Spec sheet · B & R Automation
CPUs: CP430, CP470, CP474, CP770 and CP774
Spec sheet13 pagesPDF 1.9 MB
Data sheet for the B&R 2003 system CPUs CP430, CP470, CP474, CP770 and CP774: order data, technical data and interfaces.
Covers · 2 models
The models it covers
Summary
What is in it
B&R data sheet for the 2003 system CPU modules CP430, CP470, CP474, CP770 and CP774. It gives order data and accessories, technical data (memory, cycle times, battery buffering, interfaces), status indicators, power supply, the CAN bus and RS232 interfaces, the mode switch, updating the runtime system in System Flash, the CP interface, legend strips, data and real-time buffering, the SYS2003 system variable and how to change the backup battery.
Its parts
- 1.1 Order data
- 1.2 Technical data
- 1.3 Status indicators
- 1.4 Power supply
- 1.5 Interfaces
- 1.6 CAN bus
- 1.7 RS232 interface
- 1.8 Mode switch
- 1.9 Programming the System Flash
- 1.10 CP interface
- 1.11 Legend strips
- 1.12 Data / real-time buffering
- 1.13 System variable SYS2003
- 1.14 Changing the battery
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
B&R data sheet (V 1.10) for the System 2003 CPUs CP430, CP470, CP474, CP770 and CP774. It gives order data and accessories, technical data, status LEDs, power and interface pin assignments, mode switch settings, runtime system updates, screw-in modules for the CP474 and CP774, and battery replacement.
- Type
- System 2003 CPU with one RS232 and one electrically isolated CAN interface p. 1, 2
- CP430 (7CP430.60-1)
- CP430: 100 KB SRAM, 256 KB FlashPROM, 7 W supply, max. 64 digital / 32 analog I/O points p. 1
- CP474 (7CP474.60-2)
- CP474: 750 KB SRAM, 512 KB FlashPROM, 12.6 W supply, 4 screw-in module slots, max. 208 digital / 80 analog I/O points p. 1
- Power input
- 24 VDC rated, 18 to 30 VDC p. 3, 4
- Interfaces
- IF1 RS232, 9-pin DSUB, not isolated, 15 m at 19200 bit/s; IF2 CAN, 9-pin DSUB, isolated, 1000 m, 500 kBit/s p. 2
- Battery
- Lithium 3 V / 950 mAh button cell 4A0006.00-000 (included); 5-pack 0AC201.9 p. 1
- Programming cable
- 0G0001.00-090 RS232 online cable, PC to PLC p. 1
- CAN accessories
- 7AC911.9 bus connector (T-connector with switchable terminating resistor); 0AC912.9 and 0AC913.92 bus adapters p. 1, 5
- Screw-in modules
- CP474: analog, digital, temperature, interface (RS232, RS485/RS422, Profibus DP slave, CAN) and encoder modules; interface modules in slots 1 to 3 p. 8, 9
- PC cards
- 0MC111.9-1 2 MB FlashPROM; 0MC112.9-1 4 MB FlashPROM; 0MC211.9 2 MB SRAM p. 1
- Mode switch
- $0 boot (operating system install), $1 to $8 run, $9 to $E reserved, $F diagnostics p. 6
- Temperature
- 0 to +60°C horizontal, 0 to +50°C vertical; storage -25 to +60°C p. 3
- Panel supply
- +5 VDC, max. 500 mA on RS232 pin 4 p. 5
- Peripherals
- Hardware watchdog; real-time clock with 1 s resolution; LED status indicators p. 2
What this sheet walks you through
- Reading the status LEDs p. 3
- Connecting the power supply p. 4
- CAN bus and RS232 pin assignments p. 5
- Setting the mode switch p. 6
- Updating the runtime system with B&R Automation Studio p. 6, 7
- Fitting screw-in modules in the CP474 and CP774 p. 8, 9
- Checking battery state and I/O cycle time in the application p. 10
- Changing the backup battery p. 11, 12, 13
Good to know
- Mode switch settings $9 to $E are reserved and must not be used. p. 6
- A runtime system update clears the user flash. p. 7
- Data in RAM is lost if the battery is changed with the PLC switched off. p. 11
- Change the batteries after five years of operation. p. 11
- Do not remove the battery with uninsulated tools, which risks a short circuit. p. 12
Questions this sheet answers
What battery does the B&R CP430 use?
A 3 V / 950 mAh lithium button cell, 4A0006.00-000; one is included in delivery. p. 1
How much memory does the B&R CP474 have?
750 KB SRAM and 512 KB FlashPROM. p. 1
How do I put a CP430 into RUN mode?
Set the mode switch to a position from $1 to $8; the CPU is delivered at $0, the bootstrap loader mode. p. 6
Which cable connects a PC to the CP430 for programming?
The 0G0001.00-090 RS232 online cable; the RS232 interface is mainly intended for programming the CPU. p. 1, 5
Can the CP474 battery be changed with power on?
Yes, the design allows it either way, though some countries forbid it; changing it with the PLC off loses the data in RAM. p. 11
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 2 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file