The text of a manual · part 2 of 19
PLC-5 DeviceNet Scanner Module 1771-SDN User Manual: Preface - About This User Manual
Pages 5 to 12 of 149, from PLC-5 DeviceNet Scanner Module 1771-SDN User Manual
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1771-SDN
Page 5
Preface
About This User Manual
Introduction
This user manual is designed to provide you enough information to get a small example application up and running. Use this manual if you are knowledgeable about DeviceNet™ and PLC-5® products, but may not have used the products in conjunction with each other. The information provided is a base; modify or expand the examples to suit your particular needs. The manual contains instructions on configuring a DeviceNet network using RSLinx and RSNetWorx for DeviceNet software. It also describes how to use the PLC-5 pass-through feature to communicate with the DeviceNet network for adjustment and tuning of network devices via other networks, including: • ControlNet • Ethernet • Data Highway Plus (DH+) The example application demonstrates how to perform control on DeviceNet using a PLC-5 processor and the 1771-SDN module. You use RSLogix 5 programming software to create a ladder logic program to control a photoeye and a RediSTATION™.
IMPORTANT
1
This User manual should be used in conjunction with the 1771-SDN DeviceNet Scanner Module Installation Instructions, publication 1771-IN014. The Installation Instructions contain important information on configuring your scanner.
Publication 1771-UM118C-EN-P - June 2003
Page 6
P-2
About This User Manual
Contents
This user manual contains the following chapters:
1
4
Before You Begin go to Chapter 1
2
Planning Your Configuration go to Chapter 2
3
5
Configuring DeviceNet From Another Network go to Chapter 5
6
Setting Up the Hardware go to Chapter 3
7
Audience
Configuring the DeviceNet Network go to Chapter 4
Creating and Running the Application Program go to Chapter 6
Troubleshooting go to Chapter 7
This manual is intended for control engineers and technicians who are installing, programming, and maintaining a control system that includes a PLC-5 processor communicating on a DeviceNet network through a 1771-SDN module. We assume that you: • are developing a DeviceNet network using a PLC-5 processor in conjunction with the 1771–SDN scanner module • know each of your device’s I/O parameters and requirements • understand PLC-5 processor programming and operation • are experienced with the Microsoft® Windows™ environment • are familiar with RSNetWorx for DeviceNet software
Publication 1771-UM118C-EN-P - June 2003
Page 7
About This User Manual
The Example Application
P-3
This manual describes how to set up an example application. The manual provides examples of each step of the setup, with references to other manuals for more details.
System Components We used the following devices and software for the example application. For your own application, substitute your own devices to fit your needs. The recommended configurations in this user manual will help you set up the test system and get it working. Your eventual configuration will depend on your application. Note: If you use different software or fimware versions of these products some of your screens may appear slightly different from those shown in the example. Product Name
Catalog Number
Series
Revision
Qty
Hardware
1
PLC-5C processor(1)
1785-L20C15, -L40C15, -L80C15
-
-
1
1771 Universal I/O chassis
1771-A1B, -A2B, -A3B, -A3B1, -A4B
C
-
1
DeviceNet Scanner module
1771-SDN
C
-
1
Ethernet Interface module(2)
1785-ENET
-
-
1
DeviceNet Quad-Tap
1492-DN3TW
-
-
1
RediSTATION operator interface module 2705-TxDN1x42x-xxxx
-
-
1
Series 9000 Photoeye
42GNP-9000 or equivalent
1
DeviceNet RS-232 interface module
1770-KFD
-
-
1
RS-232 cables
1787-RSCABL/A (PC to 1770-KFD)
-
-
-
DeviceNet dropline or trunkline cables, as needed
1787-PCABL, -TCABL, -MCABL
-
-
1
24V Power Supply
Regulated 24VDC, 8A
-
-
1
PC
IBM-compatible with Microsoft Windows
Software RSLogix 5
9324-RL5300xxx
-
5.50
RSNetWorx for DeviceNet
9357-DNETL3
-
4.01
RSLinx
9355-WABxxx
-
2.40
(1)
The minimum requirement for the processor is that it support block transfer instructions. A ControlNet version of the Processor is required if interfacing the DeviceNet network and a ControlNet network (see chapters 5 and 6).
(2)
Required if interfacing the DeviceNet network and an Ethernet network. See chapters 5 and 6.
Publication 1771-UM118C-EN-P - June 2003
Page 8
P-4
About This User Manual
Common Techniques Used in This Manual
The following conventions are used throughout this manual: • Bulleted lists provide information, not procedural steps. • Numbered lists provide sequential steps. • Information in bold contained within text identifies menu windows, or screen options, screen names and areas of the screen, such as dialog boxes, status bars, radio buttons and parameters.
TIP
This is a definition box. When a word is bold within the text of a paragraph, a definition box will appear in the left margin to further define the text.
This symbol identifies helpful tips.
A definition box defines terms that may be unfamiliar to you.
Screen captures are pictures of the software’s actual screens. The names of screen buttons and fields are often in bold in the text of a procedure. Pictures of keys represent the actual keys you press.
More
Publication 1771-UM118C-EN-P - June 2003
The “MORE” icon is placed beside any paragraph that references sources of additional information outside of this document.
Page 9
About This User Manual
Where to Find More Information
More
P-5
Refer to the following publications as needed for additional help when setting up and using your DeviceNet network:
For information about
See this publication
Publication Number the 1771-SDN DeviceNet scanner
1771-SDN Scanner Module Installation Instructions
1771-IN014 the PLC-5 processor
ControlNet PLC-5 Programmable Controllers User Manual Phase 1.5
1785-UM022B-EN-P
PLC-5 Instruction Set Reference Manual
1785-6.1
1785-PLC-5 Programmable Controllers Quick Reference
1785-7.1 the1785-ENET Ethernet interface module
PLC-5 Ethernet Interface Module User Manual
1785-6.5.19 the 1771 I/O chassis
Universal I/O Chassis
1771-2.210 the 1770-KFD communication module
DeviceNet RS-232 Interface Module Installation Instructions
1770-5.6 a 1784-PCD communication card
NetLinx DeviceNet Communication Card Installation Instructions
1784-5.29 a 1784-PCID or 1784-PCIDS card
DeviceNet PCI Communication Interface Card Installation
1784-5.31 the RediSTATION
RediSTATION Operator Interface User Manual
2705-UM001EN-P the 9000 Series photoeye
{refer to the information that came with your photoeye} n/a
DeviceNet
DeviceNet System Overview
DN-2.5
DeviceNet Design Selection Guide
DNET-SG001A-EN-P connecting the DeviceNet network
DeviceNet Cable Planning and Installation Manual
DN-6.7.2
RSLinx software
RSLinx Lite User’s Guide
9399-WAB32LUG
RSLogix 5 software
Getting Results With RSLogix 5
9399-RL53GR
RSNetWorx for DeviceNet software
DeviceNet Demo CD
DNET-DM001B-EN-C terms and definitions
Allen-Bradley Industrial Automation Glossary
AG-7.1
TIP
The above are available online from the Automation Bookstore: http://www.theautomationbookstore.com.
TIP
For more information about Rockwell Software products, visit the Rockwell Software internet site: http://www.software.rockwell.com.
Publication 1771-UM118C-EN-P - June 2003
Page 10
P-6
About This User Manual
Terminology
Publication 1771-UM118C-EN-P - June 2003
This term ADR
Means Auto Device Replacement. The scanner module automates the replacement of a failed device on the network, returning it to the prior level of operation without having to use a software tool. Bridge The scanner module’s support of explicit message transfer. Change of State A type of I/O data communication. The scanner module can send and receive data with slave devices that have the change of state feature. Data is sent whenever a data change occurs. Data is updated at the rate of the heartbeat. Communication The 1771-SDN scanner module or the 1770-KFD module. Module Configuration A feature of ADR that causes the replacement device’s configuration to be Recovery made identical to the original device. Cyclic A type of I/O data communication. The scanner module can send and receive data with slave devices that have the cyclic feature. Data is only sent at a user-configurable rate. EDS Electronic Data Sheet. A vendor-supplied template that specifies how information is displayed as well as what is an appropriate entry (value). Explicit A type of messaging used for lower priority tasks, such as configuration Messaging and data monitoring. Heartbeat Rate Devices that are configured for change of state data can also send a “heartbeat” signal to indicate proper operation. Host Platform The computer that hosts the 1771-SDN scanner module. I/O An abbreviation for “input and output”. Implicit The type of messaging used for high priority I/O control data; e.g., change Messaging of state, cyclic, polled, or strobed. Input Data Data produced by a DeviceNet device and collected by the scanner module for a host platform to read. MAC ID The network address of a DeviceNet node. Network The DeviceNet network or the RSNetWorx for DeviceNet software representation of the network. Node Hardware that is assigned a single address on the network (also referred to as device). Node Recovery A feature of ADR that causes the node number of the replacement device to be automatically changed to the node number of the original device. Offline When the PC communication scanner is not communicating on the network. Online When the PC communication scanner is configured and enabled to communicate on the network. Output Data Data produced by a host platform that is written to the scanner module’s memory. This data is sent by the scanner module to DeviceNet devices. PC Abbreviation for an IBM® compatible personal-computer. Pass-Through This feature allows communication with the DeviceNet network from another network. Polled A type of input/output-data communication. A polled message solicits a response from a single, specified device on the network (a point-to-point transfer of data). Record The node address and channel-specific memory assigned in the scanner module’s non-volatile storage for a node in the scanlist. Rx An abbreviation for “receive”.
Page 11
About This User Manual
Scanlist Scanner Shared Inputs Slave Mode Strobed
Tx Quick Connect
P-7
The list of devices (nodes) with which the scanner is configured to exchange I/O data. The function of the 1771-SDN scanner module to support the exchange of I/O with slave modules. This enables multiple scanner modules to acquire inputs from a specific input device without using separate connections. The scanner module is in slave mode when it is placed in another scanner module’s scanlist as a slave device. A type of I/O data communication. A strobed message solicits a response from each strobed device (a multicast transfer). It is a 64-bit message that contains one bit for each device on the network. An abbreviation for “transmit”. This feature enables the scanner module to connect to slave devices in less than one second.
Publication 1771-UM118C-EN-P - June 2003
Page 12
P-8
About This User Manual
Notes
Publication 1771-UM118C-EN-P - June 2003