The text of a manual · part 6 of 10
Bulletin 1772 Mini-PLC-2/15 Programmable Controller Assembly and Installation Manual, pages 51 to 60
Pages 51 to 60 of 94
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1772-LV
Page 51
Chapter 3 Assembly and Installation
Figure 3.28 Field Wiring Arm
Leave Sufficient Slack for Pivoting
Figure 3.29 Peeling Foil Shield
Shield’s bare wire
Shield’s foil strip
1 pair of insulated wires
10707-I
3-31
Page 52
Chapter 3 Assembly and Installation
Figure 3.30 Twisting Foil Shield and Wiring
White wire
Twist foil and bare wire together
Black wire 10708-I
Figure 3.31 Trimming Unnecessary Insulated Wire
Wire trimmed off
Strip 3/8” insulation off 30” twisted shield
2” wire 10709-I
3-32
Page 53
Chapter 3 Assembly and Installation
Figure 3.32 Cable Shield Connection
Ground Shield at I/O Chassis Mounting Bold
Shield and Drain Twisted into Single Strand Field Wiring Arm 17798
The shield cable at the field devices can be configured as described in Figure 3.33.
Incoming AC Wiring Guidelines
When bringing AC power into the enclosure, the raceway or conduit may be an equipment grounding conductor which should be connected to the ground bus on the back panel. Ground loops may introduce objectionable ground currents causing faulty operation of the Programmable Controller. If the use of multiple grounding connections results in faulty operation, refer to Article 250-21 of the National Electric Code. This Article recommends methods of reducing objectionable ground currents. Local Codes and Ordinances dictate which earth grounding method is permissible. When AC power is supplied as a separately derived system through an isolation stepdown transformer, it can be connected as a grounded AC system or an ungrounded AC system. In a grounded AC system, one side of the transformer secondary must be connected to the ground bus (Figure 3-34). In an ungrounded AC system, one side of the ground fault indicator test switch must be connected to the ground bus (Figure 3.35). 3-33
Page 54
Chapter 3 Assembly and Installation
When the System Power Supply Chassis cannot be directly connected to the enclosure or the enclosure ground bus, an equipment grounding conductor must be connected to the terminal labeled “Equipment Ground” on the System Power Supply’s terminal strip. Master Control Relay A hard-wired Master Control Relay, supplied by the user, provides emergency power shutdown for Controller I/O devices. Since the Master Control Relay allows for the placement of several Emergency Stop switches in different locations, it installation is strongly recommended. Typical Master Control Relay configurations are shown in Figure 3.34 and Figure 3.35. When any Emergency Stop switch is operated, power to input and output devices is removed. Power is still supplied to the System Power Supply so that the Processor can continue to operate even though all of its inputs and outputs are “powered down”. NOTE: The Master Control Relay is not a substitute for a disconnect to the Controller. It is intended for any situation where the operator must quickly de-energize I/o devices. When replacing any module, replacing output module fuses or working on equipment within the enclosure, power must be shut off to the Controller system.
CAUTION: It is the user’s responsibility to install the Master Control Relay and the Emergency Stop switches. The use must make certain that relay contacts have sufficient rating for the particular application. emergency Stop switches must be located to provide quick and easy access to the operator or maintenance personnel. Emergency Stop switches must be wired in series.
WARNING: Emergency Stop switches can be monitored as inputs in the user program but must not be controlled by the PC. Any Emergency Stop switch must turn off all input and output devices by de-energizing the Master Control Relay.
Input Power Connection to System Power Supply AC Line connection is made to the terminal strip located on the front of the System Power Supply (Figure 3.36). This System Power Supply is factory-shipped configured for 120V AC operation.
3-34
Page 55
Chapter 3 Assembly and Installation
WARNING: To avoid injury to personnel and damage to equipment, disconnect all AC and DC power to the Controller before attempting any wiring installation within the enclosure.
Figure 3.33 Shielded Cable at User's Device Insulated wires connect to user device.
Cut shield and bare drain wire short. Bend back and tape to insulated shield from contact at this end of cable.
10704-I
The user must reposition the two metal jumpers on the terminal strip for 220/240V AC operation. Jumper positions for both 120V AC and 220/240V AC operation are shown at the terminal strip (Figure 3-36). In addition to repositioning the jumpers for 220/240V AC operation, the main AC fuse of the System Power Supply must be changed. The Power Supply is shipped with a 1 amp slow-blow fuse installed to accommodate 120V AC operation. When the Power Supply is to operate on 220/24V AC, the 1 amp fuse must be removed and the 0.5 amp fuse, shipped separately with the Power Supply, must be installed. AC input line connections are made to L1 and L2. (L2 is the high side of the AC line; L2 is the low side). No connection is made to the equipment ground terminal when the grounding configuration illustrated in Figure 3-7 is used. Also see the last paragraph under “Incoming AC Wiring Guidelines” (Section titled Incoming AC Wiring Guidelines).
3-35
Page 56
Chapter 3 Assembly and Installation
CAUTION: The user must make certain that the System Power Supply is correctly jumpered for either 120V or 220/240V AC. Incorrect jumpering on the terminal strip may cause improper operation or damage to the Power Supply.
3-36
Page 57
Chapter 3 Assembly and Installation
Industrial Terminal Installation
The Bulletin 1770 Industrial Terminal System (Cat. No. 1770-T3) is used to program the Mini-PLC-2/15 Processor. The Industrial Terminals (Cat. No. 1770-- T1 or -T2) can be used, however they will limit the capabilities of the Mini- PLC-2/15 Processor.
WARNING: Do not use a 1770-T1 or 1770-T2 Industrial Terminal to edit or change a program or Data Table values that were generated using a 177-T3 Industrial Terminal. Block instructions and instructions with word addresses 4008 or greater will not be displayed properly. The ERR message may appear randomly in the User Program at instructions and addresses that the 1770-T1 and 1770-T2 Industrial Terminals are not designed to handle. Changes to the User Program and/or Data Table with a 1770-T1 or 1770-T2 Industrial Terminal could result in unpredictable machine motion with possible damage to equipment and/or injury to personnel.
All necessary cables for connecting the Industrial Terminal to the Mini-PLC2/15 Processor are shipped standard with the Industrial Terminal System. For ease of cable connections, sockets and connectors are configured to mate only in the proper way. Cable connections between the Processor and the Industrial Terminal can be made with power applied to both the Processor and Industrial Terminal. A grounding type AC line cord for 120V AC operation is standard with the Industrial Terminal. An AC line cord for 22/240V AC operation must be constructed. This line cord must only be plugged into a grounded AC outlet to minimize exposure to electrical hazard. The Industrial Terminal is factory-shipped configured for 120V AC operation. If the Industrial Terminal is to operate on line voltages of 220/240V AC, refer to the Industrial Terminal System User’s Manual (Publication 1770-805), for changing the AC setting and AC fuse, and for general operating procedures. The Industrial Terminal System (Cat. No. 1770-T3) is connected to the Mini-PLC- 2/15 Processor with the Program Panel Interconnect Cable (Cat. No. 172-TC). One end of this cable is connected to the socket labeled Channel A at the back of the Industrial Terminal and the other end is connected to the INTERFACE socket on the front of the Processor (Figure 3.37).
3-37
Page 58
Chapter 3 Assembly and Installation
Figure 3.34 Power Distribution with Master Control Relay, Grounded System Incoming AC
L1
L2
L3
Disconnect
F U S E
F U S E
IL1 H4
H1 H3
FUSE Use any number of E-Stop switches in Series
X1
H2
Isolation/ Step Down Transformer
F U S E
IL2
IL3
To Motor Starters Enclosure Wall
Back-Panel Ground Bus
X2 Start CRM
Equipment Grounding Conductors
1
Grounding Electrode Conductor to Earth Ground (Grounding Electrode System)
CRM PC Power Supply L1 L2 CRM
User DC Supply
2
Output Device
Connect When Applicable
CRM
Input Device
1
To minimize EMI generation, connecting a supression network is recommended: for 120V AC, Allen-Bradley cat. no. 1691-N2; for 220/240V AC, Electrocube part no. RG 1676-13.
2
To minimize generation, connecting a supression network is recommended: for 120V AC, Electrocube part no. RG 1676-14; for 220/240V AC, Electrocube part no. 1676-28.
+ To DC I/O Devices
10130-I
3-38
Page 59
Chapter 3 Assembly and Installation
Figure 3.35 Power Distribution with Master Control Relay, Ungrounded System Incoming AC
L1
L2
L3
Disconnect
F U S E
F U S E
IL1 H4
H1 H3
FUSE
H2
X1
Isolation/ Step Down Transformer
F U S E
IL2
To Motor Starters Enclosure Wall
Back Panel Ground Bus
FUSE
X2
1LT
2LT Equipment Grounding Conductors
Use any number of E-Stop switches in Series
IL3
Start
Grounding Electrode Conductor to Earth Ground (Grounding Electrode System)
CRM 1
CRM Connect When Applicable
PC Power Supply L1 L2 User DC Supply
CRM
CRM 2
Output Device
CRM + To DC I/O Devices
Input Device 1
To minimize EMI generation, connecting a supression network is recommended: for 120V AC, Allen-Bradley cat. no. 1691-N2; for 220/240V AC, Electrocube part no. RG 1676-13.
2
To minimize EMI generation, connecting a supression netwrok is recommended: for 120V AC, Electrocube part no. RG 1676-14; for 220/240V AC, Electrocube part no. 1676-28.
10131-I
3-39
Page 60
Chapter 3 Assembly and Installation
Figure 3.36 External Power Terminal Strip
L1 120V AC 220/240V AC
Jumper positions indicated at side of terminal strip
120V AC L2 EQUIP GND
10132-I
Figure 3.37 Industrial Terminal Connection Industrial Terminal
INTERFACE Channel A Cat. No. 1772-TC (10 Feet, 3.05cm)
3-40
10133-I