Page 193

Parameter List

18.2

Job

J200

Name

J201

Forced Job

J202

Job list / Edit Job

The name of the Job helps the operator to identify the different Jobs (Maximum 25 characters). When selecting “Forced job”, the included Psets are performed in the listed order. This parameter defines which Psets are included in a Job. Selected Psets must be available. Enable: When Forced order is selected the tightenings must be performed in the order specified in the Job list. Disable: If Forced order is not selected the tightening can be performed in any order (free order).

J203

Maxtime for first tightening

Specifies the time limit allowed from when the Job is selected until the first tightening is performed. If the time limit is exceeded the Job is aborted. This value is adjustable between 0 s – 9999 s, where 0 means no timer and is the default value.

J204

Maxtime complete Job

Specifies the time limit allowed from when the Job is selected until the Job is completed. If the time limit is exceeded the Job is aborted. This value is adjustable between 0 s – 9999 s, where 0 means no timer and is the default value.

J205

Batch count type

OK (default): Specifies that only accepted tightenings will be considered performed and counted. OK+NOK: Specifies that also not accepted tightenings will be considered performed and counted.

J206

Lock at Job done

This parameter determines whether the tools shall continue to be operative following an approved (OK) Job. Enable: The tool will be disabled after the Job is performed. Disable: The tool will not be disabled after the Job is performed.

193

Page 194

Parameter List J207

Use line control

Line Control related inputs and outputs have only effect on a Job reference. A Line control start signal is an external signal that can be received by the Power Focus 3000 unit from a digital input. Enable: Power Focus will wait for an external signal before starting the Job. Disable (default): Line control is disabled.

J208

Repeat job

Enable (default): After a Job is completed, the Job will be automatically restarted. To turn off this feature the Job must be aborted, deleted or the Job Off mode must be selected. Disable: The Job will not be restarted when it is completed.

J209

Tool loosening

This parameter determines if it will be allowed to loosen after a performed tightening according to the options above. Enable: Tool loosening is unlocked. Disable: Tool loosening is be locked. Enable only on NOK tightening: The tool loosening is enable when the performed tightening is not accepted. The tool loosening will be disable when the performed tightening is accepted.

194

Page 195

Parameter List

18.3

Configuration

C10x Password & name C100

Use Password

Prevents parameter updates on the Power Focus keyboard.

C101

Password entry scope

Tells which unit is allowed to enter the password. - ToolsTalk - All

C102

Config password

Choose a password, which will give write access to all parameters except those for the network.

C103

Network password

Choose a password, which will give write access to the network parameters.

C105

Ch ID number

C106

PF name

Here you can indicate the number ID of the channel/system to which programming refers. Valid values are 0-20. 0 is only used for standalone PF. Name of the unit. You can use up to 20 characters.

C107

Cell ID

Cell identification number. Valid values are 0-1000.

C108

Cell name

Name of the HW group (Cell) name defines the cell that comprises the HW group. You can use up to 20 characters.

C109

Set date and time

C11x Display set-up 1 C110 Config run display 1

Shows how the result after a tightening will be presented in a Graph. Four variables can be shown at the same time. In PC, activate the part window with the left mouse button, open the list with variables with the right mouse button, and select the variable that you want to follow.

C111

Config run display 2

Different layouts of display.

C12x Display set-up 2 C120

Language

Select language from a list that is available.

195

Page 196

Parameter List C121

Tq presentation unit

Select unit for showing torque.

C122

Viewing angle

You can choose between Nm (set value), ft.lb, in.lb and kgfm. Set the Graph display- viewing angle.

C123

Back light auto off

C124

Soft key enable

C126

Graph with angle offset

If Yes is selected, the lights on the graph display will turn off after 15 minutes of inactivity. The light will come on again after a button is pushed or after a tightening. Here you connect and disconnect the menu selection buttons. When connected, the buttons have the functions shown above on the screen. Defines if graph is shown with angle offset.

C13x Options C130

Lock on reject

When Lock on reject is set to YES, the tool locks when a NOK tightening has occurred. The options are: Digin reset or Rev ring reset. To open tool use Digin reset or Rev ring reset.

C131

Default value is NO. Disable loosening at OK Yes/No When yes, it is not possible to loosen the tightening at OK.

C132

Reset batch at Pset change

C15x Reset C150 Delete all results C151

Total reset

Yes/No. Default is Yes. Resets the batch counter when a new Pset is selected. Tightening database and statistical database for the Power Focus is deleted. Resets all programming, tightenings and statistics.

C16x Printer set-up C160

Printer type

With parameter Printer type the printer is selected. Options are: IBM, HP and Epson.

C16

Paper size

With parameter Paper size the paper format is selected. Options are: A4 or US letter.

C162

Continuos print

With parameter Continuos print set to YES, the results after each tightening are automatically sent to the printer port.

196

Page 197

Parameter List C20x I/O device 0-7 C200

Internal I/O

Power Focus features four built- in digital inputs and relays. These parameters are used to configure the digital inputs and relays.

C201 C202 C203 C204 C205 C206 C207

Device 1 Device 2 Device 3 Device 4 Device 5 Device 6 Device 7

Here, for example, you can configure a Selector, an RE alarm or an I/O expander.

C21x I/O Device 8-15 C210 C211 C212 C213 C214 C215 C216 C217

Device 8 Device 9 Device 10 Device 11 Device 12 Device 13 Device 14 Device 15

See I/O device 0-7 [C20x].

C22x Other I/Os C220

Tool start select source

Selection of tool trigger start source: - Tool trigger - Digin - FieldBus - Syncstart

C221

Job select source

Selection of job start source: - Off - Digin - Ethernet/Serial - Identifier - FieldBus - PF/Keyboard

197

Page 198

Parameter List C222

Pset select source

Define from where you want to select the Psets: - Off - Selector - Digin - Ethernet/Serial - Identifier - FieldBus - PF Keyboard

C223

Tool light con source

Selection of tool light control source. Available options: - PF controlled:1 - PF controlled:2 - PF controlled:3

C224

Tool light mode

On/Off. Defines whether the tool LEDs should light for a specified period of time (on) or continuously (off) after a tightening. Default is Off.

C225

Tool light on timer

Select time for tool light signal, can be set between 0 and 300 sec. Only valid if tool light mode [C224] is on.

C226

Selector confirm

Define if the selector confirms selection of Psets. It is also used when selecting Psets in a job. Options: - Off - On - On with Ack.

C227

Job select source override

This parameter makes it possible to choose a method to override an already selected job. Possible options: - Off (default) - Digin - Ethernet/Serial - Identifier - FieldBus - PF/Keyboard

C30x Remote communication C301

IP address

The IP address is a number for identification in a network.

C302

Subnet mask

Tells from which Subnet the Power Focus can be reached.

C303

Default router

IP address of the router used on the Subnet.

198

Page 199

Parameter List C304

Netmaster IP address

The Net Master IP address. The address should be written into each included Cell Master. The Net Master monitors and collects information from the Cell Masters included in the system.

C305

Cellmaster IP address

The Cell Master IP address. The address must be written into each included Cell Member. The Cell Master monitors and collects information from the units included in the Cell.

C306

Jobreference IP address

The Job Reference IP address. The address must be written into every included Job Member in the Job group The Job Reference monitors and collects information from the Job Members included in the Job group.

C307

Syncreference IP address

The Sync Re ference IP address. The address must be written into every Sync Member. The Sync Reference monitors and collects information from the Sync Members included in the Cell.

C31x Advanced com C310

Cell keep alive

C32x Serial ports setup C320 Serial 1 baudrate

Defines the timeout for the link handler between multicast messages. All Power Focus units in the factory should show the same time. Default value is 6 s.

Options: - 2400 - 4800 - 9600

C321

Serial 1 protocol

Options: - None - ASCII - 3964R

C322

Serial 2 baudrate

Options: 2400, 4800, 9600, 19 200, 38 400, 57 600, 155 200 kbit/s

199

Page 200

Parameter List C40x ToolsTalk set-up C400

Port

C41x ToolsNet set-up

Port number for ToolsTalk communication. Default value 6543. A ToolsNet database registers and stores the results from tightenings, graphs, data and history. Each Power Focus unit can store information from approximately 5000 tightenings. But the capacity in the ToolsNet database is, in principle, unlimited. The information can be mapped against the Power Focus, object or VIN-number, as desired.

C410

ToolsNet

Select ON/OFF. When ON, result after each tightening is recorded in ToolsNet.

C411

NetPC IP address

IP address for ToolsNet.

C412

Port

Port number for ToolsNet communication.

C413

Results

None/All/Not Ok The results reported to ToolsNet.

C414

Trace

None/All/Faulty The traces reported to ToolsNet.

C42x Multicast set-up C420

Multicast

C421

Multicast IP address Multicast IP address, default value 225.6.7.8. It is possible to set this between 224.0.0.1 (all device on this sub net) and 239.255.255.255 (Multicast standard).

C422

Port

Port number for Multicast communication (default is 8086).

C423

Results

The results that are reported to the Multicast address.

C424

Graphs

The traces that are reported to the Multicast address.

C426

Sync status

Used if you want to send the sync status on multicast.

C427

Event status

Used if you want to send event code on multicast.

200

Multicast on/off.

Page 201

Parameter List

18.4

Diagnostic

D10x D100

Tool General information Tool type

D101

Motor size

Shows information about the motor size in the tool. Type formats are: 4, 7, 9 or 4/7.

D102

Serial No

Shows the serial number of the tool.

D103

Gear ratio

Shows the mechanical gear ratio for the tool.

D104

Tool max torque

Shows the max tightening torque for the tool in chosen unit. Possible values between 0.1 and 6553 Nm.

Shows the tool type, S or DS.

The value is possible to change if correct password privileges are met. Note that tool max torque must only be changed if you have tool knowledge. D105

User tool message

User tool message shows a user specified message string of maximum 35 characters. The message is stored in the tool memory. The value is possible to change if correct password privileges are met.

D11x D110

Tool calibration Calibration value

D111

Calibration date

Shows the date and time for the last performed tool calibration.

D112

Set calibration value

This parameter performs a shunt calibration, writes a new calibration value and calibration date in the tool memory.

D114

Do motortuning

When selected, this parameter will perform motortuning on the connected tool.

Shows the calibration value stored in the tool.

201

Page 202

Parameter List D115

Normalisation value

Shows the normalisation value for the tool. The value is possible to change if correct password privileges are met. Valid limits are 1000 to 9999 Nm. Default value is 1000 Nm.

D12x D120

Open End parameters Use Open End

Defines if a tool with an Open End head will be used. If open end is set to No, the remaining of the Open end parameters will not be available. Shows if the Open end has to use an inverted motor rotation.

D121

Inverted motor rotation

D122 D123

Open end tightening direction Open end play

Defines if Open end CW (clockwise) or CCW (counter clockwise) is to be used. Shall show the open end play in degrees.

D124

Open end tune

Shall perform an open end tuning.

D13x D130

Tools service Total number of tightenings

Total number of tightenings. This counter is never reset.

D131

Service indicator

If Yes, the Power Focus 3000 will alert the user when the service interval has expired.

D132

Number of tightening since service

The number of tightenings since last service.

D133

Service interval

Number of tightenings between services. Multiply the value by 10 000.

D134

Latest service date

The date of the latest performed service.

D135

Service counter reset

Resets the Number of tightenings since the tool was last serviced, sets Latest service date to current date and clears the service indicator alarm.

202