Page 193
Parameter List
18.2
Job
J200
Name
J201
Forced Job
J202
Job list / Edit Job
The name of the Job helps the operator to identify the different Jobs (Maximum 25 characters). When selecting “Forced job”, the included Psets are performed in the listed order. This parameter defines which Psets are included in a Job. Selected Psets must be available. Enable: When Forced order is selected the tightenings must be performed in the order specified in the Job list. Disable: If Forced order is not selected the tightening can be performed in any order (free order).
J203
Maxtime for first tightening
Specifies the time limit allowed from when the Job is selected until the first tightening is performed. If the time limit is exceeded the Job is aborted. This value is adjustable between 0 s – 9999 s, where 0 means no timer and is the default value.
J204
Maxtime complete Job
Specifies the time limit allowed from when the Job is selected until the Job is completed. If the time limit is exceeded the Job is aborted. This value is adjustable between 0 s – 9999 s, where 0 means no timer and is the default value.
J205
Batch count type
OK (default): Specifies that only accepted tightenings will be considered performed and counted. OK+NOK: Specifies that also not accepted tightenings will be considered performed and counted.
J206
Lock at Job done
This parameter determines whether the tools shall continue to be operative following an approved (OK) Job. Enable: The tool will be disabled after the Job is performed. Disable: The tool will not be disabled after the Job is performed.
193
Page 194
Parameter List J207
Use line control
Line Control related inputs and outputs have only effect on a Job reference. A Line control start signal is an external signal that can be received by the Power Focus 3000 unit from a digital input. Enable: Power Focus will wait for an external signal before starting the Job. Disable (default): Line control is disabled.
J208
Repeat job
Enable (default): After a Job is completed, the Job will be automatically restarted. To turn off this feature the Job must be aborted, deleted or the Job Off mode must be selected. Disable: The Job will not be restarted when it is completed.
J209
Tool loosening
This parameter determines if it will be allowed to loosen after a performed tightening according to the options above. Enable: Tool loosening is unlocked. Disable: Tool loosening is be locked. Enable only on NOK tightening: The tool loosening is enable when the performed tightening is not accepted. The tool loosening will be disable when the performed tightening is accepted.
194
Page 195
Parameter List
18.3
Configuration
C10x Password & name C100
Use Password
Prevents parameter updates on the Power Focus keyboard.
C101
Password entry scope
Tells which unit is allowed to enter the password. - ToolsTalk - All
C102
Config password
Choose a password, which will give write access to all parameters except those for the network.
C103
Network password
Choose a password, which will give write access to the network parameters.
C105
Ch ID number
C106
PF name
Here you can indicate the number ID of the channel/system to which programming refers. Valid values are 0-20. 0 is only used for standalone PF. Name of the unit. You can use up to 20 characters.
C107
Cell ID
Cell identification number. Valid values are 0-1000.
C108
Cell name
Name of the HW group (Cell) name defines the cell that comprises the HW group. You can use up to 20 characters.
C109
Set date and time
C11x Display set-up 1 C110 Config run display 1
Shows how the result after a tightening will be presented in a Graph. Four variables can be shown at the same time. In PC, activate the part window with the left mouse button, open the list with variables with the right mouse button, and select the variable that you want to follow.
C111
Config run display 2
Different layouts of display.
C12x Display set-up 2 C120
Language
Select language from a list that is available.
195
Page 196
Parameter List C121
Tq presentation unit
Select unit for showing torque.
C122
Viewing angle
You can choose between Nm (set value), ft.lb, in.lb and kgfm. Set the Graph display- viewing angle.
C123
Back light auto off
C124
Soft key enable
C126
Graph with angle offset
If Yes is selected, the lights on the graph display will turn off after 15 minutes of inactivity. The light will come on again after a button is pushed or after a tightening. Here you connect and disconnect the menu selection buttons. When connected, the buttons have the functions shown above on the screen. Defines if graph is shown with angle offset.
C13x Options C130
Lock on reject
When Lock on reject is set to YES, the tool locks when a NOK tightening has occurred. The options are: Digin reset or Rev ring reset. To open tool use Digin reset or Rev ring reset.
C131
Default value is NO. Disable loosening at OK Yes/No When yes, it is not possible to loosen the tightening at OK.
C132
Reset batch at Pset change
C15x Reset C150 Delete all results C151
Total reset
Yes/No. Default is Yes. Resets the batch counter when a new Pset is selected. Tightening database and statistical database for the Power Focus is deleted. Resets all programming, tightenings and statistics.
C16x Printer set-up C160
Printer type
With parameter Printer type the printer is selected. Options are: IBM, HP and Epson.
C16
Paper size
With parameter Paper size the paper format is selected. Options are: A4 or US letter.
C162
Continuos print
With parameter Continuos print set to YES, the results after each tightening are automatically sent to the printer port.
196
Page 197
Parameter List C20x I/O device 0-7 C200
Internal I/O
Power Focus features four built- in digital inputs and relays. These parameters are used to configure the digital inputs and relays.
C201 C202 C203 C204 C205 C206 C207
Device 1 Device 2 Device 3 Device 4 Device 5 Device 6 Device 7
Here, for example, you can configure a Selector, an RE alarm or an I/O expander.
C21x I/O Device 8-15 C210 C211 C212 C213 C214 C215 C216 C217
Device 8 Device 9 Device 10 Device 11 Device 12 Device 13 Device 14 Device 15
See I/O device 0-7 [C20x].
C22x Other I/Os C220
Tool start select source
Selection of tool trigger start source: - Tool trigger - Digin - FieldBus - Syncstart
C221
Job select source
Selection of job start source: - Off - Digin - Ethernet/Serial - Identifier - FieldBus - PF/Keyboard
197
Page 198
Parameter List C222
Pset select source
Define from where you want to select the Psets: - Off - Selector - Digin - Ethernet/Serial - Identifier - FieldBus - PF Keyboard
C223
Tool light con source
Selection of tool light control source. Available options: - PF controlled:1 - PF controlled:2 - PF controlled:3
C224
Tool light mode
On/Off. Defines whether the tool LEDs should light for a specified period of time (on) or continuously (off) after a tightening. Default is Off.
C225
Tool light on timer
Select time for tool light signal, can be set between 0 and 300 sec. Only valid if tool light mode [C224] is on.
C226
Selector confirm
Define if the selector confirms selection of Psets. It is also used when selecting Psets in a job. Options: - Off - On - On with Ack.
C227
Job select source override
This parameter makes it possible to choose a method to override an already selected job. Possible options: - Off (default) - Digin - Ethernet/Serial - Identifier - FieldBus - PF/Keyboard
C30x Remote communication C301
IP address
The IP address is a number for identification in a network.
C302
Subnet mask
Tells from which Subnet the Power Focus can be reached.
C303
Default router
IP address of the router used on the Subnet.
198
Page 199
Parameter List C304
Netmaster IP address
The Net Master IP address. The address should be written into each included Cell Master. The Net Master monitors and collects information from the Cell Masters included in the system.
C305
Cellmaster IP address
The Cell Master IP address. The address must be written into each included Cell Member. The Cell Master monitors and collects information from the units included in the Cell.
C306
Jobreference IP address
The Job Reference IP address. The address must be written into every included Job Member in the Job group The Job Reference monitors and collects information from the Job Members included in the Job group.
C307
Syncreference IP address
The Sync Re ference IP address. The address must be written into every Sync Member. The Sync Reference monitors and collects information from the Sync Members included in the Cell.
C31x Advanced com C310
Cell keep alive
C32x Serial ports setup C320 Serial 1 baudrate
Defines the timeout for the link handler between multicast messages. All Power Focus units in the factory should show the same time. Default value is 6 s.
Options: - 2400 - 4800 - 9600
C321
Serial 1 protocol
Options: - None - ASCII - 3964R
C322
Serial 2 baudrate
Options: 2400, 4800, 9600, 19 200, 38 400, 57 600, 155 200 kbit/s
199
Page 200
Parameter List C40x ToolsTalk set-up C400
Port
C41x ToolsNet set-up
Port number for ToolsTalk communication. Default value 6543. A ToolsNet database registers and stores the results from tightenings, graphs, data and history. Each Power Focus unit can store information from approximately 5000 tightenings. But the capacity in the ToolsNet database is, in principle, unlimited. The information can be mapped against the Power Focus, object or VIN-number, as desired.
C410
ToolsNet
Select ON/OFF. When ON, result after each tightening is recorded in ToolsNet.
C411
NetPC IP address
IP address for ToolsNet.
C412
Port
Port number for ToolsNet communication.
C413
Results
None/All/Not Ok The results reported to ToolsNet.
C414
Trace
None/All/Faulty The traces reported to ToolsNet.
C42x Multicast set-up C420
Multicast
C421
Multicast IP address Multicast IP address, default value 225.6.7.8. It is possible to set this between 224.0.0.1 (all device on this sub net) and 239.255.255.255 (Multicast standard).
C422
Port
Port number for Multicast communication (default is 8086).
C423
Results
The results that are reported to the Multicast address.
C424
Graphs
The traces that are reported to the Multicast address.
C426
Sync status
Used if you want to send the sync status on multicast.
C427
Event status
Used if you want to send event code on multicast.
200
Multicast on/off.
Page 201
Parameter List
18.4
Diagnostic
D10x D100
Tool General information Tool type
D101
Motor size
Shows information about the motor size in the tool. Type formats are: 4, 7, 9 or 4/7.
D102
Serial No
Shows the serial number of the tool.
D103
Gear ratio
Shows the mechanical gear ratio for the tool.
D104
Tool max torque
Shows the max tightening torque for the tool in chosen unit. Possible values between 0.1 and 6553 Nm.
Shows the tool type, S or DS.
The value is possible to change if correct password privileges are met. Note that tool max torque must only be changed if you have tool knowledge. D105
User tool message
User tool message shows a user specified message string of maximum 35 characters. The message is stored in the tool memory. The value is possible to change if correct password privileges are met.
D11x D110
Tool calibration Calibration value
D111
Calibration date
Shows the date and time for the last performed tool calibration.
D112
Set calibration value
This parameter performs a shunt calibration, writes a new calibration value and calibration date in the tool memory.
D114
Do motortuning
When selected, this parameter will perform motortuning on the connected tool.
Shows the calibration value stored in the tool.
201
Page 202
Parameter List D115
Normalisation value
Shows the normalisation value for the tool. The value is possible to change if correct password privileges are met. Valid limits are 1000 to 9999 Nm. Default value is 1000 Nm.
D12x D120
Open End parameters Use Open End
Defines if a tool with an Open End head will be used. If open end is set to No, the remaining of the Open end parameters will not be available. Shows if the Open end has to use an inverted motor rotation.
D121
Inverted motor rotation
D122 D123
Open end tightening direction Open end play
Defines if Open end CW (clockwise) or CCW (counter clockwise) is to be used. Shall show the open end play in degrees.
D124
Open end tune
Shall perform an open end tuning.
D13x D130
Tools service Total number of tightenings
Total number of tightenings. This counter is never reset.
D131
Service indicator
If Yes, the Power Focus 3000 will alert the user when the service interval has expired.
D132
Number of tightening since service
The number of tightenings since last service.
D133
Service interval
Number of tightenings between services. Multiply the value by 10 000.
D134
Latest service date
The date of the latest performed service.
D135
Service counter reset
Resets the Number of tightenings since the tool was last serviced, sets Latest service date to current date and clears the service indicator alarm.
202