Page 183

Parameter List P2xx Programming + P20x

Current monitoring

Measures max compensated torque forming current during tightening as percentage of tool max torque.

P200

Current monitoring

Activates the function. The default value is NO.

P201

CM min

Defines min limit for OK tightening.

P201

CM max

Defines max limit for OK tightening.

P21x

PVT self-tap

This function makes it possible to tighten bolted joints where the torque during tightening is higher than the final target. For example, this may be the case when tightening self- tapping.

P210

Self- tap

Activates the function. The default value is NO.

P211

Self- tap interval

Defines the section where measuring is performed. Setting is performed in degrees in the interval 1 – 9999. Default value is 1.

P212

No. of self- tap windows

P213

Self- tap min

P214

Self- tap max

P22x

PVT monitoring

Defines the number of windows that the Self- tap interval [P211] is to be divided into. Each window is then evaluated separately. The number of windows can be chosen between 1 – 9999. Default value is 1. This parameter indicates the lowest torque level for the interval. If the torque level falls below this level, a low- level alarm will be generated. Range is from cycle complete value to self-tap max. Default value is cycle complete. This parameter indicates the highest torque level for the interval. If the torque level exceeds this level, a high level alarm will be generated. Range is from self- tap min to Tool max torque. Default value is tool max torque that means this parameter must be actively changed. Measures PVT during on going tightening.

P220

PVT monitoring

Activates the function. The default value is NO.

183

Page 184

Parameter List P221

P222

PVT delay interval

Defines delay before PVT monitoring starts.

PVT monitor interval

Setting is performed in degrees in the interval 0 – 9999. Default value is 0 degrees. Defines the interval during which the PVT monitoring is to be performed.

P223

No. of PVT windows

P224

PVT min limit

P225

PVT max limit

P23x

PVT compensate

Setting is performed in degrees in the interval 1 – 9999. Default value is 1. Defines the number of windows that the interval should be divided into. Each window is then evaluated separately. The number of windows can be chosen between 1 – 9999. Default value is 1. The PVT min value is evaluated against the monitor interval peak value at the end of the interval. If the torque value falls below this limit, an alarm is generated. Default value is cycle complete value. PVT max is monitored in real- time during the monitor interval and if exceeded, an alarm is generated. Default value is rundown complete value. The PVT compensate value is used as a base reference for the torque used during tightening. This means that each registered torque value is added to the PVT value before it is compared to the programmed torque values. The different values for torque, for example, Final target and First target for 1 st stage, are compensated with the PVT value. Also, the results are compensated.

P230

PVT compensate

Activates the function. The default value is NO. When PVT compensate is set to Yes, a prevailing torque PVT comp, measured at the interval of 20 samples preceding start of PVT comp point is used as the reference for the torque used during the actual tightening cycle. Any torque result is compensated (subtracted) with the prevailing value.

P231

184

PVT comp point

The value can be set between (0 – 9999) degrees. Default value is 10 degrees.

Page 185

Parameter List P24x

Options

P240

Tool tightening direction

P241

Soft stop

Select tool rotation direction. CW for right hand threaded screws and CCW for left hand threaded screws. To be able to start in the correct direction you must turn the tool direction ring to its correct position. This parameter has no effect when running an Open End tool (Tube Nut tool). Yes/No Reduces tool speed at the end of a tightening cycle. Yes is recommended.

P242

Alarm on Re-hit

Yes/No If selected, Power Focus 3000 will detect re-hits, error code E112. The red tool LED will be lit when a re-hit is detected. The criteria for a re- hit are a short or a non-existent second stage in combination with a slow speed in the first stage. Default is No.

P243

P244

Alarm on Tq < target

Yes/No

Alarm on Lost trigger

Yes/No

Decides if the tightening should be approved if the torque is lower than the final target. Default is No.

Decides if a lost tool trigger should abort the tightening. Default is No. P245

DS torque tuning factor

Only used if DS con is chosen as control strategy [P101]. It compensates for the error that DS measurement induces. The value can be set between 80% and 220%. Default value is 100%.

P4xx

Pset set-up

P40x

Pset admin

P402

Name Pset

Name the Pset. Up to 25 characters. Default value is empty.

P406

Pset updated

Timestamp (date and time) for Pset latest modification. Not editable.

- View existing Pset - Create New Pset - Copy Pset - Delete Pset

185

Page 186

Parameter List P5xx

Statistic programming

P50x

Statistic common parameters

P500

Min valid stat tq limit

The result must be greater than or equal to this limit value in order for it to be included in the statistical calculations.

P501

Max valid stat tq limit

The result must be less than or equal to this limit value in order for it to be included in the statistical calculations.

P502

Subgroup size

Defines the subgroup size for statistical diagrams and control limits. If this parameter is changed, the results will be recalculated.

P503

No of subgroups

Group size can be set between 2 – 20. Power Focus can automatically calculate statistical control limits. In order for these limits to be reasonable, they must be performed on a greater number of tightenings. This parameter is used to set the number of subgroups used for these calculations.

The following Pset parameters are statistical control limits. They can be entered manually or be calculated automatically by Power Focus 3000. P504

Subgroup frequency Defines the number of tightening results that are used for one of the statistics calculations.

P505

Latest n values

The latest number of values, 0 – 100.

P506

SPC alarm tq

With this parameter it is possible to switch on or off the torque SPC alarm function.

P507

SPC alarm Angle

With this parameter it is possible to switch on or off the angle SPC alarm functio n.

P508

SPC alarm CM

With this parameter it is possible to switch on or off the current SPC monitoring alarm function.

P51x

SPC torque

Statistic Process Control for torque.

P510

Torque X-bar LCL

The lower control limit for mean value. Calculated automatically or entered manually.

186

Page 187

Parameter List P511

Torque X-bar UCL

The upper control limit for mean value.

P512

Torque range LCL

Calculated automatically or entered manually. The lower control limit for range. Calculated automatically or entered manually.

P513

Torque range UCL

The upper control limit for range. Calculated automatically or entered manually.

P514

Torque X-bar-bar

The mean value for calculated mean values for groups of tightenings.

P515

Torque range-bar

The mean value for calculated mean ranges for groups of tightenings.

P52x

SPC angle

Statistic Process Control for angle.

P520

Angle X-bar LCL

The lower control limit for mean value. Calculated automatically or entered manually.

P521

Angle X-bar UCL

The upper control limit for mean value. Calculated automatically or entered manually.

P522

Angle range LCL

The lower control limit for range. Calculated automatically or entered manually.

P522

Angle range UCL

The upper control limit for range. Calculated automatically or entered manually.

P524

Angle X-bar-bar

The mean value for calculated mean values for groups of tightenings.

P525

Angle range-bar

The mean value for calculated mean ranges for groups of tightenings.

P53x

SPC Rundown Angle

Statistic Process Control for rundown angle. (Only active if Rundown angle is chosen [P04]).

P530

Rundown X-bar LCL

The lower control limit for mean value. Calculated automatically or entered manually.

187

Page 188

Parameter List P531

Rundown X-bar UCL

P532

Rundown range LCL

P532

P534 P535 P54x P540

Rundown range UCL

The upper control limit for mean value. Calculated automatically or entered manually. The lower control limit for range. Calculated automatically or entered manually. The upper control limit for range. Calculated automatically or entered manually.

Rundown X-bar-bar The mean value for calculated mean values for groups of tightenings. Rundown range-bar The mean value for calculated mean ranges for groups of tightenings. SPC Self-tap

Statistic Process Control for self-tap. (Only active if PVT Self-tap is selected [210]). Self- tap X-bar LCL The lower control limit for mean value. Calculated automatically or entered manually.

P541

Self- tap X-bar UCL The upper control limit for mean value. Calculated automatically or entered manually.

P542

Self- tap range LCL

The lower control limit for range. Calculated automatically or entered manually.

P542

Self- tap range UCL The upper control limit for range. Calculated automatically or entered manually.

P544

Self- tap X-bar-bar

The mean value for calculated mean values for groups of tightenings.

P545

Self- tap range-bar

The mean value for calculated mean ranges for groups of tightenings.

P55x

SPC PVT

P550

PVT X-bar LCL

Statistic Process Control for prevailing torque. (Only active if PVT monitoring is chosen [220]). The lower control limit for mean value.

P551

PVT X-bar UCL

The upper control limit for mean value.

P552

PVT range LCL

The lower control limit for range.

188

Page 189

Parameter List P552

PVT range UCL

The upper control limit for range.

P554

PVT X-bar-bar

The mean value for calculated mean values for groups of tightenings.

P555

PVT range-bar

The mean value for calculated mean ranges for groups of tightenings.

P56x P560

SPC CM parameters CM (X-bar) LCL

P561

CM (X-bar) UCL

P562

CM R LCL

P563

CM R UCL

P564

CM (X bar)

P565

CM (R bar)

Defines the low limit for the permitted values to be in the x-bar calculations. Defines the high limit for the permitted values to be in the x-bar calculations. Defines the low limit for permitted variations in the range calculations. Defines the high limit for permitted variations in the range calculations. Defines the wanted CM average for all of the subgroups. (In each subgroup the average tightened CM value is calculated. Then an average is calculated based on all of the averages.) Defines the desired average of the CM variation for all of the subgroups. (In each subgroup the average tightened CM variation is calculated. Then an average is calculated based on all of the averages.)

189

Page 190

Parameter List Multistage M20x Multistage result properties M200 Name

Specifies the name of the opened Multistage.

M201 Stage list

Stage list specifies the list of available Psets, input by the operator, that can be linked together into a Multistage. Executes the specified link list of Psets into a Multistage

M202 Batch count

Activates a function that measures how many times a multistage tightening is repeated. It must be determined from where the Batch size value should be read, if the Batch count is activated Off: Batch count is not used. Pset: Use Psets Batch size. FieldBus: An external source decides Batch size via FieldBus. Ethernet/Serial: An external source sets Batch size via Ethernet or serial interface.

M203 Batch size

The Batch size specifies the number of Multistage tightenings in a batch. The range is 0-99.

M204 Lock at batch OK

When Lock at batch is set to yes, the tool is disabled until next Pset/Multistage is selected.

M205 Stop between stages When Stop between stages is set to yes, tightening has an idle time between two consecutive stages. The idle time is specified in Tool idle time. M206 Loosening on NOK If the status of the Multistage tightening is NOK and Loosening on NOK is asserted, the tool runs in reverse direction to loosen the joint. M210 Torque result

Specifies after which of the stages the final torque result shall be displayed. Default is last stage.

M211 Angle result

Specifies after which of the stages the final angle result shall be displayed. Default is last stage.

M212 Rundown result

Specifies after which of the stages the final rundown angle result shall be displayed. Default is last stage.

190

Page 191

Parameter List M213 Self- tap result M214 PVT result

Specifies after which of the stages the final prevailing torque self-tap result shall be displayed. Default is last stage. Specifies after which of the stages the final prevailing torque monitoring result shall be displayed. Default is last stage.

M215 CM result

Specifies after which of the stages the current monitoring result shall be displayed. Default is last stage.

M216 Trace

Specifies the point at which of the stages the graph results (trace diagram) are to be displayed. Default is last stage.

M22x Statistic common M220 Min valid stat tq limit

0 Nm – 9999 Nm

M221 Max valid stat tq limit

0 Nm – 9999 Nm

M222 Subgroup size

1 – 20

The result must be greater than or equal to this value to be included in the statistical calculations.

The result must be less than or equal to this value to be included in the statistical calculations.

Defines the size of the subgroup that forms the basis for the statistical charts and control limits.

M223 No of subgroups

If this parameter is changed, all the results have to be recalculated or deleted. 1 – 7500 Power Focus calculates control limits on request. For these limits to be relevant they must be based on a large number of data, at least 100. This parameter defines when enough results are collected. If this parameter is changed, all the results have to be recalculated or deleted.

M224 Subgroup frequency 1 – 7500 This parameter measures and stores a subgroup with a given range. It also indicates the number of subgroups that are disregarded between every stored subgroup.

191

Page 192

Parameter List M225 Latest n values

1 – 100

M226 SPC alarm tq

The number of tightening values which are included in statistical calculations. On/Off This parameter switch the torque SPC alarm function on or off.

M227 SPC alarm angle

On/Off This parameter switch the angle SPC alarm function on or off.

M228 SPC alarm CM

On/Off This parameter switch the current monitoring SPC alarm function on or off.

192