Page 163

FieldBus FB Node Address FB Node Address is the network ID number used in the FieldBus system. You can set the Node address if the selected FieldBus type have this feature. Two units in the same FieldBus network cannot have the same node address. See the specific bus type pages for possible settings. Baud Rate Baud rate is the communication speed on the FieldBus system. You can set the baud rate if the selected FieldBus types have this feature. See the specific bus type pages for possible settings. Note! The Baudrate shall be the same in all Power Focus units and in the PLC.

Set source address from ModbusPlus global data exchanges require a source address, which is a node address where you want to get the global data from. There are two choices, software or hardware. Selecting “software” allows you to program Source Address from the user interface. Selecting “hardware” allows you to configure Source Address using the switches on the FieldBus card. See the specific bus type pages for possible settings. Source address Source address is the network ID number used in the FieldBus system. You can set the Source address if you want to get global data from that address. See the specific bus type pages for possible settings. Connection Mode Connection Mode manages the way the FieldBus system detects changes of data on the different units. Some FieldBus types have the possibility to set different connection modes. See the specific bus type pages for possible settings. Note! The setting in Power Focus 3000 and the PLC must be the same.

163

Page 164

FieldBus PCP length PCP (Peripherals Communication Protocol) length is a way to send longer data strings than the standard 20 bytes process data. The data package that is sent to or from the Power Focus 3000 can be longer than the 20 bytes process data. The part exceeding the process data is sent in small packages. The PCP length defines the package length. PCP data has lower priority then the process data. Available selections are 0, 1, 2, and 4. These numbers are the lengths in words. 0 = no PCP. Note! You have to restart the Power Focus 3000 when the PCP length is changed. The length must be the same in the PLC. Process DataLength Process DataLength is the first part of the InterBus message. The length has to be same for both input and output data. Maximum Process DataLength is 20 bytes minus the PCP length in bytes. This means that the highest Process string length is 20 bytes if PCP is zero. Note! You must restart Power Focus 3000 when the Process DataLength is changed. The length must be the same in the PLC. From PF Global DataLength From PF Global DataLength is the length of sending broadcast data to the network. This is a special function for ModbusPlus, not available for other FieldBus type. Max length = 64 bytes. If only point-to-point data is transferred, set this parameter to zero. Note! From PF Datalength – From PF Global Datalength = From PF point-to-point DataLength. To PF Global DataLength To PF Global DataLength is the length of receiving broadcast data from the network. This is a special function for ModbusPlus, not available for other FieldBus type. Max length = 64 bytes. If only point-to-point data is received, set this parameter to zero. Note! To PF Datalength – To PF Global Datalength = To PF point-to-point DataLength. Bitmap Select Via this parameter you can select the way you want to present the bit map. It defines if byte 0 or byte 1 shall be to the le ft. This makes it possible to view the bitmap in the same way in Power Focus 3000 and the PLC configuration software. This parameter is default set to the type that is common for the selected FieldBus type.

164

Page 165

FieldBus

14.1.2 Keys Clear FieldBus in PF This key is used to erase the FieldBus configuration in Power Focus 3000 (i.e. when you want to remove the FieldBus card). It is not necessary to clear the FieldBus configuration to change the configuration. If the FieldBus configuration is cleared the FieldBus type will be set to none. When the clear key is pressed the configuration in Power Focus 3000 is deleted but then you can still see the configuration in ToolsTalk FieldBus window. When you press the read key, the window will be updated. Monitor Mode This key is used to monitor FieldBus data communication for testing purpose. This function works only when ToolsTalk is online (connected to the Power Focus 3000). When monitor mode is active, the data from Power Focus 3000 to PLC are visible in the From PF window bitmap. The data from PLC to Power Focus 3000 are visible in the To PF window bitmap. It is not possible to change and store FieldBus configuration in monitor mode. Data can be displayed in two formats, defined data type format and binary format. The data in the monitor windows are updated at a rate of 3 messages/second. Get FieldBus Info When this key is pushed FieldBus module type, module firmware version, and module serial number are displayed.

14.1.3 Other functions Store to and Read from a file Store and read FieldBus Configurations to file. Use the Read/Save FieldBus functions in the File menu in ToolsTalk. To store to or read from a file you must first activate the FieldBus window. The FieldBus file extension is *.pff

165

Page 166

FieldBus

14.1.4 From/To PF Setup In this window you configure the bitmap that is sent out from the Power Focus 3000 (From PF Setup) and sent in to the Power Focus 3000 (To PF Setup).

Add item When the Add item button is clicked, a selection list is activated. On the right side of the item list, see information about highlighted item. Click Hide details button if you do not need this help text. Highlight the item you want and double click on it or click the Add item button. The item will then be entered to the item list on the first available line. In the list you can see start word, start byte and start bit for the selected item. The start word, byte and bit give the start position of an item in the bitmap. The length is also possible to see and sometimes change. If this does not match the wanted bitmap it is easy to change the length and position in the bitmap by changing the start positions in the item list. Change one line at the time and then press Enter key on the PC after each line is changed. It is also possible to drag and drop directly in the bitmap. In this case, the start positions in the Item list are updated automatically.

166

Page 167

FieldBus If the bitmapping is changed so that a mapping conflict occurs, this part is marked with red colour in the bitmap. The max number of selected items is 60 in From PF set- up and 60 in to PF set- up. Delete item To delete an item, highlight it in the Item list and click the Delete item button. For detailed information about all possible selections see Appendix D.

167

Page 168

This page is a scan with no text; see it in the PDF.

Page 169

DS Tools

15

DS Tools

The DS control strategy makes it possible to run Tensor DS tools on the Power Focus 3000 controller. This way you can have the same controller for both Tensor S and Tensor DS tools. Note that the DS control strategy is not possible to run with Tensor S tools. The Tensor DS tool has no transducer. Instead of ha ving an electrical signal from a strain gauge, the DS tool derives the torque from different relevant parameters, such as voltage, speed, temperature and current. The Tensor DS is proven to achieve excellent repeatability. However, the operating range of the Tensor DS is smaller than that of the Tensor S and you might need to adjust the torque measurement for each Pset and joint for better torque accuracy. The DS Torque tuning factor, P245, adjusts the torque measurement for each combination of Pset and joint. The lack of a transducer also decreases the number of Tensor S features available in DS control. IMPORTANT When programming a DS control strategy, it is of greatest importance to have a welldeveloped second stage. The fastener/socket should allow some angle rotation in the second stage of the tightening, or else the torque may overshoot. The best way to determine this is simply by observing the angle rotation during the second stage. If the tool overshoots a red toggling led will show on the tool. The criteria for high torque is a short or a non-existing second stage in combination with a high speed in the first stage. On the display the error massage E003 will be shown.

15.1

Adjusting DS Torque tuning factor

Torque tuning is performed either from the Graph interface, ToolsTalk or automatically with an ACTA 3000. It allows an easy adjustment to your reference system torque values (e.g. an ACTA 3000) and compensates for tool-drive-programming and joint variations. One torquetuning factor is stored with each Pset. Tools Talk and Graph This is how to calculate a new torque tuning value when a tool is controlled against an external torque reference for calibration. There is one torque-tuning factor for each Pset. 1. Perform a number of tightenings with the external torque gauge connected, preferably 20 tightenings or more to achieve a good mean value. 2. Calculate the mean value from the tightenings.

169

Page 170

DS Tools 3. Divide the desired target value with the calculated mean value and multiply by one hundred. This is the new DS Torque tuning factor. New Torque Tuning Factor =

Final Target Old Torque Tuning Factor × × 100 Measured Mean 100

4. Enter and store the new DS Torque tuning factor. 5. Perform another set of tightenings to control your torque. 6. If the torque is OK you are ready to run, if not, do the complete procedure over again. ACTA 1. Connect the ACTA and Power Focus 3000 via RS232 cable. 2. Make sure the ACTA is set to communicate with controller. Select: Com - Controller 3. Synchronise the ACTA and Power Focus 3000. Select: Q.Prog - Synchronise - PF3000 4. Clear the ACTA database. Select: Datab - Clear all measurement 5. Perform a number of tightenings with the ACTA connected, preferably 20 tightenings or more so that a good mean value can be achieved. 6. Calibrate the tool. Select: Config - Calibration - Tool 7. Perform another set of tightenings to control your torque. If the torque is OK you are ready to run, if not, do the complete procedure over again. See chapter 21, Appendix A: QUICK Reference Guide, for DS Tools control strategies.

170

Page 171

Open End Tools

16

Open End Tools

A Tensor S tool with an Open End head.

An Open End tool, or Tube Nut tool, is used to tighten nuts on tubes and similar. The basic Open End behaviour is that the tool will alternate between tightening and opening every second time you press the start trigger. Opening means that the tool head goes back to open position to make it possible to remove the tool from the nut on the tube. Before using an Open End tool, make sure that the tool has been assembled and configured correctly. If not, the tool can run in wrong direction and the mechanical stop in the Open End head may be damaged.

16.1

Using an Open End Tool

The operation of an Open End tool differs somewhat from normal tools. When the Power Focus 3000 is powered up with a configured Open End tool attached, the tool will run the Open End head to its open position when the tool trigger is pressed for the first time. After that, the tool will alternate between tightening and opening when you press the start trigger. When a tightening is finished, OK or NOK, the tool will run the Open End head to its open position the next time you press the start trigger. If the tool is stopped before the Open End head is fully open the next start of the tool will complete the opening. When the tool is opened a tightening is done the next time that the tool trigger is pressed. The tool direction ring does not have any effect on the tightening direction. The tightening direction is set by the Open End configuration parameters in the Power Focus 3000 diagnostics. The Tool tightening direction, P240, option in Pset programming has no effect and is replaced by the Open End tightening direction, D122, option in the Power Focus 3000 diagnostics. These settings are stored in the tool memory. Therefore you only need to configure each Open End tool once.

171

Page 172

Open End Tools The Reverse angle and Rotate spindle forward/reverse tightening strategies cannot be used with Open End tools. Further more is it not possible to use Open End tools in a Multistage configuration. When you purchase an Open End tool from Atlas Copco it is already pre-configured. The following chapter, Configuring an Open End Tool, describes how to configure an Open End tool. Note! It is very important that the configuration is done correctly. Otherwise the Open End head may be damaged.

16.2

Configuring an Open End Tool

Use the settings under Tool Configuration - Open End parameters in Diagnostics to configure the tool when fitting an Open End head. Fitting an Open End head to the tool will change the way it operates. It is very important to understand those changes when building and using an Open End tool. If you do not, the tool can run in wrong direction and the mechanical stop in the Open End head may be damaged. The Open End head will effect the gear ratio of the tool. For that reason it is necessary to perform an Open End tuning whe n a new Open End head has been assembled. The Open End tuning command measures the total gear ratio and writes the new value to the tool memory. This is necessary to get the torque and angle measurement correct. Also make sure to set-up the rotation change option and tightening direction correctly. Note! It is not possible to restore the tool memory if the Open End head is removed without using special tool programmer.

16.2.1 Open End Parameters Use Open End If the tool is built as an Open End tool, i.e. if an Open End head is fitted to the tool, this option shall be checked. When this parameter is checked the other Open End parameters become available. Inverted motor rotation If an Open End head is used that changes the rotation direction on the spindle, this option shall be checked. In other words, the Inverted motor rotation, D121, option is used to maintain ordinary rotational direction of the spindle.

172