Page 37

Chapter

2

The Menu Tree This chapter guides you through the HHT display menu tree. It is intended as an overview. For a more detailed introduction to ladder programming, refer to The Getting Started Guide for HHT, catalog number 1747–NM009. The abbreviated function and instruction mnemonic keys you encounter in this manual and on the HHT displays are explained at the end of this chapter.

Using the HHT Menu

Before you begin using the HHT to develop a user program or communicate online, you should be familiar with the following:

Progressing through Menu Displays To progress through the HHT menu displays, press the desired function key. When that display appears, press the next appropriate function key, and so on. 1. For example, to clear the HHT memory, start from the Main menu. SLC 500 PROGRAMMING SOFTWARE Rel. 2.03 1747 – PTA1E Allen–Bradley Company Copyright 1990 All Rights Reserved PRESS A FUNCTION KEY SELFTEST TERM PROGMAINT F1

F2

F3

OFL UTILITY F4

F5

2. Press [F3], PROGMAINT. The following menu is displayed: File Name: 101 File Name 0 1 2 101

Prog Name: 1492 Type Size(Instr) System 217 Reserved 0 Ladder 465

OFL CHG_NAM CRT_FIL EDT_FIL DEL_FIL MEM_MAP > F1

F2

F3

F4

F5

2–1

Page 38

Chapter 2 The Menu Tree

The ENTER Key 1. Because the > symbol appears in the lower right hand corner of the display, press [ENTER] to display additional menu functions. File Name: 101 File Name 0 1 2 101

Prog Name: 1492 Type Size(Instr) System 217 Reserved 0 Ladder 465 OFL

EDT_DAT SEL_PRO EDT_I/O CLR_MEM F1

F2

F3

F4

> F5

2. Press [F4], CLR_MEM to clear the HHT memory. You are asked to confirm: File Name: 101 File Name 0 1 2 101

Prog Name: 1492 Type Size(Instr) System 217 Reserved 0 Ladder 465

ARE YOU SURE? YES F1

F2

OFL NO F3

F4

> F5

3. Press [F2], YES. This deletes the current program in the HHT. After you confirm, the display returns to the previous menu. File Name: File Name 0 1 2

Prog Name: Default Type Size(Instr) System Reserved Ladder OFL

EDT_DAT SEL_PRO EDT_I/O CLR_MEM F1

F2

F3

F4

> F5

The ESCAPE Key Use [ESC] to exit a menu and move to the previous one. 1. Press [ESC] to return to the Main menu. SLC 500 PROGRAMMING SOFTWARE Rel. 2.03 1747 – PTA1E Allen–Bradley Company Copyright 1990 All Rights Reserved PRESS A FUNCTION KEY SELFTEST TERM PROGMAINT F1

2–2

F2

F3

OFL UTILITY F4

F5

Page 39

Chapter 2 The Menu Tree

The Main Menu

After going through diagnostic tests at startup/powerup, the HHT displays the Main menu. It consists of the following function keys: • Selftest • Terminal • Program Maintenance • Utility The display appears as follows: SLC 500 PROGRAMMING SOFTWARE Rel. 2.03 1747 – PTA1E Allen–Bradley Company Copyright 1990 All Rights Reserved PRESS A FUNCTION KEY SELFTEST TERM PROGMAINT F1

Main Menu Functions

F2

F3

OFL UTILITY F4

F5

Some of the procedures you may perform from the Main menu are: SELFTEST, [F1] Allows you to test the following components of the HHT: • display • keypad • random access memory • read only memory • internal watchdog timer TERMINAL, [F2] Allows you to: • configure the HHT for IMC 110 mode (when attached to a 1746–HS module) • monitor and debug MML programs PROGRAM MAINTENANCE, [F3] Allows you to: • name programs and program files • create, delete, and edit program files • create and delete data files • edit data files • select processors and configure the I/O • clear HHT memory

2–3

Page 40

Chapter 2 The Menu Tree

UTILITY, [F5] Allows you to: • attach online to a processor – upload and download programs between the processor and HHT – change processor mode – transfer processor memory between RAM and EEPROM – force inputs and outputs • access network diagnostic functions • create or delete processor passwords • clear processor memory • monitor the ladder diagram while the processor is in Run mode

The Menu Tree

The figures that follow, graphically guide you through the HHT menus and sub–menus. Main Menu F1

SELFTEST

F1

DISPLAY

F2

KEYPAD

F3

RAM

F2

DSTRUCT

F4

ROM

F4

NONDEST

F5

WTCHDOG

F2

TERM

F3

PROGMAINT

Refer to page 2–6.

F5

UTILITY

Refer to page 2–7 to 2–10.

Main Menu Function Key

2–4

Use For

SELFTEST

HHT unit diagnostics

TERM terminal mode for IMC 110

PROGMAINT program development and editing

UTILITY processor/network communications and online monitoring

Page 41

Chapter 2 The Menu Tree

Main Menu – Program Maintenance [F3] F3

PROGMAINT

F1

CHG_NAM

F2

PROGRAM

F2

CRT_FIL

F4

FILE

F3

EDT_FIL

F1

INS_RNG_

F2

MOD_RNG

F3

SEARCH

F1

CUR–INS

F4

DEL_RNG

F2

CUR–OPD

F5

UND_RNG

F1

INS_INST

F2

BRANCH

F3

NEW–INS

F4

UP

F3

MOD_INST

F5

FORCE

F5

ACP_RNG

See next page. F1

EXT_UP

F2

EXT_DWN

F3

APP_BR

F4

INS_BR

F5

DEL_BR

ENTER F1

EDT_DAT

F1

ADDRESS

F4

SAVE_CT

F2

NEXT_FL

ENTER F4

DEL_FIL

F5

SAVE_EX

F3

PREV_FL

F2

DEL_INST

F5

MEM_MAP

F1

CRT_DT

F4

NEXT_PG

F4

UND_INST

F2

DEL_DT

F5

PREV_PG

F3

NEXT_PG

F4

PREV_PG

F5

PRG_SIZE

F1

ADDRESS

F2

NEXT_FL

F3

PREV_FL

F4

NEXT_PG

F5

PREV_PG

F1

TYPE

F3

SERIES

F1

MOD_RCK

F1

RACK 1

F2

RACK 2

F3

RACK 3

F3

OTHER

F1

INT_SBR

F2

MOD_SET

ENTER

F1

F2

F3

F4

EDT_DAT

SEL_PRO

EDT_I/O

F2

MOD_SLT

F3

DEL_SLT

F4

UND_SLT

F5

ADV_SET

F3

CFG_SIZ

F4

ADV_SIZ

Legend

F1

BIN

F2

DEC

F3

HEX/BCD

SLC 5/02 only

F4

NEXT_PG

• Toggle operation

F5

PREV_PG

Modular controllers only

Enter file number have to select * May node first

CLR_MEM

2–5

Page 42

Chapter 2 The Menu Tree

Program Maintenance [F3] – Ladder Editing

See previous page.

F1

BIT

F2

TMR/CNT

F3

I/O_MSG

F4

COMPARE

F1

–] [–

F1

TON

F2

–] / [–

F1

IIM

F2

TOF

F3

–( )–

F1

LIM

F2

IOM

F3

RTO

F4

–( L )–

F3

MEQ

F3

MSG

F4

CTU

F5

–( U )–

F4

EQU

F4

IIE

F5

CTD

F5

NEQ

F5

IID F1

OSR

F5

OTHERS

ENTER ENTER ENTER

F5

ENTER F1

RES

F1

LES

F1

RPI

F2

HSC

F2

GRT

F3

REF

F5

OTHERS

F3

LEQ

F4

SVC

F4

GEQ

F5

OTHERS

F5

OTHERS

CPT/MTH

ENTER

F1

ADD

F2

SUB

F3

MUL

F4

DIV

F5

DDV

ENTER F1

MOV/LOG

F2

FILE

F3

SFT/SEQ

F4

CONTROL

F1

BSL

F1

MOV

F1

COP

F2

MVM

F1

NEG

F2

FLL

F3

AND

F2

CLR

F1

JMP

F2

BSR

F4

OR

F3

SQR

F2

LBL

F3

SQC

F5

XOR

F4

TOD

F3

JSR

F4

SQL

F5

FRD

F4

RET

F5

SQO

F5

MCR F2

DCD

F3

SCL

F4

PID

F5

OTHERS

ENTER

ENTER F1

SBR

F2

INT

F3

STE

F4

STS

F5

STD

ENTER

2–6

F3

SUS

F4

TND

F5

OTHERS

ENTER

ENTER F1

FFL

F2

FFU

F3

LFL

F4

LFU

F5

OTHERS

F5

OTHERS

F1

NOT

F5

OTHERS

Page 43

Chapter 2 The Menu Tree

Main Menu – Utility [F5], Default Program in Processor (First Time) F5

UTILITY

F1

ONLINE

F1

F3

F4

F5

F2

WHO

F3

PASSWRD

F5

DIAGNSTC

*

ATTACH

NODE_CFG

OWNER

F1

ENT

F2

REM

F3

ENT_MAS

F4

REM_MAS

F1

NODE

F5

NETWORK

F1

OFFLINE

F2

DWNLOAD

F3

CLR_PRC

F4

MEM_PRC

F1

CHG_ADR

F2

MAX_ADR

F3 F1 F5

F5

RESET

BAUD

F1

19200

SET_OWNR

F2

9600

CLR_OWNR

F3

2400

F4

1200

CLR_MEM

Main Menu – Utility [F5], Default Program in Processor (If Previously Attached to that Processor) F5

UTILITY

F1

F2

ONLINE

WHO

F1

OFFLINE

F2

DWNLOAD

F3

CLR_PRC

F4

MEM_PRC

F1

DIAGNSTC

F3

ATTACH

F4

F3

F5

PASSWRD

*

NODE_CFG

F2

OWNER

F1

ENT

F2

REM

F3

ENT_MAS

F4

REM_MAS

F1

NODE

F5

NETWORK

F1

OFFLINE

F2

DWNLOAD

F3

CLR_PRC

F4

MEM_PRC

F1

CHG_ADR

F2

MAX_ADR

F3

F5

RESET

BAUD

F1

19200

F1

SET_OWNR

F2

9600

F5

CLR_OWNR

F3

2400

F4

1200

Legend Modular controllers only SLC 5/02 only

• Toggle operation Enter file number have to select * May node first

CLR_MEM

2–7

Page 44

Chapter 2 The Menu Tree

Main Menu – Utility [F5], Processor Program Does Not Equal HHT Program (First Time) F5

UTILITY

F1

ONLINE

F1

DIAGNSTC

* F3 ATTACH

F4

F5 F2

WHO

F3

PASSWRD

F5

NODE_CFG

OWNER

F1

ENT

F2

REM

F3

ENT_MAS

F4

REM_MAS

F1

NODE

F5

NETWORK

F1

OFFLINE

F2

UPLOAD

F3

DWNLOAD

F4 F5

F5

RESET

MODE

F1

RUN

CLR_PRC

F3

TEST

F2

CONT

F1

CHG_ADR

F5

PROGRAM

F4

SINGLE

F2

MAX_ADR

F3

BAUD

F1

SET_OWNR

F5

CLR_OWNR

F1

19200

F2

9600

F3

2400

F4

1200

CLR_MEM

Main Menu – Utility [F5], Processor Program Does Not Equal HHT Program (If Previously Attached to that Processor) F5

UTILITY

F1

F2

ONLINE

WHO

F1

OFFLINE

F2

UPLOAD

F3

DWNLOAD

F4

MODE

F1

RUN

F5

CLR_PRC

F3

TEST

• •

F2

CONT

F5

PROGRAM

•

F4

SINGLE

F1

DIAGNSTC

F1

NODE

F5

NETWORK

F5

RESET

F3

ATTACH

F1

OFFLINE

F2

UPLOAD

F3

DWNLOAD

F4

MODE

F1

RUN

F5

CLR_PRC

F3

TEST

F2

CONT

F1

CHG_ADR

F5

PROGRAM

F4

SINGLE

F2

MAX_ADR

F4

F3

F5

2–8

PASSWRD

CLR_MEM

*

NODE_CFG

F3

BAUD

F5

OWNER

F1

SET_OWNR

F1

ENT

F5

CLR_OWNR

F2

REM

F3

ENT_MAS

F4

REM_MAS

F1

19200

F2

9600

F3

2400

F4

1200