The text of a spec sheet · part 26 of 27
Relay and Timer Specifications, Bulletin Number 700, pages 236 to 243
Pages 236 to 243 of 250
The original document is the PDF (17 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 700S-CFB620EJC
Page 236
Relay and Timer Specifications
700-SH Hockey Puck Relays • 100 A max. continuous load (output) current with appropriate heat sink • 264V AC, 530V AC, or 660V AC max. load voltage options • 3…32V DC, 4…32V DC, 80…130V AC, 200…260V AC, 20…280V AC/22…48V DC control (input) voltage options • LED indicator for input/logic ON/OFF status monitoring • Protective cover for added safety
Photo
Input-toOutput Isolation Method
Zero Cross Function
Yes
Status Indicator
Yes
Output (Load) Max. Continuous Current and Rated Voltage Range (1)
Rated Input Control Voltage
Cat. No.(2)
10 A @ 42…265V AC
3…32V DC
700-SH10JZ24
10 A @ 42…265V AC
80…130V AC
700-SH10JA12
10 A @ 42…265V AC
200…260V AC
700-SH10JA22
10 A @ 42…530V AC
4…32V DC
700-SH10HZ25 (Series B)
25 A @ 42…530V AC
4…32V DC
700-SH25HZ25 (Series B)
25 A @ 24…265V AC
3…32V DC
700-SH25GZ24
25 A @ 24…265V AC
20…280V AC/ 22…48V DC
700-SH25GA24
50 A @ 24…265V AC
3…32V DC
700-SH50GZ24
50 A @ 24…265V AC
20…280V AC/ 22…48V DC
700-SH50GA24
50 A @ 42…530V AC
4…32V DC
700-SH50HZ25
25 A @ 42…660V AC
4…32V DC
700-SH25VZ25
25 A @ 42…660V AC
20…280V AC/ 22…48V DC
700-SH25VA24
50 A @ 42…660V AC
4…32V DC
700-SH50VZ25
50 A @ 42…660V AC
20…280V AC/ 22…48V DC
700-SH50VA24
75 A @ 42…530V AC
4…32V DC
700-SH75HZ25
75 A @ 42…660V AC
4…32V DC
700-SH75VZ25
75 A @ 42…530V AC
20…280V AC/ 22…48V DC
700-SH75HA24
75 A @ 42…660V AC
20…280V AC/ 22…48V DC
700-SH75VA24
100 A @ 42…530V AC
4…32V DC
700-SH100HZ25
100 A @ 42…530V AC
20…280V AC/ 22…48V DC
700-SH100HA24
100 A @ 42…660V AC
4…32V DC
700-SH100VZ25
100 A @ 42…660V AC
20…280V AC/ 22…48V DC
700-SH100VA24
5 A @ 3...60V DC
3…32V DC
700-SH5FZ24
25 A @ 90…280V AC
4…20 mA DC
700-SH25WA25
50 A @ 90…280V AC
4…20 mA DC
700-SH50WA25
Optocoupler
Yes
No
Yes
Yes
(1) When used with heat sink. (2) All catalog numbers are Series A unless noted.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
235
Page 237
Relay and Timer Specifications
Accessories - 700-SH Relays Photo
236
Description
Pkg. Quantity
Cat. No.
Heat Sink - Panel or DIN Rail Mount
1
700-SN10
Heat Sink - Panel or DIN Rail Mount
1
700-SN25
Heat Sink - Panel or DIN Rail Mount
1
700-SN50
Heat Sink - Panel or DIN Rail Mount
1
700-SN50HC
Heat Sink - Panel or DIN Rail Mount
1
700-SN50VHC
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
10
199-DR1
Thermal Conductive Pads
50
700-SHCPAD
Plastic Covers, for DC output version
25
700-SHCOV
Thermal Adapters - for 100 A Wire
10
700-SHTRMA
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 238
Relay and Timer Specifications
Specifications- 700-SH Relays Control/Input Ratings Cat. No.
Operating Voltage
Input Current @ Max. Voltage
Voltage Level Pickup Voltage
Drop-out Voltage
3…32V DC
12 mA
2.75V DC max.
1.2V DC min.
80…130V AC
13 mA
70V AC max.
30V AC min. (1)
200...280V AC
13 mA
190V AC max.
90V AC min.
4…32V DC
12 mA
4V DC max.
1V DC min.
20…280V AC/22…48V DC
20 mA
18V AC/DC
6V AC/DC
3…32V DC
12 mA
2.5V DC
1.2V DC
20…280V AC/22…48V DC
20 mA
-32V DC
6V AC/DC
4…32V DC
12 mA
3.5V DC
1.2V DC
20…280V AC/22…48V DC
20 mA
18V AC/DC
6V AC/DC
700-SH_ _ W…
Current Control
4…20 mA, - 700-SH_ _ F…
3…32V DC
12 mA
3V DC max.
1.0V DC
700-SH10J…
700-SH_ _ H…
700-SH_ _ G…
700-SH_ _ V…
(1) When specified heatsink is used.
Output Ratings Load Voltage Range
Applicable Load Current with Heat Sink [A] (2)
700-SH5FZ24
3…60V DC
0.001…5 A DC
700-SH10J…
42…265V AC
0.15…10
700-SH10H…
42…530V AC
0.15…10
700-SH25G…
24…265V AC
0.15…25
700-SH25H…
42…530V AC
0.15…25
700-SH25V…
42…660V AC
0.15…25
700-SH25W…
90…280V AC
0.15…25
700-SH50G…
24…265V AC
0.15…50
700-SH50H…
42…530V AC
0.15…50
700-SH50V…
42…660V AC
0.15…50
700-SH50W…
90…280V AC
0.15…50
700-SH75H…
42…530V AC
0.15…75
700-SH75V…
42…660V AC
0.15…75
700-SH100H…
42…530V AC
0.15…100
700-SH100V…
42…660V AC
0.15…100
Cat. No.
(2) AC unless indicated.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
237
Page 239
Relay and Timer Specifications
Characteristics Description
Cat. Nos. 700-SH10, 25, 50 (not including 700-SH_ _W)
Cat. Nos. 700-SH75, 100
Pick-up Time
1/2 of load power source cycle time(DC input) / 1 of load power source cycle time (AC input)
Drop-out Time
1/2 of load power source cycle time (DC input) / 2 of load power source cycle time (AC input)
Output ON Voltage Drop
1.6V (RMS) max.
Output Leakage Current
<3 mARMS 100 MΩ min (@ 500V DC)
Insulation Resistance
100 MΩ min. (at 500V DC)
Dielectric Strength
>4000V ACRMS
Vibration Resistance
Malfunction: 10…55 Hz, 1.5 mm double amplitude
Shock Resistance
Malfunction: 1000 m/s2 Operating: –20…+70 °C with no icing or condensation
Ambient Temperature Storage: –40…+100 °C with no icing or condensation Ambient Humidity
0…95% no condensing
Standards Compliance
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4
Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)
Weight
Approx. 60 g
Description
Approx. 100 g
Cat. No. 700-SH_ _W
Pick-up Current
4.2 mA
Drop-out Current
4.1 mA
Voltage Drop
<10V DC @ 20 mA
Leakage Current
<3 mA
Insulation Voltage
<4000 VRMS
Vibration Resistance
Malfunction: 10…55 Hz, 1.5 mm double amplitude
Shock Resistance
Malfunction: 1000 m/s2
Ambient Temperature
Operating: –20…+70 °C with no icing or condensation
Ambient Humidity
0…95% no condensing
Standards Compliance
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4
Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 24024)
Weight
Approx. 60 g
Description
Cat. No. 700-SH5FZ24
Pick-up Voltage
<3V DC
Drop-out Voltage
>1V DC
Activating Frequency
<100 Hz
Input Impedance
1 kΩ
Response Time Pick-up @ Vin > 5V
<4000 uS
Response Time Drop-out
<1 mS
On-state Voltage Drop @ Rated Current
<1.5V
238
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 240
Relay and Timer Specifications
Description
Cat. No. 700-SH5FZ24
Off-state Current Drop @ Rated Voltage
<1 mA
Insulation Voltage
<1 mA
Vibration Resistance
Malfunction: 10…55 Hz, 1.5 mm double amplitude
Shock Resistance
Malfunction: 1,000 m/s2
Ambient Temperature
Operating: –20…+70 °C with no icing or condensation
Ambient Humidity
0…95% no condensing
Standards Compliance
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN61000-6-4 cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)
Certifications Weight
Approx. 60 g
Surge Current vs. Ambient Temperature Characteristics Surge current resistivity for 700-SH50....
Surge current resistivity for 700-SH10, 25.... 700A
300A
600A
250A
500A
Inrush current (Apk)
Inrush current (Apk)
350A
200A
150A
100A
400A
300A
200A
50A
100A
0A 10ms
100ms
1000ms
0A 10ms
10000m s
Energizing time (ms)
100ms
1000ms
10000m s
Energizing time (ms)
Surge current resistivity for 700-SH75....
Surge current resistivity for 700SH100....
1200A
2000A 1800A 1000A
1600A 1400A
Inrush current (Apk)
Inrush current (Apk)
800A
600A
400A
1200A 1000A 800A 600A
200A
400A 200A
0A 10ms
100ms
1000ms
Energizing time (ms)
10000m s
0A 10ms
100ms
1000ms
10000m s
Energizing time (ms)
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
239
Page 241
Relay and Timer Specifications
Load current vs. ambient temperature characteristics for 700-SH10….
Load current vs. ambient temperature characteristics for 700-SH25…. 30
12 700-SN50VHC
10
700-SN50(V)HC
25
700-SN50HC 700-SN10
700-SN25
700-SN10
700-SN25
700-SN50
20
8 Load Current (A)
Load Current (A)
700-SN50
6
4
15
10
No heatsink
2
No heatsink
5
0
0 -20
-10
0
10
20
30
40
50
60
70
80
-20
-10
0
10
Ambient temperature (ºC)
20
30
40
50
60
70
80
Ambient temperature (ºC)
Load current vs. ambient temperature characteristics for 700-SH75….
Load current vs. ambient temperature characteristics for 700-SH50…. 80
60
700-SN50VHC
70 50
700-SN50HC 700-SN50VHC
60
700-SN10
700-SN25
700-SN50
Load Current (A)
Load Current (A)
40 700-SN50HC
30
20
50 700SN10
700-SN25
700-SN50
40
30
20 10
10
No heatsink
No heatsink
0 -20
- 10
0
10
20
30
40
50
60
70
0
80
-20
Ambient temperature (ºC)
-10
0
10
20
30
40
50
60
70
80
Ambient temperature (ºC)
Load current vs. ambient temperature characteristics for 700-SH5…..
Load current vs. ambient temperature characteristics for 700-SH100…. 120
6
100
5
700-SN50(V) HC
700-SN50
700-SN50HC
700-SN50VHC
Load Current (A)
Load Current (A)
700-SN10
700-SN25
50
60
700-SN50
4
80
60
700-SN10
700-SN25
No heatsink
3
2
40
1
20
No heatsink
0
0 -20
-10
0
10
20
30
40
50
60
70
80
-20
-10
0
240
10
20
30
40
Ambient temperature (ºC)
Ambient temperature (ºC)
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
70
80
Page 242
Relay and Timer Specifications
Mounting Considerations (1) (2) (3) (4) All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing purposes.
24.5
30.0
45.5
Mounting Holes (Bottom View) 5.3
Load
2 x M5 Screws
47.5
Two Ø 4.4 or M4 Holes
2 x M3 Screws
Load Power Supply
Load T1
L1
A2
47.5
58.2
Terminal Arrangement/ Internal Connections (Top View)
Input
A1
13.0 25 45.5
Cat. No. 700-SH5F…
28.8
44.8
Two Ø 4.4 or M4 Holes 12.3 2 X M5 Screws
8.6
47.5
58.2
Operating Indicator
APPLY HEATSINK COMPOUND
47.5
2 X M3 Screws
5.2 5.25 25 45.5
Cat. No. 700-SH10, -SH25, -SH50, -SH75, -SH100
(1) The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular to the floor, a 30% current derating is required. (2) When attaching a heat sink to 700-SH, apply a thin layer of heat conductive grease (approximately 0.002 in. thick) on the heat sink to maximize heat transfer between the SSR and the heat sink. Recommended types: Silicon based, Dow Corning 340, Toshiba YG6240; Non-silicon based, AOS company type 53300 (Cat. No. 46801-010-01). (3) Tighten the SSR panel/heat sink mounting screws to a torque of 0.78…0.98 N•m (6.9…8.7 lb•in). (4) Tighten the SSR terminal wiring screws as follows M4: 0.98…1.37 N•m (8.67…12.12 lb•in), M5: 1.57…2.35 N•m (13.89…20.8 lb•in).
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
241
Page 243
Relay and Timer Specifications
700-SN10
700-SN25
700-SN50
700-SN50HC
700-SN50VHC
12
47
27
45
67
27,5
28,5
Cat. No.700-SHTRMA
242
Cat. No. 700-SHCOV