1756-DNB Status Structure

Module Status Structure

The controller receives status information concerning the 1756-DNB module’s ability to exchange DeviceNet messages with other nodes by reading from a Status Structure in the 1756-DNB module. The module periodically updates the contents of the Status Structure and copies its contents to the controller. The Status Structure consists of several 64-bit tables. The bit position of each of the 64 bits that make up a given status table directly corresponds to the node address of a device. The Status Structure can be seen in the Controller Tags database by expanding the Status tag (i.e., Local:1:S).

1

Publication 1756-6.5.19 - May 2000

Page 88

A-2

1756-DNB Status Structure

The Status Structure consists of these data regions: Status Structure

Element Description

Data Type

Scan_Counter counter incremented each I/O scan

32-bit

Device_Failure_Register device failed bit table; 1 = failed

64-bit

Autoverify_Failure_Register device I/O size does not match scanner’s internal table; 1 = mismatch

64-bit

Device_Idle_Register device is idle bit table; 1 = idle

64-bit

Active_Node_Register

Node online table; 1 = online

64-bit

Status_Display

ASCII representation of DNB alphanumeric display

4-byte

Scanner_Device_Status

Scanner Device Status:

4-byte BCD scanner_address

DeviceNet address of DNB module

8-bit BCD scanner_status

Status of DNB module

8-bit BCD device_address

Scrolls through faulted DeviceNet nodes by address (0 = no faults)

8-bit BCD device_status

DINTs 10

11

8-bit BCD

Reserved_Array

Future Expansion (20 bytes)

20 8-bit

16

Device_Status_Array

DeviceNet node status, 1 byte per device

64 8-bit

24/32

The 1756-DNB, versions 3.002 and higher, and RSLogix 5000, versions 2.25 and higher, support variable size Status Structures. When the user specifies the size of the Status Structure during the 1756-DNB Module Properties configuration (see page 6-6), the elements of the structure correspond the definition of the Status Structure up to the size selected.

Publication 1756-6.5.19 - May 2000

Page 89

1756-DNB Status Structure

A-3

For ControlLogix, the available sizes are: • 10 DINTs (32-bit value) • 11 DINTs • 16 DINTs • 24 DINTs • 32 DINTs (Default) For example, if the user selects a status size of 10 DINTs in RSLogix 5000, the Status Structure would consist of fields Scan-Counter through Reserved_Array. If the user selects a status size of 24, the Status Structure would consist of fields Scan_Counter through half of the Device_Status_Array (first 32 DeviceNet addresses). If the user selects a Status Size of 32, the Status Structure would consist of fields Scan_Counter through the entire Device_Status_Array.