MICRO-SCREEN Instruction Manual: For systems using control module USDINT-1T2 and USDINT-2T2 with Trip Output, pages 1 to 10

Pages 1 to 10 of 68

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Banner USDINT-2T2

Page 1

™

MICRO-SCREEN Instruction Manual For systems using control module USDINT-1T2 and USDINT-2T2 with Trip Output

MICRO-SCREEN Features • A compact, modular optoelectronic point-ofoperation guarding device for smaller light- to medium-duty production machinery • Choose sensitive Standard Series or costeffective V-Series emitters and receivers • Creates a synchronized, modulated infrared light screen in 15 sizes from 100 mm to 1.8 m (4" to 6') high • 35 mm DIN-rail-mountable control module • Control-reliable redundant output relays • Emergency Stop input • Two-digit Diagnostic Display • Easily configured one- or two-beam floating blanking • Control Module USDINT-1T2 without fixed blanking or Control Module USDINT-2T2 with fixed blanking • FMEA tested to ensure control reliability • LEDs on control module and receiver indicate system status and emitter/receiver alignment

Section Contents Section 1

MICRO-SCREEN System Introduction . . . . . .Page 4

Section 2

MICRO-SCREEN System Operation . . . . . . . .Page 7

Section 3

System Installation and Alignment . . . . . . . .Page 14

Section 4

Operating Instructions . . . . . . . . . . . . . . . . .Page 36

Section 5

Troubleshooting and Maintenance . . . . . . . .Page 38

Section 6

Alignment and Checkout . . . . . . . . . . . . . . .Page 42

9714 10th Avenue North • Minneapolis, MN 55441 Phone: 612.544.3164 • Fax: 612.544.3213 Email: sensors@baneng.com Printed in USA

P/N 48753A9C

Page 2

Applications and Limitations of MICRO-SCREEN™ Systems MICRO-SCREEN Systems are typically used in the following applications: • Small assembly equipment • Molding presses • Automated production equipment • Robotic work cells

MICRO-SCREEN Systems may NOT be used with the following machinery: • Any machine that cannot be stopped immediately after a stop signal is issued, such as single stroke (also known as “fullrevolution”) clutched machinery. • Any machine with inadequate or inconsistent machine response time and stopping performance. • Any machine that ejects materials or component parts through the defined area. • MICRO-SCREEN Systems may not be used in any environment that is likely to adversely affect photoelectric sensing system efficiency. For example, corrosive chemicals or fluids or unusually severe levels of smoke or dust, if not controlled, may degrade the efficiency of Banner MICRO-SCREEN Systems. Banner MICRO-SCREEN Systems may not be used as tripping devices to initiate machine motion (PSDI applications) on mechanical power presses, per OSHA regulation 29 CFR 1910.217. Banner Engineering Corp. 9714 - 10th Avenue No. Minneapolis, MN 55441 Phone: 612.544.3164 Fax: 612.544.3213 Email: sensors@baneng.com

2

Important ... read this page before proceeding! In the United States, the functions that Banner MICRO-SCREEN™ Systems are intended to perform are regulated by the Occupational Safety and Health Administration (OSHA). However, whether or not any particular MICRO-SCREEN System installation meets all applicable OSHA requirements depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the MICRO-SCREEN System is applied, installed, wired, operated, and maintained. Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. In addition, we suggest that any questions regarding application or use of MICRO-SCREEN Systems be directed to the factory applications department at the telephone numbers or address shown at the bottom of this page. Banner MICRO-SCREEN Systems can guard against accidents only when they are properly installed and integrated into the machine, properly operated, and properly maintained. See Section 3 of this manual for installation procedures, considerations, and precautions. See Sections 4 and 5 for operating and maintenance information. It is the responsibility of the purchaser and/or user to apply this MICRO-SCREEN System in full compliance with OSHA regulations. In addition to OSHA regulations, several other organizations provide informational material on the use of machine guard devices. The user is referred to the American National Standards Institute (ANSI), the Robotics Industries Association (RIA), the American Metal Stamping Association (AMSA), and others. Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information for a specific application. The user has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of this machine guarding system in any particular application are satisfied. Extreme care is urged to ensure that all legal requirements have been met and that all installation and maintenance instructions contained in this manual are followed.

Caution!! Banner MICRO-SCREEN Systems are for use only on machinery that can be stopped immediately after a stop signal is issued. They may be used with part-revolution clutched machines that have the ability to stop at any point in their stroke. Under no circumstances may the MICRO-SCREEN System be used on full-revolution clutched machinery. Banner MICRO-SCREEN Systems may not be used as tripping devices to initiate machine motion (PSDI applications) on mechanical power presses, per OSHA regulation 29 CFR 1910.217.

U.S. Standards Applicable to Use of MICRO-SCREEN™ Systems ANSI B11 Standards

Safeguarding of Machine Tools

ANSI/RIA R15.06

Safety Requirements for Robot Systems

NFPA 79

Electrical standard for Industrial Machinery

See page 63 and 64 for information on these and other applicable standards, and where to acquire copies.

Page 3

Table of Contents

Table of Contents 1.MICRO-SCREEN System Introduction .............................................. page 4 1.1 MICRO-SCREEN Components and Kits ................................................page 6 2.Overview of MICRO-SCREEN System Operation .................................. page 7 2.1 Blanking ................................................................................................ page 7 2.2 Auto Power-up...................................................................................... page 8 2.3 Lockout Conditions and Key Resets .................................................... page 9 2.4 Operating Status Indicators ................................................................ page 10 2.5 Diagnostic Display .............................................................................. page 11 2.6 Emergency Stop Switch Input ............................................................page 12 2.7 Output Relay Operation ...................................................................... page 12 2.8 Control Reliability: Redundancy and Self-Checking ............................page 13 2.9 Remote Test Input................................................................................page 13 3.System Installation and Alignment ................................................ page 14 3.1 Appropriate Application ...................................................................... page 14 3.2 Mechanical Installation Considerations .............................................. page 15 3.2.1 Separation Distance............................................................................ page 15 3.2.2 Hard Guarding .................................................................................... page 17 3.2.3 Emitter and Receiver Orientation ........................................................page 18 3.2.4 Adjacent Reflective Surfaces ..............................................................page 19 3.2.5 Use of Corner Mirrors..........................................................................page 19 3.2.6 Installation of Multiple MICRO-SCREEN Systems ..............................page 20 3.3 Mounting Procedure .......................................................................... page 21 3.4 Controller Board Configuration .......................................................... page 25 3.5 Electrical Hookup and Checkouts ...................................................... page 26 3.5.1 Key Reset Switch Hookup .................................................................. page 26 3.5.2 Emergency Stop Switch Hookup ........................................................page 27 3.5.3 Emitter and Receiver Hookup ............................................................ page 28 3.5.4 System Power (Temporary Connection) ............................................ page 29 3.5.5 MICRO-SCREEN System Initial Checkout .......................................... page 29 3.5.6 Output Relay Connections .................................................................. page 33 3.5.7 System Power (Permanent Connection) ............................................ page 35 3.5.8 Auxiliary Monitor Relay ...................................................................... page 35 3.5.9 Remote Test Input .............................................................................. page 35 4.Operating Instructions................................................................ page 36 4.1 Security Protocol .............................................................................. page 36 4.2 Periodic Checkout Requirements ...................................................... page 36 4.3 Normal Operation .............................................................................. page 37 5.Troubleshooting and Maintenance ................................................ page 38 5.1 Troubleshooting Lockout Conditions.................................................. page 38 5.2 Effects of Electrical and Optical Noise .............................................. page 40 5.3 Servicing and Maintenance ................................................................ page 40 5.3.1 Fuse Testing and Replacement .......................................................... page 40 5.3.2 Controller Board and Relay/Power Supply Board Replacement ........ page 40 5.3.3 Cleaning .............................................................................................. page 41 5.3.4 Warranty Service..................................................................................page 41 6.Alignment and Checkout ............................................................ page 42 6.1 MICRO-SCREEN System Alignment ....................................................page 42 6.2 Commissioning Checkout (To Be Performed at Installation) ............ page 46 6.3 Shift Change, Power-up and Machine Setup Change Checkout..........page 48 6.4 Semi-annual Checkout (To Be Performed at Six-Month Intervals) .... page 49 (Initial Checkout of MICRO-SCREEN System only on page 29) Appendix .................................................................................. page 50 Glossary of Terms ............................................................................................ page 50 Specifications .................................................................................................... page 56 Models and Accessories .................................................................................. page 60 Replacement Parts ............................................................................................page 62 Safety Standards .............................................................................................. page 63

© Banner Engineering Corp. All rights reserved.

3

Page 4

System Introduction

1. MICRO-SCREEN System Introduction The Banner MICRO-SCREEN System is a microprocessor-controlled opposed-mode optoelectronic “curtain of light” (or “light screen”). It is designed for use as a point-of-operation guarding device, and is especially suited to smaller production machinery. Banner’s microprocessor-based circuit raises the level of control reliability in machine guard design. The MICRO-SCREEN System design incorporates “diverse redundancy,” in which two microprocessors of different design, running from two different instruction sets, constantly check all system components, including each other. Banner MICRO-SCREEN Systems are extensively FMEA (Failure Mode and Effects Analysis) tested to establish an extremely high degree of confidence that no system component will ever, even if it does fail, cause a failure to danger. In typical operation, if any part of an operator’s body (or any opaque object) of more than a pre-determined cross section enters the guarded area of the machine, the output relays of the MICRO-SCREEN System will open. The contacts of the output relays are connected to the guarded machine’s primary control elements (MPCEs) which immediately stop the motion of the guarded machine. The output relays have forced-guided contacts for enhanced control reliability. Portions of the light screen may be “blanked” (made blind) to allow for: 1) The movement of one or multiple workpiece(s) through the light screen (floating blanking), or 2) The continued presence of brackets, fixtures, etc. in the plane of the light screen (optional fixed blanking). The Banner MICRO-SCREEN System is a modular machine guard system. Each System is made up of a USE Series emitter unit, a USR Series receiver unit, and a control module (see Figure 1 and cover photo). The three MICRO-SCREEN System components are interconnected using two 5-wire shielded cables. Emitters and receivers may have an attached QD connector, a 300 mm (12") QD pigtail, or an integral, unterminated 7.6 m (25') cable; units with the QD connector or pigtail also require a QD mating cable (see page 60). NOTE: The control module must be protected inside a lockable enclosure with a NEMA 3 (IP54) or better rating.

4

Figure 1. Banner MICRO-SCREEN System: emitter, receiver, control module, and two interconnecting cables

Page 5

System Introduction Emitter units have a row of synchronized modulated infrared (invisible) light emitting diodes (LEDs) in a compact rectangular metal housing. Receiver units have a corresponding row of synchronized phototransistors. Emitters and receivers are available in 15 lengths (based on the height of the defined area) ranging from 100 mm to 1.8 m (4" to 6') (see page 59). The rectangular sensor design includes a swivel bracket at each end for quick mounting and ease of alignment. Longer sensors also include one or two center brackets for additional support. Control modules and receivers have LED indicators for system operating status and alignment. Each receiver has three status indicators (visible from the front and both sides) for high visibility. Emitters have a Power ON indicator. Emitter/receiver pairs from 102 to 1219 mm (4" to 48") long may be spaced from 15 cm to 9 m (6" to 30') apart. Emitter/receiver pairs 1422 to 1892 mm (56" to 72") long may be spaced from 15 cm to 6 m (6" to 20') apart. The maximum distance between an emitter and its receiver is reduced if corner mirrors are used (see alignment information on page 48). The width and height so described are known as the defined area. The minimum object sensitivity is the minimum-diameter object that the light screen can reliably detect anywhere within the defined area. Minimum object sensitivity directly affects the minimum allowable distance between the defined area of the light screen and the nearest hazard point (the separation distance). See Section 3.2. The minimum object sensitivity is 19 mm (0.75") for Standard Series sensor lengths from 4" to 48", and 32 mm (1.25") for V-Series sensor lengths from 24" to 72" when no blanking is in use. The control module has a “trip” output which automatically resets the output relays as soon as the defined area is clear. The control module is powered by 24V dc. The control module automatically recognizes the length and style of the sensor pair wired to it – no programming is necessary. The selectable Auto Power-up feature makes a Key Reset unnecessary at system powerup when the defined area is clear.

WARNING . . . Do Not Connect Multiple Pairs of Sensors to One Control Module The MICRO-SCREEN System uses one pair of sensors connected to one control module. Connection of multiple pairs of sensors to a single control module can result in serious injury or death, and is prohibited.

The control module contains a power supply board (to power the control module itself, plus an emitter and receiver) with the forced-guided output relays, and a microprocessor controller board to control sensing logic. A two-digit Diagnostic Display on the microprocessor controller board (visible through a clear window in the control module cover) identifies one of 13 possible lockout conditions, as well as the total number of beams blocked. The control module also has provision to connect an optional Emergency Stop (E-stop) switch. Resetting the System from an emergency stop, a fault condition, or at system power-up is accomplished using a Key Reset switch, supplied with each control module. Emitter and receiver circuits are designed to meet high standards for vibration resistance. Every MICRO-SCREEN System emitter, receiver, and control module is serialized and undergoes extensive burn-in testing at the factory. Unlike some competitive systems, matched sets of MICRO-SCREEN components are not required. Any MICRO-SCREEN System emitter and receiver (of equal length and having the same number of beams) may be used together with any control module. A functional schematic diagram of the MICRO-SCREEN System appears on page 12. For MICRO-SCREEN System dimension drawings, see pages 23 and 24. For specifications, see pages 56-58. MICRO-SCREEN system components may be purchased separately, or they may be purchased bundled together in kit form. The components are listed on page 59.

5

Page 6

System Introduction

1.1 MICRO-SCREEN Components and Kits MICRO-SCREEN Systems are sold as kits which include: • • • •

A control module; An emitter and receiver of equal length and having an equal number of beams; Emitter and receiver mounting hardware, and Two cables. Cables are available in several styles depending on the type of sensors used. They may be integral, unterminated cables, 7.6 m (25') long, in which case no additional connecting cable is required. If the sensors have either a quick-disconnect fitting or the 300 mm (12") pigtail quick-disconnect, they each require a mating cable, available in one of 3 lengths.

Quick-disconnect cables are interchangeable between the emitter and the receiver if they have the same kinds of connectors. Components are also available separately (see page 60 for a complete listing). See the Banner Machine Safety Products Catalog or price list for a complete list of available kits.

6

Page 7

System Overview

Fixed Blanking ON Beams of Defined Area

2. Overview of MICRO-SCREEN System Operation In operation, an emitter and receiver (of equal length) are mounted and aligned opposite each other. This establishes a curtain of invisible infrared light beams called the defined area (Figure 1). Center-to-center spacing between adjacent light beams is 12.7 mm (0.5") for 102 to 1219 mm (4" to 48") emitter and receiver lengths, and 25.4 mm (1.0") for V-Series 610 to 1892 mm (24" to 72") long.

Workpiece

Press Break Die

Fixed Blanked beams

Fixed Blanking OFF

Individual features of the MICRO-SCREEN System are discussed in the following subsections: • Blanking (Section 2.1) • Auto Power-up (Section 2.2) • Lockout Conditions and Key Resets (Section 2.3) • Operating Status Indicators (Section 2.4) • Diagnostic Display (Section 2.5) • Emergency Stop Switch Input (Section 2.6) • Output Relay Operation (Section 2.7) • Control Reliability: Redundancy and Self-checking (Section 2.8) • Remote Test Input (Section 2.9)

Beams of Defined Area

2.1 Blanking The MICRO-SCREEN System features floating blanking and optional fixed blanking (if control module model USDINT-2T2 is used); see Figure 2. Fixed blanking allows fixed objects (such as brackets, fixtures, etc.) to be ignored in the defined area, as long as they never move or change size. Workpiece Press Break Die

Figure 2. Floating blanking

Fixed blanking requires an emitter and receiver with 16 or more light beams (see page 59). Fixed blanking is easy to set up. With the object(s) to be ignored in place, the user “teaches” the controller which beams to blank by simply pushing a button located inside the control module. The Diagnostic Display will indicate the total number of blanked beams. Fixed blanking is limited to 30% of the total number of beams in the array, up to a maximum of 12 beams. Contact the factory Applications Department if your application requires fixed blanking of a greater number of beams. Blanking information is stored in non-volatile memory to prevent setup loss when power is removed. Once fixed blanking is programmed, removing or moving any fixed object within the defined area will cause a lockout condition (see Section 2.3). See pages 26 and 31 for programming information. Floating blanking is the “blinding” of one or two sensing beams which will appear to change position (“float”) in order to allow one or more objects (usually workpiece materials) to move through the defined area, at any point, without tripping the final switching device relays (FSDs) of the MICRO-SCREEN System. There is the choice of either one-beam or two-beam floating blanking. The ignored object size and resultant minimum object sensitivity are listed in the table on page 8.

7

Page 8

System Overview

Minimum Object Sensitivity Standard Series Sensors

V-Series Sensors

Floating Blanking Program

Maximum Size of Undetected Objects

Minimum Object Sensitivity

Maximum Size of Undetected Objects

Minimum Object Sensitivity

OFF

(Not applicable)

19.1 mm (0.75")

(Not applicable)

31.8 mm (1.25")

1-beam

7.6 mm (0.30")

31.8 mm (1.25")

20.3 mm (0.80")

57.5 mm (2.25")

2-beam

20.3 mm (0.80")

44.5 mm (1.75")

45.7 mm (1.80")

82.6 mm (3.25")

NOTES: 1) The size listed in the table for objects which move undetected through the light screen assumes that those objects move through the screen exactly perpendicular to the plane of the light beams. 2) Control module USDINT-1T2, without fixed blanking: Selecting one- or two-beam floating blanking will affect the overall minimum object sensitivity, which allows multiple objects to move through the defined area (see table, above). This is also called “reduced resolution” or “multiple-point floating blanking.” 3) Control module USDINT-2T2, with fixed blanking: When fixed blanking is not enabled, selecting one- or two-beam floating blanking will affect the overall minimum object sensitivity, which allows multiple objects to move through the defined area. When fixed blanking is used, selecting one- or two-beam floating blanking will create a single “hole” in the sensing field, which allows a single object of a certain size to move through the defined area without being detected (see table, above). In all cases, when floating blanking is selected, the resultant worst case minimum object sensitivity (sometimes called minimum object detection size or MODS) must be used to calculate separation (safety) distance (see Section 3.2.1). The minimum object sensitivity is the minimum diameter of an object that the light screen can reliably detect anywhere within its defined area. Minimum object sensitivity directly affects the minimum allowable distance between the defined area of a light screen and the nearest hazard point (the separation distance). See section 3.2. Floating blanking preference is set via a pair of DIP switches on the controller board inside the control module (see Figure 20 and section 3.4, both on page 25, for details). Note: Blanking ON is indicated by a flashing green status indicator.

2.2 Auto Power-up Normal operation of the MICRO-SCREEN System requires a Key Reset each time power is applied to the system. This is usually a desired response to a power failure or interrupt, and is required by some design standards. In applications where the machine control circuits are used to power up a series of machines, selecting the Auto Powerup feature puts the MICRO-SCREEN System directly into RUN mode when power is applied and the defined area is clear. See WARNING, at right. Auto Power-up is enabled or disabled via a pair of configuration DIP switches located on the controller board inside the control module. See Figure 20 and Section 3.4 on pages 25 and 26 for details.

8

WARNING . . . Use of Auto Power-up Application of power to the MICRO-SCREEN System must NOT initiate dangerous machine motion. Machine control circuitry must be designed so that one or more initiation devices be engaged to start the machine, after the MICROSCREEN is placed in RUN mode.

Page 9

System Overview

2.3 Lockout Conditions and Key Resets A lockout condition of the MICRO-SCREEN System causes all of its output relays to open, sending a “stop” signal to the guarded machine. A lockout condition will occur: Power-up/Power Interrupt Lockouts •

Routinely upon power-up of the MICRO-SCREEN System (unless Auto Power-up is ON; see Figure 5, page 10); or

•

If power to the MICRO-SCREEN System is interrupted (unless Auto Power-up is ON; see Figure 5). Internal Lockout Conditions •

If the Control Module Key switch is in the RESET position, at power-up, (with Auto Power-up ON); or if the Key switch is switched to RESET while the System is in the RUN mode;

•

If the Program/Run switch (Figure 20) is in the PROGRAM position at power-up;

•

If Floating Blanking switches are in the ON position when Program/Run switch is switched to the PROGRAM position;

•

If both 1-beam and 2-beam Floating Blanking switches are in the ON position;

•

If fixed blanking is NOT SET within approximately 4 minutes of moving the Program/Run switch to the PROGRAM position;

•

If fixed blanking has been programmed, and any fixed object is removed from or moved within the defined area;

•

If an FSD (Final Switching Device – see Glossary) relay does not “drop out” within its specified time;

•

If the SSD (Secondary Switching Device – see Glossary) relay has de-energized;

•

If the control module switch settings are inconsistent with each other or if they are changed while the system is in RUN mode;

•

If the self-checking circuits of the microprocessor detect a component failure within the MICRO-SCREEN System itself; or

•

If either (or both) Emergency Stop switch contacts open.

A lockout condition resulting from an internal system fault is indicated by a flashing red status indicator on the control module and the receiver unit. The green and yellow status indicators will be OFF. See Figure 5, page 11. Power-up/power interrupt lockouts (Auto Power-up OFF, conditions as indicated above, yellow status indicator only double-flashing) are normal and require a Key Reset for operation to continue. Internal lockout conditions result from component failures or incorrect controller settings, which must be corrected before the system will allow operation to continue (Section 2.8). A Diagnostic Display (located inside the control module on the controller board, and visible through a window in the control module cover) will indicate the cause of the lockout (Section 2.5). Internal lockout conditions also require a reset of the Key switch (a Key Reset) to return the system to RUN mode. To perform a Key Reset, turn the Key switch clockwise to the RESET position, hold it there for at least 1/2 second, and then return the Key switch to the RUN position.

9

Page 10

System Overview

2.4 Operating Status Indicators The control module and the receiver have the following operating status indicators (see Figures 3 and 4): green (CLEAR), red (BLOCKED), and yellow (RESET). Their indications are as follows: Red ON steadily and Yellow single-flashing* (Blocked): the MICRO-SCREEN System has been reset and is in RUN mode, but either there is an obstruction in the defined area or the emitter and receiver are misaligned. FSD1 and FSD2 contacts are open (de-energized). SSD relay is closed (energized). A flashing yellow status indicator displays sensor alignment. The faster the flash rate, the more beams are “made,” and the fewer beams are blocked or “not made.” This feature is very helpful for emitter/receiver alignment (Section 6.1). When alignment is correct, the green indicator will come ON (to join yellow) when the obstruction is removed. If alignment is not correct, the green indicator will remain OFF when the obstruction is removed. Green** and Yellow ON steadily: the MICRO-SCREEN System has been reset and is in RUN mode, the defined area is clear of obstructions, and the emitter and receiver are properly aligned. SSD, FSD1, and FSD2 contacts are closed (energized). Red (only) ON and flashing: a lockout condition exists, due to an internal MICROSCREEN System problem. SSD, FSD1, and FSD2 are all open (de-energized).

Indicator

ON Steadily Flashing

Green Red Yellow

CLEAR BLOCKED RESET

BLANKING LOCKOUT ALIGNMENT

(Three sides of receiver) See also Figure 5, page 11.

Figure 3. Status indicators (receiver)

Yellow (only) ON and double-flashing: a double-flashing yellow status indicator indicates a power-up or power interrupt lockout condition. These lockouts occur in the normal course of powering up the MICRO-SCREEN System or upon an interruption of power to the System (unless Auto Power-up is ON; see page 26). SSD, FSD1 and FSD2 contacts are open (de-energized). MI MO

Yellow (only) ON steadily: the Key switch has been switched to the RESET position at power-up. FSD1 and FSD2 contacts are open (de-energized). SSD contact is closed (energized).

DE

CR

L NO

.U

O-

SD

SC

INT

-2T

2

RE

EN CA UT IO ma N

Sh ock haza rd y ex ist.

R

LIST PresED Sensence Devi ing 10Y8ce

C R

046

6 op For WA era co R ins tion ntrol NIN tru alw rel ction ay iab G s in s fol le Bloc the low ma the ked nu al. Clea Lock r ou Rese Blan t STEA t Al king DY ignm BA FLAS ent NN ER HING EN GI

US

Diag

Diagnostic Display no stic

A (61 NEER 2) 54 ING 4-3 CORP 164 . Ch art on

Re vers e Si de

Red Yellow Green

Figure 4. Control module indicator LEDs

*

If the Test Input terminals are shorted and the defined area is clear, the yellow status indicator will be ON steadily (see Section 3.5.9).

** A flashing green status indicator indicates fixed and/or floating blanking is ON. 10