Page 19

Relay and Timer Specifications

Dimensions -700-HA Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

54.1 (2-1/8)

32.8 (1-3/10)

36.5 (1-9/20)

700-HA Relay

6.2 (15/64)

50 (1-63/64)

5.2 (13/64)

12.5 (1/2)

1.0 (0.04)

35.0 (1.38)

27.0 (1.06)

7.5 (0.3)

1000 (39-3/8)

Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes

Cat. No.

A

B

C

D

Approx. Shipping Wt.

199-DR1

35 (1-3/8)

27 (1-1/16)

7.5 (19/64)

1.02 (1/64)

1.85 kg (4.07 lb) (10/pkg)

199-DR4

35 (1-3/8)

27 (1-1/16)

15 (19/32)

2.3 (3/32)

3.68 kg (8 lb) (5/pkg)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

19

Page 20

Relay and Timer Specifications

Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

24.6 (31/32)

40.1 (1-37/64)

20.8 (53/64) 30.0 (1-3/16) 26 (1-1/32)

24.9 (63/64)

65.0 (2-35/64)

54.9 (2-5/32) 51.1 (2-1/64)

4.2 (5/32) 38.0 (1-1/2) #4–40 M3

Cat. No. 700-HN100

33.0 (1-19/64)

Panel Mounting

14.7 (37/64)

Cat. No. 700-HN125

Wire Size: 2 x 2.5 mm2 Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2-14 AWG… #2-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Wire Size: 2 x 2.5 mm2 Single Wire – Up to 12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG…#2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

26 (1-1/32)

30 (1-3/16)

65.0 (2-35/64)

38.0 (1-1/2) #4-40 M3

Cat. No. 700-HN101

Panel Mounting

Wire Size: 2 x 2.5 mm2 Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG…#2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

20

Cat. No. 700-HN126

Wire Size: 2 x 2.5 mm2 Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (#2–14 AWG…#2–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 21

Relay and Timer Specifications

Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 33.5 (1.32)

33.5 (1.32) 26.9 (1.06)

26.9 (1.06)

11.0 (0.43)

11.0 (0.43)

77.5 (3.05)

3.2 (0.13)

20.4 (0.80)

20.4 (0.80)

49.7 (1.96)

35.5 (1.40)

77.5 (3.05)

3.2 (0.13)

21.6 (0.85)

16.8 (0.66) 38.0 (1.50)

4.0 (0.16)

49.7 (1.96)

16.8 (0.66) 38.0 (1.50)

Cat. No. 700-HN204

35.5 (1.40)

21.6 (0.85)

4.0 (0.16)

Cat. No. 700-HN205

Wire Size: 2 x 2.5 mm2

Wire Size: 2 x 2.5 mm2

Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG… 20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG …20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

38.0 (1.50)

54 (2.13)

6.3 (0.25)

10.5 (0.41)

Cat. No. 700-HT3

Wire Size: 2 x 1.5 mm2 (#2 – 16 AWG…#1–20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

21

Page 22

Relay and Timer Specifications

700-HB Square Base Relay • 15 A contact rating • DPDT, 3PDT • Blade-style quick connect /solder terminals • Standard ON/OFF flag indicator • Options: LED, push-to-rest, and manual override • Faston 187 (4.8 x 0.5 mm) Photo

Description

DPDT 2-Pole 2 Form C Single AgCdO Contact

Contact Rating

Wiring Diagrams U.S./Canada

International

15 A B300

Sockets

3PDT 3-Pole 3 Form C Single AgCdO Contact

700-HN154

700-HN153

15 A B300 Input

Sockets

700-HN154

700-HN153

(1) LED Option: Add suffix (-4) to the selected 700-HB Relay Cat. No., except for the 240V AC Units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HB Relay Cat. No., except for the 240V AC units, add (-3-4L) Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HB relay.

22

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Cat. No.(1)

6V AC

700-HB32A06

12V AC

700-HB32A12

24V AC

700-HB32A24

32

120V AC

700-HB32A1

34

240V AC

700-HB32A2

6V DC

700-HB32Z06

12V DC

700-HB32Z12

24V DC

700-HB32Z24

48V DC

700-HB32Z48

110V DC

700-HB32Z1

6V AC

700-HB33A06

12V AC

700-HB33A12

24V AC

700-HB33A24

120V AC

700-HB33A1

240V AC

700-HB33A2

6V DC

700-HB33Z06

12V DC

700-HB33Z12

24V DC

700-HB33Z24

48V DC

700-HB33Z48

110V DC

700-HB33Z1

31

Input

Coil Voltage

Page 23

Relay and Timer Specifications

Accessories - 700-HB Relays Photo

Description

Pkg. Qty. Cat. No.

Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN204 and 700-HN205 socket

10

700-ADR

Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN204 and 700-HN205 socket 10

700-ADL1R

Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN204 and 700-HN205 socket

10

700-ADL2R

Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN204 and 700-HN205 socket

10

700-ADL3R

Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN204 and 700-HN205 socket

10

700-AV1R

Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN204 and 700-HN205 socket

10

700-AV3R

RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN204 and 700-HN205 socket

10

700-AR1

RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN204 and 700-HN205 socket

10

700-AR2

Timing Module On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets that accept plug-in accessory modules.

1

700-AT3

1

700-AT3A1

1

700-AT3A2

1

700-HT3

Timing Module On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets that accept plug-in accessory modules.

On-Delay U (A1/A2) LED & R t

One-Shot U (A1/A2) LED & R t

Timing Module On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets that accept plug-in accessory modules. 1. 1 s

0.05 s…1 s

2. 10 s

0.5 s…10 s

3. 100 s

5 s…100 s

4. 10 min

0.5 min…10 min

5. 100 min

5 min…100 min

6. 10 hours

0.5 h…10 h

7. 100 hours

5 h…100 h

8. LED Indicator

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

23

Page 24

Relay and Timer Specifications Photo

Description

Cat. No.

Screw Terminal Socket, Panel or DIN Rail Mounting. Guarded Terminal Construction 11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the ability to use optional plug-in modules (700-A__ accessories, LED, surge suppression, timing modules).

10

700-HN153

Screw Terminal Base Socket, Panel or DIN Rail Mounting. Open Style Construction 11-blade for use with 700-HB relays.

10

700-HN154

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

Retainer Clip For Cat. Nos. 700-HN154 Sockets with 700-HB Relays Secures relay in socket. Order must be for 10 clips or multiples of 10.

10

700-HN156

Retainer Clip For Cat. Nos. 700-HN153 Sockets with 700-HB Relays Secures relay in socket. Order must be for 10 clips or multiples of 10.

10

700-HN158

Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot on top of product covers.

100

1492-MS5X12 1492-MS6X9 1492-MS6X12 1492-MS8X9 1492-MS8X12 1492-MP-Blank

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N40

Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N41

Socket and Retainer Clip Reference Relay Type

Socket Cat. No.

Retainer Clip Cat. No.

700-HB

700-HN153 700-HN154

700-HN158 700-HN156

24

Pkg. Qty.

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 25

Relay and Timer Specifications

Specifications - 700-HB Relays Attribute

700-HB Electrical Ratings

Pilot Duty Rating (1) Rated Thermal Current (Ith)

NEMA B300 15 A – 120V, 240V 250V IEC-300V UL/CSA

Rated Insulation Voltage (Ui) Make

Break

Hp

Inductive Contacts

120V AC 240V AC General-purpose Resistive Min. Low Energy Permissible Load

2 -Pole 60 A 30 A

3 -Pole 30 A 15 A

Permissible Coil Voltage Variation

Coil Consumption ±10%

AC Coils Inrush Sealed DC Coils

2 -Pole 3 -Pole 6A 3A 3A 1.5 A 15 A, 240V AC 15 A, 30V DC 1000 mW (10V, 10 mA) 80…110% of Nominal Voltage at 50 Hz 80…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC

50 Hz

60 Hz

3.3VA 2.2VA

2.85VA 1.9VA

3/4 2

1.3 W 25% of VA 10% of W 50 MΩ

Max. Allowable Leakage Max. Contact Resistance Design Specification/Test Requirements

Dielectric Withstand Voltage Pole-to-Pole Contact to Coil

2500V 4000V Mechanical

Degree of Protection (Open Type) IEC 529 Mechanical lifecycles (AC/DC) Switching Frequency Operations Coil Voltages Pickup Operating Time (ms) Dropout Maximum Operating Rate Endurance Vibration Operational Endurance Shock Operational

IP 40 > 10 x 106/30 x 106 3600/HR See Overview/Product Selection 20 ms 4 ms 4 Ops/s 5G 1.5 G 50 G 15 G Environmental

Temperature

Operating Storage

AC/DC AC/DC

–40…+70 °C –40…+100 °C

Altitude

2000 m (6560 ft) Construction

Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards

Molded High Dielectric Material Transparent Dust Cover AgCdO In accordance with EN50 0005 700-HN153, -HN154 cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted UL508, CSA C22.2 No. 14, EN 61810-1

(1) See NEMA Ratings and Test Values on page 5

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

25

Page 26

Relay and Timer Specifications

Cycles

Technical Data - 700-HB Relays

Load (kVA)

Maximum Switching Current (A)

Contact life versus AC1 load at 600 cycles/h.

Voltage DC (V)

Reduction Factor

Breaking capacity for DC1 load at 600 cycles/h. Load applied to one contact. A = for N.O. types B= other types

(Highly Resistive)

COS φ

(Inductive)

Load Reduction factor versus cos φ

26

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 27

Relay and Timer Specifications

Dimensions - 700-HB Relays Approximate Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 60.9 (2.40)

35.8 (1.41)

30.25 (1.19)

38.2 (1.50)

27.0 (1.06)

40 (1.57)

34.3 (1.35) Ø 3.2 (0.13)

91.3 (3.59)

51.4 (2.02)

35.4 (1.39)

95.3 (3.75) 46.3 (1.82)

21.6 (0.85)

32.0 (1.26)

35.5 (1.40)

700-HB Relay

Cat. No. 700-HN153 2

Wire Size: 2 x 2.5 mm Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG… 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

49.5 (1.95)

25.6 (1.01)

35.4 (1.40)

38.0 (1.50)

84.85 (3.34) 54 (2.13)

84.3 (3.32)

41.5 (1.63)

6.3 (0.25)

4.0 (0.16)

Cat. No. 700-HN154

10.5 (0.41)

Cat. No. 700-HT3

Wire Size: 2 x 2.5 mm2

Wire Size: 2 x 1.5 mm2 (#2 – 16 AWG…#1–20 AWG)

Single Wire – Up to #12 AWG Double Wire – 2 x 2.5 mm2 (14 AWG… 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

(Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

27

Page 28

Relay and Timer Specifications

700-HD Flange Mount Square Base Relay • Flange-mounted/panel-mounted • 15 A contact rating • DPDT, 3PDT • Blade-style quick connect terminals (0.187 x 0.020) • Solder terminals (no socket required)

Photo

Wiring Diagrams U.S./Canada

Contact Rating

DPDT 2-Pole 2 Form C AgCdO Contacts

International

32

15 A

34 31

Input

3PDT 3-Pole 3 Form C AgCdO Contacts

15 A

Input

Coil Voltage

Cat. No.

6V AC 12V AC 24V AC 120V AC 208V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 6V AC 12V AC 24V AC 120V AC 208V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC

700-HD32A06 700-HD32A12 700-HD32A24 700-HD32A1 700-HD32A20 700-HD32A2 700-HD32Z06 700-HD32Z12 700-HD32Z24 700-HD32Z48 700-HD32Z1 700-HD33A06 700-HD33A12 700-HD33A24 700-HD33A1 700-HD33A20 700-HD33A2 700-HD33Z06 700-HD33Z12 700-HD33Z24 700-HD33Z48 700-HD33Z1

Accessories - 700-HD Relays Photo

28

Pkg. Cat. No. Qty.

Description

Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot on top of product covers.

100

1492-MS5X12 1492-MS6X9 1492-MS6X12 1492-MS8X9 1492-MS8X12 1492-MP-Blank

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N40

Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N41

Rockwell Automation Publication 700-TD552C-EN-P - October 2018