The text of a manual · part 4 of 6
Broadband Communication Interface (Cat. No. 1771-KRF/B) User's Manual: 3 - Selecting Channels and Setting Switches
Pages 20 to 26 of 43, from Broadband Communication Interface (Cat. No. 1771-KRF/B) User's Manual
The original document is the PDF (267 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1771-KRF
Page 20
Chapter
3
Selecting Channels and Setting Switches
Chapter Objectives
In this chapter, you read about: available channels for the KRF setting the option switches on the KRF
Available Channels for 1771-KRF The KRF module is frequency agile, which means you can change the Module operating subchannel as your application requires. The KRF operates on these standard CATV channel pairs: T12/L T13/M T14/N Table 3.A shows the frequencies for each channel pair:
Table 3.A KRF channel pair frequencies Channel Pair
Transmit (MHz)
Receive (MHz)
T12 to L
35.75 to 41.75
228 to 234
T13 to M
41.75 to 47.75
234 to 240
T14 to N
47.75 to 53.75
240 to 246
3-1
Page 21
Chapter 3 Selecting Channels and Setting Switches
The KRF operates on one of 18 750 KHz subchannels within three 6 MHz channels. Table 3.B shows the six subchannels available within each channel:
Table 3.B KRF subchannels For this Channel Pair
Use these Subchannels
And this Allen-Bradley Translator
T12 to L
1, 2, 3, 4, 5, 6
6600-XLL
T13 to M
9, 10, 11, 12, 13, 14
6600-XLM
T14 to N
17, 18, 19, 20, 21, 22
6600-XLN
Use the dipswitch settings in the next section to configure the subchannel you choose. Setting the Option Switches
The 1771-KRF has a single switch assembly with eight option switches that let you select one of 18 unique subchannel addresses. To set the option switches:
WARNING: When operating more than one DH/DH+ or remote I/O network over a common broadband system, verify that each DH/DH+ or remote I/O network uses a unique subchannel. When two or more DH/DH+ or remote I/O networks attempt to use the same subchannel, equipment damage or injury may occur due to unpredictable equipment operation and communication errors.
3-2
Page 22
Chapter 3 Selecting Channels and Setting Switches
1.
Locate the switch assembly on the KRF in figure 3.1.
Figure 3.1 KRF option switches Side of module Top
Option switch location Down
Up
17274
3-3
Page 23
Chapter 3 Selecting Channels and Setting Switches
2.
Use switches SW-1 through SW-5 to set a unique subchannel address (1-6, 9-14, 17-22) for all KRFs sharing a common link. The figure below shows the KRF switch assembly; Table 3.C shows the switch settings for each subchannel address.
Figure 3.2 KRF switch assembly Data Rate
Down = 0
1
2
3
4
5
6
7
Up = 1
8
Side View Subchannel Address
Reserved 17275
3.
If SW-7 is
The data rate is
Up
57.6K
Down
115.2K
4.
3-4
Set the baud rate using SW-7:
Switches SW-6 and SW-8 are reserved. Set them as follows:
Set this switch
To this
SW-6
Down
SW-8
Up
Page 24
Chapter 3 Selecting Channels and Setting Switches
Table 3.C Setting switches for KRF subchannel addresses Subchannel
SW-1
SW-2
SW-3
SW-4
SW-5
Do not use
DOWN
DOWN
DOWN
DOWN
DOWN
1
DOWN
DOWN
DOWN
DOWN
UP
2
DOWN
DOWN
DOWN
UP
DOWN
3
DOWN
DOWN
DOWN
UP
UP
4
DOWN
DOWN
UP
DOWN
DOWN
5
DOWN
DOWN
UP
DOWN
UP
6
DOWN
DOWN
UP
UP
DOWN
Do not use
DOWN
DOWN
UP
UP
UP
Do not use
DOWN
UP
DOWN
DOWN
DOWN
9
DOWN
UP
DOWN
DOWN
UP
10
DOWN
UP
DOWN
UP
DOWN
11
DOWN
UP
DOWN
UP
UP
12
DOWN
UP
UP
DOWN
DOWN
13
DOWN
UP
UP
DOWN
UP
14
DOWN
UP
UP
UP
DOWN
Do not use
DOWN
UP
UP
UP
UP
Do not use
UP
DOWN
DOWN
DOWN
DOWN
17
UP
DOWN
DOWN
DOWN
UP
18
UP
DOWN
DOWN
UP
DOWN
19
UP
DOWN
DOWN
UP
UP
20
UP
DOWN
UP
DOWN
DOWN
21
UP
DOWN
UP
DOWN
UP
22
UP
DOWN
UP
UP
DOWN
Do not use
UP
DOWN
UP
UP
UP
Important: Settings for SW-1 through SW-5 not specified in the table above are not used. 3-5
Page 25
Chapter 3 Selecting Channels and Setting Switches
Table 3.D shows the channel allocation for the 18 subchannels available on the KRF. Table 3.D Available frequencies and channel pairs for KRF subchannels Subchannel
TX Frequency
RX Frequency
CATV Channel Pair
Do not use
36.125
228.375
T12/L
1
36.875
229.125
T12/L
2
37.625
229.875
T12/L
3
38.375
230.625
T12/L
4
39.125
231.375
T12/L
5
39.875
232.125
T12/L
6
40.625
232.875
T12/L
Do not use
41.375
233.625
T12/L
Do not use
41.125
234.375
T13/M
9
42.875
235.125
T13/M
10
43.625
235.875
T13/M
11
44.375
236.625
T13/M
12
45.125
237.375
T13/M
13
45.875
238.125
T13/M
14
46.625
238.875
T13/M
Do not use
47.375
239.625
T13/M
Do not use
48.125
240.375
T14/N
17
48.875
241.125
T14/N
18
49.625
241.875
T14/N
19
50.375
242.625
T14/N
20
51.125
243.375
T14/N
21
58.875
244.125
T14/N
22
52.625
244.875
T14/N
Do not use
53.375
245.625
T14/N
Important: The 1771-KRF and Allen-Bradley 6608 19.2 KB Frequency Agile Modems can be installed on the same 6-MHz channel (L, M, or N) 3-6
Page 26
Chapter 3 Selecting Channels and Setting Switches using the same channel translator. However, you must leave a 100 KHz (.1 MHz) guardband between the subchannel(s) you select for the 1771-KRF and the subchannel(s) you select for the 6608 modems. See Appendix B “Using the 1771-KRF with 6608 Modems” for details.
3-7