Page 51

Glossary Diverse redundancy: A design feature in which two components of different design, running from two different instruction sets (if programmed components), constantly check all system components, including each other. Emergency stop: The function offered by the MICRO-SCREEN control module which produces a lockout condition when an (optional) Emergency Stop switch is engaged. The customer-supplied Emergency Stop switch must meet certain mechanical and electrical requirements, as described in Section 3.5.2. Emitter: The light-emitting component of the MICRO-SCREEN System, consisting of a row of synchronized modulated infrared LEDs. The emitter, together with the receiver (placed opposite), creates a “curtain of light” called the defined area. Final Switching Device (FSD): The two output relays (FSD1 and FSD2) of the MICROSCREEN System which respond to an intrusion of the defined area by interrupting the circuit connecting them to the Machine Primary Control Elements (MPCEs) of the guarded machine. Fixed Blanking: A feature that allows the MICRO-SCREEN System to be programmed to ignore objects (such as brackets or fixtures) that will always be present within the defined area, so that the presence of these objects will not cause the FSDs (Final Switching Devices) of the MICRO-SCREEN System to trip (see Trip condition). If any of the fixed objects are moved within or removed from the defined area, a lockout condition results. Floating Blanking: A feature that allows the MICRO-SCREEN System to be programmed to produce an intentionally disabled light beam within the “light screen,” which appears to move up and down (“float”) in order to allow the feeding of an object through the light screen (the defined area) at any point along the length of the screen without causing a Trip condition. The MICRO-SCREEN System offers one- or two-beam floating blanking to allow multiple objects (usually workpiece material), to move through the defined area without tripping the Final Switching Devices. Use of floating blanking increases minimum object sensitivity and the required separation distance. FMEA (Failure Mode and Effects Analysis): A testing procedure by which potential failure modes in a system are analyzed to determine their results or effects on the system. Component failure modes that produce either no effect or a lockout condition are permitted; failures which cause an unsafe condition (a failure to danger) are not. Banner MICRO-SCREEN Systems are extensively FMEA tested. Forced-guided contacts: Relay contacts that are mechanically linked together, so that when the relay coil is energized or de-energized, all of the linked contacts move together. If one set of contacts in the relay becomes immobilized, no other contact of the same relay will be able to move. The function of forced-guided contacts is to enable the safety circuit to check the status of the relay. Forced-guided contacts are also known as “positive-guided contacts,” “captive contacts,” “locked contacts,” or “safety relays.” MICRO-SCREEN Systems use output relays with forced-guided contacts.

51

Page 52

Glossary Full-revolution devices: A type of machine drive arranged such that, once started, the machine can only be stopped when the full cycle is complete. Examples include positive key clutches and similar mechanisms. Banner MICRO-SCREEN Systems may not be used with full-revolution devices. Guarded machine: The machine whose point of operation is guarded by a MICROSCREEN System, and whose MPCEs and MSCE are connected to relays FSD1, FSD2, and SSD of the MICRO-SCREEN System. Hard guarding: Screens, bars, or other mechanical barriers that prevent a person from reaching over, under, or around the defined area of an installed MICRO-SCREEN System and into the point of operation of the guarded machine. Internal lockout: A lockout condition that occurs due to an internal MICRO-SCREEN System problem. Indicated by the red status indicator LED (only) flashing. Requires the attention of a Qualified Person. Key Reset: A key-operated switch that is used to restore the Final Switching Devices (FSDs) and Secondary Switching Device (SSD) to the ON state from a lockout condition. Also refers to the act of using the switch to reset the MICRO-SCREEN System. Latch condition: In latching output models, the response of the Final Switching devices (FSD) relays when an object equal to or greater than the diameter of the specified test piece enters the defined area. In a Latch condition, FSD1 and FSD2 simultaneously deenergize and open their contacts. The latch must be reset after the defined area is cleared by momentarily closing the normally open contact of the Latch Reset switch. (See Trip condition.) Lockout condition: A condition of the MICRO-SCREEN System that is automatically attained either: (1) when its dc supply mains are interrupted and restored, or (2) in response to certain failure signals. When a lockout condition occurs, the MICROSCREEN System’s FSD, SSD, and Auxiliary Monitor Relay contacts open, and a Key Reset is required to return the system to the RUN condition. Machine primary control element (MPCE): An electrically powered element, external to the MICRO-SCREEN System, which directly controls the machine’s normal operating motion in such a way that it is last (in time) to operate when motion is either initiated or arrested. Machine response time: The time between the interruption by the Final Switching Devices (FSDs) of the electrical supply to the Machine Primary Control Element(s) (MPCEs) and the instant when the dangerous parts of the machine reach a safe state by being brought to rest. Machine secondary control element (MSCE): A machine control element independent of the Machine Primary Control Element(s) (MPCEs), capable of removing the source of power from the prime mover of the relevant dangerous machine parts.

52

Page 53

Glossary Minimum object sensitivity: The minimum-diameter object that a light curtain system can reliably detect. Objects of this diameter or greater will be detected anywhere in the sensing field. A smaller object can pass undetected through the curtain of light if it passes exactly midway between two adjacent light beams. Same as MODS, Minimum Object Detection Size. See also specified test piece. MODS (minimum object detection size): See minimum object sensitivity. MPCE monitor contacts: The normally open and normally closed contacts of a guarded machine’s MPCEs which are connected in series with the power supply to the MICROSCREEN System. Any inconsistency of action between the two sets of monitor contacts will remove power from the MICRO-SCREEN System and cause a lockout condition. (See Figure 24.) OFF state (of Final and Secondary Switching Devices): In the OFF state, the output circuit is broken and interrupts the flow of current. ON state (of Final and Secondary Switching Devices): In the ON state, the output circuit is complete and permits the flow of current. OSHA (Occupational Safety and Health Administration); OSHA CFR 1910.217: Occupational Safety and Health Administration (a US Federal agency), Division of the US Department of Labor, that is responsible for the regulation of workplace safety. OSHA regulations often follow ANSI standards, including mechanical power press requirements (OSHA CFR 1910.217). These regulations become law when adopted by OSHA, and must be followed. (See page 63.) Output relays: The devices (within the MICRO-SCREEN System) that are used to initiate an “emergency stop” signal. The MICRO-SCREEN System’s output relays (FSD1, FSD2, and SSD) use forced-guided contacts. Point of operation: The area of the guarded machine where a workpiece is positioned and a machine function (i.e., shearing, forming, punching, assembling, welding, etc.) is performed upon it. Power supply board: A removable printed circuit board which contains the power supply circuit and output relays and is located inside the MICRO-SCREEN System control module. A green LED on the power supply board lights whenever dc power is present on the board. Power-up/power interrupt lockout: A lockout condition of the MICRO-SCREEN System that, if Auto Power-up is OFF, occurs when the system is powered up (including upon power-up after a loss of power). Indicated by the yellow status indicator LED (only) flashing. Requires a Key Reset by a Designated Person.

53

Page 54

Glossary PSDI (Presence-Sensing-Device Initiation): An application in which a presencesensing device is used to actually start the cycle of a machine. In a typical situation, an operator manually positions a part in the machine for the operation. When the operator moves out of the danger area, the presence-sensing device starts the machine (no start switch is used). The machine cycle runs to completion, and the operator can then insert a new part and start another cycle. The presence-sensing device continually guards the machine. Single break mode is used when the part is automatically ejected after the machine operation. Double break mode is used when the part is both inserted (to begin the operation) and removed (after the operation) by the operator. PSDI is defined in OSHA CFR 1910.217. Banner MICRO-SCREEN Systems may not be used as PSDI devices on mechanical power presses, per OSHA regulation 29 CFR 1910.217. Qualified Person: A person or persons who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training, and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work (ANSI B30.2-1983). Receiver: The light-receiving component of the MICRO-SCREEN System, consisting of a row of synchronized phototransistors. The receiver, together with the emitter (placed opposite), creates a “light screen” or “curtain of light” called the defined area. Secondary switching device (SSD): The output relay of the MICRO-SCREEN System which, in a lockout condition, interrupts the circuit connecting it to the Machine Secondary Control Element (MSCE). Self-checking (circuitry): A circuit with the capability to electronically verify that all of its own critical circuit components, along with their redundant backups, are operating properly. Banner MICRO-SCREEN Systems are self-checking. Separation distance: That distance, along the direction of approach, between the outermost position at which the appropriate test piece will just be detected and the nearest dangerous machine parts. Also called safety distance. Single-stroke press: See full-revolution devices. Specified test piece: An opaque object of the minimum cross section required to place the MICRO-SCREEN System into a trip condition when inserted into any part of the defined area. See also minimum object sensitivity. Supplemental guarding: Additional electrosensitive safety device(s), possibly employed along with hard guarding measures, used for the purpose of preventing a person from reaching over, under, or around the defined area of an installed MICROSCREEN System and into the point of operation of the guarded machine.

54

Page 55

Glossary Trip condition: In trip output models, the response of the Final Switching Device (FSD) relays when an object equal to or greater than the diameter of the specified test piece enters the defined area. In a trip condition, FSD1 and FSD2 simultaneously de-energize and open their contacts. A Trip condition clears automatically when the object is removed from the defined area. (See Latch condition.) UL (Underwriters Laboratory): A third-party organization which tests a manufacturer’s products for compliance with appropriate Standards, electrical and/or safety codes. Compliance is indicated by their listing mark on the product.

55

Page 56

Specifications

MICRO-SCREEN Standard Series Sensor Specifications Defined Area

Number of Beams

Defined Area

Number of Beams

Emitter USE424Y Receiver USR424Y

102 mm (4")

8

Emitter USE2824Y Receiver USR2824Y

711 mm (28")

56

Emitter USE824Y Receiver USR824Y

203 mm (8")

16

Emitter USE3224Y Receiver USR3224Y

813 mm (32")

64

Emitter USE1224Y Receiver USR1224Y

305 mm (12")

24

Emitter USE3624Y Receiver USR3624Y

914 mm (36")

72

Emitter USE1624Y Receiver USR1624Y

406 mm (16")

32

Emitter USE4024Y Receiver USR4024Y

1016 mm (40")

80

Emitter USE2024Y Receiver USR2024Y

508 mm (20")

40

Emitter USE4424Y Receiver USR4424Y

1118 mm (44")

88

Emitter USE2424Y Receiver USR2424Y

610 mm (24")

48

Emitter USE4824Y Receiver USR4824Y

1219 mm (48")

96

Models

Models

Emitter/receiver separation

15 cm (6") to 9 m (30')

Minimum object sensitivity

19.1 mm (0.75") floating blanking OFF 31.8 mm (1.25") 1-beam floating blanking ON 44.5 mm (1.75") 2-beam floating blanking ON

Response time

Light Screens: Less than 38 milliseconds (all lengths) E-Stop: Less than 15 milliseconds

Self-checking interval

20 milliseconds

Ambient light immunity

>10,000 lux at 5° angle of incidence

Strobe light immunity

Totally immune to one Federal Signal Corp. “Fireball” model FB2PST strobe.

Emitter elements

Infrared LEDs; 880 nm peak emission

Status indicators

Emitter: Green indicator for power ON indication Receiver: Red, yellow, and green status indicators with same functions as those on control module (see Control Module Specifications, page 57). Yellow also indicates alignment. Indicators are visible on three sides of receiver base.

Emitter and receiver enclosures

Size: See Figure 15, page 23. Materials: Aluminum; yellow polyester painted finish; acrylic lens cover Rating: NEMA 4, 13; IEC IP65

Mounting hardware

Emitter and receiver each are supplied with a pair of swivel end mounting brackets. (Sensor lengths 40" to 48" are supplied with one center support bracket; see page 21.) Mounting brackets are 13-gauge cold-rolled black zinc chromate finished steel. Control module is supplied with hardware for mounting directly to a flat plate; control module may instead be attached to a 35 mm DIN rail.

Certifications

See controller specifications, page 58.

56

Page 57

Specifications

MICRO-SCREEN V-Series Sensor Specifications Defined Area

Number of Beams

Emitter USE2412Y Receiver USR2412Y

610 mm (24")

24

Emitter USE3212Y Receiver USR3212Y

813 mm (32")

Emitter USE4012Y Receiver USR4012Y Emitter USE4812Y Receiver USR4812Y

Models

Defined Area

Number of Beams

Emitter USE5612Y Receiver USR5612Y

1422 mm (56")

56

32

Emitter USE6412Y Receiver USR6412Y

1626 mm (64")

64

1016 mm (40")

40

Emitter USE7212Y Receiver USR7212Y

1829 mm (72")

72

1219 mm (48")

48

Models

Emitter/receiver separation

24" to 48" Emitters and Receivers 15 cm (6") to 9 m (30')

56" to 72" Emitters and Receivers 15 cm (6") to 6 m (20')

Minimum object sensitivity

31.8 mm (1.25") floating blanking OFF 57.5 mm (2.25") 1-beam floating blanking ON 82.6 mm (3.25") 2-beam floating blanking ON

Response time

Light Screens: Less than 38 milliseconds (all lengths) E-Stop: Less than 15 milliseconds

Self-checking interval

20 milliseconds

Ambient light immunity

>10,000 lux at 5° angle of incidence

Strobe light immunity

Totally immune to one Federal Signal Corp. “Fireball” model FB2PST strobe.

Emitter elements

Infrared LEDs; 880 nm peak emission

Status indicators

Emitter: Green indicator for power ON indication Receiver: Red, yellow, and green status indicators with same functions as those on control module (see Control Module Specifications, page 57). Yellow also indicates alignment. Indicators are visible on three sides of receiver base.

Emitter and receiver enclosures

Size: See Figure 15, page 23. Materials: Aluminum; yellow polyester painted finish; acrylic lens cover Rating: NEMA 4, 13; IEC IP65

Mounting hardware

Emitter and receiver each are supplied with a pair of swivel end mounting brackets. (Sensor lengths 40" to 48" are supplied with one center support bracket; Sensor lengths 56" to 72" are supplied with two center support brackets; see page 21.) Mounting brackets are 13-gauge cold-rolled black zinc chromate finished steel. Control module is supplied with hardware for mounting directly to a flat plate; control module may instead be attached to a 35 mm DIN rail.

Certifications

See controller specifications, page 58.

57

Page 58

Specifications

MICRO-SCREEN Controller Specifications System power requirements

24V dc ±15%, 10% maximum ripple, 1.5 amps max.

Fuse rating

2 amp, 250 V (3 AG or 5 x 20 mm slow blow) Control Box and Receiver : Red = BLOCKED Green = CLEAR Yellow = RESET

Status indicators (on control module and receiver)

Flashing red Flashing green Flashing Yellow: Double-flashing Single-flashing

= LOCKOUT = BLANKING ON = Waiting for Power-up Manual Key Reset = ALIGNMENT. Flash rate increases with the number of sensing beams “made,” solid yellow when aligned and defined area is clear.

Emitter: Emitter has green status indicator to indicate power ON. Diagnostic indicator

Two-digit numeric display indicates cause of lockout condition and total number of beams blocked (see Figure 25, page 39).

Controls and adjustments

Keyed Reset of system lockout conditions Floating Blanking selection switches and Fixed Blanking programming switches Auto Power-up On-Off switches

Emergency Stop switch input

Emergency Stop switch must offer two normally closed contacts and be capable of switching 50 mA @ 30V dc. Function stop category 0 per NFPA 79 and EN 418, Safety category 4 per EN 954-1

Test input

Terminals must be closed for a minimum of 0.05 seconds in order to guarantee a test input signal. The switching device used must be capable of switching 15-50V dc at 20 to 100 mA.

AUX Non-safety output contact

Reed relay; 125V ac or dc max., 500 mA max. (10VA maximum, resistive load)

Output configuration (FSD1, FSD2, and SSD)

Forced-guided contact relays, 250V ac max., 4 amps max. (resistive load). Mechanical life 10,000,000 operations (minimum). Electrical life (at full rated load) 100,000 operations (typical). Arc suppression is recommended when switching inductive loads. See Figure 24, page 34.

Operating temperature

Size: See figure 17, page 24. Material: gray polycarbonate, clear polycarbonate cover Rating: NEMA 1, (IP 20) 0° to +50°C (+32° to 122°F)

Relative humidity

95% maximum (non-condensing)

FMEA tested (Failure Mode and Effects Analysis)

Per requirements IEC 61496-1

Enclosure

Emitters and Receivers with Integral Cables: Cables are 7.6 meters (25') long and measure 8.1 mm (0.32") in diameter. Conductors are 20-gauge. Cables are shielded and PVC-jacketed.

Cables

Emitters and Receivers with Quick-Disconnect: Sensors have 300 mm (12") long cable, pigtail-terminated with a 5-pin Euro-style quickdisconnect fitting. Mating 5-conductor shielded cables have straight QD connector molded onto one end. Mating cables are ordered separately, and are available in lengths of 4.5 m (15'), 7.6 m (25') and 15 m (50'). NOTE: Contact factory when cable length exceeding 15 m (50') is required. Use only Banner cables, which incorporate a “twisted pair” for noise immunity on RS485 data communication lines. Use of other cables may result in “nuisance” lockouts.

Certifications

R

LISTED

58

Presence Sensing Device

R

LISTED

Presence Sensing Device

IEC 61496-1&2, Type 4

Page 59

Models and Accessories MICRO-SCREEN Systems are sold as kits including the following: a control box, an emitter and receiver of equal length and equal number of beams, emitter and receiver mounting hardware, and two cables. Choose 300 mm (12") pigtail quick-disconnect cables plus mating cables in one of 3 lengths, or unterminated, integral 7.6 m (25') cables. Cables are interchangeable between the emitter and the receiver if they have the same kinds of connectors. See the Banner Machine Safety Products Catalog for a complete list of available kits. Components are also available separately (see chart below).

MICRO-SCREEN Standard Series Emitters (E) and Receivers (R) Minimum Object Detection Size = 19 mm (0.75") Defined Area

Number of Beams

102 mm (4")

8

203 mm (8")

16

305 mm (12")

24

406 mm (16")

32

508 mm (20")

40

610 mm (24")

48

711 mm (28")

56

813 mm (32")

64

914 mm (36")

72

1016 mm (40")

80

1118 mm (44")

88

1219 mm (48")

96

Integral 7.6 m (25') Cable Models Model Number Part Number USE424YI 42500 USR424YI 42501 USE824YI 42502 USR824YI 42503 USE1224YI 42504 USR1224YI 42505 USE1624YI 42506 USR1624YI 42507 USE2024YI 42508 USR2024YI 42509 USE2424YI 42510 USR2424YI 42511 USE2824YI 42512 USR2824YI 42513 USE3224YI 42514 USR3224YI 42515 USE3624YI 42516 USR3624YI 42517 USE4024YI 42518 USR4024YI 42519 USE4424YI 42520 USR4424YI 42521 USE4824YI 42522 USR4824YI 42523

Pigtail Quick-disconnect Models Quick-disconnect Fitting Models Model Number Part Number Model Number Part Number USE424YP2 49601 USE424Y 55134 USR424YP2 49602 USR424Y 55135 USE824YP2 49603 USE824Y 55136 USR824YP2 49604 USR824Y 55137 USE1224YP2 49605 USE1224Y 55138 USR1224YP2 49606 USR1224Y 55139 USE1624YP2 49607 USE1624Y 55140 USR1624YP2 49608 USR1624Y 55141 USE2024YP2 49609 USE2024Y 55143 USR2024YP2 49610 USR2024Y 55144 USE2424YP2 49611 USE2424Y 55145 USR2424YP2 49612 USR2424Y 55146 USE2824YP2 49613 USE2824Y 55147 USR2824YP2 49614 USR2824Y 55148 USE3224YP2 49615 USE3224Y 55149 USR3224YP2 49616 USR3224Y 55150 USE3624YP2 49617 USE3624Y 55151 USR3624YP2 49618 USR3624Y 55152 USE4024YP2 49619 USE4024Y 55153 USR4024YP2 49620 USR4024Y 55154 USE4424YP2 49621 USE4424Y 55155 USR4424YP2 49622 USR4424Y 55156 USE4824YP2 49623 USE4824Y 55157 USR4824YP2 49624 USR4824Y 55158

MICRO-SCREEN V-Series Emitters (E) and Receivers (R) Minimum Object Detection Size = 32 mm (1.25") Defined Area

Number of Beams

610 mm (24")

24

813 mm (32")

32

1016 mm (40")

40

1219 mm (48")

48

1422 mm (56")

56

1626 mm (64")

64

1829 mm (72")

72

Integral 7.6 m (25') Cable Models Model Number Part Number USE2412YI 54460 USR2412YI 54461 USE3212YI 54462 USR3212YI 54463 USE4012YI 54464 USR4012YI 54465 USE4812YI 54466 USR4812YI 54467 USE5612YI 51314 USR5612YI 51315 USE6412YI 51316 USR6412YI 51317 USE7212YI 51318 USR7212YI 51319

Pigtail Quick-disconnect Models Quick-disconnect Fitting Models Model Number Part Number Model Number Part Number USE2412YP2 54452 USE2412Y 55159 USR2412YP2 54453 USR2412Y 55160 USE3212YP2 54454 USE3212Y 55161 USR3212YP2 54455 USR3212Y 55162 USE4012YP2 54456 USE4012Y 55163 USR4012YP2 54457 USR4012Y 55164 USE4812YP2 54458 USE4812Y 55165 USR4812YP2 54459 USR4812Y 55166 USE5612YP2 51308 USE5612Y 55167 USR5612YP2 51309 USR5612Y 55168 USE6412YP2 51310 USE6412Y 55169 USR6412YP2 51311 USR6412Y 55170 USE7212YP2 51312 USE7212Y 55171 USR7212YP2 51313 USR7212Y 55172

59

Page 60

Models and Accessories

Controller (One required per system) Description

Model Number

Part Number

24V dc control module

USDINT-1T2

48536

24V dc control module with fixed blanking

USDINT-2T2

49785

Cables (Two required per system, one per sensor*) Description

Model Number

Part Number

4.5 m (15') cable, straight QD connector

QDU-515C

46391

7.6 m (25') cable, straight QD connector

QDU-525C

46392

15 m (50') cable**, straight QD connector

QDU-550C

46393

* Not Required for sensors with integral 7.6 m (25') cable. ** Contact factory Applications Department for information on cable lengths greater than 50'.

Documentation The following documentation is supplied with each MICRO-SCREEN System Control Module. Additional copies are available at no charge.

Description

Part Number

Instruction Manual for MICRO-SCREEN Systems

48753

Checkout Procedure Card (Daily)

48751

Checkout Procedure Card (Semi-annual)

48752

Retrofit Mounting Bracket Kits Description

Model Number

Part Number

Retrofit for STI MS43

USMB-4

55668

Retrofit for STI MS42

USMB-5

55669

Description

Model Number

Part Number

Self-contained visible-beam laser tool for alignment of any MICRO-SCREEN emitter/receiver pair. Includes retroreflective target material and two mounting clips

LAT-1

52150

LAT-1 Laser Alignment Tool

60