Page 21

System Installation and Alignment

3.3 Mounting Procedure Sensor Mounting Banner MICRO-SCREEN System emitters and receivers are small, lightweight, and easy to handle during mounting. The mounting brackets (supplied) allow ±30º rotation. Emitter/receiver pairs from 102 to 1219 mm (4" to 48") long may be spaced from 15 cm to 9 m (6" to 30') apart. Emitter/receiver pairs 1422 to 1892 mm (56" to 72") long may be spaced from 15 cm to 6 m (6" to 20') apart. The maximum distance between an emitter and its receiver is reduced if corner mirrors are used (see alignment information, page 45). From a common point of reference, make measurements to locate the emitter and receiver in the same plane with their midpoints directly opposite each other. Important: The connector ends of both sensors must point in the same direction (see drawings and WARNING, page 18). Mount the emitter and receiver brackets using M6 bolts and Keps nuts (all supplied); see Figure 14. Mount the emitter and receiver in their brackets and position the windows of the two units directly facing each other. Measure from one or more reference planes (e.g., the building floor) to the same point(s) on the emitter and receiver to verify their mechanical alignment. If the units are positioned exactly vertical or horizontal to the floor, a carpenter’s level is useful for checking alignment. A straightedge or a string extended between the sensors also helps with positioning. Also check “by eye” for line-of-sight alignment. Make any necessary final mechanical adjustments, and hand-tighten the bracket hardware. A detailed alignment procedure is given in Section 6.1. Center Bracket Mounting Center mounting brackets must be used with longer sensors to provide sensor stability. Sensors 40" to 48" long are supplied with one center bracket, which should be positioned at the center of the sensor’s length. Sensors 56" to 72" long are supplied with two center brackets, which should be positioned 1/3 of the sensor’s length from each sensor end (see Figure 14). Refer to Figure 14 for the following steps. 1) Spread the clamp and snap over the back of the sensor so that the clamp is securely fastened to the sensor without blocking any beams.

Slots have Clearance for M3 Screws (supplied) and Allow for ±30º Rotation

12.7 mm (0.50")

15.7 mm (0.63")

15.7 mm (0.63")

23.2 mm (0.92")

ø15.2 mm (0.60")

26.7 mm (1.05")

Min. Radius

2.3 mm (0.09")

10.7 mm (0.41") 5.8 mm (0.23") 20.0 mm 31.87 mm (0.79") (1.25")

7.1 mm 2x R 6.4 mm (0.28") (0.25") 2x ø4.8 mm 14.0 mm (0.19") (0.54") 27.2 mm (1.07") Material: Cold Rolled Steel Finish: Black, Zink Plated, Chromate Dip

42.4 mm (1.67")

Figure 13. Emitter and receiver mounting bracket dimensions

21

Page 22

System Installation and Alignment 2) Compress the foam spacer and slide the clamp along the length of the sensor housing to align the clamp with the center mounting bracket as shown in Figure 14. Three separate mounting holes are provided on the clamp to allow for all possible mounting configurations. 3) Connect the clamp to the center bracket using the M3 screw supplied. 4) Loosen all the mounting screws to the sensor, align the sensors and then tighten the end screws. Finally, tighten the M3 screw joining the clamp to the center mounting bracket.

4" to 36" Emitters and Receivers MICRO-SCREEN Mounting Hardware

40" to 72" Emitters and Receivers* MICRO-SCREEN Mounting Hardware

(supplied with each emitter and receiver)

(supplied with each emitter and receiver)

NOTE: MICRO-SCREEN sensor brackets are designed to mount directly to MSA Series stands (page 61), using the hardware supplied with the stands.

Figure 14. Emitter and receiver mounting

22

* 40" to 48" sensors include one center bracket and clamps to be located at the midpoint along the sensor’s length 56" to 72" sensors include two center brackets and clamps to be located at 1/3 of the sensor’s length from each end (as shown here).

Page 23

System Installation and Alignment

25.4 mm (1.00")

31.8 mm (1.25")

L2 (Defined Area)

Y L1

L3

27.9 mm (1.10") 17.0 mm (0.67")

Figure 15. Emitter and receiver mounting dimensions and location of defined area

Standard Models Emitter USE424 Receiver USR424 Emitter USE824 Receiver USR824 Emitter USE1224 Receiver USR1224 Emitter USE1624 Receiver USR1624 Emitter USE2024 Receiver USR2024 Emitter USE2424 Receiver USR2424 Emitter USE2824 Receiver USR2824 Emitter USE3224 Receiver USR3224 Emitter USE3624 Receiver USR3624 Emitter USE4024 Receiver USR4024 Emitter USE4424 Receiver USR4424 Emitter USE4824 Receiver USR4824

V-Series Models

Emitter USE2412 Receiver USR2412

Emitter USE3212 Receiver USR3212

Emitter USE4012 Receiver USR4012

Emitter USE4812 Receiver USR4812 Emitter USE5612 Receiver USR5612 Emitter USE6412 Receiver USR6412 Emitter USE7212 Receiver USR7212

Housing Length L1

Distance Between Bracket Holes L2 L3

Defined Area Y

137 mm (5.4")

171 mm (6.7")

108 mm (4.2")

102 mm (4")

239 mm (9.4")

273 mm (10.7")

209 mm (8.2")

203 mm (8")

340 mm (13.4")

374 mm (14.7")

311 mm (12.2")

305 mm (12")

442 mm (17.4")

476 mm (18.7")

412 mm (16.2")

406 mm (16")

544 mm (21.4")

578 mm (22.7")

514 mm (20.2")

508 mm (20")

645 mm (25.4")

679 mm (26.7")

616 mm (24.2")

610 mm (24")

747 mm (29.4")

781 mm (30.7")

717 mm (28.2")

711 mm (28")

848 mm (33.4")

882 mm (34.7")

819 mm (32.2")

813 mm (32")

950 mm (37.4")

984 mm (38.7")

920 mm (36.2")

914 mm (36")

1052 mm (41.4")

1086 mm (42.7")

1022 mm (40.2")

1016 mm (40")

1153 mm (45.4")

1187 mm (46.7")

1124 mm (44.2")

1118 mm (44")

1255 mm (49.4")

1289 mm (50.7")

1225 mm (48.2")

1219 mm (48")

1458 mm (57.4")

1491 mm (58.7")

1427 mm (56.2")

1422 mm (56")

1661 mm (65.4")

1694 mm (66.7")

1631 mm (64.2")

1626 mm (64")

1864 mm (73.4")

1897 mm (74.7")

1834 mm (72.2")

1829 mm (72")

23

Page 24

System Installation and Alignment Connect the shielded cables to the emitter and receiver (quick-disconnect models) and route them (per local wiring code for low-voltage dc control cables) to the control module mounting location. The same cable type is used for both emitter and receiver. Cables may be cut to length at the time of installation. Emitter and receiver cable lengths may not exceed 50' (each). Contact factory Applications Department if either or both cables must be longer than 50'. Do not trim the cables until you are certain that you have routed all cables properly. The cable braid at the control module connection points may be either removed or twisted together with the drain wire (see page 28). IMPORTANT: Use ONLY Banner MICRO-SCREEN cables (see page 60). Control Module Mounting Mount the MICRO-SCREEN System control module inside a lockable enclosure which has a minimum rating of NEMA 3 (IP54). The control module may be mounted onto standard 35 mm DIN rail or may, instead, be mounted directly to the backplate of the lockable enclosure, using the supplied hardware. The MICRO-SCREEN control module should be configured before initial checkout and use. Control module configuration is done at the two banks of DIP switches located along the edge of the controller board (see Figure 20). The controller will automatically sense the length of the emitter and receiver, and set its response time accordingly.

Figure 16. Cable clearance dimensions

Key Reset Switch Mounting The Key Reset switch mounts through a 19 mm (.75") diameter hole (see Figure 18). Wires for connecting the Key Reset switch to the control module are user-supplied (also see Section 3.5.1). The Key Reset switch (supplied with the control module) must be positioned outside of the guarded area at a location that provides the switch operator with an unobstructed view of the entire guarded area, including all danger points. In addition, it must NOT be possible to reach the Key Reset switch from inside the guarded area. The switch mounts through a 19 mm (.75") diameter hole (Figure 18).

WARNING . . . The Key Reset switch must be mounted outside the guarded area at a location which provides an unobstructed view of the entire guarded area, including all danger points. In addition, it must NOT be possible to reach the Key Reset switch from inside the guarded area. Failure to do so could result in serious injury or death.

Supplied Hardware: M3.5 0.6 mm (2) Combo Head Screws M3.5 mm Washers (2) M3.5 mm x 0.6 mm Nuts (2)

115.0 mm (4.53")

(NOTE: #6 hardware can be substituted for the metric hardware) Recommended Torque Mounting Screws: 16-20 in-lbs Terminal Screws: 5 in-lbs 107.0 mm (4.21")

O-ring 5.0 mm (0.20")

Keys

97.0 mm (3.82")

Key Reset Switch

81.0 mm (3.19") 70.0 mm (2.76")

Lock Washer Slot for Screws (2) M3.5 x 0.6 mm

5.5 mm (0.22")

4.5 mm (0.18")

Hex Nut

6.5 mm (0.26")

Figure 17. Control module dimensions and mounting hole locations

24

ø19 mm (0.75")

Figure 18. MICRO-SCREEN Key Reset switch mounting

Page 25

System Installation and Alignment

3.4 Controller Board Configuration The parameters to be manually configured are: To Remove Module Cover: Place the blade of a small flat-blade screwdriver in the slot at either end of the module cover, and gently pry the cover open. The cover is not hinged; it will come completely off.

M IC R O -S C R E E N

D ia g n o s ti c

To replace the cover: Position one end and push down the opposite end to snap it into place. Finally, squeeze the sides of the module inward. o

B E se L A A t N D B oc N Y A la ko E R li n u U E FL gn kin t S N A G A me g (6 IN S n 1 E H t 2 E ) IN 5 RIN 4 G 4 G -3 1 C 6 O 4 R P .

C h a rt n

Sh oc k lo ck e le d ar

B

C

S id e

S Re T

R e v e rs e ha ay

U m

A rd

C za

N t.

TIO ex is

W op F in era or str ti c u c on o n tio alw tro ns a l re in ys lia th fo ble e llo m w an th ua e l.

A

R

N

IN

G

Figure 19. Control module cover removal

• One- and two-beam floating blanking ON or OFF • Auto Power-up ON or OFF • Fixed blanking (control module model USDINT-2T2, only) NOTE: The factory setting for all parameters is OFF. Because it has redundant microprocessors, the controller module has two identical DIP switch banks (bank A and bank B) which must be set identically. Failure to set both banks identically will cause a lockout condition when power is applied to the control box. Power to the MICRO-SCREEN System must always be OFF when changing DIP switch settings. Changing DIP switch settings with power ON will cause a lockout condition. See the inset in Figure 20 for DIP switch ON and OFF positions. Configuration DIP Switch Settings for Floating Blanking Locate the floating blanking (FB) configuration switches in banks A and B (see Figure 20). Set the switches identically at both banks. Be aware of the differences in minimum object sensitivity, penetration factor, and required light screen separation distance between the settings (see sections 2.1 and 3.2.1). Floating blanking causes the MICROSCREEN System to ignore objects of up to the sizes listed in the table below. NOTE: Both 1- and 2-beam Floating Blanking switches set to ON will cause a lockout. Standard Series Sensors Maximum Size Minimum of Undetected Object Objects Sensitivity

V-Series Sensors Maximum Size Minimum of Undetected Object Objects Sensitivity

OFF

(Not applicable)

19.1 mm (0.75")

(Not applicable)

31.8 mm (1.25")

1-beam

7.6 mm (0.30")

31.8 mm (1.25")

20.3 mm (0.80")

57.5 mm (2.25")

2-beam

20.3 mm (0.80")

44.5 mm (1.75")

45.7 mm (1.80")

82.6 mm (3.25")

Floating Blanking Program

Status Indicators Red – BLOCKED/LOCKOUT Green – CLEAR/BLANKING Yellow – RESET/ALIGNMENT

Bank "B" 1 Auto Power-up 2 Floating Blanking (1-beam) 3 Floating Blanking (2-beam)

Bank "A" 3

Floating Blanking (2-beam)

2

Floating Blanking (1-beam)

1

Auto Power-up

Program Mode LED Program Set Switch Program (left); Run (right) Switch

Off On OFF

Diagnostic Display

Example Shown: Switch #1 OFF Switch #2 ON Switch #3 OFF ON

Figure 20. Controller board configuration DIP switches

25

Page 26

System Installation and Alignment Configuration DIP Switch settings for Auto Power-up Feature ON or OFF Locate the Auto Power-up (AP) configuration DIP switches (see Figure 20) in banks A and B. If Auto Power-up is ON and the defined area is clear when power is applied to the MICRO-SCREEN System, the controller will automatically reset after conducting and passing an internal system checkout. If the switches are OFF, this initial reset is manual (via the Key Reset switch). Regardless of the setting of the Auto Power-up switches, a Key Reset is always necessary to recover from an internal lockout condition. To select Auto Power-up, remove the protective coating on both switches and push them to the ON position. The switches must be set identically at both banks A and B. Configuration DIP Switch Settings for Fixed Blanking (control module USDINT-2T2 only) Fixed blanking (if used) is programmed during the initial checkout procedure using the Program switches located on the controller board (as shown in Figure 20). See Section 3.5.5 for complete information.

3.5 Electrical Hookup and Checkouts WARNING . . .

Make the electrical connections in the order that they are presented in Sections 3.5.1 through 3.5.9. The following wiring connections are made to the control module: • Key Reset switch, • Emitter and receiver cables, • System power, • Output relay connections (FSD1, FSD2, and SSD), • AUX non-safety output, • Remote test input, and • Emergency Stop switch. NOTE: The wiring barriers on the module can accept a conductor no larger than #12 AWG. Also, the barriers may be unplugged to allow module or board replacement, without disturbing the wiring.

3.5.1 Key Reset Switch Hookup Wire is supplied by the user. Shielded cable and/or separate, grounded conduit is recommended. The wires from the Key Reset switch connect to terminals 13 and 14 of the control module (Figure 21).

26

Proper Electrical Hookup Is Imperative •

•

Electrical hookup must be made by Qualified Personnel and must comply with NEC (National Electrical Code) and local standards. Make no more connections to the MICRO-SCREEN System than are described in Sections 3.5.1 through 3.5.8 of this manual.

Connection of other wiring or equipment to the MICRO-SCREEN System could result in serious bodily injury or death.

Page 27

System Installation and Alignment

WARNING . . . Emergency Stop Switch Wiring • Whenever two or more Emergency Stop switches are connected to the same MICRO-SCREEN control module, contacts of the corresponding pole of each switch must be connected together in series. This series combination is then wired to the respective module input (to either 33 and 34 or 35 and 36). Never connect the contacts of multiple Emergency Stop switches in parallel to the MICRO-SCREEN control module inputs. Parallel connection of two or more Emergency Stop switches to one MICRO-SCREEN control module defeats the switch contact monitoring ability of the module and creates an unsafe condition which could result in serious injury or death. • Also, when two or more Emergency Stop switches are used, each switch must be individually actuated (engaged), then re-armed and the MICROSCREEN controller reset. This allows the controller to check each switch and its wiring to detect faults. Failure to test each switch individually in this manner could result in undetected faults and create an unsafe condition which could result in serious injury or death. This check must be performed during periodic checkouts (see Section 6).

3.5.2 Emergency Stop Switch Hookup The MICRO-SCREEN control module offers an input circuit at terminals 33, 34, 35 and 36 for connection of an optional customer-supplied Emergency Stop switch. As shown in Figure 21, the Emergency Stop switch must provide two separate contacts which are closed when the switch is in the RUN (armed or disengaged) position. Once engaged, the Emergency Stop switch must mechanically trip both contacts in the open position. The switch may be returned to the closed-contact position only by a deliberate action such as twisting, pulling, unlocking, etc. Additionally, NFPA 29, section 13.2 Emergency Stop Devices specifies the following switch (“stop control”) requirements: • Emergency stop pushbuttons shall be located at each operator control station and at other operating stations where emergency shutdown shall be required. • Stop and emergency stop pushbuttons shall be continuously operable from all control and operating stations where located. • Actuators of emergency stop devices shall be colored RED. The background immediately around the device actuator shall be colored YELLOW. The actuator of a pushbutton-operated device shall be of the palm or mushroom-head type. • The emergency stop actuator shall be either a momentary or self-triping type. NOTE: Some applications may have additional requirements. The user must refer to all relevant regulations. Connect the two poles of the Emergency Stop switch as shown in Figure 21. The switch in Figure 21 is shown in its “armed” position with both contacts closed. Multiple Emergency Stop switches connected to one module must use a series connection (see Warning, left). NOTES: 1) E-stop requirements contained within NFPA 79 Electrical Standard for Industrial Machinery should be met. 2) Jumpers for terminals 33 to 34 and 35 to 36 are provided and must be installed if an E-stop switch is not used. 3) A Key Reset is required after re-arming (closing) the E-Stop Switch (see Section 5.1). 4) E-stop switch contacts “a/b” and “c/d” must open simultaneously, or a lockout condition will occur. If a lockout occurs, remove the fault, then cycle (remove and reapply) the power.

• The Emergency Stop function of this control module will be ineffective if the contacts of any muting or bypass circuitry is wired in parallel with the FSD contacts.

27

Page 28

System Installation and Alignment

NON-SAFETY OUTPUT CONTACT

MACHINE CONTROL OUTPUT CONTACTS

AUX/ALARM

E-STOP SWITCH c d b

SSD

FSD2

FSD1 a b a b a b a b a

21

22

24

25

27

28

30

31

33

MICRO-SCREEN MODEL NO. USDINT-1T2

+24 dc PE Vdc COM

34 35

36

38 39 40

CAUTION

WARNING

Shock hazard may exist.

For control reliable operation always follow the instructions in the manual.

Blocked Clear

Lockout Blanking

Reset STEADY

Alignment FLASHING

BANNER ENGINEERING CORP. USA (612) 544-3164

R

LISTED Presence Sensing Device 10Y8

C

R

Diagnostic Chart on Reverse Side 0466

7

TEST 1

8

TEST 2

13 14

KEY 1

KEY 2

16 17 18 19 20

+12 COM T/R T/R DRAIN Vdc

EMITTER AND RECEIVER CABLES

Figure 21. MICRO-SCREEN System electrical connections

3.5.3 Emitter and Receiver Hookup Emitter and receiver cables both connect to wiring barrier terminals 16 through 20 (Figure 21, above). Only the use of Banner QDU Series cables (see page 60) will ensure reliable communication of data between the controller and the sensors. Match the colorcoded terminals of the module to colors of the wires in each 5-conductor cable. Double-check your wiring. Incorrect wiring can lead to component damage. There are no user adjustments or connections inside the MICRO-SCREEN sensors themselves.

28

Cable Color Code Color Description Brown = +12V dc Blue = Common White = T/R Black = T/R Uninsulated = Drain

Pin 16 17 18 19 20

Emitter and Receiver Cable Preparation Trim braided shield flush with cable Trim foil shield flush with cable

Uninsulated drain wire

NOTE: The “drain wire” is the uninsulated stranded wire which runs between the braided shield and the foil shield. The foil shield should be removed at the point where the wires exit the cable. The braided shield may be either removed or twisted together with the drain wire for connection to terminal 20.

Page 29

System Installation and Alignment

3.5.4 System Power (Temporary Connection) For permanent installation, the dc lines to the control module connect through the MPCE monitor contacts of the guarded machine (see Figure 24, page 34). However, do not wire to the MPCEs at this time. Instead, temporarily connect power directly at terminals 38 (+24V dc) and 39 (dc common) of the control module. Connect earth ground at terminal 40. This will allow the MICRO-SCREEN System to be checked out, by itself, before permanent power connections through the guarded machine’s monitor contacts are made. Permanent power connection will be made after MICRO-SCREEN System initial checkout, and is covered in Section 3.5.7.

3.5.5 MICRO-SCREEN System Initial Checkout This initial checkout procedure must be performed by a Qualified Person (see Warning, page 14). It must be done after connecting the emitter and receiver (Section 3.5.3) and temporary power (Section 3.5.4) to the MICRO-SCREEN control module, but before the MICRO-SCREEN System is connected to the machine to be guarded. Initial checkout of the MICRO-SCREEN System must always be performed by a Qualified Person (see Section 3.1). The procedure is performed on two occasions: • To ensure proper installation when the system is first installed, and • To ensure proper system function whenever any maintenance or modification is performed on the system or on the machinery being guarded by the system. (See Section 4.2 for a schedule of required checkouts.)

Power Up

Apply Power to Control Module LOCKOUT STATE

Turn Key to RESET Position

Key Reset Turn Key to RUN Position

Run

Defined Area Is Clear

Symbol Definitions Indicator OFF

Indicator ON steadily Indicator single-flashing Indicator double-flashing

BLOCKED Red

CLEAR Green

RESET Yellow

Red

Green

Yellow

If Auto Power-up is ON when power is applied to the MICRO-SCREEN System, the controller will perform an automatic Reset after passing an internal system checkout (Key Reset not needed). Auto Power-up is discussed in Section 3.4. Red

Internal System Fault (LOCKOUT)

Yellow

*Green will flash if blanking is ON. Red

Defined Area Is Blocked

Green*

Green

Yellow**

NOTE: Key must be in the RUN position at power-up. If the key is inadvertently turned to RESET while the System is operating normally, the MICRO-SCREEN System will go into a LOCKOUT condition and the RED (only) status indicator LED will flash. To return the MICROSCREEN System to RUN mode, turn the key to RESET, and then back to RUN.

**Yellow will be OFF if the System is powered up without alignment. Red

Green

Yellow

Figure 22. Operating status indicator conditions

29

Page 30

System Installation and Alignment Initial Checkout Procedure: The MICRO-SCREEN System has three operating modes: POWER UP, KEY RESET and RUN. Monitor the three status indicators on the control module or the receiver (red, yellow, and green), and refer to Figure 22. 1) Power Up the System by applying power to the control module (with the key in the RUN position). With Auto Power-up OFF, the System will power up into a lockout condition (yellow indicators only will double-flash). With Auto Power-up ON, the System will automatically enter RUN mode; go to Step 3. NOTE: Key must be in the RUN position at power-up. 2) Perform a Key Reset by turning the key clockwise to RESET. The yellow indicators will glow steadily. NOTE: Hold the key in RESET position for at least 1/2 second. This allows time for the microprocessors to run a startup diagnostic check routine. 3) Enter RUN mode by turning the key counterclockwise from RESET position to the RUN position. If the red status indicator (only) lights and flashes when the system is placed in RUN mode, an internal lockout condition exists. Refer to Section 5.1 to determine the cause of the lockout. If the red and yellow status indicators come ON, the defined area is not clear (one or more light beams are obstructed) or the system may be out of alignment. This is a trip condition. If this occurs, check the defined area for obstruction(s). The red indicator will be ON steadily. The yellow indicator will be flashing to indicate the relative number of made (cleared) light beams; the faster the flash rate, the more beams are made. The two-digit Diagnostic Display on the control module will indicate the total number of blocked beams. If all beams are blocked, the red indicator will be ON steadily, with yellow and green indicators both OFF. If beams are obstructed by one or more objects which will remain fixed in position, the fixed blanking feature may be used (control module USDINT-2T2 only). Proceed to step 4 to program fixed blanking. NOTE: Fixed blanking should only be used when the objects cannot be moved out of the defined area. If the MICRO-SCREEN System is properly aligned, the blanking is properly set, and all obstructing objects are removed from the defined area, the green and yellow indicators should come ON after step #3 has been performed (the green indicator will flash if blanking is ON, and the yellow indicator should be ON steadily). The system is now in RUN mode. If you are setting up the MICRO-SCREEN System for the first time, or if the green and yellow indicators do not come ON during step #3, perform the alignment procedure in Section 6.1. When you are certain that the emitter and receiver are aligned properly, tighten the emitter and receiver mounting hardware in position and repeat steps #1-3 above.

30