Page 236

Relay and Timer Specifications

700-SH Hockey Puck Relays • 100 A max. continuous load (output) current with appropriate heat sink • 264V AC, 530V AC, or 660V AC max. load voltage options • 3…32V DC, 4…32V DC, 80…130V AC, 200…260V AC, 20…280V AC/22…48V DC control (input) voltage options • LED indicator for input/logic ON/OFF status monitoring • Protective cover for added safety

Photo

Input-toOutput Isolation Method

Zero Cross Function

Yes

Status Indicator

Yes

Output (Load) Max. Continuous Current and Rated Voltage Range (1)

Rated Input Control Voltage

Cat. No.(2)

10 A @ 42…265V AC

3…32V DC

700-SH10JZ24

10 A @ 42…265V AC

80…130V AC

700-SH10JA12

10 A @ 42…265V AC

200…260V AC

700-SH10JA22

10 A @ 42…530V AC

4…32V DC

700-SH10HZ25 (Series B)

25 A @ 42…530V AC

4…32V DC

700-SH25HZ25 (Series B)

25 A @ 24…265V AC

3…32V DC

700-SH25GZ24

25 A @ 24…265V AC

20…280V AC/ 22…48V DC

700-SH25GA24

50 A @ 24…265V AC

3…32V DC

700-SH50GZ24

50 A @ 24…265V AC

20…280V AC/ 22…48V DC

700-SH50GA24

50 A @ 42…530V AC

4…32V DC

700-SH50HZ25

25 A @ 42…660V AC

4…32V DC

700-SH25VZ25

25 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH25VA24

50 A @ 42…660V AC

4…32V DC

700-SH50VZ25

50 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH50VA24

75 A @ 42…530V AC

4…32V DC

700-SH75HZ25

75 A @ 42…660V AC

4…32V DC

700-SH75VZ25

75 A @ 42…530V AC

20…280V AC/ 22…48V DC

700-SH75HA24

75 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH75VA24

100 A @ 42…530V AC

4…32V DC

700-SH100HZ25

100 A @ 42…530V AC

20…280V AC/ 22…48V DC

700-SH100HA24

100 A @ 42…660V AC

4…32V DC

700-SH100VZ25

100 A @ 42…660V AC

20…280V AC/ 22…48V DC

700-SH100VA24

5 A @ 3...60V DC

3…32V DC

700-SH5FZ24

25 A @ 90…280V AC

4…20 mA DC

700-SH25WA25

50 A @ 90…280V AC

4…20 mA DC

700-SH50WA25

Optocoupler

Yes

No

Yes

Yes

(1) When used with heat sink. (2) All catalog numbers are Series A unless noted.

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

235

Page 237

Relay and Timer Specifications

Accessories - 700-SH Relays Photo

236

Description

Pkg. Quantity

Cat. No.

Heat Sink - Panel or DIN Rail Mount

1

700-SN10

Heat Sink - Panel or DIN Rail Mount

1

700-SN25

Heat Sink - Panel or DIN Rail Mount

1

700-SN50

Heat Sink - Panel or DIN Rail Mount

1

700-SN50HC

Heat Sink - Panel or DIN Rail Mount

1

700-SN50VHC

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

Thermal Conductive Pads

50

700-SHCPAD

Plastic Covers, for DC output version

25

700-SHCOV

Thermal Adapters - for 100 A Wire

10

700-SHTRMA

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 238

Relay and Timer Specifications

Specifications- 700-SH Relays Control/Input Ratings Cat. No.

Operating Voltage

Input Current @ Max. Voltage

Voltage Level Pickup Voltage

Drop-out Voltage

3…32V DC

12 mA

2.75V DC max.

1.2V DC min.

80…130V AC

13 mA

70V AC max.

30V AC min. (1)

200...280V AC

13 mA

190V AC max.

90V AC min.

4…32V DC

12 mA

4V DC max.

1V DC min.

20…280V AC/22…48V DC

20 mA

18V AC/DC

6V AC/DC

3…32V DC

12 mA

2.5V DC

1.2V DC

20…280V AC/22…48V DC

20 mA

-32V DC

6V AC/DC

4…32V DC

12 mA

3.5V DC

1.2V DC

20…280V AC/22…48V DC

20 mA

18V AC/DC

6V AC/DC

700-SH_ _ W…

Current Control

4…20 mA, - 700-SH_ _ F…

3…32V DC

12 mA

3V DC max.

1.0V DC

700-SH10J…

700-SH_ _ H…

700-SH_ _ G…

700-SH_ _ V…

(1) When specified heatsink is used.

Output Ratings Load Voltage Range

Applicable Load Current with Heat Sink [A] (2)

700-SH5FZ24

3…60V DC

0.001…5 A DC

700-SH10J…

42…265V AC

0.15…10

700-SH10H…

42…530V AC

0.15…10

700-SH25G…

24…265V AC

0.15…25

700-SH25H…

42…530V AC

0.15…25

700-SH25V…

42…660V AC

0.15…25

700-SH25W…

90…280V AC

0.15…25

700-SH50G…

24…265V AC

0.15…50

700-SH50H…

42…530V AC

0.15…50

700-SH50V…

42…660V AC

0.15…50

700-SH50W…

90…280V AC

0.15…50

700-SH75H…

42…530V AC

0.15…75

700-SH75V…

42…660V AC

0.15…75

700-SH100H…

42…530V AC

0.15…100

700-SH100V…

42…660V AC

0.15…100

Cat. No.

(2) AC unless indicated.

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

237

Page 239

Relay and Timer Specifications

Characteristics Description

Cat. Nos. 700-SH10, 25, 50 (not including 700-SH_ _W)

Cat. Nos. 700-SH75, 100

Pick-up Time

1/2 of load power source cycle time(DC input) / 1 of load power source cycle time (AC input)

Drop-out Time

1/2 of load power source cycle time (DC input) / 2 of load power source cycle time (AC input)

Output ON Voltage Drop

1.6V (RMS) max.

Output Leakage Current

<3 mARMS 100 MΩ min (@ 500V DC)

Insulation Resistance

100 MΩ min. (at 500V DC)

Dielectric Strength

>4000V ACRMS

Vibration Resistance

Malfunction: 10…55 Hz, 1.5 mm double amplitude

Shock Resistance

Malfunction: 1000 m/s2 Operating: –20…+70 °C with no icing or condensation

Ambient Temperature Storage: –40…+100 °C with no icing or condensation Ambient Humidity

0…95% no condensing

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4

Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)

Weight

Approx. 60 g

Description

Approx. 100 g

Cat. No. 700-SH_ _W

Pick-up Current

4.2 mA

Drop-out Current

4.1 mA

Voltage Drop

<10V DC @ 20 mA

Leakage Current

<3 mA

Insulation Voltage

<4000 VRMS

Vibration Resistance

Malfunction: 10…55 Hz, 1.5 mm double amplitude

Shock Resistance

Malfunction: 1000 m/s2

Ambient Temperature

Operating: –20…+70 °C with no icing or condensation

Ambient Humidity

0…95% no condensing

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4

Certifications cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 24024)

Weight

Approx. 60 g

Description

Cat. No. 700-SH5FZ24

Pick-up Voltage

<3V DC

Drop-out Voltage

>1V DC

Activating Frequency

<100 Hz

Input Impedance

1 kΩ

Response Time Pick-up @ Vin > 5V

<4000 uS

Response Time Drop-out

<1 mS

On-state Voltage Drop @ Rated Current

<1.5V

238

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 240

Relay and Timer Specifications

Description

Cat. No. 700-SH5FZ24

Off-state Current Drop @ Rated Voltage

<1 mA

Insulation Voltage

<1 mA

Vibration Resistance

Malfunction: 10…55 Hz, 1.5 mm double amplitude

Shock Resistance

Malfunction: 1,000 m/s2

Ambient Temperature

Operating: –20…+70 °C with no icing or condensation

Ambient Humidity

0…95% no condensing

Standards Compliance

UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN61000-6-4 cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)

Certifications Weight

Approx. 60 g

Surge Current vs. Ambient Temperature Characteristics Surge current resistivity for 700-SH50....

Surge current resistivity for 700-SH10, 25.... 700A

300A

600A

250A

500A

Inrush current (Apk)

Inrush current (Apk)

350A

200A

150A

100A

400A

300A

200A

50A

100A

0A 10ms

100ms

1000ms

0A 10ms

10000m s

Energizing time (ms)

100ms

1000ms

10000m s

Energizing time (ms)

Surge current resistivity for 700-SH75....

Surge current resistivity for 700SH100....

1200A

2000A 1800A 1000A

1600A 1400A

Inrush current (Apk)

Inrush current (Apk)

800A

600A

400A

1200A 1000A 800A 600A

200A

400A 200A

0A 10ms

100ms

1000ms

Energizing time (ms)

10000m s

0A 10ms

100ms

1000ms

10000m s

Energizing time (ms)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

239

Page 241

Relay and Timer Specifications

Load current vs. ambient temperature characteristics for 700-SH10….

Load current vs. ambient temperature characteristics for 700-SH25…. 30

12 700-SN50VHC

10

700-SN50(V)HC

25

700-SN50HC 700-SN10

700-SN25

700-SN10

700-SN25

700-SN50

20

8 Load Current (A)

Load Current (A)

700-SN50

6

4

15

10

No heatsink

2

No heatsink

5

0

0 -20

-10

0

10

20

30

40

50

60

70

80

-20

-10

0

10

Ambient temperature (ºC)

20

30

40

50

60

70

80

Ambient temperature (ºC)

Load current vs. ambient temperature characteristics for 700-SH75….

Load current vs. ambient temperature characteristics for 700-SH50…. 80

60

700-SN50VHC

70 50

700-SN50HC 700-SN50VHC

60

700-SN10

700-SN25

700-SN50

Load Current (A)

Load Current (A)

40 700-SN50HC

30

20

50 700SN10

700-SN25

700-SN50

40

30

20 10

10

No heatsink

No heatsink

0 -20

- 10

0

10

20

30

40

50

60

70

0

80

-20

Ambient temperature (ºC)

-10

0

10

20

30

40

50

60

70

80

Ambient temperature (ºC)

Load current vs. ambient temperature characteristics for 700-SH5…..

Load current vs. ambient temperature characteristics for 700-SH100…. 120

6

100

5

700-SN50(V) HC

700-SN50

700-SN50HC

700-SN50VHC

Load Current (A)

Load Current (A)

700-SN10

700-SN25

50

60

700-SN50

4

80

60

700-SN10

700-SN25

No heatsink

3

2

40

1

20

No heatsink

0

0 -20

-10

0

10

20

30

40

50

60

70

80

-20

-10

0

240

10

20

30

40

Ambient temperature (ºC)

Ambient temperature (ºC)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

70

80

Page 242

Relay and Timer Specifications

Mounting Considerations (1) (2) (3) (4) All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing purposes.

24.5

30.0

45.5

Mounting Holes (Bottom View) 5.3

Load

2 x M5 Screws

47.5

Two Ø 4.4 or M4 Holes

2 x M3 Screws

Load Power Supply

Load T1

L1

A2

47.5

58.2

Terminal Arrangement/ Internal Connections (Top View)

Input

A1

13.0 25 45.5

Cat. No. 700-SH5F…

28.8

44.8

Two Ø 4.4 or M4 Holes 12.3 2 X M5 Screws

8.6

47.5

58.2

Operating Indicator

APPLY HEATSINK COMPOUND

47.5

2 X M3 Screws

5.2 5.25 25 45.5

Cat. No. 700-SH10, -SH25, -SH50, -SH75, -SH100

(1) The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular to the floor, a 30% current derating is required. (2) When attaching a heat sink to 700-SH, apply a thin layer of heat conductive grease (approximately 0.002 in. thick) on the heat sink to maximize heat transfer between the SSR and the heat sink. Recommended types: Silicon based, Dow Corning 340, Toshiba YG6240; Non-silicon based, AOS company type 53300 (Cat. No. 46801-010-01). (3) Tighten the SSR panel/heat sink mounting screws to a torque of 0.78…0.98 N•m (6.9…8.7 lb•in). (4) Tighten the SSR terminal wiring screws as follows M4: 0.98…1.37 N•m (8.67…12.12 lb•in), M5: 1.57…2.35 N•m (13.89…20.8 lb•in).

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

241

Page 243

Relay and Timer Specifications

700-SN10

700-SN25

700-SN50

700-SN50HC

700-SN50VHC

12

47

27

45

67

27,5

28,5

Cat. No.700-SHTRMA

242