PLC-5 DeviceNet Scanner Module 1771-SDN User Manual, pages 13 to 16

Pages 13 to 16 of 149: Summary of Changes; Table of Contents

The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 1771-SDN

Page 13

Summary of Changes

Summary of Changes The information below summarizes the changes to the PLC-5 DeviceNet Scanner Module and this user manual.

Module Compatibility and The 1771-SDN/C DeviceNet Scanner Module is fully compatible with the Series A and Series B versions. You can use the Series C version as a Maintenance Requirements spare or replacement module with one requirement: you must change the position of Switch 5 to the off or “0” position in the Configuration switchbank as shown below: Configuration

Series C label

NOTE: Default scanner setting is Series C operation. When replacing an older scanner, set configuration switch 5 to the OFF position. See Installation Instructions for details.

Electronic Data Sheet Requirement

Chassis Address

To use the new features of this release, the scanner module requires the latest EDS file for RSNetWorx for DeviceNetTM software. If the software displays the device as an “unknown device”, you must download the current EDS file. Get the latest EDS file online at: http://www.ab.com/networks/eds Once you are at this location: 1. Click on DeviceNet 2. Enter the catalog number: 1771-SDN 3. Enter Major Revision: 6 4. Click on Search For more information, contact Rockwell Automation Technical Support at 440.646.5800 (or on the web at http://support.rockwellautomation.com).

Software Requirement i

To use the new features of the 1771-SDN/C module, you must use RSNetWorx for DeviceNet, ver. 3.11 (or later as specified below) as your configuration tool.

Publication 1771-UM0118-EN-P - June 2003

Page 14

Summary of Changes ii

Module Enhancements and Updated DeviceNet Master Library Features Electronic Keying - added to include Major and Minor revision checking. Shared Inputs - this enables multiple scanner modules to acquire inputs from a specific input device without using separate connections. Auto Device Replacement (ADR) - consists of Node Recovery and Configuration Recovery: • Node Recovery - this feature causes the node number of the replacement device to be automatically changed to the node number of the original device. The replacement device’s node number must be writable over the DeviceNet network and must initially be set to 63. • Configuration Recovery - this feature causes the replacement device’s configuration to be made identical to the original device. The replacement device’s configuration must be writable over the DeviceNet network. Configuration Recovery files are stored in the master scanner that is communicating with the original device through RSNetWorx for DeviceNet. Quick Connect - (requires RSNetWorx for DeviceNet 4.0 or later) this feature enables the scanner module to connect to slave devices in less than one second (previously up to 10 seconds). Slave devices must also have Quick Connect functionality.

Slave Mode (requires RSNetWorx for DeviceNet 4.0 or later) Slave mode allows processor-to-processor communication and enables the scanner to perform as a slave device to another master on the network. When the scanner module is in slave mode, it exchanges data with only one master. You control what information is exchanged through scan list configuration and associated mapping functions of RSNetWorx for DeviceNet software. This feature has the following variations: When the scanner module is in: Null mode Master mode Slave mode Dual mode

Publication 1771-UM0118-EN-P - June 2003

It: Contains an empty or disabled scan list (default) Serves as a master to on or more slaves but is not simultaneously serving as a slave to another master Serves as a slave to another master Serves as both a master to one or more slaves and as a slave to another master simultaneously

Page 15

Table of Contents Chapter 1 Before You Begin

What This Chapter Contains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 What You Need to Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 What Your 1771-SDN Module Does . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Address Density and Discrete I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Communicating with Your Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Communicating with Your PLC-5 Processor . . . . . . . . . . . . . . . . . . . . . 1-7 What 1771-SDN Module Data Tables Are and What They Do . . . . . . 1-8 RSNetWorx Software as a Configuration Tool. . . . . . . . . . . . . . . . . . . . 1-9 What’s Next?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11

Chapter 2 Planning Your Configuration and Data Mapping Your Devices

What You Need to Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Beginning the Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 The Example Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 What’s Next?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9

Chapter 3 Hardware Setup

What This Chapter Contains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Installing the 1770-KFD Interface Module. . . . . . . . . . . . . . . . . . . . . . . 3-1 Installing the PLC-5 Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Installing the 1785-ENET Ethernet Module . . . . . . . . . . . . . . . . . . . . . 3-5 Installing the 1771-SDN Scanner Module. . . . . . . . . . . . . . . . . . . . . . . . 3-6 Installing the RediSTATION Operator Interface. . . . . . . . . . . . . . . . . 3-11 Installing the Series 9000 Photoeye . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12 How Your Example System Will Look . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 What’s Next?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13

Chapter 4 Configuring the DeviceNet Network

What This Chapter Contains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Installing the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Using RSLinx to Configure the DeviceNet Driver. . . . . . . . . . . . . . . . . 4-2 Using RSNetWorx for DeviceNet to Configure the Scanlist . . . . . . . . . 4-4 What’s Next?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17

Chapter 5 Communicating with DeviceNet from Another Network i

What This Chapter Contains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Where to Find More Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Communicating with DeviceNet from a ControlNet Network . . . . . . . 5-3 Communicating with DeviceNet from an Ethernet Network. . . . . . . . 5-9 Communicating with DeviceNet from a DH+ Network . . . . . . . . . . 5-18 What’s Next?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23

Publication 1771-UM118C-EN-P - June 2003

Page 16

Table of Contents ii

Chapter 6 Creating and Running the Example What This Chapter Contains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Installing the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 Application Program Creating the Example Application Program . . . . . . . . . . . . . . . . . . . . . . 6-2 Downloading and Running the Program. . . . . . . . . . . . . . . . . . . . . . . . . 6-6 What’s Next?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14

Chapter 7 Troubleshooting

What This Chapter Contains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 Module Status Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 Network Status Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Node/Error Code Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2

Appendix A 1785-ENET Module Channel Configuration

Configuring the Communications Channel. . . . . . . . . . . . . . . . . . . . . . . A-1

Appendix B Installing and Configuring the ControlNet Communications Driver

Installing the 1784-KTCX15 Communication Interface Card . . . . . . . . B-1

Appendix C

Installing and Configuring the DH+ Installing the 1784-KTX Communication Interface Card . . . . . . . . . . . C-1 Configuring the 1784-KTX Communications Driver. . . . . . . . . . . . . . . C-2 Communications Driver Appendix D Data Map Example

Example Input Mapping Scheme. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1 Example Output Mapping Scheme. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6

Appendix E Programming the PLC-5 Processor Program the PLC-5 Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 Index

Publication 1771-UM118C-EN-P - June 2003