For the Banner USDINT-2T2

Page 11

System Overview

Operation Mode

Normal Operation

Power Up

Apply Power to Control Module LOCKOUT STATE

Turn Key to RESET Position

Indicator Status

Relay Status

BLOCKED Red

CLEAR Green

RESET Yellow

FSD1

FSD2

SSD

Alarm

Red

Green

Yellow

FSD1

FSD2

SSD

Alarm

Key Reset Turn Key to RUN Position

Run

Defined Area Is CLEAR

If Auto Power-up is ON when power is applied to the MICROSCREEN System, the controller will perform an automatic RESET after passing an internal system checkout (Key RESET not needed). Auto Power-up is discussed in Section 3.4. NOTE: A Key RESET is always required to recover from a LOCKOUT condition. Red

Yellow

FSD1

FSD2

SSD

Alarm

Yellow**

FSD1

FSD2

SSD

Alarm

**Yellow will be OFF if the system is powered up without alignment Red Green Yellow

FSD1

FSD2

SSD

Alarm

*Green will flash if blanking is ON. Red

Symbol Definitions Indicator OFF

Indicator ON steadily Indicator single-flashing

Defined Area Is BLOCKED

Internal System Fault (LOCKOUT)

Green*

Green

Indicator double-flashing

Figure 5. Operating status conditions

2.5 Diagnostic Display A two-digit numeric display, visible through a clear window in the MICRO-SCREEN control module cover, makes system troubleshooting an easy task. • It indicates an error code corresponding to the cause of a fault (lockout) condition. Error codes are listed and interpreted in Figure 25 on page 39. • During programming of fixed blanking (control module model USDINT-2T2), it indicates the number of blanked beams. • During normal operation, it indicates the total number of blocked beams, including fixed blanked beams. • In addition, the decimal point of the display will flash to indicate a high level of electrical or optical interference in the area of the MICRO-SCREEN System. • Under normal RUN conditions, and with no beams blocked, the right-hand digit will display a horizontal bar (the center segment of the display will be lit).

11

Page 12

System Overview

2.6 Emergency Stop Switch Input The MICRO-SCREEN control module has a provision for the connection of an optional Emergency Stop switch. See Section 3.5.2 for complete information.

2.7 Output Relay Operation The MICRO-SCREEN System control module has three output relays (see Figure 6 below), labeled “FSD1,” “FSD2,” and “SSD.” The contacts of the Final Switching Device (FSD) relays (FSD1 and FSD2) are connected to the Machine Primary Control Elements (MPCEs) of the guarded machine. An MPCE is an electrically powered element of the guarded machine that directly controls the machine’s normal operating motion so that it is last (in time) to operate when motion is either initiated or arrested. The Secondary Switching Device (SSD) relay contacts are connected to the guarded machine’s Machine Secondary Control Element (MSCE), an electrically powered element of the guarded machine (independent of both MPCEs) that is capable of removing power from the prime mover of the dangerous part of the machine in the event of a system fault. The two MPCEs must each (alone) be capable of stopping the motion of the guarded machine in an emergency. The opening of any FSD1, FSD2, or SSD relay contact results in the removal of power to either an MPCE or MSCE (or both), which will stop the motion in the guarded machine. Any object that blocks one or more unblanked beams will be detected, and will cause a trip condition: output relays FSD1 and FSD2 (but not SSD) in the control module open their contacts. All three output relays (FSD1, FSD2, and SSD) will open their contacts in response to any one or more lockout conditions, including component failure within the MICRO-SCREEN System itself (see Control Reliability, Section 2.8). The MICRO-SCREEN System automatically resets itself from a trip condition when the object that caused the trip is removed. Internal lockout conditions require a Key Reset to return the system to RUN mode. (To perform a Key Reset, turn the Key switch clockwise to the RESET position, hold it there for at least 1/2 second, and then return the Key switch to the RUN position.) The AUX Non-Safety Output is a separate relay intended for non-safety-related purposes. It is typically used to signal a programmable logic controller (PLC) when output relay contacts FSD1 and FSD2 open or close. See Section 3.5.8 for more information. Figure 6. Banner MICRO-SCREEN System functional schematic

12

Page 13

System Overview

2.8 Control Reliability: Redundancy and Self-checking MICRO-SCREEN Systems meet certain U.S. and international control reliability standards for safety. Banner MICRO-SCREEN Systems must reliably send a “stop” signal to a guarded machine as follows: 1) The MICRO-SCREEN System must provide a “stop” signal to the guarded machine, within 38 milliseconds, whenever the defined area is interrupted. In order for the machinery guarded by the MICRO-SCREEN System to be stopped as described, the guarded machine must be capable of stopping at any point in its machine cycle. This means that the MICRO-SCREEN System cannot be used with certain types of machinery, such as single stroke (also known as “full-revolution” clutched) machinery, or any machine with inconsistent machine response time and stopping performance. If there is any doubt about whether or not your machinery is compatible, contact the Banner Factory Application Engineers. 2) The MICRO-SCREEN System must provide a “stop” signal to the guarded machine when internal component failures have occurred which compromise the integrity of the MICRO-SCREEN System itself. This type of component failure includes any internal MICRO-SCREEN System failure which could prevent or delay the output relays of the MICRO-SCREEN System from going to a trip condition or a lockout condition in response to a situation which, in normal operation, would cause them to do so. The ability of the MICROSCREEN System to send a “stop” signal even when such a component failure has occurred depends upon its redundant design. Redundancy requires that MICRO-SCREEN System circuit components be “backed up” to the extent that, if the failure of any single component will prevent effective stopping action when needed, that component must have a redundant counterpart which will perform the same function. The microprocessor-controlled MICRO-SCREEN System is designed with diverse redundancy. Diverse redundant components are of different designs, and microprocessor programs used by them run from different instruction sets. Redundancy must be maintained for as long as the MICRO-SCREEN System is in operation. Since a redundant system is no longer redundant once a component has failed, MICRO-SCREEN Systems are designed to be continuously self-checking. A component failure detected by or within the self-checking system causes a “stop” signal to be sent to the guarded machine and puts the MICRO-SCREEN System into a lockout condition. Recovery from this type of lockout condition requires replacement of the failed component (to restore redundancy) and a Key Reset (see page 12). Possible causes are listed in Section 2.3. The Diagnostic Display is used to diagnose internal causes of a lockout condition (Section 5.1).

2.9 Remote Test Input A pair of terminals is provided (see Figure 21, page 28) for an external normally open switch. These terminals are labeled “TEST 1” and “TEST 2.” Closing a switch connected between these two terminals simulates an interruption of one of the light beams. The device used must be capable of switching from 15 to 50V dc at 20 to 100 mA. The switch must be held closed for a minimum of 0.05 seconds to guarantee system response. This remote test input is sometimes useful for system setup and checkout procedures.

13

Page 14

System Installation and Alignment

3. System Installation and Alignment 3.1 Appropriate Application The MICRO-SCREEN System may only be used to guard machinery that is capable of stopping motion immediately upon receiving a stop signal and at any point in its machine cycle. The MICRO-SCREEN System may not be used for the following: •

With single stroke (also called “full revolution”) clutched machinery, as this type of machinery is incapable of stopping immediately.

•

On certain other types of machinery, including any machine with inadequate or inconsistent stopping response time, or any machine that ejects materials or component parts through the defined area.

•

In any environment likely to adversely affect the efficiency of a photoelectric sensing system. For example, corrosive chemicals or fluids or unusually severe levels of smoke or dust, if not controlled, may degrade the efficiency of the MICRO-SCREEN System.

•

As a tripping device to initiate machine motion (PSDI applications) on mechanical power presses, per OSHA regulation 29 CFR 1910.217.

CAUTION . . . Install System Only on Appropriate Applications In order for the machinery guarded by the MICRO-SCREEN System to be stopped as described, that machinery must be capable of stopping at any point in its machine cycle. This means that the MICRO-SCREEN System cannot be used with certain types of machinery (see listing above). If there is any doubt about whether or not your machinery is compatible with the MICRO-SCREEN System, contact Banner’s Application Engineers at the factory.

WARNING . . . Installation of MICROSCREEN Systems with Trip Output for Perimeter Guarding Applications The control modules described in this manual produce a “trip” output which automatically resets the output relays as soon as the defined area is clear. Use of a trip output is dangerous for perimeter guarding applications where it is possible for personnel to move through the defined area and locate themselves inside the guarded area of dangerous machine motion. Banner offers control modules with “latching” output response, which are designed for perimeter guarding applications. See the Banner Machine Safety Products catalog or contact the Banner Factory Applications Engineers for information on control modules with latching response. If a control module with trip output response is used for a perimeter guarding application, the following conditions must be met: 1)

The dangerous machine motion must be able to be initiated following an interruption of the defined area only after actuation of a Reset switch.

2)

The Machine Primary Control Elements (MPCEs) of the guarded machine must be wired so that the FSD outputs of the control module cause a latched response of the MPCEs.

3)

The MPCEs must be reset only by actuation of a Reset switch. The Reset switch must be located outside the area of dangerous motion, and must be positioned so that the area of dangerous motion may be observed by the switch operator during the Reset operation.

WARNING . . . Read this Section Carefully Before Installing the System The Banner MICRO-SCREEN System is a point-of-operation machine guarding device. Its ability to perform this function depends upon the appropriateness of the application and upon the MICRO-SCREEN System’s proper mechanical and electrical installation and interfacing to the machine to be guarded. If all mounting, installation, interfacing, and checkout procedures are not followed properly, the MICRO-SCREEN System cannot provide the protection for which it was designed. The user has the responsibility to ensure that all local, state, and national laws, rules, codes, or regulations relating to the installation and use of this control system in any particular application are satisfied. Extreme care should be taken to ensure that all legal requirements have been met and that all technical installation and maintenance instructions contained in this manual are followed. Read Section 3 (and its subsections) of this manual carefully before installing the system. Failure to follow these instructions could result in serious bodily injury or death. The user has the sole responsibility to ensure that the Banner MICRO-SCREEN System is installed and interfaced to the guarded machine by Qualified Persons in accordance with this manual and applicable safety regulations. A “Qualified Person” is defined as “a person or persons who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training, and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work” (ANSI/ASME B30.2-1983).

14

Failure to observe this warning could result in serious bodily injury or death.

Page 15

System Installation and Alignment

WARNING . . . Position Components Carefully The emitter and receiver must be positioned such that the hazard can not be accessed by reaching over, under, around or through the sensing field. Additional guarding may be required; see Hard Guarding, Section 3.2.2.

WARNING . . . Proper Separation Distance Banner MICRO-SCREEN System emitters and receivers must be mounted at a distance from moving machine parts that is determined by OSHA standards found in Section 1910.217 (c)(3)(iii)(e). Failure to establish and maintain the required separation distance exactly as described in Section 3.2 of the MICRO-SCREEN manual could result in serious bodily injury or death.

WARNING . . . Determine Correct Stop Time The measurement of stop time (Ts) must include the response time of all devices or controls that react to stop the machine. If all devices are not included, the calculated separation distance (Ds) will be too short. This can lead to serious bodily injury or death. Be sure to include the stop time of all relevant devices and controls in your calculations.

CAUTION . . . Proper Installation When Using Floating Blanking Floating blanking increases Dpf (see values at right). You must increase the penetration factor to calculate the separation distance whenever floating blanking is used. Always turn floating blanking OFF when the larger minimum object detection size is not required.

3.2 Mechanical Installation Considerations Two factors have the greatest influence on the layout of the MICRO-SCREEN System’s mechanical installation: • Separation distance, and • Hard guarding.

3.2.1 Separation Distance The MICRO-SCREEN System must be able to react fast enough, when a hand or other object is inserted into the defined area, to send a “stop” signal to the guarded machine before the object or hand reaches the closest reachable hazard point on the machine. The separation distance (or safety distance) is the minimum distance that is required between the midpoint of the defined area and the closest reachable hazard point. The actual separation distance required depends upon several factors, including the speed of the hand (or object), the total system stopping time (of which there are several response time components), and the depth penetration factor. The formula used to calculate the separation distance is:

Ds = K x (Ts + Tr ) + Dpf where: Ds = the separation distance; K = the OSHA-recommended hand speed constant of 63" per second (NOTE 1, below); Ts = the overall stop time of the machine measured from the application of the “stop” signal to the final ceasing of all motion (including stop times of all relevant control elements, and measured at maximum machine velocity). See the WARNINGs (left), NOTE 2 (below), and the NOTICE Regarding MPCEs (page 33). Tr = the response time of the MICRO-SCREEN System: .038 seconds Dpf = the added distance due to depth penetration factor, as prescribed in OSHA 1910.217 and ANSI B11 standards: Floating Blanking

Standard Series Sensors

V-Series Sensors

Floating blanking OFF

Dpf = 1.6"

Dpf = 3.3"

1-beam blanking ON

Dpf = 3.3"

Dpf = 6.7"

2-beam blanking ON

Dpf = 5.0"

Dpf = 31.5"

NOTES: 1) The OSHA-recommended hand-speed constant K has been determined by various studies, and although these studies indicate speeds of 63 in/sec to more than 100 in/sec, they are not conclusive determinations. The employer should consider all factors, including the physical ability of the operator, when determining the value of K to be used. 2) Ts is usually measured by a stop-time measuring device. If the specified machine stop time is used, we recommend that at least 20% be added as a safety factor to account for clutch/brake system deterioration. 3) Use of floating blanking will always cause the required Ds to increase.

15

Page 16

System Installation and Alignment

WARNING . . . V-Series Sensors Require Greater Separation Distance The beam spacing for V-Series emitters and receivers is greater than for standard sensors. This means that the minimum object sensitivity is greater and also the resulting depth penetration factor (Dpf) used to calculate the separation distance is greater for V-Series sensors (see Dpf value chart on page 15). Carefully check the labels on the emitter and receiver to determine the proper value of Dpf to use in the separation distance formula. Insufficient separation distance will result in an unsafe installation.

Figure 7. Separation distance

Example: Separation Distance (Ds) Calculation The following example shows how to use the formula from page 15 to calculate separation (safety) distance (Ds). We will use these numbers for the variables in the formula: K = 63 inches per second (the hand speed constant set by OSHA) Ts = .250 second (the total stop time of the example machine, specified by machine manufacturer) Tr = .038 second (the specified response time of the MICRO-SCREEN System) Our example uses two-beam floating blanking with a 24" standard emitter and receiver, so we use a Dpf of 5" (page 15). Response time for this example is .038 second. Substitute the numbers into the formula as follows: Ds = K x (Ts + Tr) + Dpf Ds = 63 x (.250 x 1.2* + .038) + 5 = 26" Therefore, in this example, the MICRO-SCREEN emitter and receiver must be mounted so that no part of the defined area will be closer than 26" to the closest reachable hazard point on the guarded machine. *20% safety factor (see NOTE 2, page 15)

16

Page 17

System Installation and Alignment

3.2.2 Hard Guarding WARNING . . . The Point of Operation Must be Accessible Only Through the Defined Area Mechanical barriers (screens, bars, etc.), or supplemental presence sensing devices (supplemental guarding) must be installed, wherever needed, to prevent any person from reaching around, under, or over the defined area and into the point of operation, and also to prevent any person from entering the space between the defined area and the point of operation (see OSHA 1910.212). The use of mechanical barriers for this purpose is called “hard guarding.” There must be no gaps between the hard guarding and the edges of the defined area. Openings in the hard guard material must meet OSHA criteria (see OSHA 1910.217, Table O-10).

ANSI B11.1-1988, 6.3.2 (14) requires that “all areas of entry to the point of operation not protected by the presence-sensing device shall be otherwise safeguarded.” The hazard point must be accessible only through the defined area. This means that mechanical barriers (screens, bars, etc.), or supplemental presence sensing devices (supplemental guarding) must be installed, wherever needed, to prevent any person from reaching around, under, or over the defined area and into the hazard point. The use of mechanical barriers for this purpose is called “hard guarding” (see the WARNING at left and Figure 8, below). There must be no gaps between the hard guarding and the edges of the defined area. Furthermore, fixed objects in the defined area which require use of fixed banking must occupy the entire width of the defined area. Otherwise, hard guarding must be installed to prevent access to any hazard point through the blanked area.

Supplemental presence-sensing devices, such as safety mats, must be used if the space between the defined area and the nearest danger point is large enough to allow a person to stand undetected by the MICRO-SCREEN System. Failure to do so could result inserious bodily injury or death.

Hazard Area

Defined Area

Hard Guard

Hard Guards

Hard Guard

Figure 8. Example of hard guarding

17

Page 18

System Installation and Alignment

3.2.3 Emitter and Receiver Orientation It is absolutely necessary that the emitter and receiver are mounted perfectly parallel to each other and aligned in a common plane with both cable ends pointing in the same direction. Never mount the emitter with its cable end oriented opposite to the cable end of the receiver, or there will be voids in the light curtain through which objects can pass undetected (see Figure 10a). The emitter and receiver may be oriented in a horizontal plane, or at any angle between horizontal and vertical. However, the cable ends must always point in the same direction. Always be certain that the light screen completely covers all access to the hazard point which is not already protected by hard guarding or another means of supplemental guarding.

c) a)

Both cable ends down b)

Both cable ends up

Oriented parallel to floor, with both cable ends pointing in the same direction

Figure 9. Correct emitter and receiver orientation a)

Cable ends point in opposite directions. Problem: Voids in defined area.

b)

Emitter and receiver not parallel to each other. Problem: Reduced excess gain

Figure 10. Incorrect emitter and receiver orientation

18

WARNING . . . Proper Orientation of System Emitters and Receivers The emitters and receivers of the MICRO-SCREEN System must be installed with their corresponding ends (either cabled ends or non-cabled ends) pointing in the same direction (both cabled ends “up,” both cabled ends “down,” etc.). Failure to do this will impair the performance of the MICROSCREEN System and result in incomplete guarding; see Figure 10a. Failure to observe this warning could result in serious bodily injury or death.

Page 19

System Installation and Alignment

WARNING . . . Installation Near Reflective Surfaces A highly reflective surface (such as a shiny machine surface or a shiny workpiece) may reflect sensing light around an object in the defined area, preventing that object from being detected. This potentially dangerous condition is discovered using the “trip test” as described in the Initial Checkout Procedure (Section 3.5.5), the Alignment Procedure (Section 6.1), and the periodic checkout procedures (Sections 6.2, 6.3, and 6.4).

3.2.4 Adjacent Reflective Surfaces A reflective surface located adjacent to the defined area may deflect one or more beams of the light screen around an object which is in the defined area. In the worst case, an object may pass through the defined area undetected. A reflective surface may be a part of the machine or the workpiece and may include shiny metal or plastic or surfaces with glossy paint. Where possible, reflective surfaces adjacent to the defined area should be roughened or covered with a dull material. Where this is not possible (as with a reflective workpiece), the sensor mounting should include a means of restricting the field of view of the receiver or the spread of the light from the emitter. Beams deflected by reflective surfaces are discovered during the initial checkout procedure (Section 3.5.5), the final alignment and checkout procedure (Section 6.1), and also by the periodic checkout procedures (Sections 6.2, 6.3, and 6.4).

When this condition is discovered, eliminate the problem reflection(s): • If possible, relocate the sensors to move the light screen beams away from the reflective surface(s), being careful to retain at least the required separation distance (Section 3.2.1). • Otherwise, paint, mask, or roughen the interfering shiny surface to reduce its reflectivity.

3.2.5 Use of Corner Mirrors MICRO-SCREEN sensors may be used with one or more corner mirrors. The use of corner mirrors somewhat reduces the maximum specified emitter/receiver separation. (See page 45.) Corner mirrors and stands are available from Banner. Contact the factory Applications Engineering Department for information, or see page 61.

Repeat the trip test to verify that these changes have eliminated the problem reflection(s). (NOTE: If the workpiece is especially reflective and comes close to the light screen, perform the trip test with the shiny workpiece in place.)

WARNING . . . Avoid Retroreflective Installation Never use MICRO-SCREEN sensors in retroreflective mode, as illustrated in Figure 11. The MICRO-SCREEN System is not designed for use in retroreflective mode (where the sensors are mounted adjacent to each other and the light from the emitter is bounced back directly to the receiver by a mirror or other reflective surface). Sensing is unreliable in this mode and could result in serious injury or death.

Figure 11. Never use MICRO-SCREEN sensors in retroreflective mode.

19

Page 20

System Installation and Alignment

3.2.6 Installation of Multiple MICRO-SCREEN Systems Whenever the emitter and receiver pairs of two or more MICRO-SCREEN Systems are located adjacent to one another, there is potential for optical crosstalk to take place between systems. To minimize optical crosstalk, it is recommended to alternate emitters and receivers, as shown in Figure 12.

a)

Two systems in a horizontal plane.

b)

c)

Two systems stacked.

Two systems at right angles.

Figure 12. Installation of multiple MICRO-SCREEN systems. Alternate emitters and receivers to avoid optical crosstalk.

When three or more systems are installed in a horizontal plane, (as shown for two pairs in Figure 12a), optical crosstalk may occur between sensor pairs whose emitter and receiver lenses are oriented in the same direction. In this situation, optical crosstalk may be controlled by mounting these sensor pairs exactly in line with each other within one plane, or by adding a mechanical light barrier between the pairs.