Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of 1-Slot and 2-Slot I/O Chassis with Integral Power Supply and Adapter (Cat. No. 1771-AM1 and AM2) Installation Instructions

Manual · Allen-Bradley

1-Slot and 2-Slot I/O Chassis with Integral Power Supply and Adapter (Cat. No. 1771-AM1 and AM2) Installation Instructions

Manual20 pagesPDF 224 KB

Installation instructions for the Allen-Bradley 1771-AM1 and 1771-AM2 1-slot and 2-slot I/O chassis with integral power supply and adapter.

Download the PDF224 KB

Covers · 1 model

The models it covers

Summary

What is in it

Allen-Bradley installation instructions for the 1771-AM1 (1-slot) and 1771-AM2 (2-slot) I/O chassis, which combine an I/O chassis, power supply and remote I/O adapter in one unit. It covers mounting dimensions and grounding, connecting input power and remote I/O or Data Highway communication wiring with terminating resistors, installing I/O modules, setting switches SW1 and SW2 for PLC-2, PLC-3, PLC-5 and PLC-5/250 configurations, interpreting the status indicators, and specifications.

Its parts

  1. To the Installer
  2. Installing the Chassis
  3. Connecting Input Power and Communication Wiring
  4. Installing the I/O Modules
  5. Setting the Switches for Programmable Controller Configurations
  6. Interpreting the Indicators
  7. Specifications

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Allen-Bradley installation instructions (publication 1771-2.155, February 1994) for the 1771-AM1 1-slot and 1771-AM2 2-slot I/O chassis with integral power supply and remote I/O adapter. It covers mounting, grounding, power and communication wiring, fitting the I/O module, switch settings for PLC-2, PLC-3, PLC-5 and PLC-5/250 systems, troubleshooting by the indicators, and specifications.

Device
1771-AM2: 2-slot I/O chassis with integral power supply and remote I/O adapter p. 1, 18
Module capacity
1771-AM2: 2 single-slot or 1 double-slot I/O module p. 1, 20
Input voltage
97 to 132V ac rms or 194 to 264V ac rms (switch selectable), 47 to 63 Hz p. 20
Backplane current
3A available for I/O modules p. 20
Remote I/O link
57.6K or 115.2K bps; chassis distance 10,000 ft at 57.6K, 5,000 ft at 115.2K p. 20
Processors
Switch settings given for PLC-2, PLC-3, PLC-5, and PLC-5/250 and bus scanner systems p. 10
Dimensions
1771-AM2: 5.0 x 11.75 x 7.375 in. (127 x 298.5 x 187.3 mm) p. 4, 20
Supply output
5.1V dc, 3.5A p. 20
Input power
30W/48VA (real/apparent); external transformer 75VA at full load p. 20
Fuse
1.5A slow-blow p. 4, 20
Link terminator
150 ohm, 1/4 W on the last unit of the remote I/O link; 82 ohm if the other end uses 82 ohm p. 9
Wiring blocks
Communication: A-B PN 940611-03 (Phoenix PN 1752179); input: A-B PN 941274-03 (Wago PN 231-203/000-008) p. 20
Power wiring
One 14-AWG wire (max) per terminal; strip 0.35 inches p. 5
Indicators
Power supply ACTIVE, adapter ACTIVE, FAULTED and RACK FAULT p. 18

What this manual walks you through

  • Mounting the chassis by its four mounting slots p. 1
  • Grounding the chassis and fitting keying bands and field wiring arms p. 5
  • Wiring ac power to the removable input wiring block p. 5, 7
  • Connecting remote I/O or Data Highway wiring and the terminating resistor p. 7, 9
  • Installing the I/O modules p. 9
  • Setting switches SW1 and SW2 for the processor in use p. 10, 12, 13, 14, 15, 16, 17
  • Checking which racks each PLC-5 processor can scan p. 15
  • Troubleshooting with the front indicators p. 18, 19

Good to know

  • The 1771-AM power switch must be OFF before inserting or removing the I/O module. p. 9
  • Change the switch settings only with the power switch OFF; doing it with power on can corrupt memory. p. 10
  • When cycling power, wait until all indicators are off before turning power back on. p. 10
  • Cycling power clears the block-transfer request queue, so pending block transfers are lost. p. 19
  • With a PLC-3, rack address 77 is illegal; addresses run 00 to 76. p. 14

Questions this manual answers

How many I/O modules does the 1771-AM2 hold?

Two single-slot I/O modules or one double-slot I/O module. p. 20

What input voltage does the 1771-AM2 power supply take?

97 to 132V ac rms or 194 to 264V ac rms, selected by a switch, at 47 to 63 Hz. p. 20

What does a blinking ACTIVE light with both fault lights off mean on a 1771-AM?

The adapter is not actively controlling I/O while the link is normal: the processor is in program or test mode, or the scanner holds the adapter in fault mode. p. 18

What terminating resistor does the last 1771-AM on a remote I/O link need?

A 150 ohm, 1/4 W resistor across the blue and clear terminals, or 82 ohm if the other end of the link uses 82 ohm. p. 9

Which processors can the 1771-AM2 be set up for?

The instructions give switch settings for PLC-2 (with or without complementary I/O), PLC-3, PLC-5 (with or without complementary I/O), and PLC-5/250 and bus scanner systems. p. 10

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1771-2.155, 1-Slot and 2-Slot Chassis with Integral Power Supply and Adapter Installation Instructions1
  2. To the Installer1
  3. Installing the Chassis1
  4. Connecting Input Power and Communication Wiring5
  5. Installing the I/O Modules9
  6. Setting the Switches for Programmable Controller Configurations10
  7. Interpreting the Indicators18
  8. Specifications20
  9. Back Cover20

From the PDF’s own bookmarks.

The whole text · 4 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. 1771-2.155, 1-Slot and 2-Slot Chassis with Integral Power Supply and Adapter Installation Instructions1-4
  2. Connecting Input Power and Communication Wiring5-8
  3. Pages 9 to 179-17
  4. Pages 18 to 2018-20

The file

Revision and size

RevisionPublication 1771-2.155, February 1994
PublisherAllen-Bradley
Pages20
PDF224 KB
TextText from the PDF itself.

The first pages · 3 of 20

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 20
Page 2
Page 2of 20
Page 3
Page 3of 20