Power Focus 3000: Control and Drive Unit for TENSOR-S Electric Nut Runners: User Interfaces, pages 263 to 272

Pages 263 to 272 of 315, from Power Focus 3000: Control and Drive Unit for TENSOR-S Electric Nut Runners

The original document is the PDF (7.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Atlas Copco PF3007-C-HW and Atlas Copco PF3007-G-HW

Page 263

Appendix C

23

Appendix C: Digital inputs and outputs

Digital inputs Function/Name Not used / Off Reset batch Unlock tool

Tool disable n.o.

Tool disable n.c.

Tool tightening disable Tool loosening disable Remote start. Pulse

Remote start. Cont.

Tool start loosening

Batch increment

Description The input is not used. Resets the batch counter for the current Psets. If the tool is locked for example because of lock on faulty, it can be unlocked with this input. It influences the same bit as “Tool Tightening Disable”. A fault can occur for that reason if both these are defined on different inputs because they are inverses of each other. The tool shall not be able to start when this input is active. If the tool rotates, it shall immediate stop when this input will be active. The input is active when it is switched on. Normally opened. The function is similar to Tool disable n.o. but inverted. The tool shall not be able to start when this input is active. If the tool rotates, it shall immediately stop if this input becomes active. Normally closed. The function is similar to Tool disable n.o. but only for tightening. Loosening is not affected. The function is similar to Tool disable n.o. but only for loosening. Tightening is not affected. Tool start tightening if the input pulse is > 100 ms. Tool continues running until target or current limit is reached. Warning! The position of the tool direction ring is not taken into account. This may cause tool reaction forces in a direction unexpected to the operator. Tool start tightening. The tool stops if the input signal disappears (equal to start with tool switch). Warning! The position of the tool direction ring is not taken into account. This may cause tool reaction forces in a direction unexpected to the operator. Start the tool in loosening mode (for all of control strategies). Tool stops if the signal disappears. Warning! The position of the tool direction ring is not taken into account. This may cause tool reaction forces in a direction unexpected to the operator. Warning! Loosening will be performed for all strategies including Reverse angle and Rotate spindle forward/reverse. Activating increases the batch counter with one. If the batch is “filled”, batch OK will be activated, as usual. In the memory these “tightenings” will be stored as OK tightenings but they are marked and include no numerical results. They will not influence the statistic.

263

Page 264

Appendix C Batch decrement

This function allows you to re-do the last tightening in a Job. The batch counter of the Pset or Multistage is decreased with one step. It is not possible to go back one stage after the job has been completed.

Restart Job

Bypass Pset Abort Job Job Off Pset toggle Reset relays Pset select bit 0-7

In both forced order Job and free order Job batch decrement is only possible from the Job reference. This function allows the user to restart the running Job without needing to reselect the Job. All Batch counters in the running Job resets and the Job options timers will also be restarted. This function offers the option to skip a specific Pset or Multistage in the running Job, independently of batch size. Cancels a current Job (gives job aborted). If Lock_at_Job_Done is activated, the tool will be locked. Disable the JOB-mode. All Psets can be used individually. Useful when finetuning is needed on the Psets without remove the job configuration. Turns over in those Psets that are connected to a socket in a selector. This function is also used in the Job functionality (Job free order). Resets all relays. Not valid for relays which are controlled of Tracking event. Pset select input. When selected it decides which Pset will be used. These inputs are hard coded which means that binary 1 is equal to Pset 1 etc. 0 = locked tool. All used select bits shall be configured in the same I/O-device.

Job select bit 0-6

Line control start Line control alert 1 Line control alert 2 Ack error message FieldBus digin 1-4

Flash tool green light

Job select input. When selected it decides which job will be used. These inputs are hard coded which means that binary 1 is equal to job 1 etc. All used select bits shall be configured in the same I/O-device. Input for a position breaker. Needs to start a Job with line control. Input for a position breaker. Gives alarm if a Job with line control is not finished. Input for a position breaker. Gives alarm if a Job with line control is not finished. Confirms an occurred Error / Event. Equals to press PF enter button. These inputs give a direct link to FieldBus. FieldBus digin #X must be configured both in PF or I/O expender and in FieldBus. FieldBus mimic the status on a dig input. Activates the tool green light (flashing at approximately 1.33 Hz). The light is on until tightening starts. After tightening the tool light indicates status according to result. This input is ignored during rundown.

Click wrench 1 -4 ID-card

264

These inputs are activated if the Click wrench strategy is used. Signal input from Card reader to indicate that a ID-card is inserted in the reader.

Page 265

Appendix C Digital outputs Function/Name

Relay Timer To next tight.

Time

Not used / Off OK NOK

X X

X X

Low High Low torque High torque Low angle High angle Cycle complete

X X X X X X X

X X X X X X X

Alarm n x OK

X

X

X X X

X X X

Job OK Job NOK Job Aborted Job running PF ready

Description Tracking

X

X X

Tool ready

X

Tool start switch

X

Dir. switch = CW Dir. switch = CCW Tool tightening

X X X

Tool loosening

X

Tool running Stat alarm

X X

X

Tool Locked Received identifier

X X

X

Output is not used. All results are within the specified limits. Some result is above or below any of the programmed max or min limits, or some other not approved result as re-hit. The result is below any of the programmed min limits. The result is above any of the programmed max limits. The result is lower than min torque limit. The result is higher than max torque limit. The result is lower than min angle limit. The result is higher than max angle limit. Tightening is finished. The tool shut on target and End time is expired. Follow the Alarm light on the Power Focus front. Batch OK. Job is performed and OK. Job is performed and NOK Running Job was aborted. A Job is selected. The Power Focus controller is “healthy”. No errors needs to be acknowledged. Power Focus is ready to do tightenings. A Valid Job and/or Pset is selected. The tool will start when the trigger is pressed. Relay that follows the tool start input. Follow the configured Tool start input source. The Tool direction switch is set in its CW position. The Tool direction switch is set in its CCW position. Active when the tool rotates in tightening direction. Inactive when the target is reached or when start button/remote start is released. Active when the tool rotates in release direction. Inactive when start button or remote start is released. The tool is rotating CW or CCW. Follows the stat indicator on the Power Focus’ front. Active when some of the selected statistic limit or trend is outside of the approved limits. Active when the Tools is locked and is unable to do tightenings. Active when an identifier string is received in Power Focus.

265

Page 266

Appendix C Running Pset bit 0 -7

X

Running job bit 0 -6

X

Line control start Line control done

X X

X X

Line control alert 1

X

X

Line control alert 2 Service indicator

X

X

X X X

X X X

Line control warning. Active when the service indicator function is active and the service level is reached. On until the service indicator is reset. The relay is controlled from FieldBus. Relay follows tool red light (no flashing). Relay follows tool green light. Also following the function Flash tool green light (no flashing). Relay follows tool yellow light (no flashing). Total OK on a Sync tightening. Total NOK on a Sync tightening. Individual OK on a Sync spindle.

X

X

Individual NOK on a Sync spindle.

X

FieldBus relay 1 - 4 Tool_Red_Light Tool_Green_Light Tool_Yellow_Light Sync OK Sync NOK Sync spindle 1-10 OK Sync spindle 1-10 NOK

266

Shows which Pset is selected. 0 = locked tool. Shows which job is selected. 0 = no running job. Indicates that the Line control start signal is received. Indicates that a Job with Line control have been done (without receiving Line control alert 2). Line control warning.

X X X X

Page 267

Appendix D

24

Appendix D: FieldBus

This appendix describes the different possible selections for the FieldBus. It also describes the different data types that are used in the FieldBus configuration.

24.1

Bit map select (Endian Mode)

Motorola Endian

Word

Intel_16 Endian

Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Word Byte 1 Byte 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

Motorola Endian is default setting for ProfiBusDP, InterBus and ModBusPlus. Intel Endian is default setting for DeviceNet.

267

Page 268

Appendix D

24.2

FieldBus data types

The data field in the FieldBus is from the beginning a blank data field without structure. In order to map Power Focus item data types into FieldBus we defined FieldBus Data Type, which holds the information about placement and structure of a certain application data type mapped into the FieldBus data field. The table below shows the different data types used in FieldBus data. The section Items From/To PF shows the data type available for different items. Data type Bit Bit Field

Character Character String Change Character String Input

Fixed Point Number

Unsigned 16 (U16) Unsigned 32 (U32) U32_HNW

Description One bit. Normally used for discrete I/O-data. Length is 2 - 8 bits. All bits must be in the same byte. The left bit is the most significant bit and the right bit is the less significant bit, i.e. 0001 = 1, 1000 = 8. One byte ASCII code. Character string. Each character uses one byte ASCII code. Range: 2 - 25 bytes. Character string with an extra “counter” byte in front. The extra byte is an integer counter and must increase each time when the character string is entered to be able to detect a new input. If you want to enter the same value again (e.g. the same Job number), just change the counter. Two byte integer part and two byte decimal part. The first two bytes hold the integer part and the last two bytes hold the decimal part. Used to represent torque value. 16-bit unsigned integer. Decimal 0 – 65 535. 32-bit unsigned integer. Decimal 0 – 4 294 967 295. 32-bit unsigned integer. MSW is the higher number word.

Important! Common for all data types is that a change must occur to get the PLC or Power Focus to detect a new data entry. For example, if you want to select JOB number 3 two times in a row you must select 0 in between.

268

Page 269

Appendix D

24.2.1 Most Significant Bit (MSB) The Power Focus 3000 uses position format in all encoding and decoding data types. In PF position format, the Most Significant Bit is the bit furthest to the left. If a data type is less than one word, the MSB is the bit furthest to the left. If data type is longer than one word, the MSB is the bit furthest top- left. If a FieldBus type uses Intel Endian, byte numbers are swapped before encoding or decoding to a specific data type.

24.2.2 FieldBus data convert To get a better understanding of converting FieldBus Data into Power Focus specific data type, some examples are given in this section, which contains Character String, Fixed Point Number and Integer. Character String Character String is in a reading order, i.e. from left to right, from top to bottom, regardless of the byte order. The difference between CharStringChange and CharStringInput is a counter byte added before character string in CharStringInput. When the counter changes, a new input is considered. Motorola Endian

Data type

Word

Byte 0

Byte 1

CharStringChange

0 1 2 3 4 5

P E 2 1(counter) S T

S T

CharStringInput

Convert to PF data

PSET2 P E 2

PSET2

269

Page 270

Appendix D Intel Endian

Data Type CharStringChange

CharStringInput

Word 0 1 2 3 4 5

Byte 1 P E 2 1 (counter) S T

Byte 0 S T

Convert to PF data

PSET2 P E 2

PSET2

Fixed Point Number Fixed Point Number integer part is in low number word, and decimal part is in high number word. The table below shows the conditions valid for the integer and decimal parts (i.e. if integer part is 1 digit or 2 digits, decimal part is 2 digits): Integer part (in digits) 1 or 2 3 4

Decimal part (in digits) 2 1 0

Motorola Endian

Data type FixedPointNumber

270

Word 0 1

Byte 0 0 0

Byte 1 12 15

Convert to PF data 12.15

Page 271

Appendix D Intel Endian

Data type

Word

Byte 1

Byte 0

Convert to PF data

FixedPointNumber

0 1

0 0

12 4

12.04

Integer Unsigned16 is a 16-bit integer and Unsigned32 is a 32-bit integer. U32_HMW is a special case of Unsigned32, which is used in Intel Endian. Motorola Endian

Data type Unsigned16 Unsigned32

Wor d Byte 0 0 1 1 0 (MSB*) 2 0 * MSB – Most Significant Byte; LSB – Least Significant Byte.

Byte 1 0 1 0 (LSB*)

Convert to PF data 256

Byte 0 0 1 0 (LSB*) 1 (LSB*) 0

Convert to PF data 256

65536

Intel Endian

Data type Unsigned16 Unsigned32 U32_HNW

Word 0 1 2 3 4

Byte 1 1 0 (MSB*) 0 0 0 (MSB*)

65536 1

* MSB – Most Significant Byte; LSB – Least Significant Byte.

271

Page 272

Appendix D

24.3

Items from PF

In this section follows a description of the possible items to select when data from the Power Focus is configured. Set signal = a signal to set a bit / byte/bytes in the PLC Reset signal = a signal to reset a bit / byte/bytes in the PLC Angle Status Status Angle result Data type Character

String length 1 byte ASCII

Bit Field

2 bits

Value O = OK L = Low H = High 00 = Not used 01 = OK 10 = High 11 = Low

Set signal Tightening result

Reset signal Start new tightening or new Pset selected.

Value 0 = Not used 1 = High

Set signal Tightening result

Reset signal Start new tightening or new Pset selected

Value 0 = Not used 1 = Low

Set signal Tightening result

Reset signal Start new tightening or new Pset selected

Value 0 = Not used 1 = OK

Set signal Tightening result

Reset signal Start new tightening or new Pset selected

Value O = OK N = NOK 00 = Not used 01 = OK 10 = NOK

Set signal Batch done or reset

Reset signal Start new tightening or new Pset selected

Value 0 = Not used 1 = NOK

Set signal Batch reset

Reset signal Start new tightening or new Pset selected

Angle Status HIGH Angle result is above max limit Data type String length Bit 1 bit

Angle Status LOW Angle result is below min limit Data type String length Bit 1 bit

Angle Status OK Angle result is within limits Data type String length Bit 1 bit

Batch Status Batch OK (done) or NOK (reset) Data type String length Character 1 byte ASCII Bit Field

2 bits

Batch Status NOK Batch is NOK (batch aborted) Data type String length Bit 1 bit

272