The text of a spec sheet · part 25 of 27
Relay and Timer Specifications, Bulletin Number 700, pages 228 to 235
Pages 228 to 235 of 250
The original document is the PDF (17 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700S-CFB620EJC
Page 228
Relay and Timer Specifications
Photo
Description
Pkg. Quantity
Cat. No.
Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N40
Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N41 (1)
Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in socket.
10
700-HN114
(1) Series B retainer clip must be used with 700-SC
Specifications- 700-SC Relays Control/Input Ratings Max. Reverse Control Voltage [V]
Impedance
700-SCTY3Z24
5…24V DC 100/110V AC 200/220V AC 24V DC
Max. Operating Control Voltage Range 4…28V DC 75…125V AC 150…250V AC 19.2…28.8V DC
-28.8 NA NA -28.8
4V DC max. 75V AC max. 150V AC max. 19.2V DC max.
700-SCNY3Z25
5…24V DC
4…28V DC
-28
15mA max.(1) 41 kΩ ±20% 72 kΩ ±20% 2 kΩ ±20% 1.5 kΩ +20%/ -10% (2)
4V DC max.
15mA max. (1) 2 kΩ ±20%
3V DC max. 19.2V DC max.
1.5 kΩ +20%/ -10%
3V DC max.
Cat. No.
Rated Control Voltage
700-SCZY3Z25 700-SCZY2A1 700-SCZY2A2
700-SCZN3Z26 700-SCTN3Z24 700-SCNN3Z26 700-SCNN2Z25
4…24V DC 24V DC 4…24V DC 5…24V DC
3…28V DC 19.2…28.8V DC 3…28V DC
-28.8 -28.8 -28 -28.8
(2)
Control Voltage Levels Pick-up Voltage Drop-out Voltage 1V DC min. 20V AC min. 40V AC min.
1V DC min.
Load/Output Ratings Cat. No.
Rated Control Voltage
Max. Load Voltage Range
100…240V AC
75…264V AC
Continuous Load Current (Resistive) [A] Min. Max. (3)
Max. Inrush Current (4)
700-SCZY3Z25 700-SCTY3Z24 700-SCZN3Z26 700-SCTN3Z24
0.1
700-SCZY2A1 700-SCZY2A2 700-SCNN3Z26 700-SCNY3Z25 700-SCNN2Z25 (1) (2) (3) (4)
3 45 A (@50/60 Hz, 1 cycle)
0.1
2
4…48V DC
3…52.8V DC
0.1
3
18 A (10 ms)
5…110V DC
3…125V DC
0.1
2
10 A (10 ms)
With constant current input circuit system. SSR impedance varies with a change in input (control) voltage. Input impedance attains its maximum at the operating voltage. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See “Inrush Current Resistivity” graphs on page 112 for details See the following “Load Current Versus Ambient Temperature Characteristics” graphs on page 112 for additional load current details.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
227
Page 229
Relay and Timer Specifications
Characteristics Description
Cat. No. 700-SCZ…
Load Switching Method/Device
Pick-up time
Drop-out time Output On Voltage Drop Output Leakage Current Output VDRM, VCEO (V) Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S) Output Tj (°C) Max. Insulation Resistance Dielectric Strength Vibration Resistance (max.) Shock Resistance (max.) Ambient Temperature Standards Compliance Certifications Ambient Humidity Weight
Cat. No. 700-SCT
Cat. Nos. 700-SCNY, 700Cat. Nos. 700-SCNN2… SCNN3… Transistor
Triac 1/2 of load power source cycle time (1) + 1 ms max. (DC input) 3/2 of load power source cycle time (1) + 1 ms max. (AC input) 1/2 of load power source cycle time (1) + 1 ms max. (DC input) 1/2 of load power source cycle 2 ms max. 2.5 ms max. time (1) + 1 ms max. 3/2 of load power source cycle (1) time + 1 ms max. (AC input) 1.6V (RMS) max. 1.6V (RMS) 1.5V max. 1.5V max. 5 mA max (@ 100V AC) 2.5 mA max (@ 100V AC) 5 mA max (@ 50V DC) 0.1 mA max (@ 100V DC) 10 mA max (@ 200V AC) 5 mA max (at 200V AC) 600 600 80 80 50 50, - 250 250, - 18 18, - 125 125 150 150 100 MΩ min (@500V DC) 1500V AC, 50/60 Hz for 1 minute 10…55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G) Operating: -30…+80 °C (-22...+176 °F) with no icing or condensation Storage: -30…+100 °C (-22...+212 °F) with no icing or condensation UL 508, CSA C22.2 No. 14, EN/IEC 60950, EN 50011, EN 61000-6-2, EN/IEC 60947-1, -4-3 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Operating: 45…85% (no condensation) Approx. 50 g
(1) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms
Load Current Versus Ambient Temperature Characteristics
700-SC_ _2... 5
4
4
Ambient Temperature [° C]
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
100
80
60
40
100
80
60
0 40
0 20
1
0
1
Ambient Temperature [° C]
228
2
20
2
3
0
3
-30 -20
Load Current [A]
5
-30 -20
Load Current [A]
700-SC_ _3...
Page 230
Relay and Timer Specifications
Inrush Current Resistivity (1) 700-SCNN3...
Energizing Time [ms]
8 6 4
5000
3000
1000
300 500
0
100
2
20 30 50
Inrush Current [A. Peak]
Energizing Time [ms]
10
10
5000
500
1000
200
10
0
100
10
2000
20
700-SCNN2... 12
1000
30
700-SCNY3
200 300 500
Inrush Current [A. Peak]
40
30 50
Inrush Current [A. Peak]
50
30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0
20 30 50 70 100
700-SCT...
10
700-SCZ....
Energizing Time [ms]
(1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input
700-SC
Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC
Output
Varistor
Film capacitor
• Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input
700-SC
Output
• The input cable must be less than 10 m.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
229
Page 231
Relay and Timer Specifications
Dimensions - 700-SC Relays All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes. Terminal Arrangement/ Internal Connections (Bottom View)
28 max.
1
4
5
8(+) Load
9
Load
(+)
12(–) (–)
21.5 max.
13
36.5 max.
Input
14
–
42.5 max. –
Note:
Load power supply
+ Input voltage
+
The plus and minus symbols shown in parentheses are for DC loads.
Cat. No 700-SC… (1) (1)
700-SC is compatible with Cat. Nos. 700-HN103, -HN104, and -HN128 socket.
Basic Application Considerations for 700-SC High-density Mounting of Multiple Solid-state Relays (SSRs) If multiple relays are mounted side by side, the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Connection For DC Load Switching, 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal.
Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table below. Load Voltage [V AC]
Varistor Voltage [V]
100…120
240…270
200…240
440…470
380…480
820…1000
TIP
Varistor Surge Resistance
1000 A min.
For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.
Load Input
230
SSR
Load power supply
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 232
Relay and Timer Specifications
700-SF Square Base Relays • 3 A (resistive) max. continuous load (output) current • 264V AC or 52.8V DC max. load voltage options • 4…24V DC control/input voltage • Photocoupler or phototriac isolation option between control and output voltage • LED Indicator for input/logic ON/OFF status monitoring 700-HN116 socket compatible
•
Input-to-Output Isolation Method
Zero Cross Function
Photocoupler
Yes
Phototriac
No
Photocoupler
Not Applicable
Status Indicator
Yes
Output (Load) Max. Continuous Current and Rated Voltage Range
Rated Input Control Voltage
Cat. No.
3 A @ 100…240V AC (47...63 Hz)
5…24V DC
700-SFZY3Z25
24V DC
700-SFTY3Z24
3 A @ 4…48V DC
4…24V DC
700-SFNY3Z25
Accessories-700-SF Relays Photo
(1)
Description
Pkg. Quantity
Cat. No.
Screw Terminal Socket, Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays.
10
700-HN116
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
10
199-DR1
Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N40
Blank Identification Tags, contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N41
Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in socket.
10
700-HN114(1)
700-SF must use Cat. No. 700-HN114 series B retainer clip.
Specifications- 700-FS Relays Control/Input Ratings Cat. No.
Rated Control Voltage
Max. Operating Control Voltage Range [V DC]
Max. Reverse Control Voltage [V]
Impedance
700-SFZY3Z25
5…24V DC
4…28V DC
–32
700-SFTY3Z24
24V DC
19.2…28.8V DC
700-SFNY3Z25
5…24V DC
4…28V DC
Control Voltage Levels Pick-up Voltage
Drop-out Voltage
15 mA max. (1)
4V DC max.
1V DC min.
–28.8
2 kΩ ± 20%
19.2V DC max.
1V DC min.
–28.8
1.5 kΩ + 20%/– 10% (2)
4V DC max.
1V DC min.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
231
Page 233
Relay and Timer Specifications
Load/Output Ratings Cat. No.
Rated Control Voltage
Max. Load Voltage Range
Continuous Load Current (Resistive) [A]
700-SFZY3Z25
100…240V AC
75…264V AC
4…48V DC
3…52.8V DC
700-SFTY3Z24 700-SFNY3Z25
Max. Inrush Current (4)
Min.
Max. (3)
0.1
3
0.1
3
45 A @ 50/60 Hz, 1 cycle
0.1
3
18 A (10 ms)
Characteristics Description Load Switching Method/Device
Output VDRM, VCEO (V)
Cat. No. 700-SFZY3Z25 Cat. No. 700-SFTY3Z24 Triac Transistor 1/2 cycle of load power source 1 ms max. cycle time (5) + 1 ms max. 1/2 cycle of load power source cycle time (5) + 1 ms max. 1.6V (RMS) max. 5 mA max. (@ 100V AC); 2.5 mA max. (@ 100V AC); 5 mA max. (@ 200V AC) 10 mA max. (@ 200V AC) 600 600
Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S)
50 250 18
50 250 18, - - Output Tj (°C) Max. Insulation Resistance Dielectric Strength Vibration Resistance (Max.) Shock Resistance (Max.)
125 100 MΩ min. (at 500V DC) 1,500V AC, 50/60 Hz for 1 min 10…55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G)
125
150
Ambient Temperature
Operating: –30…+80 °C (–22…+176 °F) with no icing or condensation Storage: –30…+100 °C (–22…=212 °F) with no icing or condensation
Ambient Humidity Standards Compliance Certifications Weight
45…85% (no condensation) UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-3, EN/IEC 60950 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Approx. 50 g
Pick-up Time Drop-out Time Output ON Voltage Drop Output Leakage Current
Cat. No. 700-SFNY3Z25 0.5 ms max. 2 ms max. 1.5V max. 5 mA max. (@ 50V DC) 80
(1) With constant current input circuit system, SSR impedance varies with a change in input voltage. (2) (3) (4) (5)
Input impedance reaches its maximum at the operating voltage. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the “Inrush Current Resistivity” graphs on page 116 for more details. See “Load Current vs. Ambient Temperature Characteristics” on page 116 for additional load current details. 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time 20 ms.
IMPORTANT
232
This data is non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 234
Relay and Timer Specifications
Inrush Current Resistivity (1)
Inrush Current Resistivity (1)
700-SFZ… 700SFT…
700-SFN…
Ambient Temperature [° C]
2000
1000
500
200 300
5000
1000
10
100
80
60
40
20
-20
-30
0
0
0
500
10
50 70 100
Inrush Current [A]
20
200
1
30
100
2
40
30 50
3
30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 20 30
50
Inrush Current [A Peak]
Load Current [A]
4
10
Load Current vs. Ambient Temperature Characteristics 700-SF
Energizing Time [ms]
Energizing Time [ms]
(1) Inrush current resistivity is defined as the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input
700-SF
Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC
Output
Varistor
Film capacitor
• Connect a varistor between the output terminals. • Connect a film capacitor to the load power supply. • The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input
700-SF
Output
• The input cable must be less than 10 m.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
233
Page 235
Relay and Timer Specifications
Dimensions - 700-SF Relays All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes.
Terminal Arrangement/Input Connections (Bottom View)
28 max
1
2
3
4(+)
5
Load
6(-)
7
Input
8
Load
(+)
(-)
-
36.5 max 42.5 max
21.5 max
-
+
Input Voltage
+
Notes: 1. The plus and minus symbols shown in parentheses are for DC loads. 2. The coil has no polarity.
IMPORTANT
700-SF is compatible with Cat. No. 700-HN116 socket.
Basic Application Considerations of 700-SF High-density Mounting of Multiple Solid-state Relays (SSRs) If multiple SSRs are mounted side by side, the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Connection For DC load switching, the Bul. 700-SF SSR will operate properly if the load is connected to either the positive or negative load terminals.
Protective Component to Extend SSR Life When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table. Load Voltage [V AC]
Varistor Voltage [V]
100…120
240…270
200…240
440…470
380…480
820…1000
TIP
Varistor Surge Resistance
1000 A min.
For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.
Load Input
234
SSR
Load power supply
Rockwell Automation Publication 700-TD552C-EN-P - October 2018