Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of DeviceNet Slave T1K-DEVNETS

Spec sheet · AutomationDirect

DeviceNet Slave T1K-DEVNETS

Spec sheet7 pagesPDF 3.8 MB

Catalog pages for the AutomationDirect T1K-DEVNETS DeviceNet slave module for Terminator I/O, with installation and power data.

Download the PDF3.8 MB

Covers · 1 model

The models it covers

Summary

What is in it

AutomationDirect catalog pages for the T1K-DEVNETS, a DeviceNet slave network interface that links Terminator I/O discrete and analog modules to a DeviceNet master. It explains how the module works and lists its general specifications and DeviceNet cable lengths, then covers Terminator I/O dimensions and installation, I/O module installation, power supplies and power budgeting, expansion I/O cable configurations, terminal bases and field device wiring options.

Its parts

  1. DeviceNet Slave
  2. Dimensions and Installation
  3. I/O Module Installation
  4. Power Supplies and Power Requirements
  5. Expansion I/O Configurations
  6. Field Device Wiring and Power Options

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

AutomationDirect catalog pages for the T1K-DEVNETS DeviceNet slave module, which links a Terminator I/O system to a DeviceNet master. They give its specifications and the DeviceNet cable lengths by speed, followed by general Terminator I/O pages on mounting, module installation, power budgets, expansion cables and field wiring.

What it is
DeviceNet slave for Terminator I/O; scans and reports all discrete and analog I/O data to a DeviceNet master p. 1
Maximum I/O
1024 input bits and 1024 output bits, analog or discrete p. 1
Network
Standard 4-wire shielded cable, up to 500Kbps; up to 64 devices p. 1, 2
Trunk length
328 ft (100 m) at 500 Kbps; 820 ft (250 m) at 250 Kbps; 1,640 ft (500 m) at 125 Kbps; branches 20 ft (6 m) p. 2
Serial port
RS232C on RJ12; K-sequence and ASCII protocols p. 1
Power draw
250 mA at 5VDC, 45 mA at 24VDC p. 5
Recommended cable
Belden 3085A, YR-29832 or equivalent p. 2
Compatible modules
All Terminator I/O discrete and analog I/O modules p. 1
Certification
The sheet states it is an ODVA certified DeviceNet-compliant slave I/O interface p. 2
Expansion cables
T1K-10CBL(-1) right side to left side, up to two; T1K-05CBL-RR(-1) right to right, one; T1K-05CBL-LL(-1) left to left, one, only with an RR cable p. 6
Think & Do master
SST DeviceNet PCI Master Card 5136-DNP-PCI, not supplied by AutomationDirect p. 2

What this sheet walks you through

  • How a Terminator I/O DeviceNet sub-system fits a DeviceNet network p. 1
  • DeviceNet trunk and branch lengths at each speed p. 2
  • Unit dimensions and mounting orientation p. 3
  • Installing and removing I/O modules on DIN rail p. 4
  • Calculating the power budget for each power supply p. 5
  • Expansion cable layouts and where power supplies may go p. 6
  • Wiring field devices and 24 VDC power options p. 7
  • Hot-swapping I/O modules with power on p. 4, 7

Good to know

  • Terminator I/O units are mounted horizontally and never upside-down, for cooling airflow. p. 3
  • A T1K-05CBL-LL(-1) cable cannot connect to the left side of the network interface base. p. 6
  • Each power supply powers only the network interface and I/O modules to its right; budget each supply separately. p. 5
  • Modules are not jumpered together into a 24 VDC bus when hot swap is used. p. 7
  • The catalog does not replace the product data sheet or the T1K-INST-M Installation and I/O Manual. p. 3

Questions this sheet answers

How many I/O points can the T1K-DEVNETS handle?

Up to 1024 input bits and 1024 output bits, analog or discrete. p. 1

How long can the DeviceNet trunk be?

328 ft (100 m) at 500 Kbps, 820 ft (250 m) at 250 Kbps and 1,640 ft (500 m) at 125 Kbps, with branches up to 20 ft (6 m). p. 2

How much power does the T1K-DEVNETS draw?

250 mA at 5VDC and 45 mA at 24VDC, per the power requirements table. p. 5

What DeviceNet cable is recommended for the T1K-DEVNETS?

Belden 3085A, YR-29832, or an equivalent. p. 2

Which PC master card works with Think & Do software?

The sheet recommends the SST DeviceNet PCI Master Card, part number 5136-DNP-PCI, which AutomationDirect does not provide. p. 2

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. DeviceNet1
  2. Slave1
  3. DeviceNet Slave2
  4. Dimensions and Installation3
  5. I/O Module Installation4
  6. Power Supplies and Power Requirements5
  7. Expansion I/O Configurations6
  8. Field Device Wiring and Power Options7

From the PDF’s own bookmarks.

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 71-7

The file

Revision and size

RevisionVolume 13
PublisherAutomationDirect
Pages7
PDF3.8 MB
TextText from the PDF itself.

The first pages · 4 of 7

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 7
Page 2
Page 2of 7
Page 3
Page 3of 7
Page 4
Page 4of 7

More documents · 1

For the same models