Page 19

Chapter 2

Installing the Adapter

This chapter provides instructions for installing the adapter in a PowerFlex 7-Class drive. The 20-COMM-C Series B coax adapter, firmware revision 2.xxx or later, or 20-COMM-Q Series A fiber adapter, firmware revision 2.xxx or later, can also be installed in a DPI External Comms Kit. In this case, see Chapter 8 or the 20-XCOMM-DC-BASE Installation Instructions, publication 20COMM-IN001, supplied with the kit. Topic

Page

Preparing for an Installation

2-1

Setting the Node Address Switches

2-2

Connecting the Adapter to the Drive

2-3

Connecting the Adapter to the Network

2-6

Applying Power

2-7

Commissioning the Adapter

2-9

Preparing for an Installation Before installing the adapter, do the following: • Read the ControlNet Coax Media Planning and Installation Guide, publication CNET-IN002, or the ControlNet Fiber Media Planning and Installation Guide, publication CNET-IN001. These publications provide information on network basics, selecting cables, and setting up a network. • Verify that you have all required equipment. See Required Equipment on page 1-3.

!

ATTENTION: Risk of equipment damage exists. The adapter contains electrostatic discharge (ESD) sensitive parts that can be damaged if you do not follow ESD control procedures. Static control precautions are required when handling the adapter. If you are unfamiliar with static control procedures, see Guarding Against Electrostatic Damage, publication 8000-4.5.2.

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Page 20

2-2

Installing the Adapter

Setting the Node Address Switches

Set the adapter Node Address switches (Figure 2.1) by rotating the switches to the desired value for each digit. Important: Each node on the ControlNet network must have a unique address. Set the node address before power is applied because the adapter uses the node address it detects when it first receives power. To change a node address, you must set the new value and then remove and reapply power to (or reset) the adapter. Figure 2.1

Setting Adapter Node Address Switches

S2 (Tens Digit)

S3 (Ones Digit)

2 3

2 3

1 0

1 4 5 0 6 9

9 8

7

4 5 6 8

7

20-COMM-C coax adapter shown

Setting

Description

00

If the Node Address switches are set to ‘00’ (Program), the adapter uses the value stored in Parameter 03 - [CN Addr Cfg] for the node address. See Setting the Node Address on page 3-3.

01…99

Node address used by the adapter. The default switch setting is 02.

The Node Address switch settings can be verified by viewing Parameter 04 - [CN Addr Act] or Diagnostic Device Item number 27 (page 7-5) with any of the following drive configuration tools: • • • •

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

PowerFlex HIM Connected Components Workbench software, version 1.02 or later DriveExplorer software, version 2.01 or later DriveExecutive software, version 3.01 or later

Page 21

Installing the Adapter

Connecting the Adapter to the Drive

!

2-3

ATTENTION: Risk of injury or death exists. The PowerFlex drive may contain high voltages that can cause injury or death. Remove power from the drive, and then verify power has been discharged before installing or removing the adapter.

1. Remove power from the drive. 2. Use static control precautions. 3. Remove the drive cover or open the drive door. 4. Connect the Internal Interface cable to the DPI port on the drive and then to the DPI connector on the adapter (see Figure 2.2). 5. Secure and ground the adapter to the drive (see Figure 2.3) by doing the following: – On a PowerFlex 70 drive, fold the Internal Interface cable behind the adapter and mount the adapter on the drive using the four captive screws. – On a PowerFlex 700, PowerFlex 700H or PowerFlex 700S drive, mount the adapter on the drive using the four captive screws. Important: Tighten all screws to properly ground the adapter. Recommended torque is 0.9 N•m (8.0 lb•in).

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Page 22

2-4

Installing the Adapter

Figure 2.2

DPI Ports and Internal Interface Cables 20-COMM-C (coaxial) Adapter shown

➊

➋

PowerFlex 70 - All Frames

➌ ➍

PowerFlex 700 Frames 0 and 1 PowerFlex 700S Frames 0 and 1

PowerFlex 700 Frames 2 and Larger PowerFlex 700S Frames 2 through 6

HIM panel opens to allow access to DPI interface. To open panel, remove screws on left side of HIM panel and swing open.

PowerFlex 700H Frames 9 and Larger PowerFlex 700S Frames 9 and Larger

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Item

Description

➊

15.24 cm (6 in.) Internal Interface cable

➋

DPI Connector

➌

ControlNet cable(s)

➍

2.54 cm (1 in.) Internal Interface cable

X2 X1

➍

Page 23

Installing the Adapter

Figure 2.3

2-5

Mounting and Grounding the Adapter Drive 0.9 N•m (8.0 lb•in) 4 Places

Adapter Internal Interface Cable folded behind the adapter and in front of the drive. Ground Tab Detail

PowerFlex 70 - All Frame Sizes (Adapter mounts in drive.)

0.9 N•m (8.0 lb•in) 4 Places

PowerFlex 700 Frames 0 and 1 PowerFlex 700S Frames 0 and 1 (Adapter mounts on door.)

Verify metal ground tab is bent 90° and is under the adapter before tightening screw. After tightening the screw, verify continuity exists between the head of the screw and drive ground.

PowerFlex 700 Frames 2 and Larger PowerFlex 700S Frames 2 through 6 (Adapter mounts in drive.)

Ground Tab Detail

X2 X1

0.9 N•m (8.0 lb•in) 4 Places

PowerFlex 700H Frames 9 and Larger PowerFlex 700S Frames 9 and Larger (Adapter mounts behind HIM panel.)

Verify metal ground tab is bent 90° and is under the adapter before tightening screw. After tightening the screw, verify continuity exists between the head of the screw and drive ground.

NOTE: When installing the adapter in a PowerFlex 750-Series drive, see the 20-750-20COMM and 20-750-20COMM-F1 Communication Carrier Cards Installation Instructions, publication 750COM-IN001, supplied with the card.

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Page 24

2-6

Installing the Adapter

Connecting the Adapter to the Network

!

ATTENTION: Risk of injury or death exists. The PowerFlex drive may contain high voltages that can cause injury or death. Remove power from the drive, and then verify power has been discharged before installing or removing the adapter.

1. Remove power from the drive. 2. Use static control precautions. 3. Connect one end of a ControlNet cable to the network. See Figure 2.4 or Figure 2.5 for an example of wiring to a ControlNet network. Figure 2.4

Coax Network Wiring Example

Controller (ControlLogix with 1756-CNBR Bridge shown)

PowerFlex 7-Class Drives (each with a 20-COMM-C Adapter)

Channel A (optional redundancy)

Figure 2.5

Channel B

Fiber Network Wiring Example

Controller (ControlLogix with 1756-CNBR Bridge shown)

1786-RPA

1786-RPFS

... PowerFlex 7-Class Drives (each with 20-COMM-Q Adapter)

Star topology shown NOTE: The 20-COMM-Q is designed for use with short distance 1786-RPFS repeaters, which use the V-pin type connector.

4. Route the other end of the ControlNet cable through the bottom of the drive (Figure 2.3), and insert its ControlNet cable plug into the mating adapter receptacle. A 1786-TPS (straight tap) is recommended for connection to the 20-COMM-C (coax) adapter. For information about network system design and component installation, see the following publications: • ControlNet Coax Media Planning and Installation Guide, publication CNET-IN002 • ControlNet Fiber Media Planning and Installation Guide, publication CNET-IN001 20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Page 25

Installing the Adapter

Applying Power

!

2-7

ATTENTION: Risk of equipment damage, injury, or death exists. Unpredictable operation may occur if you fail to verify that parameter settings are compatible with your application. Verify that settings are compatible with your application before applying power to the drive.

Install the drive cover or close the drive door, and apply power to the drive. The adapter receives its power from the connected drive. When you apply power to the adapter for the first time, its topmost ‘PORT’ status indicator should be steady green or flashing green after an initialization. If it is red, there is a problem. See Chapter 7, Troubleshooting.

Start-Up Status Indications Status indicators for the drive and communication adapter can be viewed on the front of the drive (Figure 2.6) after power has been applied. Possible start-up status indications are shown in Table 2.A. Figure 2.6

Drive and Adapter Status Indicators (location on drive may vary)

PORT MOD

➋

NET A NET B

➊ STS

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Page 26

2-8

Installing the Adapter

Table 2.A Drive and Adapter Start-Up Status Indicators Item Name

Color

State

Description Drive STS Indicator

➊

STS (Status)

Green Yellow

Red

Flashing

Drive ready but not running, and no faults are present.

Steady

Drive running, no faults are present.

Flashing, drive stopped

An inhibit condition exists – the drive cannot be started. Check drive Parameter 214 - [Start Inhibits].

Flashing, drive running

An intermittent type 1 alarm condition is occurring. Check drive Parameter 211 - [Drive Alarm 1].

Steady, drive running

A continuous type 1 alarm condition exists. Check drive Parameter 211 - [Drive Alarm 1].

Flashing

A fault has occurred.

Steady

A non-resettable fault has occurred. Adapter Status Indicators

➋

PORT

MOD

NET A NET B

Green

Flashing

Normal operation. The adapter is establishing an I/O connection to the drive. It will turn steady green or red.

Steady

Normal operation. The adapter is properly connected and communicating with the drive.

Flashing

Normal operation. The adapter is operating but is not transferring I/O data to a controller.

Steady

Normal operation. The adapter is operating and transferring I/O data to a controller.

Flashing

A temporary channel error has occurred or the channel is in listen-only mode.

Steady

Normal operation for that channel. The adapter is properly connected and communicating on the network.

Red

Flashing

The channel is not receiving network activity.

Green/ Red

Flashing alternately

There is an invalid link configuration for that channel.

Green

Green

For more details on status indicator operation, see page 7-2 and page 7-3.

Configuring and Verifying Key Drive Parameters The PowerFlex 7-Class drive can be separately configured for the control and Reference functions in various combinations. For example, you could set the drive to have its control come from a peripheral or terminal block with the Reference coming from the network. Or you could set the drive to have its control come from the network with the Reference coming from another peripheral or terminal block. Or you could set the drive to have both its control and Reference come from the network. The following steps in this section assume that the drive will receive the Logic Command and Reference from the network. 1. Use drive Parameter 090 - [Speed Ref A Sel] to set the drive speed Reference to ‘22’ (DPI Port 5).

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Page 27

Installing the Adapter

2-9

2. If hard-wired discrete digital inputs are not used to control the drive, verify that unused digital input drive Parameters 361 - [Dig In1 Sel] and 362 - [Dig In2 Sel] are set to ‘0’ (Not Used). 3. Verify that drive Parameter 213 - [Speed Ref Source] is reporting that the source of the Reference to the drive is ‘22’ (DPI Port 5). This ensures that any Reference commanded from the network can be monitored by using drive Parameter 002 - [Commanded Speed]. If a problem occurs, this verification step provides the diagnostic capability to determine whether the drive/adapter or the network is the cause. TIP: For PowerFlex 750-Series drives, use drive Parameter 545 [Speed Ref A Sel] to set the drive speed Reference: a. Set the Port field to ‘Port 0 - PowerFlex 75x’. b. Set the Parameter field to point to the port (slot) in which the 20-COMM-C adapter/20-750-20COMM Communication Carrier Card are installed (for example, ‘876 - Port 6 Reference’). The number ‘876’ in the Parameter field of the example is the parameter in the drive that points to the port.

Commissioning the Adapter To commission the adapter, you must set a unique node address on the network. See Setting the Node Address on page 3-3 for details. Important: New settings for some adapter parameters are recognized only when power is applied to the adapter or it is reset. After you change parameter settings, cycle power or reset the adapter.

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P

Page 28

2-10

Installing the Adapter

Notes:

20-COMM-C/Q ControlNet Adapter User Manual Publication 20COMM-UM003F-EN-P