Spec sheet · Allen-Bradley
CompactBlock I/O for DeviceNet 1791D Technical Data
Spec sheet36 pagesPDF 4.5 MB
Technical data for Allen-Bradley 1791D CompactBlock I/O for DeviceNet, including the 1791D-0B16P base and 1791D-0B16PX expansion modules.
Covers · 2 models
The models it covers
Summary
What is in it
Allen-Bradley technical data for the 1791D CompactBlock I/O family for DeviceNet: compact blocks with I/O circuits, a built-in power supply and a built-in DeviceNet adapter. An overview covers compatibility, polled, cyclic and change-of-state communication, input filtering, idle and fault modes, indicators, power, mounting and cables. A specification sheet follows for each module, including the 16 sourcing output base module 1791D-0B16P and expansion module 1791D-0B16PX.
Its parts
- Overview
- 4 Sinking Input Base Module 1791D-4B0
- 4 Sinking Input/4 Sourcing Output Base Module 1791D-4B4P
- 8 Sinking Input/8 Sourcing Output Base Module 1791D-8B8P
- 8 Sourcing Input/8 Sinking Output Base Module 1791D-8V8P
- 16 Sinking Input Base Module 1791D-16B0
- 16 Sinking Input Expansion Module 1791D-16B0X
- 16 Sourcing Input Base Module 1791D-16V0
- 16 Sourcing Input Expansion Module 1791D-16V0X
- 8 Sourcing Output Base Module 1791D-0B8P
- 16 Sourcing Output Base Module 1791D-0B16P
- 16 Sourcing Output Expansion Module 1791D-0B16PX
- 16 Sinking Output Base Module 1791D-0V16P
- 16 Sinking Output Expansion Module 1791D-0V16PX
From the sheet
Key facts from this sheet
Each line names its page in the PDF.
Rockwell Automation technical data (publication 1791D-IN001A-EN-P, September 2000) for the thirteen 1791D CompactBlock I/O for DeviceNet modules. Its pages for the 16 sourcing output base module (printed both 1791D-0B16P and 1791D-OB16P) and its expansion module 1791D-0B16PX give wiring, power, output ratings and output bit maps. Shared pages explain communication modes, idle and fault behavior, status indicators, mounting and cables.
- Outputs
- 16 sourcing outputs in 2 groups of 8 p. 27, 28, 29, 30
- Output voltage
- 10 - 30V dc on-state range; 0.5V dc drop at rated current p. 28, 30
- Output current
- On-state 0.5A maximum; all outputs 4.0A maximum; surge 1.0A for 10ms, repeatable every 2 s; off-state leakage 1.0mA maximum p. 28, 30
- Auxiliary power
- 10 - 30V dc, 4A maximum, from an external source independent of the network p. 6, 28, 30
- Environment
- 0 to 60°C (32 to 140°F) operating; -40 to 85°C non-operating; 5-95% humidity non-condensing p. 28, 30
- Isolation
- 500V ac I/O to DeviceNet, I/O group-to-group and I/O group-to-logic p. 28, 30
- Enclosure and wiring
- IEC IP20; wire up to 14 gauge (2mm2) stranded, insulation up to 3/64 inch p. 28, 30
- DeviceNet power
- 1791D-OB16P: 11V - 25 V dc, 200mA maximum (with expansion) p. 28
- Expansion power
- 1791D-OB16PX: 5V dc, 100mA p. 30
- I/O data
- 1 byte consumed per 8 outputs; with an expansion module attached, an extra byte reports its health p. 27, 29
- Connection types
- Polled, change-of-state or cyclic, chosen in the DeviceNet scanner configuration p. 3, 27, 29
- Idle and fault outputs
- Outputs reset by default; configurable to hold last state or apply a fault value of 0 or 1 p. 4
- Setup
- Node address by rotary switches or RSNetworx for DeviceNet; autobaud detection of the network rate p. 2
- Expansion cables
- 1791D-4CMCBL 4 cm (1.6 in), shipped with the product; 1791D-10CMCBL 10 cm (4 in) p. 7
What this sheet walks you through
- How CompactBlock modules exchange data: polled, cyclic and change-of-state p. 3, 4
- Setting input filters p. 4
- Choosing idle and fault output behavior p. 4
- Reading the module/network, logic and I/O status indicators p. 5
- Powering and mounting base and expansion modules on a panel or DIN rail p. 6
- Ordering expansion and DeviceNet cables p. 7
- Wiring and specifications of the 1791D-0B16P base module p. 27, 28
- Wiring and specifications of the 1791D-0B16PX expansion module p. 29, 30
- Mapping output bits in the DeviceNet data to outputs p. 27, 29
Good to know
- The expansion module must sit close enough for the expansion ribbon cable to reach it from the base module. p. 6
- The 4 cm expansion cable ships with the product; its part number is for spare cables only. p. 7
- If the DeviceNet scanner drops off the network, the module goes to its fault state. p. 4
Questions this sheet answers
What is the output current rating of the 1791D-OB16P?
On-state current is 0.5A maximum, and module current for all outputs together is 4.0A maximum. p. 28
What power does the 1791D-OB16P need?
DeviceNet power of 11V - 25 V dc at 200mA maximum (with expansion), plus 10 - 30V dc auxiliary power, 4A maximum, for the outputs. p. 28
What cable connects a CompactBlock expansion module to its base module?
An expansion ribbon cable: the 4 cm 1791D-4CMCBL ships with the product, and a 10 cm 1791D-10CMCBL is listed. p. 6, 7
What happens to CompactBlock outputs when the PLC goes to program mode?
The scanner puts the module in idle, and by default it resets its outputs; it can instead hold the last state or apply a set value. p. 4
What does a solid red module/network status LED mean on a CompactBlock module?
An unrecoverable fault, or a communication failure from a duplicate node address or an incorrect baud rate. p. 5
Contents
Chapters and sections
Each line opens the PDF at its page.
- CompactBlock I/O for DeviceNet1
- Overview2
- Typical Configuration3
- System Compatibility3
- CompactBlock Family Module Communication3
- Input Filtering4
- Idle and Fault Mode Selection4
- Status Indicators5
- Power Supply Requirements6
- Mounting6
- CompactBlock I/O Cables7
- Specific Module Information7
- Related Publications7
- 4 Sinking Input Base Module 1791D-4BO9
- 4 Sinking Input/4 Sourcing Output Base Module 1791D-4B4P11
- 8 Sinking Input/8 Sourcing Output Base Module 1791D-8B8P13
- 8 Sourcing Input/8 Sinking Output Base Module 1791D-8V8P15
- 16 Sinking Input Base Module 1791D-16BO17
- 16 Sinking Input Expansion module 1791D-16B0X19
- 16 Sourcing Input Base Module 1791D-16V021
- 16 Sourcing Input Expansion Module 1791D-16V0X23
- 8 Sourcing Output Base Module 1791D-0B8P25
- 16 Sourcing Output Base Module 1791D-0B16P27
- 16 Sourcing Output Expansion Module 1791D-0B16PX29
- 16 Sourcing Output Base Module 1791D-0V16P31
- 16 Sourcing Output Expansion Module 1791D-0V16PX33
- Back Cover36
The whole text · 4 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file