The text of a spec sheet · part 2 of 27
Relay and Timer Specifications, Bulletin Number 700: General Purpose Relays, pages 9 to 18
Pages 9 to 18 of 250, from Relay and Timer Specifications, Bulletin Number 700
The original document is the PDF (17 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700S-CFB620EJC
Page 9
Relay and Timer Specifications
General Purpose Relays Product Overview
Bulletin No.
700-HA
700-HB
700-HD
700-HF
Type
General-purpose Relay
General-purpose Relay
General-purpose Relay
General-purpose Relay
Features
• Pin-style terminals • Standard ON/OFF flag indicator • Electrical schematic on face • Clear cover for visual inspection • Optional push-to-test and manual override • Optional LED
• Blade-style quick connect terminals • Standard ON/OFF flag indicator • Electrical schematic on face • Clear cover for visual inspection • Optional push-to-test and manual override • Optional LED
• Flange-mounted • Blade-style quick connect terminals • Clear cover for visual inspection
• Square-base • Plug-in quick connect solder terminals • Optional push-to-test • Optional LED
Contact Form
DPDT, 3PDT
DPDT, 3PDT
DPDT, 3PDT
DPDT, 4 PDT
Contact Type
Single
Single
Single
Single
Contact Material
AgNi, AgNi + Gold
AgCdO
AgCdO
AgCdO
Operating Current, Under Resistant Load, Max
700-HA: 10 A 700-HAX: 6 A
15 A
15 A
10 A
Permissible Load, min
700-HA: 10V, 5 mA 700-HAX: 6V 1 mA
10V, 10 mA
10V, 10 mA
5V, 100 mA
Coil Voltage
AC: 6, 12, 24, 48, 110, 120, 230, 240, 277V DC: 6, 12, 24, 36, 48, 60, 80, 110, 125, 140, 220V
AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V
AC: 6, 12, 24, 120, 208, 240V DC: 6, 12, 24, 48, 110V
AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V
Permissible Coil Voltage Variation
80…110% of nom voltage at 50 Hz 80…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC
Contact Ratings
Coil Ratings
85…110% of nom voltage at 50 Hz 85…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC
Electrical Ratings Dielectric Withstand Voltage
Pole-to-pole: 2000V Contact-to-coil: 2000V Contact-to-frame: 2000V
Pole-to-pole: 2500V Contact-to-coil: 4000V Contact-to-frame: 2500V
Pole-to-pole: 2500V Contact-to-coil: 4000V Contact-to-frame: 2500V
Pole-to-pole: 1500V Contact-to-coil: 1500V Contact-to-frame: 1500V
Electrical Service Life (Cycles)
100 000 min
100 000 min
100 000 min
200 000 min 500 000 min (DPDT)
Certifications
CE. cULus, cURus, CSA, Lloyds
CE. cULus, cURus, CSA, Lloyds
CE. UR, CSA, Lloyds
CE., UR, CSA
Socket Catalog Numbers
700-HN100, 700-HN101, 700-HN125, 700-HN126, 700-HN204, 700-HN205
700-HN153, 700-HN154, 700-HN262, 700-HN264
Page
12
22
28
32
Reference
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
9
Page 10
Relay and Timer Specifications
Bulletin Number
700-HC
700-HK
700-HL
700-HP
Type
Interposing/Isolation Relay
Interposing/Isolation Relay
Interposing/Isolation Relay
Interposing/Isolation Relay
Features
• Blade-style terminals • Standard ON/OFF flag indicator • Electrical schematic on face • Clear cover for visual inspection • Optional push-to-test and manual override • Optional LED
• Optional pilot light • Retainer clip (comes with socket) • Low switching capacity • Push-to-test and manual override
• Ideal for PLC Interfaces • Built-in Coil Surge Protection • Fully Assembled Relay/Sockets • Standard LED • Relay or Solid-state Output • Optional: Leakage Current • Suppression Solution
• PCB “Pin Style” mounting • 5 mm pin spacing
Contact Form
DPDT, 4PDT
SPDT, DPDT
SPDT 1 N.O. (SSR)
DPDT
Contact Type
Single
Single
Single
Single
Contact Material
AgNi, AgNi + Gold
AgNi, AgNi + Gold
AgSnO
AgNi, AgNi + Gold
Operating Current, Under Resistant Load, Max
10 A (DPDT) 7 A (4PDT)
8 A (DPDT), 16 A (SPDT)
6 A (SPDT), 2 A (SSR DC output), 2 A (SSR AC output)
8A
Permissible Load, min
10V, 10 mA (Gold), 5V, 10 mA or 25V, 2 mA (Silver)
5V 60 mA (Silver), 5V 10 mA (Gold)
12V 6 mA (72 mW) Silver 8V, 2.5 mA (20 mW) Gold
5V 5 mA (50 mW) Gold, 5V 5 mA (300 mW) Silver
Coil Voltage
AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V
AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V
AC: 12, 24, 48, 110, 120, 230, 240V DC: 12, 24, 48, 125, 230, 240V
AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V
Permissible Coil Voltage Variation
80…110% of nom voltage at 50 Hz 80…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC
80…110% of nom voltage at 50 Hz 80…110% of nom voltage at 60 Hz 73…110% of nom voltage at DC
85…110% of nom voltage at 50 Hz 85…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC
80…110% of nom voltage at 50 Hz 80…110% of nom voltage at 60 Hz 73…150% of nom voltage at DC
Dielectric Withstand Voltage
Pole-to-pole: 1000V Contact-to-coil: 2000V Contact-to-frame: 2000V
Pole-to-pole: 1500V Contact-to-coil: 1500V Contact-to-frame: 1500V
Pole-to-pole: 1000V Contact-to-coil: 4000V Contact-to-frame: 1500V
Pole-to-pole: 2000V Contact-to-coil: 5000V
Electrical Service Life (Cycles)
100 000 min
100 000 min
100 000 min
100 000 min
Certifications
CE, cULus, cURus, CSA, Lloyds
CE, UL, UR, CSA
CE, cURus, cULus, ABS
CE, cULus, cURus, CSA, Lloyds
Socket Catalog Numbers
700-HN103, 700-HN128, 700-HN104
700-HN121, 700-HN221, 700-HN122,, 700-HN222, 700-HN223, 700-HN224
700-HN123, 700-HN230
Page Number
39
44
64
Contact Ratings
Coil Ratings
Electrical Ratings
Reference
10
50
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 11
Relay and Timer Specifications
Bulletin Number
700-HJ
700-HG
700-HHF
Type
Magnetic Latching Relay
Power Relay
Power Relay
Features
• Socket mounted • Ideal for lighting applications
• Panel mount with screw terminals • Optional magnetic blowouts for switching DC loads • Optional snap action switch
• Flange mounted • Optional LED
Contact Form
SPDT, DPDT (Single or Dual Coil)
SPST-N.O.-DM, SPDT, DPST-N.O., DPDT
SPST-NO-DM, DPDT, 3PDT
Contact Type
Single
Single
Single
Contact Material
AgCdO
AgNi
AgNi
Operating Current, Under Resistant Load, Max
10 A
40 A
20 A (3PDT), 25 A (DPDT), 30 A (SPDT)
Permissible Load, min
10V 50 mA
10V 50 mA
10V 50 mA 10V 100 mA (3PDT)
Coil Voltage
AC: 24V, 120V, 240V DC: 12V, 24V
AC: 24V, 120V, 240V, 277V, 480V DC: 12V, 24V, 48V, 110V, 220V, 250V
AC: 24V, 120V, 240V DC: 6V,12V, 24V
Permissible Coil Voltage Variation
85…110% of nom voltage at 50 Hz 85…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC
85…110% of nom voltage at 50 Hz 85…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC
85…110% of nom voltage at 50 Hz 85…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC
Dielectric Withstand Voltage
Pole-to-pole: 1500V AC Contact-to-coil: 1500V AC Contact-to-frame: 1500V AC
Pole-to-pole: 2200V AC Contact-to-coil: 2200V AC Contact-to-frame: 2200V AC
Pole-to-pole: 2200V AC Contact-to-coil: 2200V AC Contact-to-frame: 2200V AC
Electrical Service Life (Cycles)
100 000 minimum
100 000 minimum
100 000 minimum
Certifications
CE, UR, CSA
CE, UL, CSA
CE, UR, CSA
Socket Catalog Numbers
700-HN153, 700-HN154, - Page Number
71
75
80
Contact Ratings
Coil Ratings
Electrical Ratings
Reference
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
11
Page 12
Relay and Timer Specifications
700-HA General-purpose Relay •
10 A contact rating
•
DPDT, 3PDT
•
Pin-style terminals
•
Standard ON/OFF flag indicator
•
Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or multi-function timer
•
Contact choices: standard silver nickel, or bifurcated silver nickel with gold plating
Tube Base Relay with PIN Terminals (Single Contact), Mechanical ON/OFF Indicator Included(1) Description
Wiring Diagrams
Contact Rating
U.S./Canada
DPDT 2-pole 2 Form C Single AgNi Contact
10 A B300
Sockets
3PDT 3-pole 3 Form C Single AgNi Contact
700-HN125
700-HN100 700-HN204
700-HN126
700-HN101 700-HN205
10 A B300
Sockets (1)
Coil Voltage
6V AC 12V AC 24V AC 120V AC 240V AC 277V AC 6V DC 12V DC 24V DC 36V DC 48V DC 60V DC 80V DC 110V DC 125V DC 140V DC 220V DC 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC 48V DC 60V DC 80V DC 110V DC 125V DC 140V DC 220V DC
700-HA32A06 700-HA32A12 700-HA32A24 700-HA32A1 700-HA32A2 700-HA32A27 700-HA32Z06 700-HA32Z12 700-HA32Z24 700-HA32Z36 700-HA32Z48 700-HA32Z60 700-HA32Z80 700-HA32Z1 700-HA32Z01 700-HA32Z3 700-HA32Z2 700-HA33A06 700-HA33A12 700-HA33A24 700-HA33A1 700-HA33A2 700-HA33Z06 700-HA33Z12 700-HA33Z24 700-HA33Z48 700-HA33Z60 700-HA33Z80 700-HA33Z1 700-HA33Z01 700-HA33Z3 700-HA33Z2
LED Option: Add suffix (-4) to the selected 700-HA Relay Cat. No., except for the 240V AC Units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HA Relay Cat. No., except for the 240V AC units, add (-3-4L). Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HA relay. LED not available for 220V DC and 277V AC coils.
(1) For Time Modules and Surge Suppressor Modules, see Accessories.
12
Cat. No.(1)
International
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 13
Relay and Timer Specifications
Tube Base Relay with PIN Terminals (Bifurcated Contacts with Gold Overlay), Mechanical ON/OFF Indicator Included Description
DPDT 2-Pole 2 Form C Bifurcated AgNi Contacts with Gold Plating
Contact Rating
Sockets
U.S./Canada
International
6A
Sockets
3PDT 3-Pole 3 Form C Bifurcated AgNi Contacts with Gold Plating
Wiring Diagrams
700-HN125
700-HN100 700-HN204
6A
700-HN126
700-HN101 700-HN205
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Coil Voltage
Cat. No
6V AC
700-HAX2A06
12V AC
700-HAX2A12
24V AC
700-HAX2A24
120V AC
700-HAX2A1
240V AC
700-HAX2A2
277V AC
700-HAX2A27Δ
6V DC
700-HAX2Z06
12V DC
700-HAX2Z12
24V DC
700-HAX2Z24
36V DC
700-HAX2Z36
48V DC
700-HAX2Z48
110V DC
700-HAX2Z1
125V DC
700-HAX2Z01
140V DC
700-HAX2Z3
6V AC
700-HAX3A06
12V AC
700-HAX3A12
24V AC
700-HAX3A24
120V AC
700-HAX3A1
240V AC
700-HAX3A2
6V DC
700-HAX3Z06
12V DC
700-HAX3Z12
24V DC
700-HAX3Z24
48V DC
700-HAX3Z48
110V DC
700-HAX3Z1
125V DC
700-HAX3Z01
140V DC
700-HAX3Z3
13
Page 14
Relay and Timer Specifications
Accessories - 700-HA Relays Photo
Photo
14
Description
Pkg. Qty.
Cat. No.
Screw Terminal Tube Base Socket, Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Timing Relays, -HT (On-Delay), and -HRM, HRC and -HV (Repeat Cycle) Timing Relays.
10
700-HN100
Screw Terminal Tube Base Socket, Panel or DIN Rail Mounting; Open Style Construction. 8Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC, and -HV (Repeat Cycle) Timing Relays. No retainer clip required.
10
700-HN125
Screw Terminal Tube Base Sockets, Panel or DIN Rail Mounting; Guarded Terminal Construction. 11-pin for use with 3PDT 700-HA relays.
10
700-HN101
Screw Terminal Tube Base Sockets, Panel or DIN Rail Mounting; Open Style Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required.
10
700-HN126
8-Pin Socket, Can Be Used With or Without Timing Attachment or Surge Suppressor Screw Terminal Tube Base Sockets, panel or DIN Rail mounting. Guarded terminal construction. Used with DPDT 700-HA Relays.
10
700-HN204
11-Pin Socket, Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal Tube Base Sockets, panel or DIN Rail mounting. Guarded terminal construction. Used with 3PDT 700-HA relays.
10
700-HN205
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
10
199-DR1
Description
Pkg. Qty. Cat. No.
Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN204 and 700-HN205 socket
10
700-ADR
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN204 and 700-HN205 socket 10
700-ADL1R
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN204 and 700-HN205 socket
10
700-ADL2R
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN204 and 700-HN205 socket
10
700-ADL3R
Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN204 and 700-HN205 socket
10
700-AV1R
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN204 and 700-HN205 socket
10
700-AV3R
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN204 and 700-HN205 socket
10
700-AR1
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN204 and 700-HN205 socket
10
700-AR2
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 15
Relay and Timer Specifications
Photo
Pkg. Qty. Cat. No.
Description Timing Module On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets that accept plug-in accessory modules.
1
700-AT3
1
700-AT3A1
1
700-AT3A2
1
700-HT3
On-Delay U (A1/A2) LED & R t
One-Shot U (A1/A2) LED & R
1. 1 s
0.05 s…1 s
2. 10 s
0.5 s…10 s
3. 100 s
5 s…100 s
4. 10 min
0.5 min…10 min
5. 100 min
5 min…100 min
6. 10 hours
0.5 h…10 h
7. 100 hours
5 h…100 h t
8. LED Indicator
Socket and Retainer Clip Reference Relay Type
Socket
Retainer Clip
700-HA32 700-HAX2
700-HN100 700-HN125 700-HN204
700-HN157 Not Required 700-HN157
700-HA33 700-HAX3
700-HN101 700-HN126 700-HN205
700-HN157 Not Required 700-HN157
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
15
Page 16
Relay and Timer Specifications
Specifications - 700-HA Relays Attribute
700-HA
Electrical Ratings Pilot Duty Rating (1)
NEMA B300
Rated Thermal Current (Ith)
HA = 10 A – 120V, 240V; HAX = 6 A – 120V, 240V 250V IEC – 300V UL/CSA
Rated Insulation Voltage (Ui) Make
Break
Hp
120V AC
30 A
3A
1/3
240V AC
15 A
1.5 A
1
Inductive Contacts
General-purpose
10 A, 240V AC
Resistive
10 A, 30V DC
Min. Low Energy Permissible Load
HA = 10V, 5 mA HAX = 5V, 2 mA
Permissible Coil Voltage Variation
Coil Consumption ±10%
Pickup:80…110% of nom voltage at 50 Hz, 80…110% of nom voltage at 60 Hz, 80…110% of nom voltage at DC AC Coils
50 Hz
60 Hz
Inrush
3.3VA
2.85VA
Sealed
2.2VA
1.9VA
DC Coils
1.3 W
Must Dropout Voltage
20% of nom V AC; 10% of nom V DC
Max. Contact Resistance
50 MΩ (700-HA), 30 MΩ (700-HAX)
Design Specification/Test Requirements Electrical Pole-to-Pole
2000V
Contact to Coil
2000V
Electrical Life (Operating)
100 000 min. Mechanical
Degree of Protection (Open Type) IEC 529
IP 40
Mechanical Lifecycles (AC/DC)
> 20 x 106/ 50 x 106
Switching Frequency Operations
3600/HR
Coil Voltages Operating Time
See Product Selection Pickup
12 ms
Dropout
12 ms
Maximum Operating Rate Vibration Shock
4 Ops/s Endurance
5G
Operational
2.5 G
Endurance
50 G
Operational
9G Environmental
Temperature
Operating
AC/DC
–40…+70 °C
Storage
AC/DC
–40…+100 °C
Altitude
2000 m (6560 ft) Construction
Insulating Material
Molded High-Dielectric Material
Enclosure Contact Material Terminal Markings on Socket Sockets
Transparent Dust Cover 700-HA:
10 A – AgNi
700-HAX:
6 A – Bifurcated/Gold Plating AgNi In accordance with EN50 0005
8-Pin Socket, 700-HN100, -HN125, -HN204, 11-Pin Socket, 700-HN101, -HN126, -HN205
Certifications cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted (File No. E3125, Guide NLDX/NLDX7), CE Marked, CSA Certified, UR Certified (File 229473)
Standards
UL508, CSA C22.2 No. 14, EN 61810-1
(1) See NEMA Ratings and Test Values on page 5
16
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 17
Relay and Timer Specifications
Load (kVA) Contact life vs. AC1 load at 1,800 cycles/h k Reduction Factor
Cycles
Max. Switching Current (A)
Relay Performance Graphs
Voltage DC (V)
COS φ
Breaking capacity for DC1 load at 1,800 cycles/h
Load reduction factor vs. cos φ
A = load applied to one contact B = load applied to two contacts in series C = load applied to three contacts in series
Specifications - 700-HT3 Time Module Attribute
700-HT3 Electrical Ratings
Operating Voltage Range
12…240V AC (50/60 Hz) 12…240V DC 0.1 W (12V) 1.0 W (230V)
Power Consumption Mechanical Degree of Protection of Input (B1) Terminal
IP 20 (Guarded Terminal)
Input Terminal Wire Range
1.0 x 0.2 mm2…2.5 mm2 (24 AWG…14 AWG) 2.0 x 0.2 mm2…1.5 mm2 (24 AWG…16 AWG)
Input Terminal Torque Range
0.45…0.8 Nm (4…7 lb-in.)
Status Indicator Repeat Accuracy
Red (1)
±1%
Recovery Time
<50 ms Three DIP switches, seven ranges (set from 5…100% of range): 1 s, 10 s, 100 s, 10 min, 100 min, 10 h, 100 h
Selectable Timing Ranges
Three DIP switches, eight modes: 1. Power On–Delay 2. Power On One-Shot 3. Power On Repeat Cycle, On Start 4. Signal On-Delay and Signal Off-Delay
Selectable Timing Modes
Adjustable Trimmer Scale Accuracy
5. Signal Off-Delay 6. Signal On-One-Shot 7. Signal Off-One-Shot 8. Signal On and Signal Off Watchdog Monitor
±5% of Time Range
Environmental Operating
–20 °C…+50 °C (–4 °F…+122 °F)
Storage
–55 °C…+85 °C (–67…+185 °F)
Temperature Altitude
2000 m (6560 ft)
Construction Enclosure Mounting with Socket Only Sockets
Gray Plastic Housing 8- or 11-Pin Socket with Module Plug 700-HN204 (8-Pin with Plug), 700-HN205 (11-Pin with Plug)
Certifications cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CE Marked
Standards
UL508, CSA C22.2 No. 14, EN 61810-1
(1) At constant voltage and temperature.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
17
Page 18
Relay and Timer Specifications
Timing Charts - 700-HT3 Multi-function Time Module (t = Time Range 0.05 s…100 h) Terms: U is Power Input R is Relay Output S Signal, +A1 Socket, B1 Timer t is the resulting Time Delay (Red light-emitting diode) 1. Power On-delay Apply power (U) to timer. Relay contacts (R) change state after time delay (t) is complete. Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode.
3. Power On Repeat Cycle, On Start Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay (t) begins. When the time delay is complete, the contacts return to their shelf state for time delay (t) (time on = time-off). This cycle repeats until the power is removed. Terminal B1 is not used in this mode.
2. Power On One-shot Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay begins. When the time delay (t) is complete, contacts return to their shelf state. Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode.
4. Signal On-delay and Signal Off-delay Apply power (U) to timer. When the signal (S) is closed the time delay (t) begins, after the time delay is completed the relay contacts (R) change state. Opening the signal starts the time delay, after the time delay is completed the contacts return to their shelf state. If the signal is closed or opened before the time delay is complete, the time delay is reset. Contacts return to their shelf state when power is removed.
Timing Charts -Cat. No. 700-HT3 Timing Modes, Time Description, Timing Charts, and DIP Switch Selections Terms: U is Power Input R is Relay Output S Signal, +A1 Socket, B1 Timer t is the resulting Time Delay (Red light-emitting diode) 5. Signal Off-delay Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state immediately. When the signal is opened, the time delay (t) begins. If the signal is closed before the time delay is complete, the time delay is reset and the relay remains energized. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed.
7. Signal Off One-shot Apply power (U) to timer. When the signal (S) is closed and then opened, the relay contacts (R) change state immediately and the time delay (t) begins. After the time delay begins, opening or closing the signal will not reset the time delay. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed.
6. Signal On One-shot Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state immediately and the time delay (t) begins. After the time delay begins, opening or closing the signal will not reset the time delay. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed.
8. Signal On and Signal Off Watchdog Monitor Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) energize immediately and the time delay (t) begins. If the signal is opened before the time delay is complete, the relay remains energized and the time delay is reset. When the time delay is completed, the contacts return to their shelf state. If the signal is opened after the time delay is complete, the relay contacts energize immediately and the same time delay begins. Continuous cycling of the signal at a rate that is faster than the time delay causes the relay contacts to remain energized. Contacts return to their shelf state when power is removed.
18
Rockwell Automation Publication 700-TD552C-EN-P - October 2018