or delete processor passwords • clear processor memory • monitor the ladder diagram while the processor is in Run mode
The Menu Tree
The figures that follow, graphically guide you through the HHT menus and sub–menus. Main Menu F1
SELFTEST
F1
DISPLAY
F2
KEYPAD
F3
RAM
F2
DSTRUCT
F4
ROM
F4
NONDEST
F5
WTCHDOG
F2
TERM
F3
PROGMAINT
Refer to page 2–6.
F5
UTILITY
Refer to page 2–7 to 2–10.
Main Menu Function Key
2–4
Use For
SELFTEST
HHT unit diagnostics
TERM terminal mode for IMC 110
PROGMAINT program development and editing
UTILITY processor/network communications and online monitoring
Page 41
Chapter 2 The Menu Tree
Main Menu – Program Maintenance [F3] F3
PROGMAINT
F1
CHG_NAM
F2
PROGRAM
F2
CRT_FIL
F4
FILE
F3
EDT_FIL
F1
INS_RNG_
F2
MOD_RNG
F3
SEARCH
F1
CUR–INS
F4
DEL_RNG
F2
CUR–OPD
F5
UND_RNG
F1
INS_INST
F2
BRANCH
F3
NEW–INS
F4
UP
F3
MOD_INST
F5
FORCE
F5
ACP_RNG
See next page. F1
EXT_UP
F2
EXT_DWN
F3
APP_BR
F4
INS_BR
F5
DEL_BR
ENTER F1
EDT_DAT
F1
ADDRESS
F4
SAVE_CT
F2
NEXT_FL
ENTER F4
DEL_FIL
F5
SAVE_EX
F3
PREV_FL
F2
DEL_INST
F5
MEM_MAP
F1
CRT_DT
F4
NEXT_PG
F4
UND_INST
F2
DEL_DT
F5
PREV_PG
F3
NEXT_PG
F4
PREV_PG
F5
PRG_SIZE
F1
ADDRESS
F2
NEXT_FL
F3
PREV_FL
F4
NEXT_PG
F5
PREV_PG
F1
TYPE
F3
SERIES
F1
MOD_RCK
F1
RACK 1
F2
RACK 2
F3
RACK 3
F3
OTHER
F1
INT_SBR
F2
MOD_SET
ENTER
F1
F2
F3
F4
EDT_DAT
SEL_PRO
EDT_I/O
F2
MOD_SLT
F3
DEL_SLT
F4
UND_SLT
F5
ADV_SET
F3
CFG_SIZ
F4
ADV_SIZ
Legend
F1
BIN
F2
DEC
F3
HEX/BCD
SLC 5/02 only
F4
NEXT_PG
• Toggle operation
F5
PREV_PG
Modular controllers only
Enter file number have to select * May node first
CLR_MEM
2–5
Page 42
Chapter 2 The Menu Tree
Program Maintenance [F3] – Ladder Editing
See previous page.
F1
BIT
F2
TMR/CNT
F3
I/O_MSG
F4
COMPARE
F1
–] [–
F1
TON
F2
–] / [–
F1
IIM
F2
TOF
F3
–( )–
F1
LIM
F2
IOM
F3
RTO
F4
–( L )–
F3
MEQ
F3
MSG
F4
CTU
F5
–( U )–
F4
EQU
F4
IIE
F5
CTD
F5
NEQ
F5
IID F1
OSR
F5
OTHERS
ENTER ENTER ENTER
F5
ENTER F1
RES
F1
LES
F1
RPI
F2
HSC
F2
GRT
F3
REF
F5
OTHERS
F3
LEQ
F4
SVC
F4
GEQ
F5
OTHERS
F5
OTHERS
CPT/MTH
ENTER
F1
ADD
F2
SUB
F3
MUL
F4
DIV
F5
DDV
ENTER F1
MOV/LOG
F2
FILE
F3
SFT/SEQ
F4
CONTROL
F1
BSL
F1
MOV
F1
COP
F2
MVM
F1
NEG
F2
FLL
F3
AND
F2
CLR
F1
JMP
F2
BSR
F4
OR
F3
SQR
F2
LBL
F3
SQC
F5
XOR
F4
TOD
F3
JSR
F4
SQL
F5
FRD
F4
RET
F5
SQO
F5
MCR F2
DCD
F3
SCL
F4
PID
F5
OTHERS
ENTER
ENTER F1
SBR
F2
INT
F3
STE
F4
STS
F5
STD
ENTER
2–6
F3
SUS
F4
TND
F5
OTHERS
ENTER
ENTER F1
FFL
F2
FFU
F3
LFL
F4
LFU
F5
OTHERS
F5
OTHERS
F1
NOT
F5
OTHERS
Page 43
Chapter 2 The Menu Tree
Main Menu – Utility [F5], Default Program in Processor (First Time) F5
UTILITY
F1
ONLINE
F1
F3
F4
F5
F2
WHO
F3
PASSWRD
F5
DIAGNSTC
*
ATTACH
NODE_CFG
OWNER
F1
ENT
F2
REM
F3
ENT_MAS
F4
REM_MAS
F1
NODE
F5
NETWORK
F1
OFFLINE
F2
DWNLOAD
F3
CLR_PRC
F4
MEM_PRC
F1
CHG_ADR
F2
MAX_ADR
F3 F1 F5
F5
RESET
BAUD
F1
19200
SET_OWNR
F2
9600
CLR_OWNR
F3
2400
F4
1200
CLR_MEM
Main Menu – Utility [F5], Default Program in Processor (If Previously Attached to that Processor) F5
UTILITY
F1
F2
ONLINE
WHO
F1
OFFLINE
F2
DWNLOAD
F3
CLR_PRC
F4
MEM_PRC
F1
DIAGNSTC
F3
ATTACH
F4
F3
F5
PASSWRD
*
NODE_CFG
F2
OWNER
F1
ENT
F2
REM
F3
ENT_MAS
F4
REM_MAS
F1
NODE
F5
NETWORK
F1
OFFLINE
F2
DWNLOAD
F3
CLR_PRC
F4
MEM_PRC
F1
CHG_ADR
F2
MAX_ADR
F3
F5
RESET
BAUD
F1
19200
F1
SET_OWNR
F2
9600
F5
CLR_OWNR
F3
2400
F4
1200
Legend Modular controllers only SLC 5/02 only
• Toggle operation Enter file number have to select * May node first
CLR_MEM
2–7
Page 44
Chapter 2 The Menu Tree
Main Menu – Utility [F5], Processor Program Does Not Equal HHT Program (First Time) F5
UTILITY
F1
ONLINE
F1
DIAGNSTC
* F3 ATTACH
F4
F5 F2
WHO
F3
PASSWRD
F5
NODE_CFG
OWNER
F1
ENT
F2
REM
F3
ENT_MAS
F4
REM_MAS
F1
NODE
F5
NETWORK
F1
OFFLINE
F2
UPLOAD
F3
DWNLOAD
F4 F5
F5
RESET
MODE
F1
RUN
CLR_PRC
F3
TEST
F2
CONT
F1
CHG_ADR
F5
PROGRAM
F4
SINGLE
F2
MAX_ADR
F3
BAUD
F1
SET_OWNR
F5
CLR_OWNR
F1
19200
F2
9600
F3
2400
F4
1200
CLR_MEM
Main Menu – Utility [F5], Processor Program Does Not Equal HHT Program (If Previously Attached to that Processor) F5
UTILITY
F1
F2
ONLINE
WHO
F1
OFFLINE
F2
UPLOAD
F3
DWNLOAD
F4
MODE
F1
RUN
F5
CLR_PRC
F3
TEST
• •
F2
CONT
F5
PROGRAM
•
F4
SINGLE
F1
DIAGNSTC
F1
NODE
F5
NETWORK
F5
RESET
F3
ATTACH
F1
OFFLINE
F2
UPLOAD
F3
DWNLOAD
F4
MODE
F1
RUN
F5
CLR_PRC
F3
TEST
F2
CONT
F1
CHG_ADR
F5
PROGRAM
F4
SINGLE
F2
MAX_ADR
F4
F3
F5
2–8
PASSWRD
CLR_MEM
*
NODE_CFG
F3
BAUD
F5
OWNER
F1
SET_OWNR
F1
ENT
F5
CLR_OWNR
F2
REM
F3
ENT_MAS
F4
REM_MAS
F1
19200
F2
9600
F3
2400
F4
1200