Manual · Allen-Bradley
PLC-5 DeviceNet Scanner Module 1771-SDN User Manual
Manual149 pagesPDF 3.4 MB
User manual for the Allen-Bradley 1771-SDN DeviceNet scanner module, which connects DeviceNet devices to a PLC-5 processor.
Covers · 1 model
The models it covers
Summary
What is in it
The Allen-Bradley user manual for the 1771-SDN PLC-5 DeviceNet Scanner Module. It walks through a small example application: planning and data mapping, installing the 1771-SDN, PLC-5 processor, 1785-ENET, 1770-KFD, a RediSTATION and a Series 9000 photoeye, configuring the network with RSLinx and RSNetWorx for DeviceNet, reaching DeviceNet from ControlNet, Ethernet and DH+ networks, writing a ladder program in RSLogix 5, and troubleshooting with the status indicators.
Its parts
- Before You Begin
- Planning Your Configuration and Data Mapping Your Devices
- Hardware Setup
- Configuring the DeviceNet Network
- Communicating with DeviceNet from Another Network
- Creating and Running the Example Application Program
- Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
User manual (publication 1771-UM118C-EN-P, June 2003) for the 1771-SDN DeviceNet scanner module, which links a PLC-5 processor in a 1771 I/O chassis to DeviceNet devices. It walks through an example application: hardware setup, configuring the network with RSLinx and RSNetWorx for DeviceNet, reaching DeviceNet from ControlNet, Ethernet or DH+, and a ladder program. It also explains the status indicators and numeric error codes.
- What it is
- DeviceNet scanner module for a 1771 I/O chassis, linking DeviceNet devices to a PLC-5 processor p. 18
- DeviceNet channels
- Two channels, each with a five-pin DeviceNet port, status LED and node/error display p. 45, 48
- Processor link
- Block transfers and/or discrete I/O through the chassis backplane p. 18
- Device messages
- Strobe, poll, change of state and cyclic p. 22
- Discrete I/O bits
- 2-slot addressing: 0 bits; 1-slot: 8 bits; 1/2-slot: 24 bits, each way p. 20, 21
- Node address
- 0 to 63, set by switches for each channel p. 46
- Chassis slot
- Any slot except the leftmost, which is reserved for the PLC-5 processor p. 47
- Processor needed
- A PLC-5 that supports block transfer instructions p. 7
- Series compatibility
- 1771-SDN/C is fully compatible with Series A and B; set configuration switch 5 OFF when replacing an older scanner p. 13
- Configuration software
- RSNetWorx for DeviceNet, ver. 3.11 or later for 1771-SDN/C features; 4.0 or later for Quick Connect and slave mode p. 13, 14
- PC interface
- 1770-KFD RS-232 interface module, or PC Card 1784-PCD, -PCID, or PCIDS p. 25
- RS-232 cable
- 1787-RSCABL/A (PC to 1770-KFD) p. 7
- Features
- Electronic keying, shared inputs, Auto Device Replacement, Quick Connect, slave mode p. 14
- Error codes
- Display shows the node address (0 - 63) in normal operation and codes 70 to 99 for faults p. 110, 111, 112
What this manual walks you through
- Replacing a Series A or B scanner with a Series C module p. 13
- Downloading the current EDS file for RSNetWorx p. 13
- Choosing a chassis addressing mode and its discrete I/O bits p. 20, 21
- Understanding the scanner configuration table and scanlist table p. 24, 25
- Setting the data rate, node address and chassis addressing switches p. 46
- Installing the scanner in the 1771 I/O chassis p. 47
- Connecting the scanner to the DeviceNet network p. 48
- Reading the module status and network status indicators p. 109, 110
- Looking up numeric error codes and the action for each p. 110, 111, 112
Good to know
- Do not install the scanner with the chassis power supply on; it disrupts backplane communication and may damage the module. p. 47
- Do not wire the module with power applied to the network. p. 48
- The 1771 chassis addressing mode must match the scanner's switch setting, or data is lost between processor and scanner. p. 46
- Do not disconnect the module during an application FLASH update (code 95), or its memory contents are lost. p. 112
- Change the interscan delay from its default with caution: too low slows configuration responses, too high makes I/O data less fresh. p. 25
Questions this manual answers
What does error code 78 mean on a 1771-SDN?
A slave device in the scanlist table does not exist on the network. Add the device or delete its scanlist entry. p. 111
Can a 1771-SDN Series C replace a Series A or B scanner?
Yes. It is fully compatible, but configuration switch 5 must be set to OFF when it replaces an older scanner. p. 13
What software configures the 1771-SDN?
RSNetWorx for DeviceNet, version 3.11 or later for the Series C features. It reaches the module through a 1770-KFD RS-232 interface or a 1784 PC Card. p. 13, 25
What does a flashing red module status light mean on a 1771-SDN?
The configuration is invalid. Check the DIP switch settings and the configuration setup. p. 109
Which chassis slot can the 1771-SDN go in?
Any slot of the 1771 I/O chassis except the leftmost, which is kept for the PLC-5 processor. p. 47
Contents
Chapters and sections
Each line opens the PDF at its page.
- PLC-5 DeviceNet Scanner Module1
- Important User Information2
- Rockwell Automation Support3
- Preface - About This User Manual5
- Summary of Changes13
- 1 - Before You Begin17
- What This Chapter Contains17
- What You Need to Know17
- What Your 1771-SDN Module Does18
- Address Density and Discrete I/O20
- Communicating with Your Devices22
- Communicating with Your PLC-5 Processor23
- What 1771-SDN Module Data Tables Are and What They Do24
- RSNetWorx Software as a Configuration Tool25
- What’s Next?27
- Notes28
- 2 - Planning Your Configuration and Data Mapping Your Devices29
- 3 - Hardware Setup39
50 more lines, from page 44 on
- Installing the 1771-SDN Scanner Module44
- 4 - Configuring the DeviceNet Network53
- 5 - Communicating with DeviceNet from Another Network71
- 6 - Creating and Running the Example Application Program95
- 7 - Troubleshooting109
- A - 1785-ENET Module Channel Configuration113
- B - Installing and Configuring the ControlNet Communications Driver115
- C - Installing and Configuring the DH+ Communications Driver119
- D - Data Map Example123
- E - Programming the PLC-5 Processor133
- Index141
- How Are We Doing?145
- Back Cover148
The whole text · 19 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Preface - About This User Manual5-12
- Pages 13 to 1613-16
- 1 - Before You Begin17-28
- 2 - Planning Your Configuration and Data Mapping Your Devices29-38
- 3 - Hardware Setup39-52
- 4 - Configuring the DeviceNet Network, pages 53 to 6153-61
- 4 - Configuring the DeviceNet Network, pages 62 to 7062-70
- 5 - Communicating with DeviceNet from Another Network, pages 71 to 7871-78
- 5 - Communicating with DeviceNet from Another Network, pages 79 to 8679-86
- 5 - Communicating with DeviceNet from Another Network, pages 87 to 9487-94
- 6 - Creating and Running the Example Application Program95-108
- 7 - Troubleshooting109-112
- Pages 113 to 118113-118
- C - Installing and Configuring the DH+ Communications Driver119-122
- D - Data Map Example123-132
- E - Programming the PLC-5 Processor133-140
- Index141-144
- Pages 145 to 149145-149
The file