The text of a manual · part 1 of 7
Terminator I/O DeviceNet Base Controller User Manual (T1K-DEVNETS), pages 1 to 9
Pages 1 to 9 of 63
The original document is the PDF (4.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AutomationDirect T1K-DEVNETS
Page 1
T1K - DEVNETS DeviceNet Base Controller User Manual
AUTOMATION DIRECT...
Manual Number T1K-DEVNETS - M
Page 2
WARNING Thank you for purchasing automation equipment from Automationdirect.com. We want your new DirectLOGIC automation equipment to operate safely. Anyone who installs or uses this equipment should read this publication (and any other relevant publications) before installing or operating the equipment. To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and usually change with time. It is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. At a minimum, you should follow all applicable sections of the National Fire Code, National Electrical Code, and the codes of the National Electrical Manufacturer’s Association (NEMA). There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. Our products are not fault–tolerant and are not designed, manufactured or intended for use or resale as on–line control equipment in hazardous environments requiring fail–safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life support machines, or weapons systems, in which the failure of the product could lead directly to death, personal injury, or severe physical or environmental damage (”High Risk Activities”). Automationdirect.com specifically disclaims any expressed or implied warranty of fitness for High Risk Activities. For additional warranty and safety information, see the Terms and Conditions section of our Desk Reference. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call us at 770–844–4200. This publication is based on information that was available at the time it was printed. At Automationdirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product.
Trademarks This publication may contain references to products produced and/or offered by other companies. The product and company names may be trademarked and are the sole property of their respective owners. Automationdirect.com disclaims any proprietary interest in the marks and names of others.
Copyright 2001, Automationdirect.com Incorporated All Rights Reserved No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Automationdirect.com Incorporated. Automationdirect.com retains the exclusive rights to all information included in this document.
Page 3
AVERTISSEMENT Nous vous remercions d’avoir acheté l’équipement d’automatisation de Automationdirect.comE. Nous tenons à ce que votre nouvel équipement d’automatisation DirectLOGIC fonctionne en toute sécurité. Toute personne qui installe ou utilise cet équipement doit lire la présente publication (et toutes les autres publications pertinentes) avant de l’installer ou de l’utiliser. Afin de réduire au minimum le risque d’éventuels problèmes de sécurité, vous devez respecter tous les codes locaux et nationaux applicables régissant l’installation et le fonctionnement de votre équipement. Ces codes diffèrent d’une région à l’autre et, habituellement, évoluent au fil du temps. Il vous incombe de déterminer les codes à respecter et de vous assurer que l’équipement, l’installation et le fonctionnement sont conformes aux exigences de la version la plus récente de ces codes. Vous devez, à tout le moins, respecter toutes les sections applicables du Code national de prévention des incendies, du Code national de l’électricité et des codes de la National Electrical Manufacturer’s Association (NEMA). Des organismes de réglementation ou des services gouvernementaux locaux peuvent également vous aider à déterminer les codes ainsi que les normes à respecter pour assurer une installation et un fonctionnement sûrs. L’omission de respecter la totalité des codes et des normes applicables peut entraîner des dommages à l’équipement ou causer de graves blessures au personnel. Nous ne garantissons pas que les produits décrits dans cette publication conviennent à votre application particulière et nous n’assumons aucune responsabilité à l’égard de la conception, de l’installation ou du fonctionnement de votre produit. Nos produits ne sont pas insensibles aux défaillances et ne sont ni conçus ni fabriqués pour l’utilisation ou la revente en tant qu’équipement de commande en ligne dans des environnements dangereux nécessitant une sécurité absolue, par exemple, l’exploitation d’installations nucléaires, les systèmes de navigation aérienne ou de communication, le contrôle de la circulation aérienne, les équipements de survie ou les systèmes d’armes, pour lesquels la défaillance du produit peut provoquer la mort, des blessures corporelles ou de graves dommages matériels ou environnementaux (”activités à risque élevé”). La société Automationdirect.comE nie toute garantie expresse ou implicite d’aptitude à l’emploi en ce qui a trait aux activités à risque élevé. Pour des renseignements additionnels touchant la garantie et la sécurité, veuillez consulter la section Modalités et conditions de notre documentation. Si vous avez des questions au sujet de l’installation ou du fonctionnement de cet équipement, ou encore si vous avez besoin de renseignements supplémentaires, n’hésitez pas à nous téléphoner au 770–844–4200. Cette publication s’appuie sur l’information qui était disponible au moment de l’impression. À la société Automationdirect.comE, nous nous efforçons constamment d’améliorer nos produits et services. C’est pourquoi nous nous réservons le droit d’apporter des modifications aux produits ou aux publications en tout temps, sans préavis ni quelque obligation que ce soit. La présente publication peut aussi porter sur des caractéristiques susceptibles de ne pas être offertes dans certaines versions révisées du produit.
Marques de commerce La présente publication peut contenir des références à des produits fabriqués ou offerts par d’autres entreprises. Les désignations des produits et des entreprises peuvent être des marques de commerce et appartiennent exclusivement à leurs propriétaires respectifs. Automationdirect.comE nie tout intérêt dans les autres marques et désignations. Copyright 2001, Automationdirect.comE Incorporated Tous droits réservés Nulle partie de ce manuel ne doit être copiée, reproduite ou transmise de quelque façon que ce soit sans le consentement préalable écrit de la société Automationdirect.comE Incorporated. Automationdirect.comE conserve les droits exclusifs à l’égard de tous les renseignements contenus dans le présent document.
Page 4
1 Manual Revisions If you contact us in reference to this manual, be sure to include the revision number. Title: Terminator I/O DeviceNet Base Controller User Manual Manual Number: T1K–DEVNETS–M Edition Original
Date 11/01
Description of Changes Original issue
Page 5
Table of Contents ii
Chapter 1: Getting Started Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 The Purpose of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 Supplemental Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 Who Should Read this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–3 Introduction to DeviceNet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–4 DeviceNet Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–4 The ODVA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–4 Terminator I/O System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–5 Mini Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–5 T1K–DEVNETS Base Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–6 T1K–DEVNETS Base Controller Features . . . . . . . . . . . . . . . . . 1–6
Chapter 2: Installing the T1K–DEVNETS Base Controller Installing the T1K–DEVNETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2 Mounting on DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2 Connecting the Controller to a Power Supply . . . . . . . . . . . . . . 2–2 Setting the Node Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3 Connecting the Components on the DIN Rail . . . . . . . . . . . . . . 2–3 Removing I/O Modules from the Base . . . . . . . . . . . . . . . . . . . . 2–4 Assembling the I/O Modules and Bases . . . . . . . . . . . . . . . . . . . 2–4 DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–5 Parameter initialization values . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–6 T1K–DEVNETS setup parameters . . . . . . . . . . . . . . . . . . . . . . . 2–6 Wiring the Controller to a DeviceNet Network . . . . . . . . . . . . . . 2–7 Serial Port (RS–232) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–7 Configuring the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–8 Configuring the DeviceNet Base Controller . . . . . . . . . . . . . . . . 2–8 Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–9 Outputs Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–9 Master/Slave Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–10 Terminator I/O Backplane Communications . . . . . . . . . . . . . . . 2–11 I/O Module Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–11
Appendix A: Specification Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A–2
Page 6
Appendix B: Tables Data Input and Output Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . B–2 Input Register Object Class (107) . . . . . . . . . . . . . . . . . . . . . . . . B–2 Output Register Object Class (108) . . . . . . . . . . . . . . . . . . . . . . . B–4 Data Register Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B–5 I/O Diagnostic Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B–6 DIP Switch SW4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B–6 System Information Object Specifications . . . . . . . . . . . . . . . . . B–7
Appendix C: Image Table Mapping Image Table Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C–2
Appendix D: T1K–DEVNETS Think & Do Setup T1K–DEVNETS Think & Do Setup . . . . . . . . . . . . . . . . . . . . . . . . . D–2 T & D Studio setup for PC control . . . . . . . . . . . . . . . . . . . . . . . D–2
Appendix E: T1K–DEVNETS and RSNetWorxt Setup t
Setup T1K–DEVNETS with RSNetWorx . . . . . . . . . . . . . . . . . . E–2 RSLinx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E–2 RSLogix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E–6 t
Configure T1K–DEVNETS with RSNetWorx . . . . . . . . . . . . E–8 Using the EDS file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E–8 Go on line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E–11 Set up I/O parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E–12 Map the nodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E–15 Set Class Instance Attribute . . . . . . . . . . . . . . . . . . . . . . . . . . . E–18
Page 7
Getting Started
11
In This Chapter. . . ., Introduction, Introduction to DeviceNet, Terminator I/O System, T1K–DEVNETS DeviceNet Base Controller
Page 8
1–2
Getting Started
Getting Started
Introduction The Purpose of this Manual
This manual describes the installation and operation of the Terminator I/O DeviceNet Base Controller (T1K–DEVNETS).
Supplemental Manuals
The following manuals are essential to the proper use of your Terminator I/O DeviceNet Adapter. • Terminator Installation and I/O Manual part number T1K–INST–M This manual contains very important information, including a complete I/O Module Memory Map. The Memory Map is crucial in designing and implementing a Terminator I/O system. • The PLC/PC software manual • The DeviceNet software (if separate) manual • The DeviceNet Scanner (or Master) manual If you have a working knowledge of the DeviceNet network, the DeviceNet software and PLC or PC which you are using, this manual will help you configure and install your T1K–DEVNETS DeviceNet Base Controller.
Who Should Read this Manual
Installation and Safety Guidelines
Technical Support
We strive to make our manuals the best in the industry and rely on your feedback in reaching our goal. If you cannot find the solution to your particular application, or, if for any reason you need additional technical assistance, please call us at 770–844–4200. Our technical support team is glad to work with you in answering your questions. They are available weekdays from 9:00 a.m. to 6:00 p.m. Eastern Time. We also encourage you to visit our website where you can find technical and nontechnical information about our products and our company. www.automationdirect.com
Page 9
Introduction
1–3
The “light bulb” icon in the left-hand margin indicates a tip or shortcut.
The “note pad” icon in the left–hand margin indicates a special note.
Getting Started
Symbols Used
The “exclamation mark” icon in the left-hand margin indicates a warning or caution. These are very important because the information may help you prevent serious personal injury or equipment damage.
Key Topics for Each Chapter
The beginning of each chapter will list the key topics that can be found in that chapter.
1
Installation and Safety Guidelines