Page 1 of PLC-5 DeviceNet Scanner Module 1771-SDN User Manual

Manual · Allen-Bradley

PLC-5 DeviceNet Scanner Module 1771-SDN User Manual

Manual149 pagesPDF 3.4 MB

User manual for the Allen-Bradley 1771-SDN DeviceNet scanner module, which connects DeviceNet devices to a PLC-5 processor.

Download the PDF3.4 MB

Covers · 1 model

The models it covers

Summary

What is in it

The Allen-Bradley user manual for the 1771-SDN PLC-5 DeviceNet Scanner Module. It walks through a small example application: planning and data mapping, installing the 1771-SDN, PLC-5 processor, 1785-ENET, 1770-KFD, a RediSTATION and a Series 9000 photoeye, configuring the network with RSLinx and RSNetWorx for DeviceNet, reaching DeviceNet from ControlNet, Ethernet and DH+ networks, writing a ladder program in RSLogix 5, and troubleshooting with the status indicators.

Its parts

  1. Before You Begin
  2. Planning Your Configuration and Data Mapping Your Devices
  3. Hardware Setup
  4. Configuring the DeviceNet Network
  5. Communicating with DeviceNet from Another Network
  6. Creating and Running the Example Application Program
  7. Troubleshooting

From the manual

Key facts from this manual

Each line names its page in the PDF.

User manual (publication 1771-UM118C-EN-P, June 2003) for the 1771-SDN DeviceNet scanner module, which links a PLC-5 processor in a 1771 I/O chassis to DeviceNet devices. It walks through an example application: hardware setup, configuring the network with RSLinx and RSNetWorx for DeviceNet, reaching DeviceNet from ControlNet, Ethernet or DH+, and a ladder program. It also explains the status indicators and numeric error codes.

Read for this summary: pages 1, 5 to 7, 13 to 14, 17 to 27, 44 to 48 and 109 to 112 of 149.

What it is
DeviceNet scanner module for a 1771 I/O chassis, linking DeviceNet devices to a PLC-5 processor p. 18
DeviceNet channels
Two channels, each with a five-pin DeviceNet port, status LED and node/error display p. 45, 48
Processor link
Block transfers and/or discrete I/O through the chassis backplane p. 18
Device messages
Strobe, poll, change of state and cyclic p. 22
Discrete I/O bits
2-slot addressing: 0 bits; 1-slot: 8 bits; 1/2-slot: 24 bits, each way p. 20, 21
Node address
0 to 63, set by switches for each channel p. 46
Chassis slot
Any slot except the leftmost, which is reserved for the PLC-5 processor p. 47
Processor needed
A PLC-5 that supports block transfer instructions p. 7
Series compatibility
1771-SDN/C is fully compatible with Series A and B; set configuration switch 5 OFF when replacing an older scanner p. 13
Configuration software
RSNetWorx for DeviceNet, ver. 3.11 or later for 1771-SDN/C features; 4.0 or later for Quick Connect and slave mode p. 13, 14
PC interface
1770-KFD RS-232 interface module, or PC Card 1784-PCD, -PCID, or PCIDS p. 25
RS-232 cable
1787-RSCABL/A (PC to 1770-KFD) p. 7
Features
Electronic keying, shared inputs, Auto Device Replacement, Quick Connect, slave mode p. 14
Error codes
Display shows the node address (0 - 63) in normal operation and codes 70 to 99 for faults p. 110, 111, 112

What this manual walks you through

  • Replacing a Series A or B scanner with a Series C module p. 13
  • Downloading the current EDS file for RSNetWorx p. 13
  • Choosing a chassis addressing mode and its discrete I/O bits p. 20, 21
  • Understanding the scanner configuration table and scanlist table p. 24, 25
  • Setting the data rate, node address and chassis addressing switches p. 46
  • Installing the scanner in the 1771 I/O chassis p. 47
  • Connecting the scanner to the DeviceNet network p. 48
  • Reading the module status and network status indicators p. 109, 110
  • Looking up numeric error codes and the action for each p. 110, 111, 112

Good to know

  • Do not install the scanner with the chassis power supply on; it disrupts backplane communication and may damage the module. p. 47
  • Do not wire the module with power applied to the network. p. 48
  • The 1771 chassis addressing mode must match the scanner's switch setting, or data is lost between processor and scanner. p. 46
  • Do not disconnect the module during an application FLASH update (code 95), or its memory contents are lost. p. 112
  • Change the interscan delay from its default with caution: too low slows configuration responses, too high makes I/O data less fresh. p. 25

Questions this manual answers

What does error code 78 mean on a 1771-SDN?

A slave device in the scanlist table does not exist on the network. Add the device or delete its scanlist entry. p. 111

Can a 1771-SDN Series C replace a Series A or B scanner?

Yes. It is fully compatible, but configuration switch 5 must be set to OFF when it replaces an older scanner. p. 13

What software configures the 1771-SDN?

RSNetWorx for DeviceNet, version 3.11 or later for the Series C features. It reaches the module through a 1770-KFD RS-232 interface or a 1784 PC Card. p. 13, 25

What does a flashing red module status light mean on a 1771-SDN?

The configuration is invalid. Check the DIP switch settings and the configuration setup. p. 109

Which chassis slot can the 1771-SDN go in?

Any slot of the 1771 I/O chassis except the leftmost, which is kept for the PLC-5 processor. p. 47

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. PLC-5 DeviceNet Scanner Module1
  2. Important User Information2
  3. Rockwell Automation Support3
  4. Preface - About This User Manual5
    1. Introduction5
    2. Audience6
    3. The Example Application7
    4. Common Techniques Used in This Manual8
    5. Where to Find More Information9
    6. Terminology10
    7. Notes12
  5. Summary of Changes13
    1. Module Compatibility and Maintenance Requirements13
    2. Electronic Data Sheet Requirement13
    3. Software Requirement13
    4. Module Enhancements and Features14
  6. 1 - Before You Begin17
    1. What This Chapter Contains17
    2. What You Need to Know17
    3. What Your 1771-SDN Module Does18
    4. Address Density and Discrete I/O20
    5. Communicating with Your Devices22
    6. Communicating with Your PLC-5 Processor23
    7. What 1771-SDN Module Data Tables Are and What They Do24
    8. RSNetWorx Software as a Configuration Tool25
    9. What’s Next?27
    10. Notes28
  7. 2 - Planning Your Configuration and Data Mapping Your Devices29
    1. What You Need to Know29
    2. Beginning the Process29
    3. The Example Network30
    4. What’s Next?37
    5. Notes38
  8. 3 - Hardware Setup39
    1. What This Chapter Contains39
    2. Installing the 1770-KFD Interface Module39
    3. Installing the PLC-5 Processor40
    4. Installing the 1785-ENET Ethernet Module43
50 more lines, from page 44 on
  1. Installing the 1771-SDN Scanner Module44
    1. Installing the RediSTATION Operator Interface49
    2. Installing the Series 9000 Photoeye50
    3. How Your Example System Will Look51
    4. What’s Next?51
    5. Notes52
  2. 4 - Configuring the DeviceNet Network53
    1. What This Chapter Contains53
    2. Installing the Software53
    3. Using RSLinx to Configure the DeviceNet Driver54
    4. Using RSNetWorx for DeviceNet to Configure the Scanlist56
    5. What’s Next?69
    6. Notes70
  3. 5 - Communicating with DeviceNet from Another Network71
    1. What This Chapter Contains71
    2. Where to Find More Information72
    3. Communicating with DeviceNet from a ControlNet Network73
    4. Communicating with DeviceNet from an Ethernet Network79
    5. Communicating with DeviceNet from a DH+ Network88
    6. What’s Next?93
    7. Notes94
  4. 6 - Creating and Running the Example Application Program95
    1. What This Chapter Contains95
    2. Installing the Software96
    3. Creating the Example Application Program96
    4. Downloading and Running the Program100
    5. What’s Next?108
  5. 7 - Troubleshooting109
    1. What This Chapter Contains109
    2. Module Status Indicator109
    3. Network Status Indicator110
    4. Node/Error Code Indicator110
  6. A - 1785-ENET Module Channel Configuration113
    1. Configuring the Communications Channel113
  7. B - Installing and Configuring the ControlNet Communications Driver115
    1. Installing the 1784-KTCX15 Communication Interface Card115
    2. Notes118
  8. C - Installing and Configuring the DH+ Communications Driver119
    1. Installing the 1784-KTX Communication Interface Card119
    2. Configuring the 1784-KTX Communications Driver120
    3. Notes122
  9. D - Data Map Example123
    1. Example Input Mapping Scheme123
    2. Example Output Mapping Scheme128
    3. Notes132
  10. E - Programming the PLC-5 Processor133
    1. Program the PLC-5 Processor133
  11. Index141
  12. How Are We Doing?145
  13. Back Cover148

From the PDF’s own bookmarks.

The whole text · 19 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Preface - About This User Manual5-12
  3. Pages 13 to 1613-16
  4. 1 - Before You Begin17-28
  5. 2 - Planning Your Configuration and Data Mapping Your Devices29-38
  6. 3 - Hardware Setup39-52
  7. 4 - Configuring the DeviceNet Network, pages 53 to 6153-61
  8. 4 - Configuring the DeviceNet Network, pages 62 to 7062-70
  9. 5 - Communicating with DeviceNet from Another Network, pages 71 to 7871-78
  10. 5 - Communicating with DeviceNet from Another Network, pages 79 to 8679-86
  11. 5 - Communicating with DeviceNet from Another Network, pages 87 to 9487-94
  12. 6 - Creating and Running the Example Application Program95-108
  13. 7 - Troubleshooting109-112
  14. Pages 113 to 118113-118
  15. C - Installing and Configuring the DH+ Communications Driver119-122
  16. D - Data Map Example123-132
  17. E - Programming the PLC-5 Processor133-140
  18. Index141-144
  19. Pages 145 to 149145-149

The file

Revision and size

Part no.1771-UM118C-EN-P
RevisionJune 2003
PublisherRockwell Automation
Pages149
PDF3.4 MB
TextText from the PDF itself; pages 1 and 149 are scans, read by OCR, which may hold reading errors.
1771-UM118C-EN-P

The first pages · 3 of 149

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 149
Page 2
Page 2of 149
Page 3
Page 3of 149