Page 41

1756 ControlLogix I/O Specifications

1756-IF6CIS ControlLogix sourcing current loop analog input module 1756-IF6CIS 2-wire Transmitter Connected to the Module and the Module Providing 24V DC Loop Power 1

2

VOUT-1

A

3

IN-0/I

IN-1/I 6

5

RTN-1

RTN-0 8

7

10

9

IN-3/I i

12

Shield Ground

13

16

15

18

17

IN-5/I 20

5

8

7

10

9

12

11

14

13

16

15

18

17

20

19

RTN-0

19

IN-3/I

RTN-5

RTN-4

A

24V DC – +

2-wire Transmitter

VOUT-2 IN-2/I Shield Ground

RTN-2 Not Used VOUT-4

IN-5/I

IN-4/I

RTN-5

6

VOUT-5

VOUT-4

A

IN-0/I

Not Used

Not Used

VOUT-5

VOUT-0 i

RTN-3

RTN-2 14

3

VOUT-3

11

Not Used

4

RTN-1

IN-2/I

RTN-3

1

IN-1/I

A

VOUT-2

VOUT-3

2

VOUT-1

VOUT-0 4

1756-IF6CIS 2-wire Transmitter Connected to the Module and an External, User-provided Power Supply Providing 24V DC Loop Power

IN-4/I RTN-4

Place additional loop devices (such as strip chart recorders) at either A location in the current loop. 1756-IF6CIS 4-wire Transmitter Connected to the Module and an External, Userprovided Power Supply Providing 24V DC Loop Power 2

1

4

3

VOUT-0

VOUT-1

A

+

A

4-wire Transmitter –

IN-0/I

IN-1/I 6

5

8

7

10

9

12

11

RTN-0

RTN-1

+ ANALOG INPUT

24V DC –

CAL

VOUT-2

VOUT-3

OK

IN-2/I

IN-3/I

RTN-2

RTN-3 14

13

16

15

18

17

20

19

Shield Ground

Not Used

Not Used

VOUT-4

VOUT-5

IN-4/I

IN-5/I RTN-5 i

RTN-4

• Place additional loop devices (such as strip chart recorders) at either A location in the current loop. • User-supplied power supply must not exceed 150VA.

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

41

Page 42

1756 ControlLogix I/O Specifications

Signal and User Counts - 1756-IF6CIS Range

Low Signal and User Counts

High Signal and User Counts

0…20 mA

0 mA -32768 counts

21.09376 mA 32767 counts

Technical Specifications - 1756-IF6CIS Attribute

1756-IF6CIS

Inputs

6 individually isolated current sourcing

Input range

0…20 mA (overrange indication when exceeded)

Resolution

16 bits 0.34 A/bit

Current draw @ 5.1V

250 mA

Current draw @ 24V

275 mA

Total backplane power

7.9 W

Power dissipation, max

5.1 W @ 60 °C (140 °F)

Thermal dissipation

17.4 BTU/hr

Input impedance

215 , approx

Sourcing voltage, min

20V DC

Sourcing voltage, max

30V DC

Sourcing current, max

Current limited to < 30 mA

Open circuit detection time

Zero reading within 5 s

Overvoltage protection, max

30V AC/DC with PTC and sense resistor

Normal mode noise rejection

60 dB @ 60 Hz(1)

Common mode noise rejection

120 dB @ 60 Hz 100 dB @ 50 Hz

Channel bandwidth

3…262 Hz (-3 dB)(1)

Settling time

<80 ms to 5% of full scale(1)

Calibrated accuracy 25 °C (77 °F), nom

Better than 0.1% of range

Calibrated accuracy 25 °C (77 °F), max

0.025% of range

Calibration interval

12 months

Offset drift

200 nA/°C

Gain drift with temperature, nom

17 ppm/°C 0.36 A/°C

Gain drift with temperature, max

35 ppm/°C max 0.74 A/°C max

Module error

0.2% of range

Module input scan time, min

25 ms min – floating point 10 ms min – integer

Onboard data alarming

Yes

Scaling to engineering units

Yes

Real-time channel sampling

Yes

Data format

Integer mode (left justified, 2 s complement) IEEE 32-bit floating point

Module conversion method

Sigma-Delta

42

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

Page 43

1756 ControlLogix I/O Specifications

Technical Specifications - 1756-IF6CIS (continued) Attribute

1756-IF6CIS

Isolation voltage

250V (continuous), basic insulation type, input channels-to-backplane, and input channel-to-channel Routine tested at 1350V AC for 2 s

Module keying

Electronic, software configurable

Removable terminal block

1756-TBNH 1756-TBSH

RTB keying

User-defined mechanical

Slot width

1

Wire category

2(2)

North American temperature code

T4A

IEC temperature code

T4

Enclosure type

None (open-style)

(1) Notch filter dependent. (2) Use this conductor category information for planning conductor routing as described in the system-level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.

Environmental Specifications - 1756-IF6CIS Attribute

1756-IF6CIS

Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

0…60 °C (32…140 °F)

Temperature, surrounding air, max

60 °C (140 °F)

Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…+85 °C (-40…+185 °F)

Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)

5…95% noncondensing

Vibration IEC 60068-2-6 (Test Fc, Operating)

2 g @ 10…500 Hz

Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

30 g

Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

50 g

Emissions

CISPR 11, Class A

ESD immunity IEC 61000-4-2

6 kV contact discharges 8 kV air discharges

Radiated RF immunity IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

EFT/B immunity IEC 61000-4-4

±2 kV at 5 kHz on shielded signal ports

Surge transient immunity IEC 61000-4-5

±2 kV line-earth (CM) on shielded signal ports

Conducted RF immunity IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz on shielded signal ports

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

43

Page 44

1756 ControlLogix I/O Specifications

Certifications - 1756-IF6CIS Certification(1)

1756-IF6CIS

UL

UL Listed Industrial Control Equipment. See UL File E65584.

CSA

CSA Certified Process Control Equipment. See CSA File LR54689C. CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File LR69960C.

CE

European Union 2004/108/IEC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11)

C-Tick

Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions

Ex

European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • EN 60079-0; General Requirements II 3 G Ex nA IIC T4 X Gc

FM

FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations

KC

Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3

(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

44

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

Page 45

1756 ControlLogix I/O Specifications

1756-IF6I ControlLogix isolated voltage/current analog input module 1756-IF6I Current 4-wire

1756-IF6I Current 2-wire 1

2

IN-1/V 3

4

IN-1/I

IN-0/I 6

5

8

7

RET-1 i A

2-wire Transmitter

13

RET-2 Not Used 16

IN-5/V

IN-4/V 17

20

19

8

7

10

9

12

11

IN-5/I RET-5

4-wire Transmitter

–

IN-2/I Shield Ground

RET-2 14

13

16

15

18

17

20

19

Not Used IN-4/V IN-4/I

IN-5/I

IN-4/I

A i

IN-2/V

IN-5/V

15

18

RET-0

Not Used

Not Used

A

5

RET-3

RET-3

+ IN-0/I

IN-3/I

IN-2/I

14

IN-0/V

IN-3/V

9

11

3

6

A

IN-3/I 12

4

RET-1

IN-2/V 10

1

IN-1/I

RET-0

IN-3/V

2

IN-1/V

+

–

IN-0/V

RET-5

RET-4

RET-4

Place additional loop devices (such as strip chart recorders) at either A location.

1756-IF6I Voltage Voltage Input 2

1

IN-1/V

IN-0/V 4

IN-1/I

User Analog Input Device

IN-0/I 6

5

8

7

RET-1

RET-0

IN-3/V

– Device External Power

IN-2/V 10

9

12

11

IN-3/I

IN-2/I

RET-3 13

16

15

18

17

ANALOG INPUT CAL OK

RET-2 14

Not Used

Not Used

IN-5/V

IN-4/V

IN-5/I

IN-4/I 20

RET-5

+

3

Shield Ground

19

RET-4

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

45

Page 46

1756 ControlLogix I/O Specifications

Signal and User Counts - 1756-IF6I Range

Low Signal and User Counts

High Signal and User Counts

±10V

-10.54688V -32768 counts

10.54688V 32767 counts

0…10V

0V -32768 counts

10.54688V 32767 counts

0…5V

0V -32768 counts

5.27344V 32767 counts

0…20 mA

0 mA -32768 counts

21.09376V 32767 counts

Technical Specifications - 1756-IF6I Attribute

1756-IF6I

Inputs

6 individually isolated

Input range

±10.5V 0…10.5V 0…5.25V 0…21 mA (Overrange indication when exceeded)

Resolution

16 bits 10.5V: 343 V/bit 0…10.5V: 171 V/bit 0…5.25V: 86 V/bit 0…21 mA: 0.34 A/bit

Current draw @ 5.1V

250 mA

Current draw @ 24V

100 mA

Total backplane power

3.7 W

Power dissipation, max

Voltage: 3.7 W Current: 4.3 W

Thermal dissipation

Voltage: 12.62 BTU/hr Current: 14.32 BTU/hr

Input impedance

Voltage: > 10 M Current: 249

Open circuit detection time

Positive full scale reading within 5 s

Overvoltage protection, max

Voltage: 120V AC/DC Current: 8V AC/DC (with onboard current resistor)

Normal mode noise rejection

60 dB @ 60 Hz(1)

Common mode noise rejection

120 dB @ 60 Hz 100 dB @ 50 Hz

Channel bandwidth

15 Hz (-3 dB)(1)

Settling time

<80 ms to 5% of full scale(1)

Calibrated accuracy 25 °C (77 °F)

Better than 0.1% of range

Calibration interval

6 months

Offset drift

2 V/°C

Gain drift with temperature

Voltage: 35 ppm/°C, 80 ppm/°C max Current: 45 ppm/°C, 90 ppm/°C max

Module error

0.54% of range

Module input scan time, min

25 ms min – floating point 10 ms min – integer(1)

46

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

Page 47

1756 ControlLogix I/O Specifications

Technical Specifications - 1756-IF6I (continued) Attribute

1756-IF6I

Onboard data alarming

Yes

Scaling to engineering units

Yes

Real-time channel sampling

Yes

Data format

Integer mode (left justified, 2 s complement) IEEE 32-bit floating point

Module conversion method

Sigma-Delta

Isolation voltage

250V (continuous), basic insulation type, input channels-to-backplane, and input channel-to-channel Routine tested at 1350V AC for 2 s

Module keying

Electronic, software configurable

Removable terminal block

1756-TBNH 1756-TBSH

RTB keying

User-defined mechanical

Slot width

1

Wire category

2(2)

North American temperature code

T4A

IEC temperature code

T4

Enclosure type

None (open-style)

(1) Notch filter dependent. (2) Use this conductor category information for planning conductor routing as described in the system-level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.

Environmental Specifications - 1756-IF6I Attribute

1756-IF6I

Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

0…60 °C (32…140 °F)

Temperature, surrounding air, max

60 °C (140 °F)

Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…+85 °C (-40…+185 °F)

Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)

5…95% noncondensing

Vibration IEC 60068-2-6 (Test Fc, Operating)

2 g @ 10…500 Hz

Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

30 g

Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock)

50 g

Emissions

CISPR 1, Class A

ESD immunity IEC 61000-4-2

6 kV contact discharges 8 kV air discharges

Radiated RF immunity IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

47

Page 48

1756 ControlLogix I/O Specifications

Environmental Specifications - 1756-IF6I (continued) Attribute

1756-IF6I

EFT/B immunity IEC 61000-4-4

±2 kV at 5 kHz on shielded signal ports

Surge transient immunity IEC 61000-4-5

±2 kV line-earth (CM) on shielded signal ports

Conducted RF immunity IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz on shielded signal ports

Certifications - 1756-IF6I Certification(1)

1756-IF6I

UL

UL Listed Industrial Control Equipment. See UL File E65584.

CSA

CSA Certified Process Control Equipment. See CSA File LR54689C. CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File LR69960C.

CE

European Union 2004/108/IEC EMC Directive, compliant with: • EN 61326-1; Meas./Control/Lab., Industrial Requirements • EN 61000-6-2; Industrial Immunity • EN 61000-6-4; Industrial Emissions • EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11)

C-Tick

Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions

Ex

European Union 94/9/EC ATEX Directive, compliant with: • EN 60079-15; Potentially Explosive Atmospheres, Protection "n" • EN 60079-0; General Requirements II 3 G Ex nA IIC T4 X Gc

FM

FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations

KC

Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3

(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

48

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

Page 49

1756 ControlLogix I/O Specifications

1756-IF8 ControlLogix voltage/current analog input module 1756-IF8 Differential Current

1756-IF8 Differential Voltage Channel 0

Channel 0 i

IN-0

2

1 i RTN-0

A

IN-1

4

3 i RTN-1

IN-2

6

5 i RTN-2

IN-3

8

7 i RTN-3

RTN

10

9

RTN

IN-4

12 11

Shield Ground Channel 3 2-wire Transmitter i A i RTN-4

IN-5

14 13

IN-6

16 15 i RTN-6

IN-7

18 17 i RTN-7

+ –

Jumper Wires

Shield Ground

Channel 3

+ i RTN-5

Not Used

20 19

Not Used

22 21

Not Used Not Used

Not Used

24 23

Not Used

Not Used

26 25

Not Used

Not Used

28 27

Not Used

Not Used

30 29

Not Used

Not Used

32 31

Not Used

Not Used

34 33

Not Used

Not Used

36 35

Not Used

• Use this table when wiring your module in Differential mode.

– Shield Ground

IN-0

2

1 i RTN-0

IN-1

4

3 i RTN-1

IN-2

6

5 i RTN-2

IN-3

8

7 i RTN-3

RTN

10

9

RTN

IN-4

12 11 i RTN-4

IN-5

14 13 i RTN-5

IN-6

16 15 i RTN-6

IN-7

18 17 i RTN-7

Not Used Not Used

20 19 22 21

Not Used Not Used

Not Used

24 23

Not Used

Not Used

26 25

Not Used

Not Used

28 27

Not Used

Not Used

30 29

Not Used

Not Used

32 31

Not Used

Not Used

34 33

Not Used

Not Used

36 35

Not Used

• Use this table when wiring your module in Differential mode.

This channel

Uses these terminals

This channel

Uses these terminals

Channel 0

IN-0 (+), IN-1 (-), i RTN-0

Channel 0

IN-0 (+), IN-1 (-)

Channel 1

IN-2 (+), IN-3 (-), i RTN-2

Channel 1

IN-2 (+), IN-3 (-)

Channel 2

IN-4 (+), IN-5 (-), i RTN-4

Channel 2

IN-4 (+), IN-5 (-)

Channel 3

IN-6 (+), IN-7 (-), i RTN-6

Channel 3

IN-6 (+), IN-7 (-)

• All terminals marked RTN are connected internally. • A 249 current loop resistor is located between IN-x and i RTN-x terminals. • If multiple (+) or multiple (-) terminals are tied together, connect that tie point to a RTN terminal to maintain the module’s accuracy. • Place additional loop devices (such as strip chart recorders) at the A location in the current loop.

• All terminals marked RTN are connected internally. • If multiple (+) or multiple (-) terminals are tied together, connect that tie point to a RTN terminal to maintain the module’s accuracy. • Terminals marked RTN or i RTN are not used for differential voltage wiring. IMPORTANT: When operating in 2-channel, High-Speed mode, only use channels 0 and 2.

IMPORTANT: When operating in 2-channel, High-Speed mode, only use channels 0 and 2.

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016

49

Page 50

1756 ControlLogix I/O Specifications

1756-IF8 Single-ended Current Channel 0 i eld Ground Channel 5 i 2-wire Transmitter

1756-IF8 Single-ended Voltage

A

IN-0

2

1 i RTN-0

IN-1

4

3 i RTN-1

IN-2

6

5

IN-3

8

7 i RTN-3

RTN

10

9

RTN

IN-4

12 11

Channel 0

Jumper Wires i RTN-2

14 13

IN-6

16 15 i RTN-6

IN-7

18 17 i RTN-7

Not Used Not Used

20 19 22 21

Not Used Not Used

Not Used

24 23

Not Used

IN-0

2

1 i RTN-0

IN-1

4

3 i RTN-1

IN-2

6

5 i RTN-2

IN-3

8

7 i RTN-3

RTN

10

9

RTN

IN-4

12

11 i RTN-4

IN-5

14

13 i RTN-5

IN-6

16

15 i RTN-6

IN-7

18

17 i RTN-7

Not Used

20

19

Not Used

Not Used

22

21

Not Used

Not Used

24

23

Not Used

26

25

Not Used

– Shield Ground i RTN-4

IN-5

+

Channel 1 i RTN-5

+ –

Shield Ground

Not Used

26 25

Not Used

28 27

Not Used

Not Used

Not Used

30 29

Not Used

Not Used

28

27

Not Used

Not Used

32 31

Not Used

Not Used

30

29

Not Used

Not Used

32

31

Not Used

Not Used

34

33

Not Used

Not Used

36

35

Not Used

Not Used

Not Used

34 33

Not Used

Not Used

36 35

Not Used

• All terminals marked RTN are connected internally. • For current applications, all terminals marked iRTN must be wired to terminals marked RTN. • A 249 current loop resistor is located between IN-x and i RTN-x terminals. • Place additional loop devices (such as strip chart recorders) at the A location in the current loop.

• All terminals marked RTN are connected internally. • Terminals marked i RTN are not used for single-ended voltage wiring.

ANALOG INPUT CAL OK

50

Rockwell Automation Publication 1756-TD002J-EN-P - November 2016